[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-974907":3},{"question":4,"library":29},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":27,"analysis":28},974907,704,2,"多选题","检测发现，机械加压送风系统风机风量不足，下列属于其风量不足的可能原因是（ ）。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","管道内阀门未打开",true,{"key":16,"text":17,"correct":14},"B","调节阀门开度不够",{"key":19,"text":20,"correct":14},"C","风机传动带松弛",{"key":22,"text":23,"correct":14},"D","叶轮与轴的连接松动",{"key":25,"text":26,"correct":14},"E","风口开启过多","ABCDE","故障现象：风量不足，原因分析： （1）管道内阀门未打开； （2）调节阀门开度不够； （3）风机传动带松弛； （4）叶轮与轴的连接松动； （5）电源电压低、达不到转速或相序接反造成风机反转； （6）风管过长或配用的风机风量过小； （7）风管、软连接破损或连接口漏气； （8）进风或出风口、风井、风管堵塞； （9）风口开启过多。",{"id":6,"name":30,"category":31,"favorite":32},"中级技能","建筑工程",0]