[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-24":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":523},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,24,50,2486,[13,28,34,40,56,68,80,92,104,122,135,149,164,170,182,197,212,218,230,242,248,254,260,275,281,287,293,299,313,326,332,342,350,361,372,384,390,402,414,422,434,444,456,470,476,482,488,497,503,517],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},974095,3,"判断题","火灾探测器及其他火灾报警触发器件触发后，集中火灾报警控制器能直接或间接地接收来自火灾探测器及其他火灾报警触发器件的火灾报警信号，发出火灾报警声、光信号，指示火灾发生部位，记录火灾报警时间，并予以保持，直至自动复位。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},974096,"对于联动型火灾报警控制器，有时也把压力开关、水流指示器、信号蝶阀等传递的信号设为监管信号。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},974097,"当集中火灾报警控制器内部、控制器与其连接的部件间发生故障时，控制器能在10s内发出与火灾报警信号有明显区别的故障声、光信号，指示系统故障。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":42,"typeLabel":43,"stem":44,"options":45,"answer":20,"analysis":27},974098,1,"单选题","下列不属于集中报警系统的组成部分的是（ ）。",[46,48,50,53],{"key":20,"text":47,"correct":26},"电气控制柜",{"key":24,"text":49,"correct":22},"手动火灾报警按钮",{"key":51,"text":52,"correct":22},"C","消防控制室图形显示装置",{"key":54,"text":55,"correct":22},"D","消防应急广播",{"id":57,"libraryId":5,"type":42,"typeLabel":43,"stem":58,"options":59,"answer":20,"analysis":27},974099,"当集中火灾报警控制器内部、控制器与其连接的部件间发生故障时，控制器能在（ ）内发出与火灾报警信号有明显区别的故障声、光信号，指示系统故障。",[60,62,64,66],{"key":20,"text":61,"correct":26},"100s",{"key":24,"text":63,"correct":22},"30s",{"key":51,"text":65,"correct":22},"10s",{"key":54,"text":67,"correct":22},"3s",{"id":69,"libraryId":5,"type":42,"typeLabel":43,"stem":70,"options":71,"answer":20,"analysis":27},974100,"误报排除后应经单位消防安全管理人检查确认，维修情况应记入（ ）。",[72,74,76,78],{"key":20,"text":73,"correct":26},"《建筑消防设施故障维修记录表》",{"key":24,"text":75,"correct":22},"《消防值班记录表》",{"key":51,"text":77,"correct":22},"《消防巡查记录表》",{"key":54,"text":79,"correct":22},"《消防月度检查记录表》",{"id":81,"libraryId":5,"type":42,"typeLabel":43,"stem":82,"options":83,"answer":20,"analysis":27},974101,"在消防控制图形显示装置（CRT）中，点击“消音”键，可消除图形显示装置的（ ）。",[84,86,88,90],{"key":20,"text":85,"correct":26},"火警或故障警报声",{"key":24,"text":87,"correct":22},"火警或反馈声",{"key":51,"text":89,"correct":22},"反馈或故障警报声",{"key":54,"text":91,"correct":22},"监管或故障警报声",{"id":93,"libraryId":5,"type":42,"typeLabel":43,"stem":94,"options":95,"answer":20,"analysis":27},974102,"断开集中火灾报警控制器和火灾探测器之间连接线，使集中火灾报警控制器处于（ ）。",[96,98,100,102],{"key":20,"text":97,"correct":26},"故障状态",{"key":24,"text":99,"correct":22},"火警状态",{"key":51,"text":101,"correct":22},"正常状态",{"key":54,"text":103,"correct":22},"屏蔽状态",{"id":105,"libraryId":5,"type":106,"typeLabel":107,"stem":108,"options":109,"answer":121,"analysis":27},974103,2,"多选题","接通电源后，集中火灾报警控制器根据系统状况可以发出（ ）等信号。",[110,112,114,116,118],{"key":20,"text":111,"correct":26},"火警",{"key":24,"text":113,"correct":26},"联动",{"key":51,"text":115,"correct":26},"监管",{"key":54,"text":117,"correct":26},"故障报警",{"key":119,"text":120,"correct":26},"E","屏蔽","ABCDE",{"id":123,"libraryId":5,"type":106,"typeLabel":107,"stem":124,"options":125,"answer":134,"analysis":27},974104,"下列属于集中火灾报警系统的组成部分包括的有（ ）。",[126,127,128,130,132],{"key":20,"text":47,"correct":22},{"key":24,"text":55,"correct":26},{"key":51,"text":129,"correct":26},"集中火灾报警控制器",{"key":54,"text":131,"correct":26},"消防联动控制器",{"key":119,"text":133,"correct":26},"消防专用电话","BCDE",{"id":136,"libraryId":5,"type":106,"typeLabel":107,"stem":137,"options":138,"answer":148,"analysis":27},974105,"下列属于常用火灾报警触发设备的有（ ）。",[139,141,142,144,146],{"key":20,"text":140,"correct":26},"感烟感温探测器",{"key":24,"text":49,"correct":26},{"key":51,"text":143,"correct":26},"红外火焰探测器",{"key":54,"text":145,"correct":22},"火灾声光报警器",{"key":119,"text":147,"correct":22},"应急广播","ABC",{"id":150,"libraryId":5,"type":106,"typeLabel":107,"stem":151,"options":152,"answer":163,"analysis":27},974106,"下列属于常用火灾监管设备的有（ ）。",[153,155,157,159,161],{"key":20,"text":154,"correct":26},"压力开关",{"key":24,"text":156,"correct":22},"防火阀",{"key":51,"text":158,"correct":26},"水流指示器",{"key":54,"text":160,"correct":26},"信号蝶阀",{"key":119,"text":162,"correct":22},"排烟防火阀","ACD",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":21,"analysis":27},974107,"火灾报警系统由火灾探测器、手动火灾报警按钮、火灾声光警报器、消防应急广播、消防专用电话、消防控制室图形显示装置、集中火灾报警控制器、消防联动控制器等组成。",[168,169],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":171,"libraryId":5,"type":42,"typeLabel":43,"stem":172,"options":173,"answer":54,"analysis":27},974108,"检查判断排烟防火阀的工作状态时，需测试排烟防火阀的现场关闭功能和复位功能。下列操作顺序正确的是（ ）。",[174,176,178,180],{"key":20,"text":175,"correct":22},"1-2-3-4",{"key":24,"text":177,"correct":22},"2-3-1-4",{"key":51,"text":179,"correct":22},"3-1-4-3",{"key":54,"text":181,"correct":26},"1-4-2-3",{"id":183,"libraryId":5,"type":106,"typeLabel":107,"stem":184,"options":185,"answer":196,"analysis":27},974109,"检查判断排烟系统管道的工作状态时，应检查排烟防火阀的安装情况。下列需要安装排烟防火阀的部位是（ ）。",[186,188,190,192,194],{"key":20,"text":187,"correct":26},"垂直风管与每层水平风管交接处的水平管段上",{"key":24,"text":189,"correct":26},"一个排烟系统负担多个防烟分区的排烟支管上",{"key":51,"text":191,"correct":26},"排烟风机入口处",{"key":54,"text":193,"correct":22},"穿越防火隔墙处",{"key":119,"text":195,"correct":26},"穿越防火分区处","ABCE",{"id":198,"libraryId":5,"type":106,"typeLabel":107,"stem":199,"options":200,"answer":211,"analysis":27},974110,"下列建筑中，其防烟楼梯间可以设自然通风方式的防烟系统的是（ ）。",[201,203,205,207,209],{"key":20,"text":202,"correct":26},"建筑高度≤50m的公共建筑",{"key":24,"text":204,"correct":26},"建筑高度≤50m的工业建筑",{"key":51,"text":206,"correct":22},"建筑高度≤100m的工业建筑",{"key":54,"text":208,"correct":22},"建筑高度≤100m的公共建筑",{"key":119,"text":210,"correct":26},"建筑高度≤100m的住宅建筑","ABE",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":25,"analysis":27},974111,"当可燃气体探测器探测到可燃气体浓度值大于或等于相应报警浓度设定值时，控制器面板上相应的可燃气体探测器黄色报警灯长亮，蜂鸣器长鸣，系统发出声光报警信号，系统报警输出（继电器动作）报警锁定。（ ）",[216,217],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":219,"libraryId":5,"type":42,"typeLabel":43,"stem":220,"options":221,"answer":20,"analysis":27},974112,"集中火灾报警控制断开集中火灾报警控制器和火灾探测器之间连接线，使集中火灾报警控制器处于故障状态。此时灯键指示板上的（ ）亮。",[222,224,226,228],{"key":20,"text":223,"correct":26},"故障灯",{"key":24,"text":225,"correct":22},"联动灯",{"key":51,"text":227,"correct":22},"监管灯",{"key":54,"text":229,"correct":22},"屏蔽灯",{"id":231,"libraryId":5,"type":42,"typeLabel":43,"stem":232,"options":233,"answer":24,"analysis":27},974113,"集中火灾报警控制器在火灾报警状态下应有火灾声和\u002F或光警报器控制输出，还可设置其他控制输出，这属于集中火灾报警控制器的（ ）功能。",[234,236,238,240],{"key":20,"text":235,"correct":22},"火灾报警功能",{"key":24,"text":237,"correct":26},"火灾报警控制功能",{"key":51,"text":239,"correct":22},"故障报警功能",{"key":54,"text":241,"correct":22},"图形显示功能",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":25,"analysis":27},974114,"消防联动控制器的总线上有设备处于隔离状态时，屏蔽指示灯为红色。（ ）",[246,247],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":21,"analysis":27},974115,"报警阀、压力开关、水力警铃的检查，宜与末端试水装置的检查合并进行；当利用报警阀泄水阀进行检查时，系统侧管路控制阀宜关闭，检查完毕后恢复开启状态。（ ）",[252,253],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":25,"analysis":27},974116,"当集中火灾报警控制器内部、控制器与其连接的部件间发生故障时，控制器应能显示故障部位、故障类型等所有故障信息，这属于集中火灾报警控制器的自检功能。（ ）",[258,259],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":261,"libraryId":5,"type":106,"typeLabel":107,"stem":262,"options":263,"answer":274,"analysis":27},974117,"电气火灾监控系统主要包括（ ）。",[264,266,268,270,272],{"key":20,"text":265,"correct":26},"电气火灾监控设备",{"key":24,"text":267,"correct":26},"剩余电流式电气火灾监控探测器",{"key":51,"text":269,"correct":26},"测温式电气火灾监控探测器",{"key":54,"text":271,"correct":26},"图形显示装置",{"key":119,"text":273,"correct":22},"可燃气体探测器","ABCD",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":25,"analysis":27},974118,"断开集中火灾报警控制器和火灾探测器之间连接线，会使集中火灾报警控制器处于屏蔽状态。（ ）",[279,280],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":25,"analysis":27},974119,"火灾报警控制器是消防联动控制系统的核心组件。（ ）",[285,286],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":25,"analysis":27},974120,"火灾自动报警系统工作状态下的文字都是以黑色显示。（ ）",[291,292],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":21,"analysis":27},974121,"火灾自动报警系统控制器的电源工作状态分为主电工作状态和备电工作状态。（ ）",[297,298],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":300,"libraryId":5,"type":106,"typeLabel":107,"stem":301,"options":302,"answer":148,"analysis":27},974122,"火灾自动报警系统中，指示灯亮时应为红色的是（ ）。",[303,305,307,309,311],{"key":20,"text":304,"correct":26},"火警指示灯",{"key":24,"text":306,"correct":26},"反馈指示灯",{"key":51,"text":308,"correct":26},"气体喷洒指示灯",{"key":54,"text":310,"correct":22},"输出禁止指示灯",{"key":119,"text":312,"correct":22},"系统故障指示灯",{"id":314,"libraryId":5,"type":106,"typeLabel":107,"stem":315,"options":316,"answer":196,"analysis":27},974123,"机械加压送风系统的组件主要包括（ ）。",[317,319,321,323,325],{"key":20,"text":318,"correct":26},"送风机",{"key":24,"text":320,"correct":26},"送风口",{"key":51,"text":322,"correct":26},"风道",{"key":54,"text":324,"correct":22},"挡烟垂壁",{"key":119,"text":47,"correct":26},{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":25,"analysis":27},974124,"集中火灾报警控制器对火灾探测器等设备不可以进行单独屏蔽、解除屏蔽（取消屏蔽、释放）操作。当屏蔽后，控制器可以指示屏蔽部位。（ ）",[330,331],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":333,"libraryId":5,"type":42,"typeLabel":43,"stem":334,"options":335,"answer":51,"analysis":27},974125,"集中火灾报警系统的组成不包括（ ）。",[336,338,340,341],{"key":20,"text":337,"correct":22},"火灾探测器",{"key":24,"text":339,"correct":22},"手动报警按钮",{"key":51,"text":158,"correct":26},{"key":54,"text":52,"correct":22},{"id":343,"libraryId":5,"type":42,"typeLabel":43,"stem":344,"options":345,"answer":20,"analysis":27},974126,"集中火灾报警系统中，常用火灾监管设备不包括（ ）。",[346,347,348,349],{"key":20,"text":339,"correct":26},{"key":24,"text":154,"correct":22},{"key":51,"text":158,"correct":22},{"key":54,"text":160,"correct":22},{"id":351,"libraryId":5,"type":42,"typeLabel":43,"stem":352,"options":353,"answer":54,"analysis":27},974127,"可燃气体报警控制器的功能不包括（ ）。",[354,356,358,359],{"key":20,"text":355,"correct":22},"监控",{"key":24,"text":357,"correct":22},"报警",{"key":51,"text":117,"correct":22},{"key":54,"text":360,"correct":26},"隔离保护",{"id":362,"libraryId":5,"type":42,"typeLabel":43,"stem":363,"options":364,"answer":24,"analysis":27},974128,"末端试水装置的组成不包括（ ）。",[365,367,368,370],{"key":20,"text":366,"correct":22},"试水阀",{"key":24,"text":154,"correct":26},{"key":51,"text":369,"correct":22},"压力表",{"key":54,"text":371,"correct":22},"试水接头",{"id":373,"libraryId":5,"type":42,"typeLabel":43,"stem":374,"options":375,"answer":51,"analysis":27},974129,"排烟管道隔热材料应为不燃材料，且与可燃物保持不小于（ ）mm的距离。",[376,378,380,382],{"key":20,"text":377,"correct":22},"50",{"key":24,"text":379,"correct":22},"100",{"key":51,"text":381,"correct":26},"150",{"key":54,"text":383,"correct":22},"250",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":25,"analysis":27},974130,"排烟系统是通过采用自然通风方式，防止火灾烟气在楼梯间、前室、避难层（间）等空间内积聚，或通过采用机械加压送风方式阻止火灾烟气侵入楼梯间、前室、避难层（间）等空间的系统。（ ）",[388,389],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":391,"libraryId":5,"type":42,"typeLabel":43,"stem":392,"options":393,"answer":20,"analysis":27},974131,"湿式自动喷水灭火系统应采用（ ）报警阀组。",[394,396,398,400],{"key":20,"text":395,"correct":26},"湿式",{"key":24,"text":397,"correct":22},"干式",{"key":51,"text":399,"correct":22},"预作用",{"key":54,"text":401,"correct":22},"雨淋",{"id":403,"libraryId":5,"type":42,"typeLabel":43,"stem":404,"options":405,"answer":51,"analysis":27},974132,"下列建筑中，必须设机械排烟系统的是（ ）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"建筑高度为50m的公共建筑",{"key":24,"text":409,"correct":22},"建筑高度为50m的住宅建筑",{"key":51,"text":411,"correct":26},"建筑高度为100m的工业建筑",{"key":54,"text":413,"correct":22},"建筑高度为100m的农业建筑",{"id":415,"libraryId":5,"type":42,"typeLabel":43,"stem":416,"options":417,"answer":20,"analysis":27},974133,"下列图片中，（ ）是延迟器。",[418,419,420,421],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":51,"text":51,"correct":22},{"key":54,"text":54,"correct":22},{"id":423,"libraryId":5,"type":42,"typeLabel":43,"stem":424,"options":425,"answer":54,"analysis":27},974134,"下列选项中，（ ）不属于消防控制室图形显示装置的功能。",[426,428,430,432],{"key":20,"text":427,"correct":22},"传输、接收、显示和记录保护区域内的火灾探测器信息",{"key":24,"text":429,"correct":22},"传输、接收、显示和记录系统中各消防设备（设施）运行的动态信息",{"key":51,"text":431,"correct":22},"传输、接收、显示和记录系统中的消防管理信息",{"key":54,"text":433,"correct":26},"按预定逻辑对建筑中设置的自动消防系统（设施）进行联动控制",{"id":435,"libraryId":5,"type":42,"typeLabel":43,"stem":436,"options":437,"answer":20,"analysis":27},974135,"下列选项中，（ ）不属于消防控制室图形显示装置的主要功能。",[438,439,440,442],{"key":20,"text":235,"correct":26},{"key":24,"text":241,"correct":22},{"key":51,"text":441,"correct":22},"故障状态显示",{"key":54,"text":443,"correct":22},"通信故障报警功能",{"id":445,"libraryId":5,"type":42,"typeLabel":43,"stem":446,"options":447,"answer":24,"analysis":27},974136,"下图属于自动喷水灭火系统的（ ）组件。",[448,450,452,454],{"key":20,"text":449,"correct":22},"开式喷头",{"key":24,"text":451,"correct":26},"闭式喷头",{"key":51,"text":453,"correct":22},"感温火灾探测器",{"key":54,"text":455,"correct":22},"感烟火灾探测器",{"id":457,"libraryId":5,"type":106,"typeLabel":107,"stem":458,"options":459,"answer":274,"analysis":27},974137,"消防供水设施通常包括（ ），主要用于为自动喷水灭火系统提供水量和水压保证，是自动喷水灭火系统的重要组成部分。",[460,462,464,466,468],{"key":20,"text":461,"correct":26},"消防水泵接合器",{"key":24,"text":463,"correct":26},"高位消防水箱",{"key":51,"text":465,"correct":26},"增（稳）压设施",{"key":54,"text":467,"correct":26},"消防水泵",{"key":119,"text":469,"correct":22},"末端试水装置",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":21,"analysis":27},974138,"消防联动控制器的电源部分应具有主电源和备用电源转换装置。（ ）",[474,475],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":25,"analysis":27},974139,"消防联动控制器联网本机有信号发送时，本机发送指示灯为绿色。（ ）",[480,481],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":25,"analysis":27},974140,"消防设备电源末端切换就是消防设备的两个电源相互切换，互为备用电源的一种供电形式。其中一个作为主电源另一个作为备用电源，当主电源损坏或故障时备用电源通过末端切换装置手动投入使用。（ ）",[486,487],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":489,"libraryId":5,"type":42,"typeLabel":43,"stem":490,"options":491,"answer":54,"analysis":27},974141,"在电气火灾监控系统中，（ ）是能够区分低压配电线路中操作正常电弧和故障电弧，消除电气火灾隐患的电气火灾监控探测器。",[492,493,494,495],{"key":20,"text":265,"correct":22},{"key":24,"text":267,"correct":22},{"key":51,"text":269,"correct":22},{"key":54,"text":496,"correct":26},"故障电弧探测器",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":25,"analysis":27},974142,"在集中火灾报警控制器控制面板显示屏上点击“设备操作”，可以查看所有的火警信息。（ ）",[501,502],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":504,"libraryId":5,"type":106,"typeLabel":107,"stem":505,"options":506,"answer":148,"analysis":27},974143,"在集中火灾报警系统中可以通过下列（ ）方式查看报警信息和确定报警部位。",[507,509,511,513,515],{"key":20,"text":508,"correct":26},"通过信息列表查看",{"key":24,"text":510,"correct":26},"通过“火警监管”查看",{"key":51,"text":512,"correct":26},"通过消防控制室图形显示装置查看",{"key":54,"text":514,"correct":22},"通过摄像头查看",{"key":119,"text":516,"correct":22},"现场查看",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":25,"analysis":27},974144,"在湿式和干式自动喷水灭火系统中，开式喷头担负着探测火灾、启动系统和喷水灭火的任务，其喷水口平时由热敏感元件组成的释放机构封闭，火灾发生时受热开启。（ ）",[521,522],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},[524,527,530,533,536,539],{"id":42,"name":525,"category":7,"favorite":526},"领导干部任职前廉政法规知识测试题",92,{"id":528,"name":529,"category":7,"favorite":42},595,"建筑结构与设备",{"id":531,"name":532,"category":7,"favorite":42},715,"招标采购专业知识与法律法规",{"id":534,"name":535,"category":7,"favorite":42},848,"市政方向-通用基础",{"id":537,"name":538,"category":7,"favorite":8},534,"BIM工程师",{"id":540,"name":538,"category":7,"favorite":8},535]