[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-974746":3},{"question":4,"library":20},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":17,"analysis":19},974746,704,3,"判断题","消防泵组电气控制柜、联动控制设备的控制模式设定在“自动”状态会导致稳压泵不能正常启动",[11,15],{"key":12,"text":13,"correct":14},"A","正确",false,{"key":16,"text":17,"correct":18},"B","错误",true,"故障现象：稳压泵不能正常启动。原因分析：（1）稳压泵启泵压力设定不正确；（2）稳压泵启停的压力信号开关控制不能正常工作；（3）消防联动控制设备中的控制模块损坏；（4）消防泵组电气控制柜、联动控制设备的控制模式未设定在“自动”状态；（5）灭火后稳压泵处于停止状态。",{"id":6,"name":21,"category":22,"favorite":23},"中级技能","建筑工程",0]