[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-975436":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},975436,704,2,"多选题","下列关于末端试水装置的作用，说法正确的是（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","检验自动喷水灭火系统的可靠性",true,{"key":16,"text":17,"correct":14},"B","测试水流指示器、报警阀、压力开关、水力警铃的动作是否正常",{"key":19,"text":20,"correct":14},"C","测试系统最不利点处的工作压力",{"key":22,"text":23,"correct":24},"D","测试火灾报警控制器的主电与备电切换功能",false,{"key":26,"text":27,"correct":14},"E","用于检测干式系统和预作用系统的充水时间","ABCE","末端试水装置的作用是检验自动喷水灭火系统的可靠性，测试系统能否在开放一只喷头的最不利条件下可靠报警并正常启动，测试水流指示器、报警阀、压力开关、水力警铃的动作是否正常，配水管道是否畅通，以及系统最不利点处的工作压力等，也可以用于检测干式系统和预作用系统的充水时间。",{"id":6,"name":31,"category":32,"favorite":33},"中级技能","建筑工程",0]