[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":571},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,15,50,2486,[13,35,48,60,73,86,98,110,119,131,144,157,170,180,191,199,212,226,234,246,258,270,282,290,301,313,323,335,347,359,371,383,392,401,409,419,431,439,451,463,476,488,500,512,524,535,543,553,559,565],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},973641,2,"多选题","碳酸氢钠干粉灭火器可以灭（）类火灾。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","A类",false,{"key":24,"text":25,"correct":26},"B","B类",true,{"key":28,"text":29,"correct":26},"C","C类",{"key":31,"text":32,"correct":26},"D","E类","BCD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},973642,"水基型灭火器分为（）。",[39,41,43,45],{"key":20,"text":40,"correct":22},"气泡型",{"key":24,"text":42,"correct":26},"清水型",{"key":28,"text":44,"correct":26},"泡沫型",{"key":31,"text":46,"correct":22},"干粉型","BC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":33,"analysis":34},973643,"室内消火栓箱由消防水枪、消防水带和（）组成。",[52,54,56,58],{"key":20,"text":53,"correct":22},"手动报警按钮",{"key":24,"text":55,"correct":26},"室内消火栓",{"key":28,"text":57,"correct":26},"消火栓报警按钮",{"key":31,"text":59,"correct":26},"消火栓箱体",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":34},973644,"手动报警按钮分为（）。",[64,66,68,70],{"key":20,"text":65,"correct":26},"可复位报警按钮",{"key":24,"text":67,"correct":22},"不可复位报警按钮",{"key":28,"text":69,"correct":26},"玻璃破碎报警按钮",{"key":31,"text":71,"correct":22},"不可玻璃破碎报警按钮","AC",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":85,"analysis":34},973645,"消防电话分为（）。",[77,79,81,83],{"key":20,"text":78,"correct":22},"内线电话",{"key":24,"text":80,"correct":22},"外线电话",{"key":28,"text":82,"correct":26},"编码型消防电话",{"key":31,"text":84,"correct":26},"非编码型消防电话","CD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":33,"analysis":34},973646,"防火门按材质分为（）和其他材质防火门。",[90,92,94,96],{"key":20,"text":91,"correct":22},"特级",{"key":24,"text":93,"correct":26},"木质",{"key":28,"text":95,"correct":26},"钢木质",{"key":31,"text":97,"correct":26},"钢质",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":47,"analysis":34},973647,"防火门按工作状态分为（）。",[102,104,106,108],{"key":20,"text":103,"correct":22},"电动防火门",{"key":24,"text":105,"correct":26},"常开式防火门",{"key":28,"text":107,"correct":26},"常闭式防火门",{"key":31,"text":109,"correct":22},"手动防火门",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":33,"analysis":34},973648,"防火卷帘按材质分为（）。",[114,115,116,117],{"key":20,"text":93,"correct":22},{"key":24,"text":91,"correct":26},{"key":28,"text":97,"correct":26},{"key":31,"text":118,"correct":26},"无机纤维复合",{"id":120,"libraryId":5,"type":15,"typeLabel":16,"stem":121,"options":122,"answer":47,"analysis":34},973649,"防火卷帘按下降方式分为（）。",[123,125,127,129],{"key":20,"text":124,"correct":22},"垂直降",{"key":24,"text":126,"correct":26},"一步降",{"key":28,"text":128,"correct":26},"两步降",{"key":31,"text":130,"correct":22},"三步降",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":143,"analysis":34},973650,"火源分为（）和光线照射与聚焦、绝热压缩和化学反应放热。",[135,137,139,141],{"key":20,"text":136,"correct":26},"高温物体",{"key":24,"text":138,"correct":26},"电火花",{"key":28,"text":140,"correct":26},"明火焰",{"key":31,"text":142,"correct":26},"撞击与摩擦","ABCD",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":156,"analysis":34},973651,"海湾主机在（）状态下不能操作自检。",[148,150,152,154],{"key":20,"text":149,"correct":26},"火警",{"key":24,"text":151,"correct":22},"故障",{"key":28,"text":153,"correct":26},"反馈",{"key":31,"text":155,"correct":26},"监管","ACD",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":169,"analysis":34},973652,"以下不属于干式报警阀组组成部分的有（）。",[161,163,165,167],{"key":20,"text":162,"correct":26},"延时器",{"key":24,"text":164,"correct":22},"信号蝶阀",{"key":28,"text":166,"correct":22},"水力警铃",{"key":31,"text":168,"correct":26},"电磁阀","AD",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":85,"analysis":34},973653,"以下不属于湿式报警阀组组成部分的有（）。",[174,175,176,178],{"key":20,"text":162,"correct":22},{"key":24,"text":164,"correct":22},{"key":28,"text":177,"correct":26},"注水漏斗",{"key":31,"text":179,"correct":26},"手动紧急启动站",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":190,"analysis":34},973654,"以下不属于预作用报警阀组组成部分的有（）。",[184,185,186,188],{"key":20,"text":168,"correct":22},{"key":24,"text":162,"correct":26},{"key":28,"text":187,"correct":22},"预作用报警阀",{"key":31,"text":189,"correct":26},"水流指示器","BD",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":85,"analysis":34},973655,"以下不属于雨淋报警阀组组成部分的有（）。",[195,196,197,198],{"key":20,"text":168,"correct":22},{"key":24,"text":179,"correct":22},{"key":28,"text":177,"correct":26},{"key":31,"text":162,"correct":26},{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":211,"analysis":34},973656,"以下玻璃球喷头的动作温度与色标对应不正确的有（）。",[203,205,207,209],{"key":20,"text":204,"correct":26},"黄色（57℃）",{"key":24,"text":206,"correct":26},"绿色（141℃）",{"key":28,"text":208,"correct":22},"红色（68℃）",{"key":31,"text":210,"correct":26},"橙色（93℃）","ABD",{"id":213,"libraryId":5,"type":214,"typeLabel":215,"stem":216,"options":217,"answer":20,"analysis":34},973657,1,"单选题","下图喷头按照灵敏度分类是（）。",[218,220,222,224],{"key":20,"text":219,"correct":26},"快速响应喷头",{"key":24,"text":221,"correct":22},"直立型喷头",{"key":28,"text":223,"correct":22},"边墙型喷头",{"key":31,"text":225,"correct":22},"隐蔽型喷头",{"id":227,"libraryId":5,"type":214,"typeLabel":215,"stem":228,"options":229,"answer":24,"analysis":34},973658,"以下位置安装的是两步降防火卷帘的是（）。",[230,232],{"key":20,"text":231,"correct":22},"货物分隔区（非疏散通道）",{"key":24,"text":233,"correct":26},"疏散通道",{"id":235,"libraryId":5,"type":214,"typeLabel":215,"stem":236,"options":237,"answer":28,"analysis":34},973659,"下列哪个是末端试水装置的测试方法（）。",[238,240,242,244],{"key":20,"text":239,"correct":22},"开启末端试水装置阀门，出水压力不应低于0.05MPa（兆帕），水流指示器、报警阀、压力开关、水力警铃应动作。开启末端试水装置后5分钟内手动启动消防水泵。",{"key":24,"text":241,"correct":22},"开启末端试水装置阀门，出水压力不应低于0.04MPa（兆帕），水流指示器、报警阀、压力表、水力警铃应动作。开启末端试水装置后5分钟内自动启动消防水泵。",{"key":28,"text":243,"correct":26},"开启末端试水装置阀门，出水压力不应低于0.05MPa（兆帕），水流指示器、报警阀、压力开关、水力警铃应动作。开启末端试水装置后5分钟内自动启动消防水泵。",{"key":31,"text":245,"correct":22},"开启末端试水装置阀门，出水压力不应低于0.05MPa（兆帕），水流指示器、报警阀、压力开关、水力警铃，信号蝶阀应动作。开启末端试水装置后5分钟内自动启动消防水泵。",{"id":247,"libraryId":5,"type":214,"typeLabel":215,"stem":248,"options":249,"answer":28,"analysis":34},973660,"主控部分与多功能板或节点设备发生通信故障时，（）指示灯亮。",[250,252,254,256],{"key":20,"text":251,"correct":22},"系统故障",{"key":24,"text":253,"correct":22},"公共故障",{"key":28,"text":255,"correct":26},"通讯故障",{"key":31,"text":257,"correct":22},"漏电报警",{"id":259,"libraryId":5,"type":214,"typeLabel":215,"stem":260,"options":261,"answer":28,"analysis":34},973661,"主电工作指示灯（绿色）点亮，控制器由AC（）v电源供电工作。",[262,264,266,268],{"key":20,"text":263,"correct":22},"24",{"key":24,"text":265,"correct":22},"12",{"key":28,"text":267,"correct":26},"220",{"key":31,"text":269,"correct":22},"360",{"id":271,"libraryId":5,"type":214,"typeLabel":215,"stem":272,"options":273,"answer":31,"analysis":34},973662,"（）是开式系统。",[274,276,278,280],{"key":20,"text":275,"correct":22},"湿式系统",{"key":24,"text":277,"correct":22},"干式系统",{"key":28,"text":279,"correct":22},"预作用系统",{"key":31,"text":281,"correct":26},"雨淋系统",{"id":283,"libraryId":5,"type":214,"typeLabel":215,"stem":284,"options":285,"answer":24,"analysis":34},973663,"（）在准工作状态时配水管道内充满有压气体。",[286,287,288,289],{"key":20,"text":275,"correct":22},{"key":24,"text":277,"correct":26},{"key":28,"text":281,"correct":22},{"key":31,"text":279,"correct":22},{"id":291,"libraryId":5,"type":214,"typeLabel":215,"stem":292,"options":293,"answer":20,"analysis":34},973664,"（）是湿式报警阀组的核心组件。",[294,296,298,300],{"key":20,"text":295,"correct":26},"湿式报警阀",{"key":24,"text":297,"correct":22},"延迟器",{"key":28,"text":299,"correct":22},"压力开关",{"key":31,"text":166,"correct":22},{"id":302,"libraryId":5,"type":214,"typeLabel":215,"stem":303,"options":304,"answer":20,"analysis":34},973665,"（）状态是指火灾发生时洒水喷头动作喷水以及日常开展各项功能检查和测试等工作时的状态。",[305,307,309,311],{"key":20,"text":306,"correct":26},"正常工作状态",{"key":24,"text":308,"correct":22},"准工作状态",{"key":28,"text":310,"correct":22},"故障状态",{"key":31,"text":312,"correct":22},"伺应状态",{"id":314,"libraryId":5,"type":214,"typeLabel":215,"stem":315,"options":316,"answer":28,"analysis":34},973666,"（）在水流作用下动作，并通过信号模块向火灾自动报警系统发出报警信号，通报位置分区。",[317,318,320,321],{"key":20,"text":299,"correct":22},{"key":24,"text":319,"correct":22},"报警阀",{"key":28,"text":189,"correct":26},{"key":31,"text":322,"correct":22},"末端试水装置",{"id":324,"libraryId":5,"type":214,"typeLabel":215,"stem":325,"options":326,"answer":24,"analysis":34},973667,"排烟防火阀平时呈开启状态，火灾时当排烟管道内烟气温度达到（）时关闭。",[327,329,331,333],{"key":20,"text":328,"correct":22},"270℃",{"key":24,"text":330,"correct":26},"280℃",{"key":28,"text":332,"correct":22},"290℃",{"key":31,"text":334,"correct":22},"70℃",{"id":336,"libraryId":5,"type":214,"typeLabel":215,"stem":337,"options":338,"answer":28,"analysis":34},973668,"排烟管道隔热材料应为不燃材料，且与可燃物保持不小于（）mm的距离。",[339,341,343,345],{"key":20,"text":340,"correct":22},"130",{"key":24,"text":342,"correct":22},"140",{"key":28,"text":344,"correct":26},"150",{"key":31,"text":346,"correct":22},"160",{"id":348,"libraryId":5,"type":214,"typeLabel":215,"stem":349,"options":350,"answer":20,"analysis":34},973669,"防排烟系统风口边框与建筑装饰面贴合严密，远程控制执行器安装高度便于人员操作，一般距地面（）m，操作标识应清晰、正确。",[351,353,355,357],{"key":20,"text":352,"correct":26},"0．8-1．5",{"key":24,"text":354,"correct":22},"1．2-1．5",{"key":28,"text":356,"correct":22},"1．3-1．5",{"key":31,"text":358,"correct":22},"1．4-1．5",{"id":360,"libraryId":5,"type":214,"typeLabel":215,"stem":361,"options":362,"answer":24,"analysis":34},973670,"当被探测线路在1s内发生14个及以上半周期的故障电弧时，故障电弧探测器应能在（）秒内发出报警信号，点亮报警指示灯，向电气火灾监控设备发送报警信号。",[363,365,367,369],{"key":20,"text":364,"correct":22},"10",{"key":24,"text":366,"correct":26},"30",{"key":28,"text":368,"correct":22},"40",{"key":31,"text":370,"correct":22},"100",{"id":372,"libraryId":5,"type":214,"typeLabel":215,"stem":373,"options":374,"answer":24,"analysis":34},973671,"关闭电气火灾监控设备备用电源，电气火灾监控设备处于（）状态。",[375,377,379,381],{"key":20,"text":376,"correct":22},"主电工作，备电准工作",{"key":24,"text":378,"correct":26},"主电工作，备电故障",{"key":28,"text":380,"correct":22},"主备电同时工作",{"key":31,"text":382,"correct":22},"主电故障，备电工作",{"id":384,"libraryId":5,"type":214,"typeLabel":215,"stem":385,"options":386,"answer":31,"analysis":34},973672,"触发火灾报警触发器件发出火灾报警信号，使集中火灾报警控制器处于（）状态。",[387,388,389,391],{"key":20,"text":155,"correct":22},{"key":24,"text":151,"correct":22},{"key":28,"text":390,"correct":22},"屏蔽",{"key":31,"text":149,"correct":26},{"id":393,"libraryId":5,"type":214,"typeLabel":215,"stem":394,"options":395,"answer":20,"analysis":34},973673,"触发双信号，使集中火灾报警控制器根据预定的控制逻辑向相关消防联动控制装置发出（）信号。",[396,398,399,400],{"key":20,"text":397,"correct":26},"控制",{"key":24,"text":149,"correct":22},{"key":28,"text":155,"correct":22},{"key":31,"text":390,"correct":22},{"id":402,"libraryId":5,"type":214,"typeLabel":215,"stem":403,"options":404,"answer":28,"analysis":34},973674,"通过集中火灾报警控制器控制面板显示屏，在控制面板显示屏的右侧有信息显示列表，在列表上可以看到（）信息，同时可以看到编号和报警地点名称。",[405,406,407,408],{"key":20,"text":155,"correct":22},{"key":24,"text":151,"correct":22},{"key":28,"text":149,"correct":26},{"key":31,"text":390,"correct":22},{"id":410,"libraryId":5,"type":214,"typeLabel":215,"stem":411,"options":412,"answer":20,"analysis":34},973675,"当火警发生时，第一个信息标识“（）”就会显示红色，同时报警详细信息就会在上方信息栏以文字形式显示出来，在平面图中可以看到报警位置和编号。",[413,414,415,417],{"key":20,"text":149,"correct":26},{"key":24,"text":155,"correct":22},{"key":28,"text":416,"correct":22},"3火警监管",{"key":31,"text":418,"correct":22},"火警屏蔽",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":143,"analysis":34},973676,"湿式、干式自动喷水灭火系统主要由（）等组成。",[423,425,427,429],{"key":20,"text":424,"correct":26},"闭式喷头",{"key":24,"text":426,"correct":26},"报警阀组",{"key":28,"text":428,"correct":26},"水流报警装置",{"key":31,"text":430,"correct":26},"管道和供水设施",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":143,"analysis":34},973677,"湿式报警阀组的组成（）。",[435,436,437,438],{"key":20,"text":319,"correct":26},{"key":24,"text":297,"correct":26},{"key":28,"text":299,"correct":26},{"key":31,"text":166,"correct":26},{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":143,"analysis":34},973678,"末端试水装置有以下作用：（）。",[443,445,447,449],{"key":20,"text":444,"correct":26},"测试系统能否在开放一只喷头的最不利条件下可靠报警并正常启动",{"key":24,"text":446,"correct":26},"测试水流指示器、报警阀、压力开关、水力警铃的动作是否正常",{"key":28,"text":448,"correct":26},"检查配水管道是否畅通",{"key":31,"text":450,"correct":26},"测试系统最不利点处的工作压力是否正常",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":143,"analysis":34},973679,"自动喷水灭火系统工作状态检查判断方法有（）。",[455,457,459,461],{"key":20,"text":456,"correct":26},"开展组件外观检查",{"key":24,"text":458,"correct":26},"功能测试",{"key":28,"text":460,"correct":26},"直观判断",{"key":31,"text":462,"correct":26},"分析判断和技术对比",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":475,"analysis":34},973680,"（）应采用机械加压送风系统。",[467,469,471,473],{"key":20,"text":468,"correct":26},"大于50m的公共建筑、工业建筑",{"key":24,"text":470,"correct":26},"大于100m的住宅建筑",{"key":28,"text":472,"correct":22},"小于50米的公共建筑、工业建筑",{"key":31,"text":474,"correct":22},"小于100m的住宅建筑","AB",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":143,"analysis":34},973681,"机械加压送风系统主要由（）等组成。",[480,482,484,486],{"key":20,"text":481,"correct":26},"送风机",{"key":24,"text":483,"correct":26},"风道",{"key":28,"text":485,"correct":26},"送风口",{"key":31,"text":487,"correct":26},"电气控制柜",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":85,"analysis":34},973682,"挡烟垂壁按挡烟部件的刚度性能可分为：（）。",[492,494,496,498],{"key":20,"text":493,"correct":22},"固定式挡烟垂壁",{"key":24,"text":495,"correct":22},"活动式挡烟",{"key":28,"text":497,"correct":26},"柔性挡烟垂壁",{"key":31,"text":499,"correct":26},"刚性挡烟垂壁",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":475,"analysis":34},973683,"温度传感器按测量方式分为（）两大类。",[504,506,508,510],{"key":20,"text":505,"correct":26},"接触式",{"key":24,"text":507,"correct":26},"非接触式",{"key":28,"text":509,"correct":22},"热电阻",{"key":31,"text":511,"correct":22},"热电偶",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":523,"analysis":34},973684,"常用火灾报警触发设备由（）等。",[516,518,520,522],{"key":20,"text":517,"correct":26},"感烟感温探测器",{"key":24,"text":519,"correct":26},"手动火灾报警按钮",{"key":28,"text":521,"correct":26},"红外火焰探测器",{"key":31,"text":166,"correct":22},"ABC",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":211,"analysis":34},973685,"以下哪些是火灾联动设备（）。",[528,530,532,533],{"key":20,"text":529,"correct":26},"风机",{"key":24,"text":531,"correct":26},"水泵",{"key":28,"text":53,"correct":22},{"key":31,"text":534,"correct":26},"排烟系统",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":33,"analysis":34},973686,"常用火灾监管设备有（）等。",[539,540,541,542],{"key":20,"text":53,"correct":22},{"key":24,"text":299,"correct":26},{"key":28,"text":189,"correct":26},{"key":31,"text":164,"correct":26},{"id":544,"libraryId":5,"type":545,"typeLabel":546,"stem":547,"options":548,"answer":550,"analysis":34},973687,3,"判断题","集中火灾报警控制器具有其他辅助功能的控制指示设备。（）",[549,551],{"key":20,"text":550,"correct":26},"正确",{"key":24,"text":552,"correct":22},"错误",{"id":554,"libraryId":5,"type":545,"typeLabel":546,"stem":555,"options":556,"answer":552,"analysis":34},973688,"集中火灾报警控制器自检会影响非自检部位、探测区和控制器本身的火灾报警功能。（）",[557,558],{"key":20,"text":550,"correct":22},{"key":24,"text":552,"correct":26},{"id":560,"libraryId":5,"type":545,"typeLabel":546,"stem":561,"options":562,"answer":550,"analysis":34},973689,"控制器的电源部分应具有主电源和备用电源转换装置。",[563,564],{"key":20,"text":550,"correct":26},{"key":24,"text":552,"correct":22},{"id":566,"libraryId":5,"type":545,"typeLabel":546,"stem":567,"options":568,"answer":552,"analysis":34},973690,"系统程序处于故障状态时，公共故障指示灯亮。（）",[569,570],{"key":20,"text":550,"correct":22},{"key":24,"text":552,"correct":26},[572,575,578,581,584,587],{"id":214,"name":573,"category":7,"favorite":574},"领导干部任职前廉政法规知识测试题",92,{"id":576,"name":577,"category":7,"favorite":214},595,"建筑结构与设备",{"id":579,"name":580,"category":7,"favorite":214},715,"招标采购专业知识与法律法规",{"id":582,"name":583,"category":7,"favorite":214},848,"市政方向-通用基础",{"id":585,"name":586,"category":7,"favorite":8},534,"BIM工程师",{"id":588,"name":586,"category":7,"favorite":8},535]