[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-974160":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},974160,704,2,"多选题","下列关于机械排烟系统的组件的说法正确的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","排烟防火阀平时呈开启状态",true,{"key":16,"text":17,"correct":18},"B","排烟阀平时呈开启状态",false,{"key":20,"text":21,"correct":18},"C","排烟防火阀平时呈关闭状态",{"key":23,"text":24,"correct":14},"D","排烟阀平时呈关闭状态",{"key":26,"text":27,"correct":14},"E","排烟口通常设置在防烟分区内需要排烟的走道、房间的顶棚或靠近顶棚的墙面上","ADE","排烟防火阀是安装在机械排烟系统的管道上，平时呈开启状态（故A正确，C错误），火灾时当排烟管道内烟气温度达到280℃时关闭。排烟阀是安装在机械排烟系统各支管端部（烟气吸入口）处，平时呈关闭状态（故B错误，D正确）并满足漏风量要求，火灾时可手动和电动启闭，起排烟作用的阀门，一般由阀体、叶片、执行机构等部件组成。排烟口是带有装饰口或进行过装饰处理的排烟阀，是机械排烟系统中烟气的入口，通常设置在防烟分区内需要排烟的走道、房间的顶棚或靠近顶棚的墙面上（故E正确）。",{"id":6,"name":31,"category":32,"favorite":33},"中级技能","建筑工程",0]