[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":616},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,21,50,2486,[13,34,42,54,66,78,89,101,113,125,137,146,156,168,177,187,199,208,219,231,243,255,267,279,291,303,315,327,339,350,362,371,379,387,396,406,418,427,445,460,475,487,501,515,530,545,559,573,587,601],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},973944,1,"单选题","在消防电话系统中，当有分机呼入时，（ ）红色灯闪亮。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","通话",false,{"key":24,"text":25,"correct":26},"B","呼叫",true,{"key":28,"text":29,"correct":22},"C","故障",{"key":31,"text":32,"correct":22},"D","工作","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},973945,"在消防电话系统中，当主机和分机处于通话状态时，（ ）红色灯常亮。",[38,39,40,41],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"key":28,"text":29,"correct":22},{"key":31,"text":32,"correct":22},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":20,"analysis":33},973946,"火灾报警控制器接通电源后，无火灾报警、故障报警、屏蔽监管报警等发生时，所处的状态是（ ）。",[46,48,50,52],{"key":20,"text":47,"correct":26},"正常监视状态",{"key":24,"text":49,"correct":22},"自检状态",{"key":28,"text":51,"correct":22},"屏蔽状态",{"key":31,"text":53,"correct":22},"监管状态",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":28,"analysis":33},973947,"在消防监控系统中，值班人员可以通过（ ），能够直观地了解消防工程设备分布情况。",[58,60,62,64],{"key":20,"text":59,"correct":22},"报警控制器主界面",{"key":24,"text":61,"correct":22},"电话联系",{"key":28,"text":63,"correct":26},"图形显示裝置监视主界面",{"key":31,"text":65,"correct":22},"查看现场",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":31,"analysis":33},973948,"在火灾报警控制器上，（ ）灯亮，表示系统中存在被屏蔽的声光警报器。",[70,72,74,76],{"key":20,"text":71,"correct":22},"反馈",{"key":24,"text":73,"correct":22},"警报器消音指示",{"key":28,"text":75,"correct":22},"声光警报器故障指示",{"key":31,"text":77,"correct":26},"声光警报器屏蔽指示",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":24,"analysis":33},973949,"在火灾报警控制器上（ ）灯亮，表示当满足联动条件后，系统自动对联动设备进行联动操作。",[82,83,85,87],{"key":20,"text":71,"correct":22},{"key":24,"text":84,"correct":26},"自动允许",{"key":28,"text":86,"correct":22},"备电工作",{"key":31,"text":88,"correct":22},"启动",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":20,"analysis":33},973950,"在消防控制室图形显示装置（CRT）中，点击“消音”键，可消除图形显示装置的（ ）。",[93,95,97,99],{"key":20,"text":94,"correct":26},"火警或故障警报声",{"key":24,"text":96,"correct":22},"火警或反馈声",{"key":28,"text":98,"correct":22},"反馈或故障警报声",{"key":31,"text":100,"correct":22},"监管或故障警报声",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":33},973951,"在火灾报警系统中，对于应急广播，手动启动的描述不正确的是（ ）。",[105,107,109,111],{"key":20,"text":106,"correct":26},"启动应急广播不需要密码直接进入",{"key":24,"text":108,"correct":22},"应急广播启动后应急广播灯点亮",{"key":28,"text":110,"correct":22},"按下应急广播键可以手动启动应急广播并选择区域",{"key":31,"text":112,"correct":22},"通过通播键可以选择全部可工作的区域",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":20,"analysis":33},973952,"火灾报警控制器大多时间处于（ ）状态。",[117,119,121,123],{"key":20,"text":118,"correct":26},"正常监视",{"key":24,"text":120,"correct":22},"故障报警",{"key":28,"text":122,"correct":22},"火灾报警",{"key":31,"text":124,"correct":22},"监管报警",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":28,"analysis":33},973953,"在火灾报警系统中，消防电话主界面信息特征，描述不正确的一项是（ ）。",[129,131,133,135],{"key":20,"text":130,"correct":22},"正常监视状态下，消防电话主机面板的“工作”指示灯常亮",{"key":24,"text":132,"correct":22},"自检后，显示屏显示开机画面",{"key":28,"text":134,"correct":26},"有故障信息时，“故障”指示灯常亮",{"key":31,"text":136,"correct":22},"系统运行正常时，本设备的液晶显示屏会一直显示待机画面",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":20,"analysis":33},973954,"在火灾报警控制器上，（ ）灯亮，表示控制器检测到外接被控设备的反馈信号。",[141,142,143,145],{"key":20,"text":71,"correct":26},{"key":24,"text":88,"correct":22},{"key":28,"text":144,"correct":22},"主电工作",{"key":31,"text":86,"correct":22},{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":31,"analysis":33},973955,"在火灾报警控制器上.（ ）灯亮，表示系统中存在处于自检状态的设备。",[150,151,153,154],{"key":20,"text":71,"correct":22},{"key":24,"text":152,"correct":22},"自动",{"key":28,"text":86,"correct":22},{"key":31,"text":155,"correct":26},"自检",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":20,"analysis":33},973956,"对消防控制室图形显示装置（CRT）描述中，以下不是主界面部分的是（ ）。",[160,162,164,166],{"key":20,"text":161,"correct":26},"工程服务器客户端",{"key":24,"text":163,"correct":22},"图形显示部分",{"key":28,"text":165,"correct":22},"信息指示部分",{"key":31,"text":167,"correct":22},"操作部分",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":20,"analysis":33},973957,"在火灾报警控制器上.（ ）灯亮，表示控制器检测到外部设备（探测器、模块或火灾显示盘）有故障，或控制器本身出现故障。",[172,173,174,175],{"key":20,"text":29,"correct":26},{"key":24,"text":144,"correct":22},{"key":28,"text":86,"correct":22},{"key":31,"text":176,"correct":22},"屏蔽",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":20,"analysis":33},973958,"在火灾报警控制器上.（ ）测到外接探测器处于火警状态。",[181,183,184,185],{"key":20,"text":182,"correct":26},"火警",{"key":24,"text":88,"correct":22},{"key":28,"text":71,"correct":22},{"key":31,"text":186,"correct":22},"监管",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":28,"analysis":33},973959,"在消防控制室应能控制正压送风系统的（ ）送风机等设备动作，并显示其反馈信号。",[191,193,195,197],{"key":20,"text":192,"correct":22},"挡烟垂壁",{"key":24,"text":194,"correct":22},"防火阀",{"key":28,"text":196,"correct":26},"电动送风口",{"key":31,"text":198,"correct":22},"叶送风口",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":31,"analysis":33},973960,"火灾报警控制器（联动型）接通电源后，无火灾报警、故障报警、屏蔽、监管报警、消音、启动等信息发生时所处的状态是（ ）。",[203,204,205,207],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":22},{"key":28,"text":206,"correct":22},"联动状态",{"key":31,"text":47,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":28,"analysis":33},973961,"火灾报警控制器（联动型）如果接入了火警、故障报警、监管报警，有被屏蔽的设备等发生时所处的状态不是（ ）。",[212,214,216,217],{"key":20,"text":213,"correct":22},"报警状态",{"key":24,"text":215,"correct":22},"故障报警状态",{"key":28,"text":47,"correct":26},{"key":31,"text":218,"correct":22},"监管报警状态",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":31,"analysis":33},973962,"在火灾报警系统中用于为疏散人员和救援人员在现场提供火灾报警信息的设备是（ ）。",[223,225,227,229],{"key":20,"text":224,"correct":22},"火灾探测器",{"key":24,"text":226,"correct":22},"手动报警按钮",{"key":28,"text":228,"correct":22},"声光警报器",{"key":31,"text":230,"correct":26},"火灾显示盘",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":20,"analysis":33},973963,"火灾报警控制器（联动型）的故障指示灯亮，表示检测到可能出现的外部设备故障或控制器本身故障，以下（ ）不属于控制器本身故障。",[235,237,239,241],{"key":20,"text":236,"correct":26},"模块故障",{"key":24,"text":238,"correct":22},"备电欠压",{"key":28,"text":240,"correct":22},"交流电断路",{"key":31,"text":242,"correct":22},"直接手动控制盘故障",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":28,"analysis":33},973964,"消防联动控制器在接收到火灾报警信号后，应在（ ）s内发出启动信号。",[247,249,251,253],{"key":20,"text":248,"correct":22},"1",{"key":24,"text":250,"correct":22},"2",{"key":28,"text":252,"correct":26},"3",{"key":31,"text":254,"correct":22},"4",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":20,"analysis":33},973965,"当火灾报警控制器（联动型）发出启动命令时，启动灯点亮，当控制器检测到受控设备的（ ）时，反馈灯点亮。",[259,261,263,265],{"key":20,"text":260,"correct":26},"反馈信号",{"key":24,"text":262,"correct":22},"启动信号",{"key":28,"text":264,"correct":22},"具体信息",{"key":31,"text":266,"correct":22},"联动信号",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":24,"analysis":33},973966,"当火灾报警控制器主电故障时，下列叙述不正确的是（ ）。",[271,273,275,277],{"key":20,"text":272,"correct":22},"故障灯点亮",{"key":24,"text":274,"correct":26},"主电工作灯点亮",{"key":28,"text":276,"correct":22},"屏幕上显示主电故障",{"key":31,"text":278,"correct":22},"控制器发出故障声",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":31,"analysis":33},973967,"根据系统的用途和配置情况，自动喷水灭火系统又可分为湿式系统、干式系统、预作用系统、重复启闭预作用系统、雨淋系统、（ ）等。",[283,285,287,289],{"key":20,"text":284,"correct":22},"闭式系统",{"key":24,"text":286,"correct":22},"组合分配系统",{"key":28,"text":288,"correct":22},"开式系统",{"key":31,"text":290,"correct":26},"水幕系统",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":24,"analysis":33},973968,"下面不属于消防泵组及控制柜准工作状态要求的是（ ）。",[295,297,299,301],{"key":20,"text":296,"correct":22},"电气控制柜平时应处于自动工作状态，供电正常，仪表、指示众、并关按出正常",{"key":24,"text":298,"correct":26},"消防水泵应处于自动工作状态",{"key":28,"text":300,"correct":22},"有关系统名称和编号的标识牢固、清晰、正确",{"key":31,"text":302,"correct":22},"消防水泵启停功能正常，供水能力测试正常",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":20,"analysis":33},973969,"湿式自动喷水灭火系统主要由（ ）、报警阀组、水流报警装置（水流指示器或压力开关）等组件，以及管道和供水设施等组成。",[307,309,311,313],{"key":20,"text":308,"correct":26},"闭式喷头",{"key":24,"text":310,"correct":22},"开式喷头",{"key":28,"text":312,"correct":22},"充气装置",{"key":31,"text":314,"correct":22},"气压维持装置",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":28,"analysis":33},973970,"下面不属于检查判断自动喷水灭火系统的工作状态的方法是（ ）。",[319,321,323,325],{"key":20,"text":320,"correct":22},"组件外观检查",{"key":24,"text":322,"correct":22},"功能测试",{"key":28,"text":324,"correct":26},"观察法",{"key":31,"text":326,"correct":22},"分析判断",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":20,"analysis":33},973971,"下列建筑的防烟楼梯间、独立前室、共用前室、合用前室及消防电梯前室应采用机械加压送风系统的是（ ）。",[331,333,335,337],{"key":20,"text":332,"correct":26},"建筑高度60m的公共建筑",{"key":24,"text":334,"correct":22},"建筑高度50m的工业建筑",{"key":28,"text":336,"correct":22},"建筑高度60m的住宅建筑",{"key":31,"text":338,"correct":22},"建筑高度100m的住宅建筑",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":31,"analysis":33},973972,"下列不属于机械加压送风系统的组成部件的是（ ）。",[343,345,347,349],{"key":20,"text":344,"correct":22},"送风机",{"key":24,"text":346,"correct":22},"风道",{"key":28,"text":348,"correct":22},"送风口",{"key":31,"text":192,"correct":26},{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":24,"analysis":33},973973,"电气火灾监控设备应能接收来自电气火灾监控探测器的监控报警信号，并在（ ）内发出声光报警信号，指示报警部位，显示报警时间。",[354,356,358,360],{"key":20,"text":355,"correct":22},"20s",{"key":24,"text":357,"correct":26},"10s",{"key":28,"text":359,"correct":22},"30s",{"key":31,"text":361,"correct":22},"100s",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":20,"analysis":33},973974,"电气火灾监控设备应能（ ）接收来自电气火灾监控探测器测量的剩余电流值和温度值，剩余电流值和温度值应可查询。",[366,368,369,370],{"key":20,"text":367,"correct":26},"实时",{"key":24,"text":357,"correct":22},{"key":28,"text":359,"correct":22},{"key":31,"text":361,"correct":22},{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":31,"analysis":33},973975,"当电气火灾监控设备与电气火灾监控探测器之间的连接线断路短路时，电气火灾监控设备，应能在（ ）内发出与监控报警信号有明显区别的声、光故障信号，显示故障部位。",[375,376,377,378],{"key":20,"text":357,"correct":22},{"key":24,"text":355,"correct":22},{"key":28,"text":359,"correct":22},{"key":31,"text":361,"correct":26},{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":28,"analysis":33},973976,"当被保护线路剩余电流达到报警设定值（可自行设定，要求设定范围在20-1000m A）时，剩余电流式电气火灾监控探测器应能在（ ）内发出报警信号，点亮报警指示灯，向电气火灾监控设备发送报警信号。",[383,384,385,386],{"key":20,"text":367,"correct":22},{"key":24,"text":357,"correct":22},{"key":28,"text":359,"correct":26},{"key":31,"text":361,"correct":22},{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":28,"analysis":33},973977,"当被监视部位温度达到报警设定值（可自行设定，要求设定范围在45-140℃）时，测温式电气火灾监控探测器应能在（ ）内发出报警信号，点亮报警指示灯，向电气火灾监控设备发送报警信号。",[391,392,393,395],{"key":20,"text":357,"correct":22},{"key":24,"text":359,"correct":22},{"key":28,"text":394,"correct":26},"40s",{"key":31,"text":361,"correct":22},{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":20,"analysis":33},973978,"当被探测线路在（ ）s内发生14个及以上半周期的故障电弧时故障电弧探测器应能在30s内发出报警信号，点亮报警指示灯，向电气火灾监控设备发送报警信号。",[400,401,402,404],{"key":20,"text":248,"correct":26},{"key":24,"text":252,"correct":22},{"key":28,"text":403,"correct":22},"10",{"key":31,"text":405,"correct":22},"30",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":31,"analysis":33},973979,"下列不属于可燃气体探测报警系统的组成部分的是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"可燃气体报警控制器",{"key":24,"text":413,"correct":22},"可燃气体探测器",{"key":28,"text":415,"correct":22},"图形显示装置",{"key":31,"text":417,"correct":26},"故障电强探测器",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":20,"analysis":33},973980,"下列属于可燃气体探测报警系统的核心控制单元的是（ ）。",[422,423,424,425],{"key":20,"text":411,"correct":26},{"key":24,"text":413,"correct":22},{"key":28,"text":415,"correct":22},{"key":31,"text":426,"correct":22},"火灾声光警报器",{"id":428,"libraryId":5,"type":429,"typeLabel":430,"stem":431,"options":432,"answer":444,"analysis":33},973981,2,"多选题","火灾报警控制器开机后，控制器上操作信息的显示中，说法正确的是（ ）。",[433,435,437,439,441],{"key":20,"text":434,"correct":26},"系统上电进行初始化提示信息",{"key":24,"text":436,"correct":26},"外接设备注册信息",{"key":28,"text":438,"correct":26},"注册结果信息显示",{"key":31,"text":440,"correct":22},"开机完成后进入调试状态",{"key":442,"text":443,"correct":26},"E","声光检查信息","ABCE",{"id":446,"libraryId":5,"type":429,"typeLabel":430,"stem":447,"options":448,"answer":459,"analysis":33},973982,"火灾报警控制器在自动联动状态下，对信息特征描述正确的是（ ）。",[449,451,453,455,457],{"key":20,"text":450,"correct":26},"启动灯亮",{"key":24,"text":452,"correct":22},"液晶显示启动设备参数",{"key":28,"text":454,"correct":26},"液晶显示启动设备部位",{"key":31,"text":456,"correct":26},"记录启动时间",{"key":442,"text":458,"correct":26},"记录启动设备总数","ACDE",{"id":461,"libraryId":5,"type":429,"typeLabel":430,"stem":462,"options":463,"answer":474,"analysis":33},973983,"在消防控制室图形显示装置（CRT）中，对于故障状态信息显示描述正确的是：（ ）。",[464,466,468,470,472],{"key":20,"text":465,"correct":22},"“故障”指示显示黄色，故障排除后，故障信息的光指示信号需要手动清除",{"key":24,"text":467,"correct":26},"声响音调：发出与火警信息明显不同的故障声",{"key":28,"text":469,"correct":26},"对应故障设备以黄色闪烁，故障设备所在区域也显示为黄色",{"key":31,"text":471,"correct":26},"弹出的文字信息显示故障总数和故障报警序号、报警时间、类型编码",{"key":442,"text":473,"correct":26},"当多于个故障时，所有故障设备以黄色闪烁，同时文字信息应按报警时间顺序显示所有故障信息","BCDE",{"id":476,"libraryId":5,"type":429,"typeLabel":430,"stem":477,"options":478,"answer":486,"analysis":33},973984,"下列属于机械加压送风系统的主要组成部件的有（ ）。",[479,480,481,482,484],{"key":20,"text":344,"correct":26},{"key":24,"text":346,"correct":26},{"key":28,"text":348,"correct":26},{"key":31,"text":483,"correct":26},"电气控制柜",{"key":442,"text":485,"correct":22},"排烟阀","ABCD",{"id":488,"libraryId":5,"type":429,"typeLabel":430,"stem":489,"options":490,"answer":500,"analysis":33},973985,"下列属于机械排烟系统的组成部件的有（ ）。",[491,493,495,496,498],{"key":20,"text":492,"correct":26},"排烟风机",{"key":24,"text":494,"correct":26},"排烟出口",{"key":28,"text":485,"correct":26},{"key":31,"text":497,"correct":22},"管道",{"key":442,"text":499,"correct":22},"档烟垂壁","ABC",{"id":502,"libraryId":5,"type":429,"typeLabel":430,"stem":503,"options":504,"answer":474,"analysis":33},973986,"建筑高度大于50m的公共建筑、工业建筑和建筑高度大于100m的住宅建筑，其（ ）等部位应采用机械加压送风系统。",[505,507,509,511,513],{"key":20,"text":506,"correct":22},"楼梯间",{"key":24,"text":508,"correct":26},"独立前室",{"key":28,"text":510,"correct":26},"合用前室",{"key":31,"text":512,"correct":26},"消防电梯前室",{"key":442,"text":514,"correct":26},"共用前室",{"id":516,"libraryId":5,"type":429,"typeLabel":430,"stem":517,"options":518,"answer":529,"analysis":33},973987,"下列建筑应采用机械加压送风系统的有（ ）。",[519,521,523,525,527],{"key":20,"text":520,"correct":22},"某建筑高度为50m办公楼的防烟楼梯间",{"key":24,"text":522,"correct":26},"某建筑高度为72m综合楼的防烟楼梯间共用前室",{"key":28,"text":524,"correct":22},"某建筑高度为100m住宅的共用前室",{"key":31,"text":526,"correct":22},"某建筑高度为50m厂房的消防电梯前室",{"key":442,"text":528,"correct":26},"某建筑高度为60m厂房的消防电梯前室","BE",{"id":531,"libraryId":5,"type":429,"typeLabel":430,"stem":532,"options":533,"answer":544,"analysis":33},973988,"下列建筑的房间、走道及中庭可采用自然排烟系统的有（ ）。",[534,536,538,540,542],{"key":20,"text":535,"correct":26},"建筑高度为100m的住宅建筑",{"key":24,"text":537,"correct":26},"建筑高度为45m的办公建筑",{"key":28,"text":539,"correct":22},"建筑高度为72m的综合建筑",{"key":31,"text":541,"correct":22},"建筑高度为60m工业建筑",{"key":442,"text":543,"correct":26},"建筑高度为40m工业建筑","ABE",{"id":546,"libraryId":5,"type":429,"typeLabel":430,"stem":547,"options":548,"answer":558,"analysis":33},973989,"下列建筑的房间、走道及中庭可应采用机械排烟系统的有（ ）。",[549,551,553,555,556],{"key":20,"text":550,"correct":22},"建筑高度50m的办公建筑",{"key":24,"text":552,"correct":26},"建筑高度60m的丙类厂房",{"key":28,"text":554,"correct":26},"建筑高度120m的住宅建筑",{"key":31,"text":336,"correct":22},{"key":442,"text":557,"correct":26},"建筑高度60m的综合建筑","BCE",{"id":560,"libraryId":5,"type":429,"typeLabel":430,"stem":561,"options":562,"answer":459,"analysis":33},973990,"下列属于风机及控制柜正常工作状态下，应达到的要求有（ ）。",[563,565,567,569,571],{"key":20,"text":564,"correct":26},"风机及控制柜外观完好，组件齐全，有关系统名称和编号的标识牢固、清晰、正确",{"key":24,"text":566,"correct":22},"风机安装气流方向正确，启动功能正常，风机运转无异常振动或声响",{"key":28,"text":568,"correct":26},"风机控制柜仪表指示灯显示正常，手\u002F自动转换装置外观完好",{"key":31,"text":570,"correct":26},"主、备电源切换功能正常，供电状态指示正确",{"key":442,"text":572,"correct":26},"风机驱动装置的外露部位防护完好",{"id":574,"libraryId":5,"type":429,"typeLabel":430,"stem":575,"options":576,"answer":486,"analysis":33},973991,"下列属于送风（排烟）管道正常工作状态下，应达到的要求有（ ）。",[577,579,581,583,585],{"key":20,"text":578,"correct":26},"风管表面平整，无变形损坏",{"key":24,"text":580,"correct":26},"风管与风机、风管与风管之间的连接牢固、严密，无损坏脱落",{"key":28,"text":582,"correct":26},"风管穿越隔墙处的缝隙防火封堵完好",{"key":31,"text":584,"correct":26},"排烟支管上以及排烟管道在穿越防火分区、排烟机房的隔墙排烟防火阀安装到位",{"key":442,"text":586,"correct":22},"排烟管道隔热材料应为不燃材料，且与可燃物保持不小于50mm的距离",{"id":588,"libraryId":5,"type":429,"typeLabel":430,"stem":589,"options":590,"answer":500,"analysis":33},973992,"下列关于检查判断防烟排烟系统风机及电气控制柜的工作状态说法正确的有（ ）。",[591,593,595,597,599],{"key":20,"text":592,"correct":26},"检查送风系统进风口和排烟系统排烟出口处工作环境",{"key":24,"text":594,"correct":26},"检查防烟（排烟）风机组件的齐全性和外观完整性、系统和组件标识",{"key":28,"text":596,"correct":26},"检查电气控制柜的供电状态，测试和主\u002F备电切换、手\u002F自动切换功能",{"key":31,"text":598,"correct":22},"手\u002F自动转换开关平时应处于手动位",{"key":442,"text":600,"correct":22},"测试风机自动启停功能",{"id":602,"libraryId":5,"type":429,"typeLabel":430,"stem":603,"options":604,"answer":615,"analysis":33},973993,"下列属于消防设备未端配电装置组成器件的有（ ）。",[605,607,609,611,613],{"key":20,"text":606,"correct":26},"按钮",{"key":24,"text":608,"correct":26},"电源线路",{"key":28,"text":610,"correct":22},"电源开关",{"key":31,"text":612,"correct":26},"断路器",{"key":442,"text":614,"correct":26},"配电箱","ABDE",[617,620,623,626,629,632],{"id":15,"name":618,"category":7,"favorite":619},"领导干部任职前廉政法规知识测试题",92,{"id":621,"name":622,"category":7,"favorite":15},595,"建筑结构与设备",{"id":624,"name":625,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":627,"name":628,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":630,"name":631,"category":7,"favorite":8},534,"BIM工程师",{"id":633,"name":631,"category":7,"favorite":8},535]