[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-975087":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},975087,704,2,"多选题","下列关于线型红外光束感烟火灾探测器的安装说法错误的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","当探测区域的高度不大于20m时，光束轴线至顶棚的垂直距离宜为0.1m",false,{"key":16,"text":17,"correct":18},"B","当探测区域的高度大于20m时，光束轴线距探测区域的地（楼）面高度不宜超过14m",true,{"key":20,"text":21,"correct":18},"C","发射器和接收器之间的探测区域长度不宜超过100m",{"key":23,"text":24,"correct":18},"D","相邻两组探测器光束轴线的水平距离不应大于14m。探测器光束轴线至侧墙水平距离不应大于7m，且不应小于0.5m",{"key":26,"text":27,"correct":18},"E","发射器和接收器之间的光路上应无遮挡物或干扰源","BCDE","线型红外光束感烟火灾探测器的安装，应符合下列要求： （1）当探测区域的高度不大于20m时，光束轴线至顶棚的垂直距离宜为0.3～1.0m；当探测区域的高度大于20m时，光束轴线距探测区域的地（楼）面高度不宜超过20m。 （2）发射器和接收器之间的探测区域长度不宜超过100m。 （3）相邻两组探测器光束轴线的水平距离不应大于14m。探测器光束轴线至侧墙水平距离不应大于7m，且不应小于0.5m。 （4）发射器和接收器之间的光路上应无遮挡物或干扰源。 （5）发射器和接收器应安装牢固，并不应产生位移。",{"id":6,"name":31,"category":32,"favorite":33},"中级技能","建筑工程",0]