[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-974698":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},974698,704,2,"多选题","下列属于干式系统空压机启动频繁的原因包括（ ）",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","干式系统空压机启停压力设定不正确",true,{"key":16,"text":17,"correct":14},"B","充气管路连接处松动",{"key":19,"text":20,"correct":14},"C","报警阀气室相关管路处有渗漏点",{"key":22,"text":23,"correct":14},"D","系统侧管网有渗漏点",{"key":25,"text":26,"correct":27},"E","水源侧压力不足，导致干式报警阀迟开",false,"ABCD","故障现象：干式系统空压机启动频繁。原因分析： （1）干式系统空压机启停压力设定不正确； （2）充气管路连接处松动； （3）报警阀气室相关管路处有渗漏点； （4）系统侧管网有渗漏点。 维修方法： （1）按设计要求重新调整干式系统空压机启停压力； （2）检查并紧固充气管路各连接处； （3）用肥皂水检查报警阀与相关管路连接处，管路阀门处有无气体渗漏，检查管路控制阀的启闭状态，连接不严密的按维修程序重新安装，阀门损坏的进行更换，阀门关闭不严密的关闭到位； （4）排查系统侧管网渗漏点并进行维修。",{"id":6,"name":31,"category":32,"favorite":33},"中级技能","建筑工程",0]