[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":595},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,1,50,2486,[13,33,45,57,69,81,93,105,117,129,139,151,162,174,186,198,210,221,233,245,254,269,282,295,307,319,331,343,356,368,380,393,405,416,428,440,452,464,473,485,496,506,517,530,543,555,567,577,583,589],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":19,"analysis":32},972931,"单选题","多线控制盘与火灾报警控制器连接，一台火灾报警控制器（联动型）可设置（）多线控制盘。",[18,22,26,29],{"key":19,"text":20,"correct":21},"A","多个",true,{"key":23,"text":24,"correct":25},"B","3个",false,{"key":27,"text":28,"correct":25},"C","2个",{"key":30,"text":31,"correct":25},"D","1个","",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":30,"analysis":32},972932,"下列（），由多线控制盘控制。",[37,39,41,43],{"key":19,"text":38,"correct":25},"排烟阀",{"key":23,"text":40,"correct":25},"排烟防火阀",{"key":27,"text":42,"correct":25},"防火阀",{"key":30,"text":44,"correct":21},"防烟风机",{"id":46,"libraryId":5,"type":9,"typeLabel":15,"stem":47,"options":48,"answer":23,"analysis":32},972933,"线型光束感烟火灾探测器的光束轴线至顶棚的垂直距离宜为（）。",[49,51,53,55],{"key":19,"text":50,"correct":25},"0．1～1．0m",{"key":23,"text":52,"correct":21},"0．3～1．0m",{"key":27,"text":54,"correct":25},"2．2～2．5m",{"key":30,"text":56,"correct":25},"1．0m以内",{"id":58,"libraryId":5,"type":9,"typeLabel":15,"stem":59,"options":60,"answer":27,"analysis":32},972934,"线型光束感烟火灾探测器的发射器和接收器之间的距离不宜超过（）。",[61,63,65,67],{"key":19,"text":62,"correct":25},"20m",{"key":23,"text":64,"correct":25},"50m",{"key":27,"text":66,"correct":21},"100m",{"key":30,"text":68,"correct":25},"200m",{"id":70,"libraryId":5,"type":9,"typeLabel":15,"stem":71,"options":72,"answer":23,"analysis":32},972935,"测试线型感温火灾探测器火灾报警、故障报警功能(以线型缆式感温探测器为例），使用温度不低于（）的热水持续对线型缆式感温火灾探测器的感温电缆进行加热。",[73,75,77,79],{"key":19,"text":74,"correct":25},"45℃",{"key":23,"text":76,"correct":21},"54℃",{"key":27,"text":78,"correct":25},"68℃",{"key":30,"text":80,"correct":25},"79℃",{"id":82,"libraryId":5,"type":9,"typeLabel":15,"stem":83,"options":84,"answer":19,"analysis":32},972936,"测试线型感温火灾探测器应在（）以内发出火灾报警信号，探测器红色报警确认灯点亮，火灾报警控制器显示火警信号。",[85,87,89,91],{"key":19,"text":86,"correct":21},"30s",{"key":23,"text":88,"correct":25},"25s",{"key":27,"text":90,"correct":25},"20s",{"key":30,"text":92,"correct":25},"15s",{"id":94,"libraryId":5,"type":9,"typeLabel":15,"stem":95,"options":96,"answer":23,"analysis":32},972937,"火灾显示盘应设置在出入口等明显和便于操作的部位。当采用壁挂方式安装时，其底边距地高度宜为（）。",[97,99,101,103],{"key":19,"text":98,"correct":25},"1．0-1．3m",{"key":23,"text":100,"correct":21},"1．3-1．5m",{"key":27,"text":102,"correct":25},"1．5-1．8m",{"key":30,"text":104,"correct":25},"1．6-1．8m",{"id":106,"libraryId":5,"type":9,"typeLabel":15,"stem":107,"options":108,"answer":27,"analysis":32},972938,"湿式系统适用于（）。",[109,111,113,115],{"key":19,"text":110,"correct":25},"严禁误喷的场所",{"key":23,"text":112,"correct":25},"火灾水平方向迅速蔓延的场所",{"key":27,"text":114,"correct":21},"4℃-70℃的场所",{"key":30,"text":116,"correct":25},"低于4℃或者高于70℃的场所",{"id":118,"libraryId":5,"type":9,"typeLabel":15,"stem":119,"options":120,"answer":27,"analysis":32},972939,"湿式系统组成不包括（）。",[121,123,125,127],{"key":19,"text":122,"correct":25},"闭式喷头",{"key":23,"text":124,"correct":25},"末端试水装置",{"key":27,"text":126,"correct":21},"充气设备",{"key":30,"text":128,"correct":25},"水流指示器",{"id":130,"libraryId":5,"type":9,"typeLabel":15,"stem":131,"options":132,"answer":27,"analysis":32},972940,"干式系统组成不包括（）。",[133,134,135,137],{"key":19,"text":122,"correct":25},{"key":23,"text":124,"correct":25},{"key":27,"text":136,"correct":21},"雨淋喷头",{"key":30,"text":138,"correct":25},"干式报警阀",{"id":140,"libraryId":5,"type":9,"typeLabel":15,"stem":141,"options":142,"answer":27,"analysis":32},972941,"消防泵组电气控制柜还应设置机械应急启泵功能．机械应急启动时，应确保消防水泵在报警（）内正常工作。",[143,145,147,149],{"key":19,"text":144,"correct":25},"2min",{"key":23,"text":146,"correct":25},"3min",{"key":27,"text":148,"correct":21},"5min",{"key":30,"text":150,"correct":25},"10min",{"id":152,"libraryId":5,"type":9,"typeLabel":15,"stem":153,"options":154,"answer":19,"analysis":32},972942,"对于采用临时高压消防给水系统的高层或多层建筑，当高位消防水箱的设置不能满足系统最不利点处的静压要求时，应在建筑消防给水系统中（），并采取配套设置气压罐等防止稳压泵频繁启停的技术措施。",[155,157,158,160],{"key":19,"text":156,"correct":21},"增（稳）压设施",{"key":23,"text":126,"correct":25},{"key":27,"text":159,"correct":25},"电磁阀",{"key":30,"text":161,"correct":25},"压力开关",{"id":163,"libraryId":5,"type":9,"typeLabel":15,"stem":164,"options":165,"answer":23,"analysis":32},972943,"消防泵组电气控制柜在平时应使消防水泵处于（）启泵状态。",[166,168,170,172],{"key":19,"text":167,"correct":25},"手动",{"key":23,"text":169,"correct":21},"自动",{"key":27,"text":171,"correct":25},"启动",{"key":30,"text":173,"correct":25},"停动",{"id":175,"libraryId":5,"type":9,"typeLabel":15,"stem":176,"options":177,"answer":23,"analysis":32},972944,"任一应急照明控制器直接控制灯具的总数量不应大于（）只。",[178,180,182,184],{"key":19,"text":179,"correct":25},"1600",{"key":23,"text":181,"correct":21},"3200",{"key":27,"text":183,"correct":25},"5600",{"key":30,"text":185,"correct":25},"6400",{"id":187,"libraryId":5,"type":9,"typeLabel":15,"stem":188,"options":189,"answer":23,"analysis":32},972945,"收到消防电话分机呼叫时，消防电话总机在（）s内发出声、光呼叫指示信号，指示该消防电话分机为呼叫状态，声指示信号能手动消除。",[190,192,194,196],{"key":19,"text":191,"correct":25},"1",{"key":23,"text":193,"correct":21},"3",{"key":27,"text":195,"correct":25},"5",{"key":30,"text":197,"correct":25},"7",{"id":199,"libraryId":5,"type":9,"typeLabel":15,"stem":200,"options":201,"answer":27,"analysis":32},972946,"消防应急广播能按预定程序向保护区域广播火灾事故有关信息，广播语音清晰，距扬声器正前方（）处应急广播的播放声压级不小于65d B，且不大于115dB。",[202,204,206,208],{"key":19,"text":203,"correct":25},"1m",{"key":23,"text":205,"correct":25},"2m",{"key":27,"text":207,"correct":21},"3m",{"key":30,"text":209,"correct":25},"5m",{"id":211,"libraryId":5,"type":9,"typeLabel":15,"stem":212,"options":213,"answer":30,"analysis":32},972947,"防火卷帘的手动按钮盒底边距地高度宜为（）m。",[214,216,217,219],{"key":19,"text":215,"correct":25},"0．5",{"key":23,"text":191,"correct":25},{"key":27,"text":218,"correct":25},"1．2",{"key":30,"text":220,"correct":21},"1．5",{"id":222,"libraryId":5,"type":9,"typeLabel":15,"stem":223,"options":224,"answer":19,"analysis":32},972948,"消防应急广播发生故障时，能在（）s内发出故障声、光信号。",[225,227,229,231],{"key":19,"text":226,"correct":21},"100",{"key":23,"text":228,"correct":25},"110",{"key":27,"text":230,"correct":25},"115",{"key":30,"text":232,"correct":25},"120",{"id":234,"libraryId":5,"type":9,"typeLabel":15,"stem":235,"options":236,"answer":23,"analysis":32},972949,"火灾自动报警系统应在（）内联动开启相应防烟分区的全部排烟阀、排烟口、排烟风机和补风设施，并在30s内自动关闭与排烟无关的通风、空调系统。",[237,239,241,243],{"key":19,"text":238,"correct":25},"10",{"key":23,"text":240,"correct":21},"15",{"key":27,"text":242,"correct":25},"20",{"key":30,"text":244,"correct":25},"26",{"id":246,"libraryId":5,"type":9,"typeLabel":15,"stem":247,"options":248,"answer":30,"analysis":32},972950,"监控器应能接收来自火灾自动报警系统的火灾报警信号，并在（）内向电动闭门器或电磁释放器发出启动信号，点亮启动总指示灯。",[249,250,251,252],{"key":19,"text":238,"correct":25},{"key":23,"text":240,"correct":25},{"key":27,"text":242,"correct":25},{"key":30,"text":253,"correct":21},"30",{"id":255,"libraryId":5,"type":256,"typeLabel":257,"stem":258,"options":259,"answer":268,"analysis":32},972951,2,"多选题","消防联动控制器常用的联动控制方式主要有（）。",[260,262,264,266],{"key":19,"text":261,"correct":21},"自动控制和手动控制",{"key":23,"text":263,"correct":21},"直接控制和间接控制",{"key":27,"text":265,"correct":21},"总线控制和直线控制",{"key":30,"text":267,"correct":25},"集中控制和区域控制","ABC",{"id":270,"libraryId":5,"type":256,"typeLabel":257,"stem":271,"options":272,"answer":281,"analysis":32},972952,"线型感温火灾探测器按敏感部件形式分为缆式、（）线型感温探测器。",[273,275,277,279],{"key":19,"text":274,"correct":21},"空气管式",{"key":23,"text":276,"correct":21},"分布式光纤",{"key":27,"text":278,"correct":21},"光栅光纤",{"key":30,"text":280,"correct":21},"线式多点型","ABCD",{"id":283,"libraryId":5,"type":256,"typeLabel":257,"stem":284,"options":285,"answer":294,"analysis":32},972953,"线型感温火灾探测器按可恢复性能分为（）线型感温探测器。",[286,288,290,292],{"key":19,"text":287,"correct":21},"可恢复式",{"key":23,"text":289,"correct":21},"不可恢复式",{"key":27,"text":291,"correct":25},"玻璃破碎式",{"key":30,"text":293,"correct":25},"缆式","AB",{"id":296,"libraryId":5,"type":256,"typeLabel":257,"stem":297,"options":298,"answer":281,"analysis":32},972954,"符合下列条件的场所，不宜选择线型光束感烟火灾探测器（）。",[299,301,303,305],{"key":19,"text":300,"correct":21},"有大量粉尘、水雾滞留的场所",{"key":23,"text":302,"correct":21},"可能产生蒸气和油雾的场所",{"key":27,"text":304,"correct":21},"在正常情况下有烟滞留的场所",{"key":30,"text":306,"correct":21},"固定探测器的建筑结构由于振动等原因会产生较大位移的场所",{"id":308,"libraryId":5,"type":256,"typeLabel":257,"stem":309,"options":310,"answer":268,"analysis":32},972955,"以下符合线型光束感烟火灾探测器的设置规定的是（）。",[311,313,315,317],{"key":19,"text":312,"correct":21},"探测器的光束轴线至顶棚的垂直距离宜为0．3-1．0m；",{"key":23,"text":314,"correct":21},"相邻两组探测器的水平距离不应大于14m；",{"key":27,"text":316,"correct":21},"探测器的发射器和接收器之间的距离不宜超过100m；",{"key":30,"text":318,"correct":25},"探测器至侧墙水平距离不应大于5m",{"id":320,"libraryId":5,"type":256,"typeLabel":257,"stem":321,"options":322,"answer":268,"analysis":32},972956,"火灾显示盘按显示方式分为（）。",[323,325,327,329],{"key":19,"text":324,"correct":21},"数字式",{"key":23,"text":326,"correct":21},"汉字\u002F英文式",{"key":27,"text":328,"correct":21},"图形式",{"key":30,"text":330,"correct":25},"液晶式",{"id":332,"libraryId":5,"type":256,"typeLabel":257,"stem":333,"options":334,"answer":294,"analysis":32},972957,"火灾显示盘按供电方式分为（）。",[335,337,339,341],{"key":19,"text":336,"correct":21},"直流供电型",{"key":23,"text":338,"correct":21},"交流供电型",{"key":27,"text":340,"correct":25},"交变供电型",{"key":30,"text":342,"correct":25},"自备发电型",{"id":344,"libraryId":5,"type":256,"typeLabel":257,"stem":345,"options":346,"answer":355,"analysis":32},972958,"下列关于湿式自动喷水灭火系统描述错误的是（）。",[347,349,351,353],{"key":19,"text":348,"correct":25},"适用于4℃-70℃环境",{"key":23,"text":350,"correct":21},"安装有开式喷头",{"key":27,"text":352,"correct":21},"无末端试水装置",{"key":30,"text":354,"correct":25},"准工作状态时系统侧管道充满用于启动系统的有压水","BC",{"id":357,"libraryId":5,"type":256,"typeLabel":257,"stem":358,"options":359,"answer":367,"analysis":32},972959,"下列关于干式自动喷水灭火系统描述错误的是（）。",[360,362,364,366],{"key":19,"text":361,"correct":21},"喷头开启后立即喷水",{"key":23,"text":363,"correct":25},"安装有闭式喷头",{"key":27,"text":365,"correct":25},"有末端试水装置",{"key":30,"text":354,"correct":21},"AD",{"id":369,"libraryId":5,"type":256,"typeLabel":257,"stem":370,"options":371,"answer":294,"analysis":32},972960,"消防增（稳）压设施按安装位置可分为（）。",[372,374,376,378],{"key":19,"text":373,"correct":21},"上置式",{"key":23,"text":375,"correct":21},"下置式",{"key":27,"text":377,"correct":25},"左置式",{"key":30,"text":379,"correct":25},"右置式",{"id":381,"libraryId":5,"type":256,"typeLabel":257,"stem":382,"options":383,"answer":392,"analysis":32},972961,"消防增（稳）压设施按所服务的系统可分为（）消防增（稳）压设施。",[384,386,388,390],{"key":19,"text":385,"correct":21},"消火栓用",{"key":23,"text":387,"correct":21},"自动喷水灭火系统用",{"key":27,"text":389,"correct":25},"泡沫用",{"key":30,"text":391,"correct":21},"消火栓与自动喷水灭火系统合用","ABD",{"id":394,"libraryId":5,"type":256,"typeLabel":257,"stem":395,"options":396,"answer":268,"analysis":32},972962,"排烟防火阀可通过（）控制。",[397,399,401,403],{"key":19,"text":398,"correct":21},"温控自动关闭",{"key":23,"text":400,"correct":21},"电动关闭",{"key":27,"text":402,"correct":21},"手动关闭",{"key":30,"text":404,"correct":25},"手动复位",{"id":406,"libraryId":5,"type":256,"typeLabel":257,"stem":407,"options":408,"answer":268,"analysis":32},972963,"排烟口、常闭送风口可通过（）控制。",[409,411,413,415],{"key":19,"text":410,"correct":21},"通过火灾自动报警系统自动启动",{"key":23,"text":412,"correct":21},"消防控制室手动操作",{"key":27,"text":414,"correct":21},"现场手动操作",{"key":30,"text":404,"correct":25},{"id":417,"libraryId":5,"type":256,"typeLabel":257,"stem":418,"options":419,"answer":281,"analysis":32},972964,"风机电气控制柜的主要功能是（）。",[420,422,424,426],{"key":19,"text":421,"correct":21},"指示功能",{"key":23,"text":423,"correct":21},"转换功能",{"key":27,"text":425,"correct":21},"风机启\u002F停功能",{"key":30,"text":427,"correct":21},"其他功能",{"id":429,"libraryId":5,"type":256,"typeLabel":257,"stem":430,"options":431,"answer":367,"analysis":32},972965,"防火门按日常启闭状态可分为（）。",[432,434,436,438],{"key":19,"text":433,"correct":21},"常开防火门",{"key":23,"text":435,"correct":25},"木质防火门",{"key":27,"text":437,"correct":25},"钢质防火门",{"key":30,"text":439,"correct":21},"常闭防火门",{"id":441,"libraryId":5,"type":256,"typeLabel":257,"stem":442,"options":443,"answer":294,"analysis":32},972966,"防火卷帘按照帘面数量分类（）。",[444,446,448,450],{"key":19,"text":445,"correct":21},"单面",{"key":23,"text":447,"correct":21},"双面",{"key":27,"text":449,"correct":25},"多面",{"key":30,"text":451,"correct":25},"三面",{"id":453,"libraryId":5,"type":256,"typeLabel":257,"stem":454,"options":455,"answer":268,"analysis":32},972967,"防火卷帘按照材质可分为（）。",[456,458,460,462],{"key":19,"text":457,"correct":21},"钢质",{"key":23,"text":459,"correct":21},"无机纤维",{"key":27,"text":461,"correct":21},"特级",{"key":30,"text":463,"correct":25},"木质",{"id":465,"libraryId":5,"type":256,"typeLabel":257,"stem":466,"options":467,"answer":281,"analysis":32},972968,"自动排烟窗可通过（）控制。",[468,469,470,471],{"key":19,"text":410,"correct":21},{"key":23,"text":412,"correct":21},{"key":27,"text":414,"correct":21},{"key":30,"text":472,"correct":21},"通过温控释放装置启动，释放温度应大于环境温度30°C且小于100°C",{"id":474,"libraryId":5,"type":256,"typeLabel":257,"stem":475,"options":476,"answer":268,"analysis":32},972969,"消防应急照明灯具按用途分类（）。",[477,479,481,483],{"key":19,"text":478,"correct":21},"消防应急标志灯具",{"key":23,"text":480,"correct":21},"消防应急照明灯具",{"key":27,"text":482,"correct":21},"消防应急照明标志复合灯具",{"key":30,"text":484,"correct":25},"消防指示灯",{"id":486,"libraryId":5,"type":256,"typeLabel":257,"stem":487,"options":488,"answer":268,"analysis":32},972970,"消防应急照明灯具按应急控制方式分类（）。",[489,491,493,495],{"key":19,"text":490,"correct":21},"自带电源型消防应急灯具",{"key":23,"text":492,"correct":21},"集中电源型消防应急灯具",{"key":27,"text":494,"correct":21},"子母型消防应急灯具",{"key":30,"text":484,"correct":25},{"id":497,"libraryId":5,"type":256,"typeLabel":257,"stem":498,"options":499,"answer":367,"analysis":32},972971,"消防应急照明灯具按按应急控制方式分类（）。",[500,502,503,504],{"key":19,"text":501,"correct":21},"集中控制型消防应急灯具",{"key":23,"text":480,"correct":25},{"key":27,"text":482,"correct":25},{"key":30,"text":505,"correct":21},"非集中控制型消防应急灯具",{"id":507,"libraryId":5,"type":256,"typeLabel":257,"stem":508,"options":509,"answer":281,"analysis":32},972972,"挡烟垂壁可通过（）控制。",[510,512,514,515],{"key":19,"text":511,"correct":21},"挡烟垂壁接收到消防控制中心的控制信号后下降至挡烟工作位置",{"key":23,"text":513,"correct":21},"当配接的烟感探测器报警后，挡烟垂壁自动下降至挡烟工作位置",{"key":27,"text":414,"correct":21},{"key":30,"text":516,"correct":21},"系统断电时，挡烟垂壁自动下降至设计位置",{"id":518,"libraryId":5,"type":256,"typeLabel":257,"stem":519,"options":520,"answer":529,"analysis":32},972974,"扬声器一般分为（）。",[521,523,525,527],{"key":19,"text":522,"correct":21},"壁挂式",{"key":23,"text":524,"correct":25},"立柜式",{"key":27,"text":526,"correct":21},"吸顶式",{"key":30,"text":528,"correct":25},"琴台式","AC",{"id":531,"libraryId":5,"type":256,"typeLabel":257,"stem":532,"options":533,"answer":542,"analysis":32},972975,"排烟系统主要有（）两种形式。",[534,536,538,540],{"key":19,"text":535,"correct":25},"自然通风",{"key":23,"text":537,"correct":25},"机械加压送风系统",{"key":27,"text":539,"correct":21},"自然排烟",{"key":30,"text":541,"correct":21},"机械排烟","CD",{"id":544,"libraryId":5,"type":256,"typeLabel":257,"stem":545,"options":546,"answer":281,"analysis":32},972976,"消防电话总机具有（）功能。",[547,549,551,553],{"key":19,"text":548,"correct":21},"通话录音",{"key":23,"text":550,"correct":21},"信息记录查询",{"key":27,"text":552,"correct":21},"自检",{"key":30,"text":554,"correct":21},"故障报警灯",{"id":556,"libraryId":5,"type":256,"typeLabel":257,"stem":557,"options":558,"answer":281,"analysis":32},972977,"消防电话系统由消防电话总机和（）组成，",[559,561,563,565],{"key":19,"text":560,"correct":21},"消防电话分机",{"key":23,"text":562,"correct":21},"消防电话插孔",{"key":27,"text":564,"correct":21},"消防电话手柄",{"key":30,"text":566,"correct":21},"专用消防电话线路",{"id":568,"libraryId":5,"type":569,"typeLabel":570,"stem":571,"options":572,"answer":576,"analysis":32},972978,3,"判断题","手动状态下，当集中火灾报警控制器、消防联动控制器收到火灾报警信息时，会在屏幕上显示火灾发生的位置信息、点亮火警指示灯、发出火警报警音，且联动启动声光报警、消防广播及所控制的现场消防设备。",[573,575],{"key":19,"text":574,"correct":25},"正确",{"key":23,"text":576,"correct":21},"错误",{"id":578,"libraryId":5,"type":569,"typeLabel":570,"stem":579,"options":580,"answer":576,"analysis":32},972979,"自动状态下，当集中火灾报警控制器、消防联动控制器收到火灾报警信息时，不会在屏幕上显示火灾发生的位置信息、点亮火警指示灯、发出火警报警音，但是会按照预设的逻辑关系联动启动声光报警、消防广播及所控制的现场消防设备。",[581,582],{"key":19,"text":574,"correct":25},{"key":23,"text":576,"correct":21},{"id":584,"libraryId":5,"type":569,"typeLabel":570,"stem":585,"options":586,"answer":574,"analysis":32},972980,"当控制器处于火警状态时，确认现场发生火灾后，不允许将控制器从自动状态切换为手动状态。",[587,588],{"key":19,"text":574,"correct":21},{"key":23,"text":576,"correct":25},{"id":590,"libraryId":5,"type":569,"typeLabel":570,"stem":591,"options":592,"answer":574,"analysis":32},972981,"总线控制盘的每一个按键对应一个总线控制模块，对消防设备的控制是由控制模块实现的。",[593,594],{"key":19,"text":574,"correct":21},{"key":23,"text":576,"correct":25},[596,599,602,605,608,611],{"id":9,"name":597,"category":7,"favorite":598},"领导干部任职前廉政法规知识测试题",92,{"id":600,"name":601,"category":7,"favorite":9},595,"建筑结构与设备",{"id":603,"name":604,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":606,"name":607,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":609,"name":610,"category":7,"favorite":8},534,"BIM工程师",{"id":612,"name":610,"category":7,"favorite":8},535]