[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-23":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":504},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,23,50,2486,[13,34,43,53,65,76,84,96,108,117,129,141,153,165,177,189,201,213,225,243,257,272,286,301,316,327,337,343,349,355,361,367,373,379,385,391,397,403,409,415,421,427,433,439,445,451,457,469,481,489],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},974045,1,"单选题","在火灾报警控制器上，（ ）灯亮，表示控制器处于不能正常使用的故障状态。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","火警",false,{"key":24,"text":25,"correct":22},"B","启动",{"key":27,"text":28,"correct":22},"C","反馈",{"key":30,"text":31,"correct":32},"D","系统故障",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":30,"analysis":33},974046,"在火灾报警控制器上，（ ）亮，表示有设备处于被屏蔽状态。",[38,39,40,41],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":22},{"key":27,"text":28,"correct":22},{"key":30,"text":42,"correct":32},"屏蔽",{"id":44,"libraryId":5,"type":15,"typeLabel":16,"stem":45,"options":46,"answer":27,"analysis":33},974047,"在火灾报警控制器上，（ ）灯亮，表示当前控制器由备电源供电。",[47,48,50,52],{"key":20,"text":21,"correct":22},{"key":24,"text":49,"correct":22},"主电工作",{"key":27,"text":51,"correct":32},"备电工作",{"key":30,"text":42,"correct":22},{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":24,"analysis":33},974048,"在图形显示装置（CRT）信息指示部分中的说明中，（ ）亮：表示图形显示装置与火灾报警控制器处于连接状态。",[57,59,61,63],{"key":20,"text":58,"correct":22},"火警指示",{"key":24,"text":60,"correct":32},"通讯指示",{"key":27,"text":62,"correct":22},"反馈指示",{"key":30,"text":64,"correct":22},"监管指示",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":24,"analysis":33},974049,"在图形显示装置（CRT）信息指示部分中的说明中，（ ）亮，表示火灾报警控制器或其所连接的设备处于不能正常使用的故障状态。",[69,71,73,74],{"key":20,"text":70,"correct":22},"屏蔽指示",{"key":24,"text":72,"correct":32},"故障指示",{"key":27,"text":62,"correct":22},{"key":30,"text":75,"correct":22},"监管",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":20,"analysis":33},974050,"在图形显示装置（CRT）信息指示部分中的说明中，（ ）亮，表示有设备处于被屏蔽状态，此时报警系统中被屏蔽设备的功能丧失。",[80,81,82,83],{"key":20,"text":70,"correct":32},{"key":24,"text":60,"correct":22},{"key":27,"text":62,"correct":22},{"key":30,"text":75,"correct":22},{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":27,"analysis":33},974051,"火灾报警控制器（联动型）在（ ）状态下，只要接收到满足预设联动逻辑关系的报警信号，控制器发出联动启动命令，并接收动作反馈信号。",[88,90,92,94],{"key":20,"text":89,"correct":22},"正常监视",{"key":24,"text":91,"correct":22},"报警",{"key":27,"text":93,"correct":32},"联动控制",{"key":30,"text":95,"correct":22},"正常工作",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":27,"analysis":33},974052,"在火灾报警系统中，应急广播控制器（ ）灯亮，表示正在录音。",[100,102,104,106],{"key":20,"text":101,"correct":22},"工作指示",{"key":24,"text":103,"correct":22},"话筒指示",{"key":27,"text":105,"correct":32},"录音指示",{"key":30,"text":107,"correct":22},"支线故障指示",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":20,"analysis":33},974053,"在火灾报警控制器上，（ ）灯亮，表示控制器检测到外部设备（探测器、模块或火灾显示盘）有故障，或控制器本身出现故障。",[112,114,115,116],{"key":20,"text":113,"correct":32},"故障",{"key":24,"text":49,"correct":22},{"key":27,"text":51,"correct":22},{"key":30,"text":42,"correct":22},{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":30,"analysis":33},974054,"火灾报警控制器或系统内各组成部分发生故障时所处的状态是（ ）。",[121,123,125,127],{"key":20,"text":122,"correct":22},"正常监视状态",{"key":24,"text":124,"correct":22},"自检状态",{"key":27,"text":126,"correct":22},"屏蔽状态",{"key":30,"text":128,"correct":32},"故障报警状态",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":30,"analysis":33},974055,"信息显示与查询功能：控制器信息显示按（ ）及其他状态顺序由高至低排列信息显示等级。",[133,135,137,139],{"key":20,"text":134,"correct":22},"故障报警、屏蔽",{"key":24,"text":136,"correct":22},"故障报警、监管报警",{"key":27,"text":138,"correct":22},"报警控制、启动",{"key":30,"text":140,"correct":32},"火灾报警、监管报警",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":30,"analysis":33},974056,"为使火灾自动报警系统或系统内各组成部分恢复到正常监视状态进行的操作是（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"联动",{"key":24,"text":148,"correct":22},"自检",{"key":27,"text":150,"correct":22},"消音",{"key":30,"text":152,"correct":32},"复位",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":27,"analysis":33},974057,"下列建筑的部位不用安装排烟系统的是（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":22},"房间",{"key":24,"text":160,"correct":22},"走道",{"key":27,"text":162,"correct":32},"楼梯间",{"key":30,"text":164,"correct":22},"中庭",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":20,"analysis":33},974058,"下列不属于机械排烟系统的组成部分的是（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":32},"电气控制柜",{"key":24,"text":172,"correct":22},"排烟防火阀",{"key":27,"text":174,"correct":22},"排烟风机",{"key":30,"text":176,"correct":22},"排烟道",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":24,"analysis":33},974059,"排烟管道隔热材料应为不燃材料，且与可燃物保持不小于（ ）的距离。",[181,183,185,187],{"key":20,"text":182,"correct":22},"100mm",{"key":24,"text":184,"correct":32},"150mm",{"key":27,"text":186,"correct":22},"200mm",{"key":30,"text":188,"correct":22},"250mm",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":30,"analysis":33},974060,"下列不属于电气火灾监控系统组成的是（ ）。",[193,195,197,199],{"key":20,"text":194,"correct":22},"电气火灾监控设备",{"key":24,"text":196,"correct":22},"剩余电流式电气火灾监控探测器",{"key":27,"text":198,"correct":22},"故障电弧探测器",{"key":30,"text":200,"correct":32},"火灾声光警报器",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":30,"analysis":33},974061,"下列关于剩余电流式电气火灾监控探测器的设置说法正确的是（ ）。",[205,207,209,211],{"key":20,"text":206,"correct":22},"设置在低压配电系统末端为基本原则",{"key":24,"text":208,"correct":22},"设置在第一级配电柜（箱）的出线端",{"key":27,"text":210,"correct":22},"在供电线路泄漏电流大于500mA时，宜设置在末级配电柜（箱）",{"key":30,"text":212,"correct":32},"剩余电流式电气火灾监控探测器不宜设置在IT系统配电线路和消防配电线路中",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":20,"analysis":33},974062,"下列关于测温式电气火灾监控探测器的设置说法错误的是（ ）。",[217,219,221,223],{"key":20,"text":218,"correct":32},"是检测高压配电线路中线路温度的电气火灾监控探测器",{"key":24,"text":220,"correct":22},"应设置在电缆接头、端子、重点发热部件等部位",{"key":27,"text":222,"correct":22},"保护对象为1000V及以下的配电线路，测温式电气火灾监控探测器应采用接触式布置",{"key":30,"text":224,"correct":22},"保护对象为1000V以上的供电线路，测温式电气火灾监控探测器宜选择光栅光纤测温式或红外测温式电气火灾监控探测器",{"id":226,"libraryId":5,"type":227,"typeLabel":228,"stem":229,"options":230,"answer":242,"analysis":33},974063,2,"多选题","在消防控制室图形显示装置（CRT）中，对于报警状态信息显示描述正确的是：（ ）。",[231,233,235,237,239],{"key":20,"text":232,"correct":22},"报警指示：“火警”指示为红色，可以自动清除",{"key":24,"text":234,"correct":32},"声响音调：发出与其它信息不同的火警声",{"key":27,"text":236,"correct":32},"图形显示部分对应的报警设备以红色闪烁",{"key":30,"text":238,"correct":32},"通过查看文字信息能获得每一个火灾报警部位及相关信息",{"key":240,"text":241,"correct":32},"E","报警设备所在区域也以红色显示","BCDE",{"id":244,"libraryId":5,"type":227,"typeLabel":228,"stem":245,"options":246,"answer":242,"analysis":33},974064,"对消防控制室图形显示装置（CRT）描述中，下列图形显示装置的主要功能是（ ）。",[247,249,251,253,255],{"key":20,"text":248,"correct":22},"工程服务器客户端",{"key":24,"text":250,"correct":32},"图形显示部分",{"key":27,"text":252,"correct":32},"火灾报警和联动状态显示功能",{"key":30,"text":254,"correct":32},"通信故障报警功能",{"key":240,"text":256,"correct":32},"信息记录功能",{"id":258,"libraryId":5,"type":227,"typeLabel":228,"stem":259,"options":260,"answer":271,"analysis":33},974065,"根据系统的用途和配置情况，自动喷水灭火系统可分为（ ）等。",[261,263,265,267,269],{"key":20,"text":262,"correct":32},"重复启闭预作用系统",{"key":24,"text":264,"correct":22},"闭式系统",{"key":27,"text":266,"correct":32},"预作用系统",{"key":30,"text":268,"correct":32},"雨淋系统",{"key":240,"text":270,"correct":22},"开式系统","ACD",{"id":273,"libraryId":5,"type":227,"typeLabel":228,"stem":274,"options":275,"answer":242,"analysis":33},974066,"下列关于自动喷水灭火系统消防泵组及控制柜准工作状态要求的说法正确的有（ ）。",[276,278,280,282,284],{"key":20,"text":277,"correct":22},"电气控制柜平时应处于手动工作状态",{"key":24,"text":279,"correct":32},"各项切换功能正常",{"key":27,"text":281,"correct":32},"有关系统名称和编号的标识牢固、清晰、正确",{"key":30,"text":283,"correct":32},"消防水泵启停功能正常，供水能力测试",{"key":240,"text":285,"correct":32},"供电正常，仪表、指示好、开关按钮正常",{"id":287,"libraryId":5,"type":227,"typeLabel":228,"stem":288,"options":289,"answer":300,"analysis":33},974067,"检查判断自动喷水灭火系统的工作状态的方法包括（ ）。",[290,292,294,296,298],{"key":20,"text":291,"correct":32},"技术比对",{"key":24,"text":293,"correct":32},"组件外观检查",{"key":27,"text":295,"correct":22},"模拟火灾",{"key":30,"text":297,"correct":32},"分析判断",{"key":240,"text":299,"correct":32},"功能测试","ABDE",{"id":302,"libraryId":5,"type":227,"typeLabel":228,"stem":303,"options":304,"answer":315,"analysis":33},974068,"下列属于湿式自动喷水灭火系统组件的有（ ）。",[305,307,309,311,313],{"key":20,"text":306,"correct":22},"开式喷头",{"key":24,"text":308,"correct":32},"报警阀组",{"key":27,"text":310,"correct":32},"水流报警装置",{"key":30,"text":312,"correct":32},"管道和供水设施",{"key":240,"text":314,"correct":22},"加速排气装置","BCD",{"id":317,"libraryId":5,"type":227,"typeLabel":228,"stem":318,"options":319,"answer":242,"analysis":33},974069,"下列属于干式自动喷水灭火系统主要组成组件的的有（ ）。",[320,321,322,323,325],{"key":20,"text":306,"correct":22},{"key":24,"text":308,"correct":32},{"key":27,"text":312,"correct":32},{"key":30,"text":324,"correct":32},"充气和气压维持装置",{"key":240,"text":326,"correct":32},"水流指示器",{"id":328,"libraryId":5,"type":329,"typeLabel":330,"stem":331,"options":332,"answer":334,"analysis":33},974070,3,"判断题","备电工作灯：此灯亮表示控制器由备电供电。",[333,335],{"key":20,"text":334,"correct":32},"正确",{"key":24,"text":336,"correct":22},"错误",{"id":338,"libraryId":5,"type":329,"typeLabel":330,"stem":339,"options":340,"answer":334,"analysis":33},974071,"复位：是为使火灾自动报警系统或系统内各组成部分恢复到正常监视状态进行的操作。",[341,342],{"key":20,"text":334,"correct":32},{"key":24,"text":336,"correct":22},{"id":344,"libraryId":5,"type":329,"typeLabel":330,"stem":345,"options":346,"answer":334,"analysis":33},974072,"故障报警状态：表示火灾报警控制器的主备电或监控的现场设备等发生故障时所处的工作状态。",[347,348],{"key":20,"text":334,"correct":32},{"key":24,"text":336,"correct":22},{"id":350,"libraryId":5,"type":329,"typeLabel":330,"stem":351,"options":352,"answer":334,"analysis":33},974073,"火警灯：此灯亮表示控制器检测到外接探测器处于火警状态。",[353,354],{"key":20,"text":334,"correct":32},{"key":24,"text":336,"correct":22},{"id":356,"libraryId":5,"type":329,"typeLabel":330,"stem":357,"options":358,"answer":336,"analysis":33},974074,"监管灯：此灯亮表示控制器检测到了外部设备的火警报警信号。",[359,360],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":362,"libraryId":5,"type":329,"typeLabel":330,"stem":363,"options":364,"answer":334,"analysis":33},974075,"联动控制状态：当控制器处子“自动允许”的状态下，并且满足联动公式中的逻辑关系时，控制器发出自动联动启动命令，并接收反馈动作信号。",[365,366],{"key":20,"text":334,"correct":32},{"key":24,"text":336,"correct":22},{"id":368,"libraryId":5,"type":329,"typeLabel":330,"stem":369,"options":370,"answer":334,"analysis":33},974076,"图形显示装置（CRT）监视的火灾报警控制器以及监控的现场设备等发生故障时，图形显示装置（CRT）能够发出声、光报警。",[371,372],{"key":20,"text":334,"correct":32},{"key":24,"text":336,"correct":22},{"id":374,"libraryId":5,"type":329,"typeLabel":330,"stem":375,"options":376,"answer":336,"analysis":33},974077,"图形显示装置（CRT）能够接收到火灾报警控制器发送的火灾报警信号，但不具有发出声、光报警的功能。",[377,378],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":380,"libraryId":5,"type":329,"typeLabel":330,"stem":381,"options":382,"answer":334,"analysis":33},974078,"系统故障灯：此灯亮，表示控制器处于不能正常使用的故障状态，以提示用户立即对控制器进行修复。",[383,384],{"key":20,"text":334,"correct":32},{"key":24,"text":336,"correct":22},{"id":386,"libraryId":5,"type":329,"typeLabel":330,"stem":387,"options":388,"answer":334,"analysis":33},974079,"消音状态是火灾报警控制器接收到火灾报警或故障报警等信号井发出声、光报警信号时，按下“消音”键控制器所处的工作状态。",[389,390],{"key":20,"text":334,"correct":32},{"key":24,"text":336,"correct":22},{"id":392,"libraryId":5,"type":329,"typeLabel":330,"stem":393,"options":394,"answer":334,"analysis":33},974080,"在图形显示装置（CRT）中，火灾报警信息具有最高显示级别。",[395,396],{"key":20,"text":334,"correct":32},{"key":24,"text":336,"correct":22},{"id":398,"libraryId":5,"type":329,"typeLabel":330,"stem":399,"options":400,"answer":336,"analysis":33},974081,"正常监视状态：表示火灾报警控制器以及监控的现场设备均处于正常工作状态，允许火灾报警、故障报警、屏蔽、监管报警、消音、启动等信息在控制器显示屏上显示。",[401,402],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":404,"libraryId":5,"type":329,"typeLabel":330,"stem":405,"options":406,"answer":336,"analysis":33},974082,"电气火灾监控设备应能在10s内接收来自电气火灾监控探测器测量的剩余电流值和温度值，剩余电流值和温度值应可查询。",[407,408],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":410,"libraryId":5,"type":329,"typeLabel":330,"stem":411,"options":412,"answer":336,"analysis":33},974083,"电气监控设备应能对本机及所配接的电气火灾监控探测器进行功能检查。在执行自检期间，与其连接的外部外接设备继续工作，还应能手动检查其音响器件和面板上所有指示灯、显示器的工作状态。",[413,414],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":416,"libraryId":5,"type":329,"typeLabel":330,"stem":417,"options":418,"answer":336,"analysis":33},974084,"剩余电流式电气火灾监控探测器的剩余电流报警设定值范围为100-1000mA。",[419,420],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":422,"libraryId":5,"type":329,"typeLabel":330,"stem":423,"options":424,"answer":336,"analysis":33},974085,"测温式电气火灾监控探测器的温度报警设定值范围为50-140℃。",[425,426],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":428,"libraryId":5,"type":329,"typeLabel":330,"stem":429,"options":430,"answer":336,"analysis":33},974086,"当被探测线路在3s内发生14个及以上半周期的故障电弧时，故障电弧探测器应能在30s内发出报警信号，点亮报警指示灯，向电气火灾监控设备发送报警信号。",[431,432],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":434,"libraryId":5,"type":329,"typeLabel":330,"stem":435,"options":436,"answer":334,"analysis":33},974087,"可燃气体探测报警系统由可燃气体报警控制器、可燃气体探测器、图形显示装置和火灾声光警报器等组成。",[437,438],{"key":20,"text":334,"correct":32},{"key":24,"text":336,"correct":22},{"id":440,"libraryId":5,"type":329,"typeLabel":330,"stem":441,"options":442,"answer":336,"analysis":33},974088,"可燃气体探测器是可燃气体探测报警系统的核心控制单元。",[443,444],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":446,"libraryId":5,"type":329,"typeLabel":330,"stem":447,"options":448,"answer":336,"analysis":33},974089,"消防设备末端配电装置由配电箱、按钮、指示灯、断路器、电源线路等器件组成。",[449,450],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":452,"libraryId":5,"type":329,"typeLabel":330,"stem":453,"options":454,"answer":336,"analysis":33},974090,"建筑高度大于50m建筑，其防烟楼梯间、独立前室、共用前室、合用前室及消防电梯前室应采用机械加压送风系统",[455,456],{"key":20,"text":334,"correct":22},{"key":24,"text":336,"correct":32},{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":33},974091,"图形显示装置（CRT）接收到火灾报警控制器发送的火灾报警信号，火灾报警信息具有（ ）显示级别。",[461,463,465,467],{"key":20,"text":462,"correct":22},"—般",{"key":24,"text":464,"correct":32},"最高",{"key":27,"text":466,"correct":22},"高",{"key":30,"text":468,"correct":22},"最低",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":27,"analysis":33},974092,"在消防设施中，不能够起到对人员疏散作用的设备是（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":22},"声光火灾警报装置",{"key":24,"text":476,"correct":22},"火灾应急广播系统",{"key":27,"text":478,"correct":32},"消火栓系统",{"key":30,"text":480,"correct":22},"应急照明和疏散指示系统",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":30,"analysis":33},974093,"在火灾报警控制器上，（ ）检测到了外部设备的监管报警信号。",[485,486,487,488],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":22},{"key":27,"text":28,"correct":22},{"key":30,"text":75,"correct":32},{"id":490,"libraryId":5,"type":227,"typeLabel":228,"stem":491,"options":492,"answer":503,"analysis":33},974094,"下列关于自动喷水灭火系统报警阀组在准工作状态下的要求说法正确的有（ ）。",[493,495,497,499,501],{"key":20,"text":494,"correct":32},"湿式报警阀系统标识清晰，组件齐全，外观完好",{"key":24,"text":496,"correct":22},"主阀前后压力指示正常，表差＜0.02MPa，各项测试功能正常，排水正常报警阀、压力开关、水力警铃等动作正常",{"key":27,"text":498,"correct":32},"距水力警铃3m远处的警铃声强应不低于70dB",{"key":30,"text":500,"correct":32},"干式和预作用系统报警阀还应充气装置启停准确，充气压力值符合设计要求",{"key":240,"text":502,"correct":32},"加速排气装置排气速度正常，电磁阀动作灵敏间前稳压值符合设计要求","ACDE",[505,508,511,514,517,520],{"id":15,"name":506,"category":7,"favorite":507},"领导干部任职前廉政法规知识测试题",92,{"id":509,"name":510,"category":7,"favorite":15},595,"建筑结构与设备",{"id":512,"name":513,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":515,"name":516,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":518,"name":519,"category":7,"favorite":8},534,"BIM工程师",{"id":521,"name":519,"category":7,"favorite":8},535]