[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-975153":3},{"question":4,"library":29},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":27,"analysis":28},975153,704,2,"多选题","下列关于自动喷水灭火系统连锁控制的测试方法描述正确的有（ ）。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","通过开启末端试水装置模拟喷头动作",true,{"key":16,"text":17,"correct":14},"B","通过开启报警阀泄水阀模拟喷头动作",{"key":19,"text":20,"correct":14},"C","使报警阀在压差作用下开启，压力水流入报警管路",{"key":22,"text":23,"correct":14},"D","压力开关作后直接启动消防水泵",{"key":25,"text":26,"correct":14},"E","也可通过开启警铃试验阀，直接驱动压力开关动作并连锁启动消防水泵","ABCDE","连锁控制的测试方法：通过开启末端试水装置、报警阀泄水阀或专用测试管路等方式模拟喷头动作，使报警阀在压差作用下开启，压力水流入报警管路，压力开关动作后直接启动消防水泵。也可通过开启警铃试验阀，直接驱动压力开关动作并连锁启动消防水泵。",{"id":6,"name":30,"category":31,"favorite":32},"中级技能","建筑工程",0]