[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-974595":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},974595,704,2,"多选题","下列关于消防设备末端配电装置自动空气开关保养要求说法正确的是（ ）。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","接线应紧固，无破损及烧焦现象",true,{"key":16,"text":17,"correct":14},"B","开关动作灵活，开关的指示位置与实际位置一致，开关的手动和自动操作正常，电气、机械联锁正常可靠",{"key":19,"text":20,"correct":14},"C","所有螺栓应紧固",{"key":22,"text":23,"correct":14},"D","触头表面应清洁，无氧化层，接触紧密，分合可靠",{"key":25,"text":26,"correct":27},"E","相间及相对地绝缘电阻不大于1MΩ",false,"ABCD","消防设备末端配电装置自动空气开关保养要求： （1）设备外观应清洁干净； （2）接线应紧固，无破损及烧焦现象； （3）机构应灵活可靠； （4）所有螺栓应紧固； （5）触头表面应清洁，无氧化层，接触紧密，分合可靠； （6）相间及相对地绝缘电阻不低于1MΩ； （7）开关动作灵活，开关的指示位置与实际位置一致，开关的手动和自动操作正常，电气、机械联锁正常可靠。",{"id":6,"name":31,"category":32,"favorite":33},"中级技能","建筑工程",0]