[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":525},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,13,50,2486,[13,34,42,50,62,70,78,86,94,102,112,120,128,140,152,164,172,184,192,202,210,225,236,248,262,276,288,298,308,315,323,331,337,347,353,361,373,381,389,401,413,425,437,449,461,469,480,492,504,513],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},973540,1,"单选题","主机的关机顺序。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","主电电源开关，备电电源开关，控制器电源开关",false,{"key":24,"text":25,"correct":26},"B","控制器电源开关，备电电源开关，主电电源开关",true,{"key":28,"text":29,"correct":22},"C","在开机状态下，关掉主电电源开关，查看灯光显示区，主电是否故障，备电是否工作正常",{"key":31,"text":32,"correct":22},"D","主备电源开关,备电电源开关,控制器电源开关","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},973541,"主机的开机顺序。",[38,39,40,41],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"key":28,"text":29,"correct":22},{"key":31,"text":32,"correct":22},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":28,"analysis":33},973542,"主备电源如何切换。",[46,47,48,49],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":22},{"key":28,"text":29,"correct":26},{"key":31,"text":32,"correct":22},{"id":51,"libraryId":5,"type":15,"typeLabel":16,"stem":52,"options":53,"answer":24,"analysis":33},973543,"使火灾自动报警系统重新回到正常监视状态，是下列哪个操作的作用是（）。",[54,56,58,60],{"key":20,"text":55,"correct":22},"消音",{"key":24,"text":57,"correct":26},"复位",{"key":28,"text":59,"correct":22},"自检",{"key":31,"text":61,"correct":22},"屏蔽",{"id":63,"libraryId":5,"type":15,"typeLabel":16,"stem":64,"options":65,"answer":28,"analysis":33},973544,"检查火灾报警控制器报警功能是否正常，是下列哪个操作的作用是（）。",[66,67,68,69],{"key":20,"text":55,"correct":22},{"key":24,"text":57,"correct":22},{"key":28,"text":59,"correct":26},{"key":31,"text":61,"correct":22},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},973545,"外部设备现场不能及时维修，先把设备屏蔽，待维修后再将设备恢复，是下列哪个操作的作用是（）。",[74,75,76,77],{"key":20,"text":55,"correct":22},{"key":24,"text":57,"correct":22},{"key":28,"text":59,"correct":22},{"key":31,"text":61,"correct":26},{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":20,"analysis":33},973546,"保证再有报警信号时，再次启动报警，是下列哪个操作的作用是（）。",[82,83,84,85],{"key":20,"text":55,"correct":26},{"key":24,"text":57,"correct":22},{"key":28,"text":59,"correct":22},{"key":31,"text":61,"correct":22},{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":20,"analysis":33},973547,"小明在某商场消控室工作，故障声响起的时候首先应该怎么做。",[90,91,92,93],{"key":20,"text":55,"correct":26},{"key":24,"text":57,"correct":22},{"key":28,"text":59,"correct":22},{"key":31,"text":61,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},973548,"小明发现故障设备不能得到及时的维修时应该怎么做。",[98,99,100,101],{"key":20,"text":55,"correct":22},{"key":24,"text":57,"correct":22},{"key":28,"text":59,"correct":22},{"key":31,"text":61,"correct":26},{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":24,"analysis":33},973549,"当感烟探测器误报火警主机处于火警状态时，应该怎么做。",[106,108,110,111],{"key":20,"text":107,"correct":22},"查询火警信息",{"key":24,"text":109,"correct":26},"消音并复位",{"key":28,"text":59,"correct":22},{"key":31,"text":61,"correct":22},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":28,"analysis":33},973550,"小明发现主机故障声不响，需要进行（）操作来检查主机是否正常。",[116,117,118,119],{"key":20,"text":55,"correct":22},{"key":24,"text":57,"correct":22},{"key":28,"text":59,"correct":26},{"key":31,"text":61,"correct":22},{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":28,"analysis":33},973551,"当小明需要进行主备电源切换时，应该怎么做。（）。",[124,125,126,127],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":22},{"key":28,"text":29,"correct":26},{"key":31,"text":32,"correct":22},{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":28,"analysis":33},973552,"防火阀安装在什么位置。",[132,134,136,138],{"key":20,"text":133,"correct":22},"防火阀安装在机械排烟系统管道上",{"key":24,"text":135,"correct":22},"防火阀安装在防排烟系统管道上",{"key":28,"text":137,"correct":26},"防火阀安装在机械正压送风系统管道上",{"key":31,"text":139,"correct":22},"防火阀安装在管道上",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":20,"analysis":33},973553,"安装在机械正压送风系统管道里的阀为。",[144,146,148,150],{"key":20,"text":145,"correct":26},"防火阀",{"key":24,"text":147,"correct":22},"排烟防火阀",{"key":28,"text":149,"correct":22},"排烟阀",{"key":31,"text":151,"correct":22},"送风阀",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":24,"analysis":33},973554,"机械防排烟系统管道排烟防火阀的动作温度是多少。",[156,158,160,162],{"key":20,"text":157,"correct":22},"70℃",{"key":24,"text":159,"correct":26},"280℃",{"key":28,"text":161,"correct":22},"73℃",{"key":31,"text":163,"correct":22},"141℃",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":24,"analysis":33},973555,"动作温度为280℃的阀为。",[168,169,170,171],{"key":20,"text":145,"correct":22},{"key":24,"text":147,"correct":26},{"key":28,"text":149,"correct":22},{"key":31,"text":151,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":20,"analysis":33},973556,"排烟防火阀安装在什么位置。",[176,178,180,182],{"key":20,"text":177,"correct":26},"安装在机械排烟系统管道上",{"key":24,"text":179,"correct":22},"安装在管道的位置上",{"key":28,"text":181,"correct":22},"一般安装在跨越防火分区或楼板的墙体位置上",{"key":31,"text":183,"correct":22},"安装在机械正压送风系统管道上",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":24,"analysis":33},973557,"安装在机械排烟系统管道上的阀为。",[188,189,190,191],{"key":20,"text":145,"correct":22},{"key":24,"text":147,"correct":26},{"key":28,"text":149,"correct":22},{"key":31,"text":151,"correct":22},{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":24,"analysis":33},973558,"机械正压送风系统管道防火阀的动作温度是多少。",[196,198,199,201],{"key":20,"text":197,"correct":22},"68℃",{"key":24,"text":157,"correct":26},{"key":28,"text":200,"correct":22},"75℃",{"key":31,"text":159,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":20,"analysis":33},973559,"动作温度为70℃的为。",[206,207,208,209],{"key":20,"text":145,"correct":26},{"key":24,"text":147,"correct":22},{"key":28,"text":149,"correct":22},{"key":31,"text":151,"correct":22},{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},973560,"以下不属于防火门自检的有（）。",[214,216,218,220,222],{"key":20,"text":215,"correct":22},"防火门的释放器是否灵敏",{"key":24,"text":217,"correct":26},"防火门下是否有堆积物，影响开启",{"key":28,"text":219,"correct":22},"看防火门关闭时，是否按照顺序进行关闭",{"key":31,"text":221,"correct":22},"防火门关闭后的密封性",{"key":223,"text":224,"correct":22},"E","分别触发两个相关的火灾探测器，查看电动防火门的关闭效果及反馈信号",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":24,"analysis":33},973561,"以下不属于防火门巡查内容的有（）。",[229,231,232,234],{"key":20,"text":230,"correct":22},"门前是否堆放物品影响开启",{"key":24,"text":215,"correct":26},{"key":28,"text":233,"correct":22},"防火门的门框、门扇、闭门器等部件是否完好无损，是否具备良好的隔烟、隔火作用",{"key":31,"text":235,"correct":22},"防火门能否在闭门器的作用下自动关闭，电动防火门当电磁力释放后是否按照顺序顺畅关闭",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":20,"analysis":33},973562,"钢制双片防火卷帘的耐火极限是（）。",[240,242,244,246],{"key":20,"text":241,"correct":26},"不小于2h",{"key":24,"text":243,"correct":22},"不小于3h",{"key":28,"text":245,"correct":22},"不小于4h",{"key":31,"text":247,"correct":22},"36-72h",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":223,"analysis":33},973564,"以下不属于防火卷帘门的巡查的有（）。",[252,254,256,258,260],{"key":20,"text":253,"correct":22},"防火卷帘下是否堆放物品，影响降落",{"key":24,"text":255,"correct":22},"防火卷帘控制面板，门体是否完好无损",{"key":28,"text":257,"correct":22},"防火卷帘是否处于正常的上升状态",{"key":31,"text":259,"correct":22},"防火卷帘门所对应的感烟探测器、感温探测器是否完好无损",{"key":223,"text":261,"correct":26},"机械拉链是否能控制卷帘门的升降",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},973565,"以下不属于防火卷帘自检的有（）。",[266,268,270,272,274],{"key":20,"text":267,"correct":22},"手动按钮操作方法（按向下、停止、向上，是否相应动作）",{"key":24,"text":269,"correct":26},"防火卷帘的控制面板、门体是否完好无损",{"key":28,"text":271,"correct":22},"机械拉链是否控制卷帘门的升降",{"key":31,"text":273,"correct":22},"分别触发两个相关的火灾探测器",{"key":223,"text":275,"correct":22},"消防控制室手动输出遥控信号",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":31,"analysis":33},973566,"以下哪个部件是常开式防火门独有的。",[280,282,284,286],{"key":20,"text":281,"correct":22},"闭门器",{"key":24,"text":283,"correct":22},"顺序器",{"key":28,"text":285,"correct":22},"电动闭门器",{"key":31,"text":287,"correct":26},"释放器",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":20,"analysis":33},973567,"甲级防火门的耐火极限是（）。",[292,294,296],{"key":20,"text":293,"correct":26},"不小于1.5h",{"key":24,"text":295,"correct":22},"不小于1h",{"key":28,"text":297,"correct":22},"不小于0.5h",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":31,"analysis":33},973568,"下图喷头玻璃球动作温度为（）。",[302,304,306,307],{"key":20,"text":303,"correct":22},"57℃",{"key":24,"text":305,"correct":22},"93℃",{"key":28,"text":197,"correct":22},{"key":31,"text":163,"correct":26},{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":310,"answer":20,"analysis":33},973569,[311,312,313,314],{"key":20,"text":305,"correct":26},{"key":24,"text":197,"correct":22},{"key":28,"text":157,"correct":22},{"key":31,"text":163,"correct":22},{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":20,"analysis":33},973570,"以下位置安装的是一步降防火卷帘的是（）。",[319,321],{"key":20,"text":320,"correct":26},"非疏散通道",{"key":24,"text":322,"correct":22},"疏散通道",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":20,"analysis":33},973571,"货物分隔区上安装的防火卷帘是（）。",[327,329],{"key":20,"text":328,"correct":26},"一步降",{"key":24,"text":330,"correct":22},"两步降",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":24,"analysis":33},973572,"疏散通道上安装的防火卷帘是（）。",[335,336],{"key":20,"text":328,"correct":22},{"key":24,"text":330,"correct":26},{"id":338,"libraryId":5,"type":339,"typeLabel":340,"stem":341,"options":342,"answer":346,"analysis":33},973573,3,"判断题","防火卷帘按照材质分为：钢制、木质、特级、无机纤维复合四种防火卷帘。",[343,345],{"key":20,"text":344,"correct":22},"正确",{"key":24,"text":346,"correct":26},"错误",{"id":348,"libraryId":5,"type":339,"typeLabel":340,"stem":349,"options":350,"answer":346,"analysis":33},973574,"防火门按照材质分为：钢制防火门、木质防火门、钢木制防火门和特级防火门。",[351,352],{"key":20,"text":344,"correct":22},{"key":24,"text":346,"correct":26},{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":355,"answer":24,"analysis":33},973575,[356,357,358,360],{"key":20,"text":305,"correct":22},{"key":24,"text":197,"correct":26},{"key":28,"text":359,"correct":22},"94℃",{"key":31,"text":157,"correct":22},{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":33},973576,"下图喷头按照灵敏度分类是（）。",[365,367,369,371],{"key":20,"text":366,"correct":22},"快速响应喷头",{"key":24,"text":368,"correct":22},"直立型喷头",{"key":28,"text":370,"correct":26},"早期抑制快速响应喷头",{"key":31,"text":372,"correct":22},"隐蔽型喷头",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},973577,"一般安装在图书馆，档案室，计算机房的是下列哪个系统（）。",[377,378,379,380],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":20,"analysis":33},973578,"一般安装在火灾水平迅速蔓延的场所是下列哪个系统（）。",[385,386,387,388],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":20,"analysis":33},973579,"湿式系统组成有哪些（）。",[393,395,397,399],{"key":20,"text":394,"correct":26},"给水设备供水设施及管网、湿式报警阀组、水流指示器、闭式喷头、末端试水装置",{"key":24,"text":396,"correct":22},"给水设备供水设施及管网、湿式报警阀组、水流指示器",{"key":28,"text":398,"correct":22},"给水设备供水设施及管网、湿式报警阀组、水流指示器、闭式喷头、末端试水装置充气设备",{"key":31,"text":400,"correct":22},"给水设备供水设施及管网、湿式报警阀组、闭式喷头、火灾探测器",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":28,"analysis":33},973580,"湿式报警阀组组成（）。",[405,407,409,411],{"key":20,"text":406,"correct":22},"湿式报警阀、水力警铃、压力开关、信号蝶阀、延时器",{"key":24,"text":408,"correct":22},"湿式报警阀、水力警铃、压力开关、压力表、电磁阀、延时器",{"key":28,"text":410,"correct":26},"湿式报警阀、水力警铃、压力开关、压力表、信号蝶阀、延时器",{"key":31,"text":412,"correct":22},"湿式报警阀、水力警铃、压力开关、压力表、信号蝶阀、注水漏斗",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":20,"analysis":33},973581,"湿式系统配水管道内的充装物是什么（）。",[417,419,421,423],{"key":20,"text":418,"correct":26},"有压水",{"key":24,"text":420,"correct":22},"有压气",{"key":28,"text":422,"correct":22},"无压气",{"key":31,"text":424,"correct":22},"无压水",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":24,"analysis":33},973582,"湿式系统适用在什么场所（）。",[429,431,433,435],{"key":20,"text":430,"correct":22},"环境温度在-4~70℃之间的场所",{"key":24,"text":432,"correct":26},"环境温度在4~70℃之间的场所",{"key":28,"text":434,"correct":22},"环境温度在40~70℃之间的场所",{"key":31,"text":436,"correct":22},"环境温度在低于4℃高于70℃之间的场所",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":28,"analysis":33},973583,"干式系统组成有哪些（）。",[441,443,445,447],{"key":20,"text":442,"correct":22},"给水设备供水设施及管网、干式报警阀组、水流指示器、闭式喷头、末端试水装置",{"key":24,"text":444,"correct":22},"给水设备供水设施及管网、干式报警阀组、水流指示器、闭式喷头、末端试水装置、电磁阀充气设备",{"key":28,"text":446,"correct":26},"给水设备供水设施及管网、干式报警阀组、水流指示器、闭式喷头、末端试水装置、充气设备",{"key":31,"text":448,"correct":22},"给水设备供水设施及管网、干式报警阀组、水流指示器、开式喷头、末端试水装置、充气设备",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":31,"analysis":33},973584,"干式报警阀阀组组成（）。",[453,455,457,459],{"key":20,"text":454,"correct":22},"干式报警阀、水力警铃、压力开关、压力表、信号蝶阀、注水漏斗、电磁阀",{"key":24,"text":456,"correct":22},"干式报警阀、水力警铃、压力开关、压力表、信号蝶阀、手动紧急启动站",{"key":28,"text":458,"correct":22},"干式报警阀、水力警铃、压力开关、信号蝶阀、注水漏斗、电磁阀、手动紧急启动站",{"key":31,"text":460,"correct":26},"干式报警阀、水力警铃、压力开关、压力表、信号蝶阀、注水漏斗",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":28,"analysis":33},973585,"干式系统配水管道内的充装物是什么（）。",[465,466,467,468],{"key":20,"text":418,"correct":22},{"key":24,"text":422,"correct":22},{"key":28,"text":420,"correct":26},{"key":31,"text":424,"correct":22},{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":20,"analysis":33},973586,"干式系统适用在什么场所（）。",[473,475,477,478],{"key":20,"text":474,"correct":26},"环境温度在低于4℃，高于70℃的场所",{"key":24,"text":476,"correct":22},"环境温度在低于-4℃，高于70℃的场所",{"key":28,"text":430,"correct":22},{"key":31,"text":479,"correct":22},"环境温度在4~70℃的场所",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":24,"analysis":33},973587,"预作用系统组成有哪些（）。",[484,486,488,490],{"key":20,"text":485,"correct":22},"给水设备供水设施及管网、预作用报警阀组、水流指示器、闭式喷头、电磁阀、末端试水装置、充气设备",{"key":24,"text":487,"correct":26},"给水设备供水设施及管网、预作用报警阀组、水流指示器、闭式喷头、电磁阀、末端试水装置、火灾探测器、充气设备",{"key":28,"text":489,"correct":22},"给水设备供水设施及管网、预作用报警阀组、水流指示器、闭式喷头、电磁阀、末端试水装置、火灾探测器",{"key":31,"text":491,"correct":22},"给水设备供水设施及管网、预作用报警阀组、水流指示器、开式喷头、电磁阀、末端试水装置、火灾探测器、充气设备",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":31,"analysis":33},973588,"预作用报警阀阀组组成（）。",[496,498,500,502],{"key":20,"text":497,"correct":22},"预作用报警阀（湿式报警阀+雨淋报警阀）、水力警铃、压力开关、压力表、信号蝶阀、注水漏斗、电磁阀",{"key":24,"text":499,"correct":22},"预作用报警阀（湿式报警阀+雨淋报警阀）、水力警铃、压力开关、压力表、信号蝶阀、注水漏斗、手动紧急启动站",{"key":28,"text":501,"correct":22},"预作用报警阀（湿式报警阀+雨淋报警阀）、水力警铃、压力开关、压力表、信号蝶阀、电磁阀、手动紧急启动站",{"key":31,"text":503,"correct":26},"预作用报警阀（湿式报警阀+雨淋报警阀）、水力警铃、压力开关、压力表、信号蝶阀、注水漏斗、电磁阀、手动紧急启动站",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":20,"analysis":33},973589,"预作用系统配水管道内的充装物是什么（）。",[508,510,511,512],{"key":20,"text":509,"correct":26},"有压气或无压气",{"key":24,"text":418,"correct":22},{"key":28,"text":422,"correct":22},{"key":31,"text":424,"correct":22},{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":24,"analysis":33},973590,"预作用系统适用在什么场所（）。",[517,519,521,523],{"key":20,"text":518,"correct":22},"严禁管道漏水，严禁系统误喷的场所，可以代替湿式系统，多用于保护档案室，计算机，贵重纸张和票证的场所。",{"key":24,"text":520,"correct":26},"严禁管道漏水，严禁系统误喷的场所，可以代替干式系统，多用于保护档案室，计算机，贵重纸张和票证的场所。",{"key":28,"text":522,"correct":22},"允许管道漏水，允许系统误喷的场所，可以代替干式系统，多用于保护档案室，计算机，贵重纸张和票证的场所。",{"key":31,"text":524,"correct":22},"严禁管道漏水，严禁系统误喷的场所，可以代替干式系统，多用于火灾水平蔓延的的场所。",[526,529,532,535,538,541],{"id":15,"name":527,"category":7,"favorite":528},"领导干部任职前廉政法规知识测试题",92,{"id":530,"name":531,"category":7,"favorite":15},595,"建筑结构与设备",{"id":533,"name":534,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":536,"name":537,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":539,"name":540,"category":7,"favorite":8},534,"BIM工程师",{"id":542,"name":540,"category":7,"favorite":8},535]