[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-16":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":480},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,16,50,2486,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,158,170,182,194,206,218,230,242,254,266,278,286,294,302,314,326,337,345,355,363,378,391,402,413,422,434,447,460,472],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},973691,3,"判断题","控制器任何一部分发生故障时，公共故障指示灯亮。（）",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},973692,"主电源工作正常时，备用电源不工作，备电故障指示灯熄灭。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},973693,"火灾自动报警系统控制器由AC220V电源供电工作。（）",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":21,"analysis":27},973694,"自动喷水灭火系统是应用范围最广、用量最多且造价低廉的自动灭火系统。",[44,45],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},973695,"重复启闭预作用系统与常规预作用系统不同之处在于扑灭火灾后能自动关闭报警阀停止喷水，发生复燃时又能再次开启报警阀恢复喷水。（）",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":25,"analysis":27},973696,"湿式自动喷水灭火系统中准工作状态时配水管道内充满用于启动系统的有压气体。（）",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":21,"analysis":27},973697,"压力开关是一种压力传感器，其作用是将系统中的水压信号转换为电信号。（）",[62,63],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},973698,"自动喷水灭火系统的工作状态可以简单划分为系统正常工作状态、准工作状态和故障状态。（）",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},973699,"检查消防泵组电气控制柜的供电和各项切换功能，手\u002F自动转换开关应处于自动位。（）",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":25,"analysis":27},973700,"防排烟系统电气控制柜手\u002F自动转换开关平时应处于手动位。（）",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":21,"analysis":27},973701,"进行板式排烟口远控执行器复位操作时应注意力度，防止用力过度造成设备损坏。（）",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},973702,"实施主\u002F备电切换时，风机控制柜双电源转换开关应处于自动控制状态，测试完成后恢复手动控制。（）",[92,93],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":25,"analysis":27},973703,"电气火灾监控设备开机前先闭合备用电源开关再闭合主电源空气开关。（）",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":25,"analysis":27},973704,"可燃气体探测报警系统主机开机正常运行时，指示灯面板的主电工作指示灯应为黄灯常亮。（）",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},973705,"断开可燃气体报警控制器和点型可燃气体探测器之间的连接线，可燃气体报警控制器应有故障事件发生，并有具体发生时间、具体发生位置。（）",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},973706,"采用可燃气体测试可燃气体探测报警系统时注意用气安全。",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},973707,"集中火灾报警控制器不能间接地接收来自火灾探测器及其他火灾报警触发器件的火灾报警信号。（）",[122,123],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},973708,"模拟产生各类报警信息时不应损坏系统组件，每次操作完成后，应将设备恢复到正常工作状态。（）",[128,129],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":25,"analysis":27},973709,"集中火灾报警控制器能直接而不能间接地接收来自除火灾报警、故障信号之外的其他输入信号。（）",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":25,"analysis":27},973710,"消防控制室图形显示装置，显示屏上一定有各楼层平面示意图，上面标明了各消防设施名称、类型、所在位置等信息。（）",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":144,"typeLabel":145,"stem":146,"options":147,"answer":156,"analysis":27},973711,1,"单选题","以下哪项不是消防控制室图形显示装置的主要功能：（）。",[148,150,152,155],{"key":20,"text":149,"correct":26},"图形显示",{"key":24,"text":151,"correct":26},"通信故障报警",{"key":153,"text":154,"correct":26},"C","信息记录",{"key":156,"text":157,"correct":22},"D","自检",{"id":159,"libraryId":5,"type":144,"typeLabel":145,"stem":160,"options":161,"answer":24,"analysis":27},973712,"控制模块收到联动设备反馈时，反馈指示灯亮（）。",[162,164,166,168],{"key":20,"text":163,"correct":26},"黄灯",{"key":24,"text":165,"correct":22},"红灯",{"key":153,"text":167,"correct":26},"绿灯",{"key":156,"text":169,"correct":26},"蓝灯",{"id":171,"libraryId":5,"type":144,"typeLabel":145,"stem":172,"options":173,"answer":20,"analysis":27},973713,"探测器发生火警后，（）指示灯亮。",[174,176,178,180],{"key":20,"text":175,"correct":22},"火警",{"key":24,"text":177,"correct":26},"监管",{"key":153,"text":179,"correct":26},"故障",{"key":156,"text":181,"correct":26},"屏蔽",{"id":183,"libraryId":5,"type":144,"typeLabel":145,"stem":184,"options":185,"answer":24,"analysis":27},973714,"控制器任何一部分发生故障时，（）指示灯亮。",[186,188,190,192],{"key":20,"text":187,"correct":26},"系统故障",{"key":24,"text":189,"correct":22},"公共故障",{"key":153,"text":191,"correct":26},"主电故障",{"key":156,"text":193,"correct":26},"通讯故障",{"id":195,"libraryId":5,"type":144,"typeLabel":145,"stem":196,"options":197,"answer":20,"analysis":27},973715,"消音指示灯是（）。",[198,200,202,204],{"key":20,"text":199,"correct":22},"绿色",{"key":24,"text":201,"correct":26},"红色",{"key":153,"text":203,"correct":26},"黄色",{"key":156,"text":205,"correct":26},"蓝色",{"id":207,"libraryId":5,"type":144,"typeLabel":145,"stem":208,"options":209,"answer":156,"analysis":27},973716,"火灾时，受高温烟气作用喷头动作喷水，且出水压力不低于（）MPa。",[210,212,214,216],{"key":20,"text":211,"correct":26},"0．02",{"key":24,"text":213,"correct":26},"0．03",{"key":153,"text":215,"correct":26},"0．04",{"key":156,"text":217,"correct":22},"0．0．05",{"id":219,"libraryId":5,"type":144,"typeLabel":145,"stem":220,"options":221,"answer":24,"analysis":27},973717,"水力警铃动作并发出声报警信号，该声响在3米远处声强不低于（）dB。",[222,224,226,228],{"key":20,"text":223,"correct":26},"50",{"key":24,"text":225,"correct":22},"70",{"key":153,"text":227,"correct":26},"75",{"key":156,"text":229,"correct":26},"80",{"id":231,"libraryId":5,"type":144,"typeLabel":145,"stem":232,"options":233,"answer":20,"analysis":27},973718,"湿式报警阀主阀前后表差应小于（）。",[234,236,238,240],{"key":20,"text":235,"correct":22},"0．01 MPa",{"key":24,"text":237,"correct":26},"0．02 MPa",{"key":153,"text":239,"correct":26},"0．04 MPa",{"key":156,"text":241,"correct":26},"0．05 MPa",{"id":243,"libraryId":5,"type":144,"typeLabel":145,"stem":244,"options":245,"answer":20,"analysis":27},973719,"挡烟垂壁是用（）材料制成的，垂直安装在建筑顶棚、梁或吊顶下，能在火灾时形成一定蓄烟空间的挡烟分隔设施。",[246,248,250,252],{"key":20,"text":247,"correct":22},"不燃材料",{"key":24,"text":249,"correct":26},"难燃材料",{"key":153,"text":251,"correct":26},"可燃材料",{"key":156,"text":253,"correct":26},"易燃材料",{"id":255,"libraryId":5,"type":144,"typeLabel":145,"stem":256,"options":257,"answer":20,"analysis":27},973720,"电气火灾监控设备应能接收来自电电气火灾监控探测器的监控报警信号，并在（）秒内发出声、光报警信号，指示报警部位、显示报警时间。",[258,260,262,264],{"key":20,"text":259,"correct":22},"10",{"key":24,"text":261,"correct":26},"30",{"key":153,"text":263,"correct":26},"40",{"key":156,"text":265,"correct":26},"100",{"id":267,"libraryId":5,"type":144,"typeLabel":145,"stem":268,"options":269,"answer":156,"analysis":27},973721,"关闭电气火灾监控设备主电源，电气火灾监控设备处于（）状态。",[270,272,274,276],{"key":20,"text":271,"correct":26},"主电工作，备电准工作",{"key":24,"text":273,"correct":26},"主电工作，备电故障",{"key":153,"text":275,"correct":26},"主备电同时工作",{"key":156,"text":277,"correct":22},"主电故障，备电工作",{"id":279,"libraryId":5,"type":144,"typeLabel":145,"stem":280,"options":281,"answer":153,"analysis":27},973722,"可燃气体探测报警系统主机开机正常运行时，指示灯面板的主电工作指示灯应为（）常亮。",[282,283,284,285],{"key":20,"text":163,"correct":26},{"key":24,"text":165,"correct":26},{"key":153,"text":167,"correct":22},{"key":156,"text":169,"correct":26},{"id":287,"libraryId":5,"type":144,"typeLabel":145,"stem":288,"options":289,"answer":156,"analysis":27},973723,"打开可燃气体报警控制器备用电源，关闭可燃气体报警控制器主电源，可燃气体报警控制器处于（）状态。",[290,291,292,293],{"key":20,"text":271,"correct":26},{"key":24,"text":273,"correct":26},{"key":153,"text":275,"correct":26},{"key":156,"text":277,"correct":22},{"id":295,"libraryId":5,"type":144,"typeLabel":145,"stem":296,"options":297,"answer":156,"analysis":27},973724,"当集中火灾报警控制器内部、控制器与其连接的部件间发生故障时，控制器能在（）s内发出与火灾报警信号有明显区别的故障声、光信号，指示系统故障。",[298,299,300,301],{"key":20,"text":259,"correct":26},{"key":24,"text":261,"correct":26},{"key":153,"text":223,"correct":26},{"key":156,"text":265,"correct":22},{"id":303,"libraryId":5,"type":144,"typeLabel":145,"stem":304,"options":305,"answer":156,"analysis":27},973725,"以下哪项不是常用火灾报警触发设备（）。",[306,308,310,312],{"key":20,"text":307,"correct":26},"感烟感温探测器",{"key":24,"text":309,"correct":26},"手动火灾报警按钮",{"key":153,"text":311,"correct":26},"红外火焰探测器",{"key":156,"text":313,"correct":22},"消火栓按钮",{"id":315,"libraryId":5,"type":144,"typeLabel":145,"stem":316,"options":317,"answer":153,"analysis":27},973726,"以下哪项不属于常用火灾联动设备：（）。",[318,320,322,324],{"key":20,"text":319,"correct":26},"风机",{"key":24,"text":321,"correct":26},"水泵",{"key":153,"text":323,"correct":22},"手动报警按钮",{"key":156,"text":325,"correct":26},"卷帘门",{"id":327,"libraryId":5,"type":144,"typeLabel":145,"stem":328,"options":329,"answer":156,"analysis":27},973727,"以下哪项不是常用火灾监管设备（）。",[330,332,334,336],{"key":20,"text":331,"correct":26},"压力开关",{"key":24,"text":333,"correct":26},"水流指示器",{"key":153,"text":335,"correct":26},"信号蝶阀",{"key":156,"text":323,"correct":22},{"id":338,"libraryId":5,"type":144,"typeLabel":145,"stem":339,"options":340,"answer":24,"analysis":27},973728,"断开集中火灾报警控制器和火灾探测器之间连接线，使集中火灾报警控制器处于（）状态。",[341,342,343,344],{"key":20,"text":177,"correct":26},{"key":24,"text":179,"correct":22},{"key":153,"text":175,"correct":26},{"key":156,"text":181,"correct":26},{"id":346,"libraryId":5,"type":144,"typeLabel":145,"stem":347,"options":348,"answer":153,"analysis":27},973729,"点击“（）”图标，显示火警监管信息。",[349,350,351,353],{"key":20,"text":175,"correct":26},{"key":24,"text":177,"correct":26},{"key":153,"text":352,"correct":22},"3火警监管",{"key":156,"text":354,"correct":26},"火警屏蔽",{"id":356,"libraryId":5,"type":144,"typeLabel":145,"stem":357,"options":358,"answer":20,"analysis":27},973730,"当火警发生时，第一个信息标识“火警”就会显示（），同时报警详细信息就会在上方信息栏以文字形式显示出来，在平面图中可以看到报警位置和编号。",[359,360,361,362],{"key":20,"text":201,"correct":22},{"key":24,"text":199,"correct":26},{"key":153,"text":203,"correct":26},{"key":156,"text":205,"correct":26},{"id":364,"libraryId":5,"type":365,"typeLabel":366,"stem":367,"options":368,"answer":377,"analysis":27},973731,2,"多选题","消防控制室图形显示装置应具有火灾报警和消防联动控制的历史纪录功能，记录应包括（）等信息。",[369,371,373,375],{"key":20,"text":370,"correct":22},"报警时间",{"key":24,"text":372,"correct":22},"报警部位",{"key":153,"text":374,"correct":22},"复位操作",{"key":156,"text":376,"correct":22},"消防联动设备的启动动作反馈","ABCD",{"id":379,"libraryId":5,"type":365,"typeLabel":366,"stem":380,"options":381,"answer":390,"analysis":27},973732,"根据安装喷头的结构形式，自动喷水灭火系统可分为（）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"开式系统",{"key":24,"text":385,"correct":22},"闭式系统",{"key":153,"text":387,"correct":26},"湿式系统",{"key":156,"text":389,"correct":26},"干式系统","AB",{"id":392,"libraryId":5,"type":365,"typeLabel":366,"stem":393,"options":394,"answer":401,"analysis":27},973733,"以下哪些属于闭式系统（）。",[395,396,397,399],{"key":20,"text":387,"correct":22},{"key":24,"text":389,"correct":22},{"key":153,"text":398,"correct":22},"预作用系统",{"key":156,"text":400,"correct":26},"雨淋系统","ABC",{"id":403,"libraryId":5,"type":365,"typeLabel":366,"stem":404,"options":405,"answer":401,"analysis":27},973734,"末端试水装置的组成（）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"试水阀",{"key":24,"text":409,"correct":22},"试水接头",{"key":153,"text":411,"correct":22},"压力表",{"key":156,"text":331,"correct":26},{"id":414,"libraryId":5,"type":365,"typeLabel":366,"stem":415,"options":416,"answer":421,"analysis":27},973735,"末端试水装置可以检验（）的充水时间。",[417,418,419,420],{"key":20,"text":389,"correct":22},{"key":24,"text":387,"correct":26},{"key":153,"text":398,"correct":22},{"key":156,"text":400,"correct":26},"AC",{"id":423,"libraryId":5,"type":365,"typeLabel":366,"stem":424,"options":425,"answer":377,"analysis":27},973736,"发生火灾时，自动喷水灭火系统组件的工作状态有（）。",[426,428,430,432],{"key":20,"text":427,"correct":22},"受高温烟气作用喷头动作喷水，且出水压力不低于0．05MPa",{"key":24,"text":429,"correct":22},"报警阀开启，打通输水通道",{"key":153,"text":431,"correct":22},"压力开关动作，连锁启动消防水泵，并向火灾自动报警系统发出压力开关动作信号",{"key":156,"text":433,"correct":22},"水力警铃动作并发出声报警信号，该声响在3m远处声强不低于70dB",{"id":435,"libraryId":5,"type":365,"typeLabel":366,"stem":436,"options":437,"answer":446,"analysis":27},973737,"以下哪些符合末端试水装置准工作状态要求：（）。",[438,440,442,444],{"key":20,"text":439,"correct":26},"试水阀平时应处于开启状态，外观完好，无锈蚀、渗漏",{"key":24,"text":441,"correct":22},"工作环境便于操作和观察，排水设施完好",{"key":153,"text":443,"correct":22},"压力表铅封完好，表盘、指针无损伤",{"key":156,"text":445,"correct":22},"各项测试功能正常","BCD",{"id":448,"libraryId":5,"type":365,"typeLabel":366,"stem":449,"options":450,"answer":459,"analysis":27},973738,"机械加压送风系统送风口分为：（）。",[451,453,455,457],{"key":20,"text":452,"correct":22},"常开式",{"key":24,"text":454,"correct":22},"常闭式",{"key":153,"text":456,"correct":26},"半开式",{"key":156,"text":458,"correct":22},"自垂百叶式","ABD",{"id":461,"libraryId":5,"type":365,"typeLabel":366,"stem":462,"options":463,"answer":446,"analysis":27},973739,"集中火灾报警控制器在接收到火灾探测器或其他火灾报警触发器发出的火灾报警信号后，根据预定的控制逻辑向相关消防联动控制装置发出控制信号，控制各类消防设备实现（）等消防保护功能。",[464,466,468,470],{"key":20,"text":465,"correct":26},"救助伤员",{"key":24,"text":467,"correct":22},"人员疏散",{"key":153,"text":469,"correct":22},"限制火势蔓延",{"key":156,"text":471,"correct":22},"自动灭火",{"id":473,"libraryId":5,"type":365,"typeLabel":366,"stem":474,"options":475,"answer":401,"analysis":27},973740,"对于联动型火灾报警控制器，有时把（）等传递的信号设为监管信号。",[476,477,478,479],{"key":20,"text":331,"correct":22},{"key":24,"text":333,"correct":22},{"key":153,"text":335,"correct":22},{"key":156,"text":323,"correct":26},[481,484,487,490,493,496],{"id":144,"name":482,"category":7,"favorite":483},"领导干部任职前廉政法规知识测试题",92,{"id":485,"name":486,"category":7,"favorite":144},595,"建筑结构与设备",{"id":488,"name":489,"category":7,"favorite":144},715,"招标采购专业知识与法律法规",{"id":491,"name":492,"category":7,"favorite":144},848,"市政方向-通用基础",{"id":494,"name":495,"category":7,"favorite":8},534,"BIM工程师",{"id":497,"name":495,"category":7,"favorite":8},535]