[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-974580":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},974580,704,2,"多选题","下列关于湿式、干式自动喷水灭火系统报警阀组保养要求说法正确的是（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","报警阀组外观完好，标识清晰，并注明系统名称和保护区域",true,{"key":16,"text":17,"correct":14},"B","阀组组件齐全，表面无裂纹、损伤、锈蚀和渗漏",{"key":19,"text":20,"correct":14},"C","阀瓣密封垫清洁无损伤，阀座平整完好，报警孔畅通、无沉沙",{"key":22,"text":23,"correct":24},"D","阀前压力指示正常，各项测试功能正常，排水正常，报警阀、延迟器、压力开关、水力警铃等动作正常",false,{"key":26,"text":27,"correct":24},"E","湿式系统的充气设备、排气装置及其控制装置的外观标识无磨损，压力显示正常，补气功能正常","ABC","湿式、干式自动喷水灭火系统报警阀组保养要求： （1）报警阀组外观完好，标识清晰，并注明系统名称和保护区域； （2）阀组组件齐全，表面无裂纹、损伤、锈蚀和渗漏； （3）阀瓣密封垫清洁无损伤，阀座平整完好，报警孔畅通、无沉沙； （4）各阀门启闭状态正确，启闭标识明显，锁具完好，信号阀反馈信号正确； （5）阀前、后压力指示正常，各项测试功能正常，排水正常，报警阀、延迟器、压力开关、水力警铃等动作正常； （6）干式系统的充气设备、排气装置及其控制装置的外观标识无磨损，压力显示正常，补气功能正常等。",{"id":6,"name":31,"category":32,"favorite":33},"中级技能","建筑工程",0]