[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-25":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":566},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,25,50,2486,[13,34,44,50,56,68,74,80,86,98,110,122,134,152,167,182,197,203,215,221,233,245,257,269,282,294,303,312,321,333,341,349,357,369,379,391,403,415,427,439,451,460,472,484,496,508,516,526,539,552],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},974145,1,"单选题","正常状态下，火灾自动报警系统控制器由（ ）电源供电工作。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","AC380V",false,{"key":24,"text":25,"correct":26},"B","AC220V",true,{"key":28,"text":29,"correct":22},"C","DC380V",{"key":31,"text":32,"correct":22},"D","DC220V","",{"id":35,"libraryId":5,"type":36,"typeLabel":37,"stem":38,"options":39,"answer":41,"analysis":33},974146,3,"判断题","当可燃气体探测报警系统主机处于监控状态时，系统响应按键输入；无事件情况下（不报警、不报故障），液晶显示最高浓度的可燃气体探测器的值与时钟的实时时间。（ ）",[40,42],{"key":20,"text":41,"correct":26},"正确",{"key":24,"text":43,"correct":22},"错误",{"id":45,"libraryId":5,"type":36,"typeLabel":37,"stem":46,"options":47,"answer":43,"analysis":33},974147,"电气火灾监控设备应能对本机及所配接的电气火灾监控探测器进行功能检查，在执行自检期间，与其连接的外接设备应按相应指令动作，还应能手动检查其音响器件和面板上所有指示灯、显示器的工作状态。（ ）",[48,49],{"key":20,"text":41,"correct":22},{"key":24,"text":43,"correct":26},{"id":51,"libraryId":5,"type":36,"typeLabel":37,"stem":52,"options":53,"answer":43,"analysis":33},974148,"准工作状态下，水流指示器无需标注水流指示方向，安装牢固，末端测试时报警功能正常。（ ）",[54,55],{"key":20,"text":41,"correct":22},{"key":24,"text":43,"correct":26},{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":24,"analysis":33},974149,"发生火灾时，湿式报警阀开启，打通输水通道；水力警铃动作并发出声报警信号，该声响在3m远处声强不低于（ ）dB;压力开关动作，连锁启动消防水泵，并向火灾自动报警系统发出压力开关动作信号。",[60,62,64,66],{"key":20,"text":61,"correct":22},"65",{"key":24,"text":63,"correct":26},"70",{"key":28,"text":65,"correct":22},"75",{"key":31,"text":67,"correct":22},"85",{"id":69,"libraryId":5,"type":36,"typeLabel":37,"stem":70,"options":71,"answer":43,"analysis":33},974150,"火灾自动报警系统控制器可以长时间处于备电工作状态。（ ）",[72,73],{"key":20,"text":41,"correct":22},{"key":24,"text":43,"correct":26},{"id":75,"libraryId":5,"type":36,"typeLabel":37,"stem":76,"options":77,"answer":43,"analysis":33},974151,"检查判断防烟排烟系统风机及电气控制柜的工作状态时，不需要检查电气控制柜的供电状态。（ ）",[78,79],{"key":20,"text":41,"correct":22},{"key":24,"text":43,"correct":26},{"id":81,"libraryId":5,"type":36,"typeLabel":37,"stem":82,"options":83,"answer":41,"analysis":33},974152,"根据所安装喷头的结构形式，自动喷水灭火系统可分为闭式系统和开式系统。（ ）",[84,85],{"key":20,"text":41,"correct":26},{"key":24,"text":43,"correct":22},{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":20,"analysis":33},974153,"自动喷水灭火系统以（ ）为灭火剂。在火灾发生时，可不依赖于人工干预，自动完成火灾探测、报警、启动系统和喷水控（灭）火的系统，是应用范围最广、用量最多且造价低廉的自动灭火系统。",[90,92,94,96],{"key":20,"text":91,"correct":26},"水",{"key":24,"text":93,"correct":22},"干粉",{"key":28,"text":95,"correct":22},"二氧化碳",{"key":31,"text":97,"correct":22},"氮气",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":20,"analysis":33},974154,"以湿式系统为例，对自动喷水灭火系统工作状态进行检查判断，首先应检查判断（ ）的工作状态。",[102,104,106,108],{"key":20,"text":103,"correct":26},"消防供水设施",{"key":24,"text":105,"correct":22},"末端试水装置",{"key":28,"text":107,"correct":22},"系统管网及附件、水流指示器、洒水喷头",{"key":31,"text":109,"correct":22},"报警阀组",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":31,"analysis":33},974155,"剩余电流式电气火灾监控探测器的报警设定值范围应为（ ）。",[114,116,118,120],{"key":20,"text":115,"correct":22},"50-500mA",{"key":24,"text":117,"correct":22},"20-500mA",{"key":28,"text":119,"correct":22},"50-1000mA",{"key":31,"text":121,"correct":26},"20-1000mA",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":31,"analysis":33},974156,"下列不属于集中火灾报警控制器的主要功能的有（ ）。",[126,128,130,132],{"key":20,"text":127,"correct":22},"火灾报警功能",{"key":24,"text":129,"correct":22},"火灾报警控制功能",{"key":28,"text":131,"correct":22},"故障报警功能",{"key":31,"text":133,"correct":26},"联动控制功能",{"id":135,"libraryId":5,"type":136,"typeLabel":137,"stem":138,"options":139,"answer":151,"analysis":33},974157,2,"多选题","消防设备末端配电装置由（ ）等器件组成。",[140,142,144,146,148],{"key":20,"text":141,"correct":26},"配电箱",{"key":24,"text":143,"correct":26},"按钮",{"key":28,"text":145,"correct":26},"指示灯",{"key":31,"text":147,"correct":26},"转换开关",{"key":149,"text":150,"correct":22},"E","报警触发装置","ABCD",{"id":153,"libraryId":5,"type":136,"typeLabel":137,"stem":154,"options":155,"answer":166,"analysis":33},974158,"故障电弧是一种气体游离放电现象，引起故障电弧的原因有很多，如（ ）。",[156,158,160,162,164],{"key":20,"text":157,"correct":26},"电气线路绝缘层老化破损",{"key":24,"text":159,"correct":26},"电压电流过高",{"key":28,"text":161,"correct":26},"空气潮湿",{"key":31,"text":163,"correct":22},"电气线路断路",{"key":149,"text":165,"correct":26},"设备中绝缘层老化破损","ABCE",{"id":168,"libraryId":5,"type":136,"typeLabel":137,"stem":169,"options":170,"answer":181,"analysis":33},974159,"下列选项中，不属于通过集中火灾报警控制器查看报警信息和确定报警部位的是（ ）。",[171,173,175,177,179],{"key":20,"text":172,"correct":22},"通过信息列表查看",{"key":24,"text":174,"correct":22},"通过“火警监管”查看",{"key":28,"text":176,"correct":22},"通过消防控制室图形显示装置查看",{"key":31,"text":178,"correct":26},"通过摄像头查看",{"key":149,"text":180,"correct":26},"现场查看","DE",{"id":183,"libraryId":5,"type":136,"typeLabel":137,"stem":184,"options":185,"answer":196,"analysis":33},974160,"下列关于机械排烟系统的组件的说法正确的是（ ）。",[186,188,190,192,194],{"key":20,"text":187,"correct":26},"排烟防火阀平时呈开启状态",{"key":24,"text":189,"correct":22},"排烟阀平时呈开启状态",{"key":28,"text":191,"correct":22},"排烟防火阀平时呈关闭状态",{"key":31,"text":193,"correct":26},"排烟阀平时呈关闭状态",{"key":149,"text":195,"correct":26},"排烟口通常设置在防烟分区内需要排烟的走道、房间的顶棚或靠近顶棚的墙面上","ADE",{"id":198,"libraryId":5,"type":36,"typeLabel":37,"stem":199,"options":200,"answer":43,"analysis":33},974161,"挡烟垂壁按挡烟部位的刚度性能可分为柔性挡烟垂壁、中性挡烟垂壁和刚性挡烟垂壁。（ ）",[201,202],{"key":20,"text":41,"correct":22},{"key":24,"text":43,"correct":26},{"id":204,"libraryId":5,"type":15,"typeLabel":16,"stem":205,"options":206,"answer":28,"analysis":33},974162,"电气火灾监控设备应能接收来自电气火灾监控探测器的监控报警信号，并在（ ）内发出声、光报警信号，指示报警部位，显示报警时间。",[207,209,211,213],{"key":20,"text":208,"correct":22},"3s",{"key":24,"text":210,"correct":22},"5s",{"key":28,"text":212,"correct":26},"10s",{"key":31,"text":214,"correct":22},"20s",{"id":216,"libraryId":5,"type":36,"typeLabel":37,"stem":217,"options":218,"answer":41,"analysis":33},974163,"在集中火灾报警控制器上模拟产生各类报警信息时不应损坏系统组件，每次操作完成后，应将设备恢复到正常工作状态。（ ）",[219,220],{"key":20,"text":41,"correct":26},{"key":24,"text":43,"correct":22},{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":28,"analysis":33},974164,"正常工况下报警阀组各控制阀的启闭状态，下列描述正确的是（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":22},"泄水阀—常开",{"key":24,"text":228,"correct":22},"报警管路控制阀—常闭",{"key":28,"text":230,"correct":26},"警铃试验阀--常闭",{"key":31,"text":232,"correct":22},"水源侧管路控制阀（信号阀）--常闭",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":20,"analysis":33},974165,"湿式系统的适用范围是（ ）。",[237,239,241,243],{"key":20,"text":238,"correct":26},"环境温度不低于4℃且不高于70℃的场所",{"key":24,"text":240,"correct":22},"环境温度低于4℃或高于70℃的场所",{"key":28,"text":242,"correct":22},"严重危险级Ⅱ级的场所",{"key":31,"text":244,"correct":22},"准工作状态下严禁误喷的场所",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":28,"analysis":33},974166,"下列系统中，（ ）在准工作状态下，配水管道内不充水，火灾发生时，由火灾自动报警系统、充气管道上的压力开关连锁控制预作用装置和启动消防水泵，向配水管道供水，喷头受热开放后即能喷水灭火。",[249,251,253,255],{"key":20,"text":250,"correct":22},"湿式系统",{"key":24,"text":252,"correct":22},"干式系统",{"key":28,"text":254,"correct":26},"预作用系统",{"key":31,"text":256,"correct":22},"雨淋系统",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":20,"analysis":33},974167,"通过集中火灾报警控制器和消防控制室图形显示装置查看报警信息确定报警位置的技能操作中，①在集中火灾报警控制器控制面板显示屏右侧的信息显示列表上查看火警信息，可以同时看到报警编号和位置名称。②在集中火灾报警控制器控制面板的显示屏上找到“火警监管”图标，并点击图标，显示火警监管信息。③点击显示屏第一栏“火警监管”后面的[点此切换]，查看所有的火警信息和报警部位。④找到消防控制室图形显示装置，查看楼层平面图下方的火警状态信息。看“火警”信息标识是否显示红色，信息栏中有没有显示报警详细信息。⑤在楼层平面图中找到报警位置和编号。⑥记录检查情况。操作程序正确的是（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":26},"①②③④⑤⑥",{"key":24,"text":264,"correct":22},"②③①④⑤⑥",{"key":28,"text":266,"correct":22},"④⑤②③①⑥",{"key":31,"text":268,"correct":22},"④⑤①②③⑥",{"id":270,"libraryId":5,"type":136,"typeLabel":137,"stem":271,"options":272,"answer":166,"analysis":33},974168,"湿式、干式自动喷水灭火系统主要由（ ）组成。",[273,275,276,278,280],{"key":20,"text":274,"correct":26},"闭式喷头",{"key":24,"text":109,"correct":26},{"key":28,"text":277,"correct":26},"水流报警装置",{"key":31,"text":279,"correct":22},"开式喷头",{"key":149,"text":281,"correct":26},"管道和供水设施",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":31,"analysis":33},974169,"点击一个有负载的回路，出现回路配接设备的位图信息。在位图显示方式下，“P”表示（ ）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"报警类型",{"key":24,"text":289,"correct":22},"手动按钮",{"key":28,"text":291,"correct":22},"消火栓按钮",{"key":31,"text":293,"correct":26},"压力开关",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":31,"analysis":33},974170,"点击一个有负载的回路，出现回路配接设备的位图信息。在位图显示方式下，“B”表示（ ）。",[298,299,300,301],{"key":20,"text":287,"correct":22},{"key":24,"text":289,"correct":22},{"key":28,"text":291,"correct":22},{"key":31,"text":302,"correct":26},"消防广播",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":24,"analysis":33},974171,"点击一个有负载的回路，出现回路配接设备的位图信息。在位图显示方式下，“S”表示（ ）。",[307,308,310,311],{"key":20,"text":287,"correct":22},{"key":24,"text":309,"correct":26},"声光警报",{"key":28,"text":291,"correct":22},{"key":31,"text":293,"correct":22},{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":24,"analysis":33},974172,"点击一个有负载的回路，出现回路配接设备的位图信息。在位图显示方式下，“M”表示（ ）。",[316,317,319,320],{"key":20,"text":287,"correct":22},{"key":24,"text":318,"correct":26},"模块类型",{"key":28,"text":291,"correct":22},{"key":31,"text":293,"correct":22},{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":31,"analysis":33},974173,"点击一个有负载的回路，出现回路配接设备的位图信息。在位图显示方式下，灰色表示（ ）。",[325,327,329,331],{"key":20,"text":326,"correct":22},"火警状态",{"key":24,"text":328,"correct":22},"启动状态",{"key":28,"text":330,"correct":22},"请求状态",{"key":31,"text":332,"correct":26},"屏蔽状态",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":20,"analysis":33},974174,"点击一个有负载的回路，出现回路配接设备的位图信息。在位图显示方式下，红色表示（ ）。",[337,338,339,340],{"key":20,"text":326,"correct":26},{"key":24,"text":328,"correct":22},{"key":28,"text":330,"correct":22},{"key":31,"text":332,"correct":22},{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":24,"analysis":33},974175,"点击一个有负载的回路，出现回路配接设备的位图信息。在位图显示方式下，绿色表示（ ）。",[345,346,347,348],{"key":20,"text":326,"correct":22},{"key":24,"text":328,"correct":26},{"key":28,"text":330,"correct":22},{"key":31,"text":332,"correct":22},{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":28,"analysis":33},974176,"点击一个有负载的回路，出现回路配接设备的位图信息。在位图显示方式下，蓝色表示（ ）。",[353,354,355,356],{"key":20,"text":326,"correct":22},{"key":24,"text":328,"correct":22},{"key":28,"text":330,"correct":26},{"key":31,"text":332,"correct":22},{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":20,"analysis":33},974177,"在火灾报警控制器上，操作面板上有（ ）键，按下此键可以查看系统存储的各类信息。",[361,363,365,367],{"key":20,"text":362,"correct":26},"记录检查",{"key":24,"text":364,"correct":22},"设备检查",{"key":28,"text":366,"correct":22},"系统设置",{"key":31,"text":368,"correct":22},"自检",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":20,"analysis":33},974178,"火灾报警控制器操作面板上具有（ ）键，按下此键可以查看系统存储的各类信息。",[373,374,376,377],{"key":20,"text":362,"correct":26},{"key":24,"text":375,"correct":22},"现场检查",{"key":28,"text":368,"correct":22},{"key":31,"text":378,"correct":22},"启动",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":20,"analysis":33},974179,"总线控制盘操作面板上设有多个手动控制单元，每个单元包括（ ），每个操作按钮均可通过逻辑编程实现对各类、各分区、各具体设备的控制。",[383,385,387,389],{"key":20,"text":384,"correct":26},"一个操作按钮和两个状态指示灯",{"key":24,"text":386,"correct":22},"一个操作按钮和一个状态指示灯",{"key":28,"text":388,"correct":22},"两个操作按钮和两个状态指示灯",{"key":31,"text":390,"correct":22},"两个操作按钮和一个状态指示灯",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":20,"analysis":33},974180,"在（ ）状态下，工作指示灯处于绿灯运行状态，通过总线控制盘可以手动启动火灾声光警报器、消防广播、加压送风口、加压送风机排烟阀、排烟机，释放防火卷帘，关闭常开型防火门，切断非消防电源和迫降电梯等。",[395,397,399,401],{"key":20,"text":396,"correct":26},"“允许”状态",{"key":24,"text":398,"correct":22},"“禁止”状态",{"key":28,"text":400,"correct":22},"\"启动”状态",{"key":31,"text":402,"correct":22},"“反馈”状态",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":24,"analysis":33},974181,"在（ ）状态下，工作指示灯处于红灯运行状态，不能通过多线控制盘手动直接启动消防泵组、防烟和排烟风机等设备。",[407,409,411,413],{"key":20,"text":408,"correct":22},"“允许”",{"key":24,"text":410,"correct":26},"“禁止”",{"key":28,"text":412,"correct":22},"“启动”",{"key":31,"text":414,"correct":22},"“反馈”",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":31,"analysis":33},974182,"如果（ ）处于熄灭状态，表示多线控制盘功能处于正常状态。",[419,421,423,425],{"key":20,"text":420,"correct":22},"“允许”指示灯",{"key":24,"text":422,"correct":22},"“禁止”指示灯",{"key":28,"text":424,"correct":22},"“启动”指示灯",{"key":31,"text":426,"correct":26},"“故障”指示灯",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":31,"analysis":33},974183,"线型光束感烟火灾探测器是指应用光束被烟雾粒子吸收而（ ）的原理探测火灾的线型感烟探测器。",[431,433,435,437],{"key":20,"text":432,"correct":22},"变小",{"key":24,"text":434,"correct":22},"变大",{"key":28,"text":436,"correct":22},"加强",{"key":31,"text":438,"correct":26},"减弱",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":31,"analysis":33},974184,"线型感温火灾探测器按（ ）可分为可恢复式和不可恢复式。",[443,445,447,449],{"key":20,"text":444,"correct":22},"动作性能",{"key":24,"text":446,"correct":22},"敏感部件形式",{"key":28,"text":448,"correct":22},"定位方式",{"key":31,"text":450,"correct":26},"可恢复性能",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":24,"analysis":33},974185,"线型感温火灾探测器按（ ）可分为探测型和探测报警型。",[455,456,458,459],{"key":20,"text":444,"correct":22},{"key":24,"text":457,"correct":26},"探测报警功能",{"key":28,"text":448,"correct":22},{"key":31,"text":450,"correct":22},{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":24,"analysis":33},974186,"下列不属于线型感温火灾探测器的设置要求（ ）。",[464,466,468,470],{"key":20,"text":465,"correct":22},"探测器在保护电缆、堆垛等类似保护对象时，应采用接触式布置",{"key":24,"text":467,"correct":26},"探测器应设置在固定结构上",{"key":28,"text":469,"correct":22},"设置线型感温火灾探测器的场所有联动要求时，宜采用两只不同火灾探测器的报警信号组合",{"key":31,"text":471,"correct":22},"探测器的保护半径应符合点型感温火灾探测器的保护半径要求",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":28,"analysis":33},974187,"下列关于火灾显示盘的说法不正确的是（ ）。",[476,478,480,482],{"key":20,"text":477,"correct":22},"火灾显示盘，又称区域显示器、楼层显示器",{"key":24,"text":479,"correct":22},"火灾显示盘按显示方式分为数字式、汉字\u002F英文式、图形式三种",{"key":28,"text":481,"correct":26},"直流供电型火灾显示盘通常采用DC36V，由火灾报警控制器或独立的消防应急电源来供电",{"key":31,"text":483,"correct":22},"交流供电型火灾显示盘由交流电源供电，具有主\u002F备电自动转换、备用电源自动充电、电源故障监测和电源工作状态指示等功能",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":28,"analysis":33},974188,"火灾显示盘应设置在出入口等明显和便于操作的部位。当采用壁挂方式安装时，其底边距地高度宜为（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":22},"1.0m～1.5m",{"key":24,"text":491,"correct":22},"1.0m～1.3m",{"key":28,"text":493,"correct":26},"1.3m～1.5m",{"key":31,"text":495,"correct":22},"1.5m～1.8m",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":24,"analysis":33},974189,"火灾显示盘应能接收与其连接的火灾报警控制器发出的火灾报警信号，并在火灾报警控制器发出火灾报警信号后（ ）s内发出火灾报警声、光信号，显示火灾发生部位。",[500,502,504,506],{"key":20,"text":501,"correct":22},"1",{"key":24,"text":503,"correct":26},"3",{"key":28,"text":505,"correct":22},"5",{"key":31,"text":507,"correct":22},"10",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":33},974190,"具有接收火灾报警控制器传来的火灾探测器、手动火灾报警按钮及其他火灾报警触发器件的故障信号功能的火灾显示盘，应在火灾报警控制器发出故障信号后（ ）s内发出故障声、光信号，并指示故障发生部位。",[512,513,514,515],{"key":20,"text":501,"correct":22},{"key":24,"text":503,"correct":26},{"key":28,"text":505,"correct":22},{"key":31,"text":507,"correct":22},{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":28,"analysis":33},974191,"采用主电源为220V、50Hz交流电源供电的火灾显示盘主电源应能保证火灾显示盘在火灾报警状态下连续工作（ ）h，且应有过流保护措施。",[520,522,523,525],{"key":20,"text":521,"correct":22},"2",{"key":24,"text":503,"correct":22},{"key":28,"text":524,"correct":26},"4",{"key":31,"text":505,"correct":22},{"id":527,"libraryId":5,"type":136,"typeLabel":137,"stem":528,"options":529,"answer":538,"analysis":33},974192,"在火灾报警控制器上，按下“复位”键，对操作信息显示描述正确的是（ ）。",[530,532,534,536],{"key":20,"text":531,"correct":26},"清除当前的所有火警、故障和反馈等显示",{"key":24,"text":533,"correct":26},"复位所有总线制被控设备和手动消防启动盘、多线制消防联动控制盘上的状态指示灯",{"key":28,"text":535,"correct":26},"清除正处于请求和延时请求启动的命令；清除消音状态",{"key":31,"text":537,"correct":22},"清除屏蔽信息","ABC",{"id":540,"libraryId":5,"type":136,"typeLabel":137,"stem":541,"options":542,"answer":551,"analysis":33},974193,"在火灾报警控制器上，设置手\u002F自动模式，对操作信息显示描述正确的是：（ ）。",[543,545,547,549],{"key":20,"text":544,"correct":26},"手动允许时，面板上的“手动允许”灯点亮，只有控制器处于“手动允许”的状态下，才能发出手动启动命令",{"key":24,"text":546,"correct":26},"自动方式是指满足联动条件后，系统自动进行的联动操作",{"key":28,"text":548,"correct":22},"只有全部自动允许时，面板上的“自动允许”灯才亮",{"key":31,"text":550,"correct":26},"控制器只有处于自动允许的状态下，才能发出自动联动启动命令","ABD",{"id":553,"libraryId":5,"type":136,"typeLabel":137,"stem":554,"options":555,"answer":151,"analysis":33},974194,"下列场所或部位，宜选择缆式线型感温火灾探测器（ ）。",[556,558,560,562,564],{"key":20,"text":557,"correct":26},"电缆隧道、电缆竖井、电缆夹层、电缆桥架",{"key":24,"text":559,"correct":26},"不易安装点型探测器的夹层、闷顶",{"key":28,"text":561,"correct":26},"各种皮带输送装置",{"key":31,"text":563,"correct":26},"其他环境恶劣不适合点型探测器安装的场所",{"key":149,"text":565,"correct":22},"有大量粉尘、水雾滞留",[567,570,573,576,579,582],{"id":15,"name":568,"category":7,"favorite":569},"领导干部任职前廉政法规知识测试题",92,{"id":571,"name":572,"category":7,"favorite":15},595,"建筑结构与设备",{"id":574,"name":575,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":577,"name":578,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":580,"name":581,"category":7,"favorite":8},534,"BIM工程师",{"id":583,"name":581,"category":7,"favorite":8},535]