[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-17":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":504},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,17,50,2486,[13,35,45,51,57,63,69,75,81,87,93,99,105,111,117,123,129,135,141,147,161,173,185,197,209,221,233,245,257,269,281,293,305,314,322,330,340,352,364,376,388,400,412,422,434,444,456,468,480,492],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},973741,2,"多选题","消防控制室图形显示装置，显示屏上一般都有各楼层平面示意图，上面标明了各消防设施的（）等信息。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","名称",true,{"key":24,"text":25,"correct":22},"B","类型",{"key":27,"text":28,"correct":22},"C","所在位置",{"key":30,"text":31,"correct":32},"D","工作状态",false,"ABC","",{"id":36,"libraryId":5,"type":37,"typeLabel":38,"stem":39,"options":40,"answer":44,"analysis":34},973742,3,"判断题","区域控制器和集中控制器之间不能相互收、发相关信息和\u002F或指令。（）",[41,43],{"key":20,"text":42,"correct":32},"正确",{"key":24,"text":44,"correct":22},"错误",{"id":46,"libraryId":5,"type":37,"typeLabel":38,"stem":47,"options":48,"answer":42,"analysis":34},973743,"消防联动控制器是消防联动控制系统的核心组件。（）",[49,50],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":52,"libraryId":5,"type":37,"typeLabel":38,"stem":53,"options":54,"answer":44,"analysis":34},973744,"火灾自动报警系统控制器的电源工作状态分为主电工作状态和备电故障状态。（）",[55,56],{"key":20,"text":42,"correct":32},{"key":24,"text":44,"correct":22},{"id":58,"libraryId":5,"type":37,"typeLabel":38,"stem":59,"options":60,"answer":44,"analysis":34},973745,"当备用电源出现故障时，备用电源工作指示灯熄灭，控制器备用电源指示灯、系统故障指示灯点亮。（）",[61,62],{"key":20,"text":42,"correct":32},{"key":24,"text":44,"correct":22},{"id":64,"libraryId":5,"type":37,"typeLabel":38,"stem":65,"options":66,"answer":42,"analysis":34},973746,"火灾自动报警系统控制器不可长时间处于备电工作状态，否则将导致蓄电池亏电损坏。（）",[67,68],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":70,"libraryId":5,"type":37,"typeLabel":38,"stem":71,"options":72,"answer":44,"analysis":34},973747,"湿式系统适用于环境温度低于4℃或高于70℃的场所。（）",[73,74],{"key":20,"text":42,"correct":32},{"key":24,"text":44,"correct":22},{"id":76,"libraryId":5,"type":37,"typeLabel":38,"stem":77,"options":78,"answer":42,"analysis":34},973748,"湿式自动喷水灭火系统中准工作状态时配水管道内充满用于启动系统的有压水。（）",[79,80],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":82,"libraryId":5,"type":37,"typeLabel":38,"stem":83,"options":84,"answer":42,"analysis":34},973749,"水流指示器是将水流信号转换为电信号的一种报警装置。（）",[85,86],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":88,"libraryId":5,"type":37,"typeLabel":38,"stem":89,"options":90,"answer":42,"analysis":34},973750,"自动喷水灭火系统工作状态的检查判断，可以沿水流方向依序进行。（）",[91,92],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":94,"libraryId":5,"type":37,"typeLabel":38,"stem":95,"options":96,"answer":42,"analysis":34},973751,"防烟系统可分为自然通风系统和机械加压送风系统。（）",[97,98],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":100,"libraryId":5,"type":37,"typeLabel":38,"stem":101,"options":102,"answer":44,"analysis":34},973752,"排烟管道隔热材料宜为不燃材料。（）",[103,104],{"key":20,"text":42,"correct":32},{"key":24,"text":44,"correct":22},{"id":106,"libraryId":5,"type":37,"typeLabel":38,"stem":107,"options":108,"answer":42,"analysis":34},973753,"涉电作业应注意安全，风机出现异常震动或声响、电动机反转时，应立即停止相关设备。（）",[109,110],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":112,"libraryId":5,"type":37,"typeLabel":38,"stem":113,"options":114,"answer":42,"analysis":34},973754,"消防设备电源末端切换就是消防设备的两个电源相互切换，互为备用电源的一种供电形式。（）",[115,116],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":118,"libraryId":5,"type":37,"typeLabel":38,"stem":119,"options":120,"answer":42,"analysis":34},973755,"当屏蔽后，集中火灾报警控制器可以指示屏蔽部位。（）",[121,122],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":124,"libraryId":5,"type":37,"typeLabel":38,"stem":125,"options":126,"answer":42,"analysis":34},973756,"在集中火灾报警控制器控制面板显示屏右侧的信息显示列表上查看火警信息，可以同时看到报警编号和位置名称。（）",[127,128],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":130,"libraryId":5,"type":37,"typeLabel":38,"stem":131,"options":132,"answer":44,"analysis":34},973757,"通过集中火灾报警控制器和消防控制室图像显示装置查看报警信息确定报警部位，操作完毕，应将集中火灾报警控制器和消防控制室图像显示装置恢复到正常工作状态。（）",[133,134],{"key":20,"text":42,"correct":32},{"key":24,"text":44,"correct":22},{"id":136,"libraryId":5,"type":37,"typeLabel":38,"stem":137,"options":138,"answer":42,"analysis":34},973758,"收到气体喷洒反馈信号时，指示灯亮。（）",[139,140],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":142,"libraryId":5,"type":37,"typeLabel":38,"stem":143,"options":144,"answer":42,"analysis":34},973759,"消防设备末端配电装置操作人员必须具备电工作业证。（）",[145,146],{"key":20,"text":42,"correct":22},{"key":24,"text":44,"correct":32},{"id":148,"libraryId":5,"type":149,"typeLabel":150,"stem":151,"options":152,"answer":30,"analysis":34},973760,1,"单选题","（ ）就是要以高度的职业道德精神，在本职岗位上尽职尽责，甚至做好为消防事业献出生命的准备。",[153,155,157,159],{"key":20,"text":154,"correct":32},"遵纪守法",{"key":24,"text":156,"correct":32},"英勇顽强",{"key":27,"text":158,"correct":32},"爱岗敬业",{"key":30,"text":160,"correct":22},"忠于职守",{"id":162,"libraryId":5,"type":149,"typeLabel":150,"stem":163,"options":164,"answer":30,"analysis":34},973761,"职业道德是企业文化的重要组成部分，先进的企业文化是把企业职工的思想和（ ）放在首位的。",[165,167,169,171],{"key":20,"text":166,"correct":32},"法律知识的普及",{"key":24,"text":168,"correct":32},"安全教育",{"key":27,"text":170,"correct":32},"技能培训",{"key":30,"text":172,"correct":22},"职业道德教育",{"id":174,"libraryId":5,"type":149,"typeLabel":150,"stem":175,"options":176,"answer":24,"analysis":34},973762,"人员密集场所发生火灾，该场所的现场工作人员不履行组织、引导在场人员疏散的义务，情节严重，尚不构成犯罪的，处（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":32},"十日以上十五日以下拘留",{"key":24,"text":180,"correct":22},"五日以上十日以下拘留",{"key":27,"text":182,"correct":32},"五日以下拘留",{"key":30,"text":184,"correct":32},"十五日以上拘留",{"id":186,"libraryId":5,"type":149,"typeLabel":150,"stem":187,"options":188,"answer":27,"analysis":34},973763,"我国有关劳动问题的基本法是（ ），它是我国调整劳动关系的准则。",[189,191,193,195],{"key":20,"text":190,"correct":32},"《中华人民共和国工会法》",{"key":24,"text":192,"correct":32},"《中华人民共和国宪法》",{"key":27,"text":194,"correct":22},"《中华人民共和国劳动法》",{"key":30,"text":196,"correct":32},"《中华人民共和国劳动合同法》",{"id":198,"libraryId":5,"type":149,"typeLabel":150,"stem":199,"options":200,"answer":30,"analysis":34},973764,"消防工作具有社会性、（ ）、行政性和技术性等特点。",[201,203,205,207],{"key":20,"text":202,"correct":32},"偶然性",{"key":24,"text":204,"correct":32},"突发性",{"key":27,"text":206,"correct":32},"必然性",{"key":30,"text":208,"correct":22},"经常性",{"id":210,"libraryId":5,"type":149,"typeLabel":150,"stem":211,"options":212,"answer":30,"analysis":34},973765,"属于梯类建筑火灾逃生避难器材的是（ ）。",[213,215,217,219],{"key":20,"text":214,"correct":32},"逃生缓降器",{"key":24,"text":216,"correct":32},"应急逃生器",{"key":27,"text":218,"correct":32},"逃生绳",{"key":30,"text":220,"correct":22},"悬挂式逃生梯",{"id":222,"libraryId":5,"type":149,"typeLabel":150,"stem":223,"options":224,"answer":30,"analysis":34},973766,"机械加压送风防烟系统主要由（ ）、送风管道、送风机和防烟部位（楼梯间、前室或合用前室）以及风机控制柜等组成。",[225,227,229,231],{"key":20,"text":226,"correct":32},"排烟口",{"key":24,"text":228,"correct":32},"挡烟垂壁",{"key":27,"text":230,"correct":32},"防排烟控制器",{"key":30,"text":232,"correct":22},"送风口",{"id":234,"libraryId":5,"type":149,"typeLabel":150,"stem":235,"options":236,"answer":27,"analysis":34},973767,"排烟防火阀安装在机械排烟系统的管道上，平时呈开启状态，火灾时当排烟管道内烟气温度达到（ ）时关闭，并在一定时间内满足漏烟量和耐火完整性要求，起隔烟阻火作用的阀门。",[237,239,241,243],{"key":20,"text":238,"correct":32},"150℃",{"key":24,"text":240,"correct":32},"200℃",{"key":27,"text":242,"correct":22},"280℃",{"key":30,"text":244,"correct":32},"380℃",{"id":246,"libraryId":5,"type":149,"typeLabel":150,"stem":247,"options":248,"answer":30,"analysis":34},973768,"常闭防火门平常在（ ）的作用下处于关闭的状态，因此火灾时能起到阻止火势及烟气蔓延。",[249,251,253,255],{"key":20,"text":250,"correct":32},"报警器",{"key":24,"text":252,"correct":32},"顺序器",{"key":27,"text":254,"correct":32},"防火门释放器",{"key":30,"text":256,"correct":22},"闭门器",{"id":258,"libraryId":5,"type":149,"typeLabel":150,"stem":259,"options":260,"answer":24,"analysis":34},973769,"防火门应为向疏散方向开启的（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":32},"弹簧门",{"key":24,"text":264,"correct":22},"平开门",{"key":27,"text":266,"correct":32},"推拉门",{"key":30,"text":268,"correct":32},"转门",{"id":270,"libraryId":5,"type":149,"typeLabel":150,"stem":271,"options":272,"answer":24,"analysis":34},973770,"闭式洒水喷头的公称动作温度为68℃时对应颜色标志是（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":32},"绿",{"key":24,"text":276,"correct":22},"红",{"key":27,"text":278,"correct":32},"黄",{"key":30,"text":280,"correct":32},"橙",{"id":282,"libraryId":5,"type":149,"typeLabel":150,"stem":283,"options":284,"answer":27,"analysis":34},973771,"下面哪种系统中没有用到末端试水装置（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":32},"湿式自动喷水灭火系统",{"key":24,"text":288,"correct":32},"干式自动喷水灭火系统",{"key":27,"text":290,"correct":22},"雨淋自动喷水灭火系统",{"key":30,"text":292,"correct":32},"预作用自动喷水灭火系统",{"id":294,"libraryId":5,"type":149,"typeLabel":150,"stem":295,"options":296,"answer":24,"analysis":34},973772,"火灾的水平蔓延速度快、闭式喷头的开放不能及时使喷水有效覆盖着火区域的场所应采用的自动喷水灭火系统是（ ）。",[297,299,301,303],{"key":20,"text":298,"correct":32},"干式系统",{"key":24,"text":300,"correct":22},"雨淋系统",{"key":27,"text":302,"correct":32},"水幕系统",{"key":30,"text":304,"correct":32},"湿式系统",{"id":306,"libraryId":5,"type":149,"typeLabel":150,"stem":307,"options":308,"answer":30,"analysis":34},973773,"由火灾自动报警系统或传动管控制，自动开启雨淋阀和启动消防水泵后，向开式洒水喷头供水的自动喷水灭火系统是（ ）。",[309,310,311,313],{"key":20,"text":298,"correct":32},{"key":24,"text":304,"correct":32},{"key":27,"text":312,"correct":32},"预作用系统",{"key":30,"text":300,"correct":22},{"id":315,"libraryId":5,"type":149,"typeLabel":150,"stem":316,"options":317,"answer":20,"analysis":34},973774,"准工作状态时配水管道内充满用于启动系统的有压气体的自动喷水灭火系统是（ ）。",[318,319,320,321],{"key":20,"text":298,"correct":22},{"key":24,"text":304,"correct":32},{"key":27,"text":312,"correct":32},{"key":30,"text":300,"correct":32},{"id":323,"libraryId":5,"type":149,"typeLabel":150,"stem":324,"options":325,"answer":27,"analysis":34},973775,"以下哪项不属于自动喷水灭火系统的闭式系统（ ）。",[326,327,328,329],{"key":20,"text":312,"correct":32},{"key":24,"text":304,"correct":32},{"key":27,"text":302,"correct":22},{"key":30,"text":298,"correct":32},{"id":331,"libraryId":5,"type":149,"typeLabel":150,"stem":332,"options":333,"answer":30,"analysis":34},973776,"采用开式洒水喷头的自动喷水灭火系统称为（ ）。",[334,336,337,338],{"key":20,"text":335,"correct":32},"闭式系统",{"key":24,"text":300,"correct":32},{"key":27,"text":302,"correct":32},{"key":30,"text":339,"correct":22},"开式系统",{"id":341,"libraryId":5,"type":149,"typeLabel":150,"stem":342,"options":343,"answer":24,"analysis":34},973777,"自动喷水灭火系统，按安装的（ ）开闭形式不同分为闭式和开式系统两大类型",[344,346,348,350],{"key":20,"text":345,"correct":32},"报警阀组",{"key":24,"text":347,"correct":22},"洒水喷头",{"key":27,"text":349,"correct":32},"水流指示器",{"key":30,"text":351,"correct":32},"消防水箱",{"id":353,"libraryId":5,"type":149,"typeLabel":150,"stem":354,"options":355,"answer":27,"analysis":34},973778,"室内消火栓按其出水口形式可分为（ ）。",[356,358,360,362],{"key":20,"text":357,"correct":32},"地上式和地下式",{"key":24,"text":359,"correct":32},"承插式和法兰式",{"key":27,"text":361,"correct":22},"单出口式和双出口式",{"key":30,"text":363,"correct":32},"普通式与特殊式",{"id":365,"libraryId":5,"type":149,"typeLabel":150,"stem":366,"options":367,"answer":27,"analysis":34},973779,"对手动火灾报警按钮的外观清洁维护时，做法正确的是（ ）。",[368,370,372,374],{"key":20,"text":369,"correct":32},"用力擦触玻璃",{"key":24,"text":371,"correct":32},"用水冲洗",{"key":27,"text":373,"correct":22},"用吹风机吹扫手动火灾报警按钮表面",{"key":30,"text":375,"correct":32},"将玻璃卸下进行清洗",{"id":377,"libraryId":5,"type":149,"typeLabel":150,"stem":378,"options":379,"answer":27,"analysis":34},973780,"手提式泡沫灭火器主要用于扑救（ ）初期火灾，也可扑救固体初期火灾。",[380,382,384,386],{"key":20,"text":381,"correct":32},"气体",{"key":24,"text":383,"correct":32},"带电设备",{"key":27,"text":385,"correct":22},"液体",{"key":30,"text":387,"correct":32},"金属",{"id":389,"libraryId":5,"type":149,"typeLabel":150,"stem":390,"options":391,"answer":20,"analysis":34},973781,"BC类干粉灭火器又称为（ ）干粉灭火器。",[392,394,396,398],{"key":20,"text":393,"correct":22},"碳酸氢钠",{"key":24,"text":395,"correct":32},"磷酸铵盐",{"key":27,"text":397,"correct":32},"钾盐",{"key":30,"text":399,"correct":32},"氨基",{"id":401,"libraryId":5,"type":149,"typeLabel":150,"stem":402,"options":403,"answer":27,"analysis":34},973782,"具有喷筒构造的灭火器是（ ）。",[404,406,408,410],{"key":20,"text":405,"correct":32},"清水灭火器",{"key":24,"text":407,"correct":32},"泡沫灭火器",{"key":27,"text":409,"correct":22},"CO2灭火器",{"key":30,"text":411,"correct":32},"干粉灭火器",{"id":413,"libraryId":5,"type":149,"typeLabel":150,"stem":414,"options":415,"answer":20,"analysis":34},973783,"下列不属于水基型灭火器的是（ ）。",[416,417,418,420],{"key":20,"text":409,"correct":22},{"key":24,"text":405,"correct":32},{"key":27,"text":419,"correct":32},"空气泡沫灭火器",{"key":30,"text":421,"correct":32},"水成膜泡沫灭火器",{"id":423,"libraryId":5,"type":149,"typeLabel":150,"stem":424,"options":425,"answer":24,"analysis":34},973784,"防烟楼梯间和通向前室的门应当为（ ）。",[426,428,430,432],{"key":20,"text":427,"correct":32},"甲级防火门",{"key":24,"text":429,"correct":22},"乙级防火门",{"key":27,"text":431,"correct":32},"丙级防火门",{"key":30,"text":433,"correct":32},"普通门",{"id":435,"libraryId":5,"type":149,"typeLabel":150,"stem":436,"options":437,"answer":27,"analysis":34},973785,"常开防火门平时在防火门（ ）作用下处于开启状态。",[438,439,440,442],{"key":20,"text":256,"correct":32},{"key":24,"text":252,"correct":32},{"key":27,"text":441,"correct":22},"释放器",{"key":30,"text":443,"correct":32},"防火锁具",{"id":445,"libraryId":5,"type":149,"typeLabel":150,"stem":446,"options":447,"answer":30,"analysis":34},973786,"通常防火墙的类型不包含的是（ ）。",[448,450,452,454],{"key":20,"text":449,"correct":32},"内防火墙",{"key":24,"text":451,"correct":32},"外防火墙",{"key":27,"text":453,"correct":32},"室外独立墙",{"key":30,"text":455,"correct":22},"轻质隔墙",{"id":457,"libraryId":5,"type":149,"typeLabel":150,"stem":458,"options":459,"answer":24,"analysis":34},973787,"疏散走道的指示标志宜设在疏散走道及其转角处距地面（ ）米以下的墙面上。",[460,462,464,466],{"key":20,"text":461,"correct":32},"1.5",{"key":24,"text":463,"correct":22},"1",{"key":27,"text":465,"correct":32},"2",{"key":30,"text":467,"correct":32},"0.5",{"id":469,"libraryId":5,"type":149,"typeLabel":150,"stem":470,"options":471,"answer":20,"analysis":34},973788,"（ ）是指建筑物内由墙体等围护构件构成的无封闭防烟功能，且与其他使用空间相通的楼梯间。",[472,474,476,478],{"key":20,"text":473,"correct":22},"敞开楼梯间",{"key":24,"text":475,"correct":32},"封闭楼梯间",{"key":27,"text":477,"correct":32},"防烟楼梯间",{"key":30,"text":479,"correct":32},"室外辅助疏散楼梯",{"id":481,"libraryId":5,"type":149,"typeLabel":150,"stem":482,"options":483,"answer":30,"analysis":34},973789,"建筑物的安全疏散设施不包括（ ）。",[484,486,488,490],{"key":20,"text":485,"correct":32},"疏散楼梯和楼梯间",{"key":24,"text":487,"correct":32},"疏散走道",{"key":27,"text":489,"correct":32},"安全出口",{"key":30,"text":491,"correct":22},"消火栓",{"id":493,"libraryId":5,"type":149,"typeLabel":150,"stem":494,"options":495,"answer":24,"analysis":34},973790,"在消防控制室的防火巡查中，发现（ ），应当上报有关领导，制定限期改正措施。",[496,498,500,502],{"key":20,"text":497,"correct":32},"值班人员脱岗",{"key":24,"text":499,"correct":22},"电源线破损",{"key":27,"text":501,"correct":32},"擅自关闭火灾自动报警、自动灭火系统",{"key":30,"text":503,"correct":32},"没有认真填写值班记录及系统运行登记表和控制器日检登记表",[505,508,511,514,517,520],{"id":149,"name":506,"category":7,"favorite":507},"领导干部任职前廉政法规知识测试题",92,{"id":509,"name":510,"category":7,"favorite":149},595,"建筑结构与设备",{"id":512,"name":513,"category":7,"favorite":149},715,"招标采购专业知识与法律法规",{"id":515,"name":516,"category":7,"favorite":149},848,"市政方向-通用基础",{"id":518,"name":519,"category":7,"favorite":8},534,"BIM工程师",{"id":521,"name":519,"category":7,"favorite":8},535]