[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-703-39":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":495},{"id":5,"name":6,"category":7,"favorite":8},703,"基础知识（通用）","建筑工程",0,39,50,2862,[13,34,46,58,70,80,88,96,105,117,125,133,141,149,159,167,175,183,194,206,218,227,239,251,259,271,286,299,312,324,337,349,357,365,374,383,395,407,419,429,435,441,447,453,459,465,471,477,483,489],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},971954,1,"单选题","雨淋系统主要由（）雨淋阀启动装置、雨淋阀组、管道及供水设施等组成。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","开式喷头",true,{"key":24,"text":25,"correct":26},"B","闭式喷头",false,{"key":28,"text":29,"correct":26},"C","直立喷头",{"key":31,"text":32,"correct":26},"D","下垂喷头","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},971955,"气体灭火系统是以气体为主要灭火介质的灭火系统，通过这些气体在（）建立起灭火浓度实现灭火。",[38,40,42,44],{"key":20,"text":39,"correct":26},"整个防护区内",{"key":24,"text":41,"correct":26},"保护对象周围的局部区域",{"key":28,"text":43,"correct":22},"整个防护区内或保护对象周围的局部区域",{"key":31,"text":45,"correct":26},"局部防护区",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},971956,"（）是一种氮气、氩气、CO2气体组成的混合气体（其中含52%的N2、40%的Ar、8%的CO2）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"IG-541",{"key":24,"text":53,"correct":26},"IG-54",{"key":28,"text":55,"correct":26},"IG-01",{"key":31,"text":57,"correct":26},"IG-04",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},971957,"由于惰性气体纯粹来自自然界，是一种无毒、无色、无味、惰性及不导电的纯“绿色”压缩气体，故惰性气体灭火系统又称为（）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"二氧化碳气体灭火系统",{"key":24,"text":65,"correct":26},"热气溶胶灭火系统",{"key":28,"text":67,"correct":22},"洁净气体灭火系统",{"key":31,"text":69,"correct":26},"惰性气体灭火系统",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},971958,"（）适用于扑救灭火前可切断气源的气体火灾，液体火灾或石蜡、沥青等可熔化的固体火灾，固体表面火灾及棉毛、织物、纸张等部分固体深位火灾，电气火灾。",[74,76,78,79],{"key":20,"text":75,"correct":22},"二氧化碳灭火系统",{"key":24,"text":77,"correct":26},"七氟丙烷灭火系统",{"key":28,"text":69,"correct":26},{"key":31,"text":65,"correct":26},{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":24,"analysis":33},971959,"（）可用于扑救电气火灾，液体火灾或可熔化的固体火灾，固体表面火灾，灭火前应能切断气源的气体火灾。",[84,85,86,87],{"key":20,"text":75,"correct":26},{"key":24,"text":77,"correct":22},{"key":28,"text":69,"correct":26},{"key":31,"text":65,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":28,"analysis":33},971960,"（）适用于扑救A类（表面火）、B类、C类及电气火灾，可用于保护经常有人的场所。",[92,93,94,95],{"key":20,"text":75,"correct":26},{"key":24,"text":77,"correct":26},{"key":28,"text":69,"correct":22},{"key":31,"text":65,"correct":26},{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":31,"analysis":33},971961,"（）不应设置在人员密集场所、有爆炸危险性的场所及有超净要求的场所，K型及其他型热气溶胶预制灭火系统不得用于电子计算机房、通信机房等场所。",[100,101,102,103],{"key":20,"text":75,"correct":26},{"key":24,"text":77,"correct":26},{"key":28,"text":69,"correct":26},{"key":31,"text":104,"correct":22},"热气溶胶预制灭火系统",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":20,"analysis":33},971962,"（）是指按一定的应用条件进行设计计算，将灭火剂从储存装置经由干管、支管输送至喷放组件实施喷放的灭火系统。",[109,111,113,115],{"key":20,"text":110,"correct":22},"管网灭火系统",{"key":24,"text":112,"correct":26},"预制灭火系统",{"key":28,"text":114,"correct":26},"全淹没气体灭火系统",{"key":31,"text":116,"correct":26},"局部应用气体灭火系统",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":24,"analysis":33},971963,"（）不设储瓶间，储气瓶及整个装置均设置在保护区内，安装灵活方便，外形美观且轻便可移动，适用于较小的、无特殊要求的防护区。",[121,122,123,124],{"key":20,"text":110,"correct":26},{"key":24,"text":112,"correct":22},{"key":28,"text":114,"correct":26},{"key":31,"text":116,"correct":26},{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":28,"analysis":33},971964,"（）是指在规定的时间内，向防护区喷射设计规定用量的气体灭火剂，并使其均匀地充满整个防护区的气体灭火系统。",[129,130,131,132],{"key":20,"text":110,"correct":26},{"key":24,"text":112,"correct":26},{"key":28,"text":114,"correct":22},{"key":31,"text":116,"correct":26},{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":31,"analysis":33},971965,"（）是指在规定时间内向保护对象以设计喷射率直接喷射灭火剂，并持续一定时间的灭火系统。",[137,138,139,140],{"key":20,"text":110,"correct":26},{"key":24,"text":112,"correct":26},{"key":28,"text":114,"correct":26},{"key":31,"text":116,"correct":22},{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":31,"analysis":33},971966,"（）适用于扑救在灭火过程中不能封闭，或是能够封闭但不符合全淹没灭火系统要求的表面火灾。",[145,146,147,148],{"key":20,"text":110,"correct":26},{"key":24,"text":112,"correct":26},{"key":28,"text":114,"correct":26},{"key":31,"text":116,"correct":22},{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":24,"analysis":33},971967,"（）适用于防护区在位置上是单独的，离其他防护区较远不便于组合，或是防火区存在同时着火的可能性的情况。",[153,154,156,158],{"key":20,"text":110,"correct":26},{"key":24,"text":155,"correct":22},"单元独立灭火系统",{"key":28,"text":157,"correct":26},"组合分配灭火系统",{"key":31,"text":116,"correct":26},{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":28,"analysis":33},971968,"（）是指用一套灭火剂储存装置保护两个及两个以上防护区或保护对象的灭火系统。",[163,164,165,166],{"key":20,"text":110,"correct":26},{"key":24,"text":155,"correct":26},{"key":28,"text":157,"correct":22},{"key":31,"text":116,"correct":26},{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":28,"analysis":33},971969,"（）通过选择阀的控制，实现灭火剂的定向释放，具有减少灭火剂储量、节约建造成本、减少空间占用以及便于维护管理等优点。",[171,172,173,174],{"key":20,"text":110,"correct":26},{"key":24,"text":155,"correct":26},{"key":28,"text":157,"correct":22},{"key":31,"text":116,"correct":26},{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":28,"analysis":33},971970,"（）适用于多个不会同时着火的相邻防护区或保护对象。",[179,180,181,182],{"key":20,"text":110,"correct":26},{"key":24,"text":155,"correct":26},{"key":28,"text":157,"correct":22},{"key":31,"text":116,"correct":26},{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":20,"analysis":33},971971,"（）是指灭火剂瓶组中的灭火剂依靠自身压力进行输送的灭火系统。",[187,189,191,193],{"key":20,"text":188,"correct":22},"自压式气体灭火系统",{"key":24,"text":190,"correct":26},"内储压式气体灭火系统",{"key":28,"text":192,"correct":26},"外储压式气体灭火系统",{"key":31,"text":116,"correct":26},{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":31,"analysis":33},971972,"气体灭火系统延迟不大于（）发出灭火指令。",[198,200,202,204],{"key":20,"text":199,"correct":26},"3S",{"key":24,"text":201,"correct":26},"5S",{"key":28,"text":203,"correct":26},"10S",{"key":31,"text":205,"correct":22},"30S",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":20,"analysis":33},971973,"灭火控制器（盘）具有手动优先的功能，即便系统处于（）状态，（）仍然有效。",[210,212,214,216],{"key":20,"text":211,"correct":22},"自动控制手动控制",{"key":24,"text":213,"correct":26},"手动控制手动控制",{"key":28,"text":215,"correct":26},"手动控制自动控制",{"key":31,"text":217,"correct":26},"自动控制自动控制",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":31,"analysis":33},971974,"防护区应有保证人员在（）内疏散完毕的通道和出口。",[222,223,225,226],{"key":20,"text":203,"correct":26},{"key":24,"text":224,"correct":26},"60S",{"key":28,"text":201,"correct":26},{"key":31,"text":205,"correct":22},{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":20,"analysis":33},971975,"为防止防护区结构因火灾或内部压力增加而损坏，要求防护区围护结构及门窗的耐火极限均不宜低于（）。",[231,233,235,237],{"key":20,"text":232,"correct":22},"0．5h",{"key":24,"text":234,"correct":26},"1h",{"key":28,"text":236,"correct":26},"1．5h",{"key":31,"text":238,"correct":26},"3h",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":31,"analysis":33},971976,"为防止灭火剂流失，防护区的围护构件上不宜设置敞开孔洞；当必须设置敞开孔洞时，应设置能（）关闭装置。",[243,245,247,249],{"key":20,"text":244,"correct":26},"手动",{"key":24,"text":246,"correct":26},"自动",{"key":28,"text":248,"correct":26},"手动或自动",{"key":31,"text":250,"correct":22},"手动和自动",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":24,"analysis":33},971977,"喷放灭火剂前，防护区内除泄压口外的开口应能（）关闭。",[255,256,257,258],{"key":20,"text":244,"correct":26},{"key":24,"text":246,"correct":22},{"key":28,"text":248,"correct":26},{"key":31,"text":250,"correct":26},{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":20,"analysis":33},971978,"低倍数泡沫灭火系统发泡倍数为（）。",[263,265,267,269],{"key":20,"text":264,"correct":22},"小于20",{"key":24,"text":266,"correct":26},"21-200",{"key":28,"text":268,"correct":26},"201-1000",{"key":31,"text":270,"correct":26},"1000以上",{"id":272,"libraryId":5,"type":273,"typeLabel":274,"stem":275,"options":276,"answer":285,"analysis":33},971979,2,"多选题","火灾自动报警系统包括（）。",[277,279,281,283],{"key":20,"text":278,"correct":22},"火灾探测报警系统",{"key":24,"text":280,"correct":26},"火灾自动报警系统",{"key":28,"text":282,"correct":22},"消防联动控制系统",{"key":31,"text":284,"correct":26},"消防设施操作系统","AC",{"id":287,"libraryId":5,"type":273,"typeLabel":274,"stem":288,"options":289,"answer":298,"analysis":33},971980,"火灾自动报警系统的基本形式有（）。",[290,292,294,296],{"key":20,"text":291,"correct":22},"区域报警系统",{"key":24,"text":293,"correct":22},"集中报警系统",{"key":28,"text":295,"correct":22},"控制中心报警系统",{"key":31,"text":297,"correct":26},"集中区域兼容报警系统","ABC",{"id":300,"libraryId":5,"type":273,"typeLabel":274,"stem":301,"options":302,"answer":311,"analysis":33},971981,"消防联动控制系统的作用是控制及监视（）等相关消防设备，发生火灾时执行预设的消防功能。",[303,305,307,309],{"key":20,"text":304,"correct":22},"消防水泵．",{"key":24,"text":306,"correct":22},"排烟风机",{"key":28,"text":308,"correct":22},"消防电梯",{"key":31,"text":310,"correct":22},"防火卷帘","ABCD",{"id":313,"libraryId":5,"type":273,"typeLabel":274,"stem":314,"options":315,"answer":298,"analysis":33},971983,"以下哪些地方需要设置预作用系统（）。",[316,318,320,322],{"key":20,"text":317,"correct":22},"系统处于准工作状态时严禁误喷的场所",{"key":24,"text":319,"correct":22},"系统处于准工作状态时严禁管道充水的场所",{"key":28,"text":321,"correct":22},"用于替代干式系统的场所",{"key":31,"text":323,"correct":26},"灭火后必须及时停止喷水，要求减少不必要水渍损失的场所",{"id":325,"libraryId":5,"type":273,"typeLabel":274,"stem":326,"options":327,"answer":336,"analysis":33},971984,"以下哪种方式可以触发预作用系统（）。",[328,330,332,334],{"key":20,"text":329,"correct":22},"触发同一报警区域内两个及以上独立的感烟探测器",{"key":24,"text":331,"correct":22},"触发一个感烟探测器与一个手动报警按钮",{"key":28,"text":333,"correct":26},"触发两个感烟探测器",{"key":31,"text":335,"correct":26},"触发两个手动报警按钮","AB",{"id":338,"libraryId":5,"type":273,"typeLabel":274,"stem":339,"options":340,"answer":336,"analysis":33},971985,"水幕系统由开式喷头或水幕喷头、雨淋报警阀组或感温雨淋报警阀等组成，分为（）和（）两种。",[341,343,345,347],{"key":20,"text":342,"correct":22},"防火分隔水幕",{"key":24,"text":344,"correct":22},"防护冷却水幕",{"key":28,"text":346,"correct":26},"防护分隔水幕",{"key":31,"text":348,"correct":26},"防火冷却水幕",{"id":350,"libraryId":5,"type":273,"typeLabel":274,"stem":351,"options":352,"answer":311,"analysis":33},971986,"气体灭火系统按照使用的灭火剂不同，分为（）。",[353,354,355,356],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":22},{"key":28,"text":69,"correct":22},{"key":31,"text":65,"correct":22},{"id":358,"libraryId":5,"type":273,"typeLabel":274,"stem":359,"options":360,"answer":336,"analysis":33},971987,"按装配形式的不同，气体灭火系统分为（）。",[361,362,363,364],{"key":20,"text":110,"correct":22},{"key":24,"text":112,"correct":22},{"key":28,"text":114,"correct":26},{"key":31,"text":116,"correct":26},{"id":366,"libraryId":5,"type":273,"typeLabel":274,"stem":367,"options":368,"answer":373,"analysis":33},971988,"按应用方式的不同，气体灭火系统分为（）。",[369,370,371,372],{"key":20,"text":110,"correct":26},{"key":24,"text":112,"correct":26},{"key":28,"text":114,"correct":22},{"key":31,"text":116,"correct":22},"CD",{"id":375,"libraryId":5,"type":273,"typeLabel":274,"stem":376,"options":377,"answer":382,"analysis":33},971989,"按结构特点的不同，气体灭火系统分为（）。",[378,379,380,381],{"key":20,"text":110,"correct":26},{"key":24,"text":155,"correct":22},{"key":28,"text":157,"correct":22},{"key":31,"text":116,"correct":26},"BC",{"id":384,"libraryId":5,"type":273,"typeLabel":274,"stem":385,"options":386,"answer":298,"analysis":33},971990,"管网气体灭火系统有（）启动方式。",[387,389,391,393],{"key":20,"text":388,"correct":22},"自动控制",{"key":24,"text":390,"correct":22},"手动控制",{"key":28,"text":392,"correct":22},"机构应急",{"key":31,"text":394,"correct":26},"远程操作",{"id":396,"libraryId":5,"type":273,"typeLabel":274,"stem":397,"options":398,"answer":298,"analysis":33},971991,"泡沫灭火系统按照发泡倍数可以分为（）。",[399,401,403,405],{"key":20,"text":400,"correct":22},"低倍数泡沫灭火系统",{"key":24,"text":402,"correct":22},"中倍数泡沫灭火系统",{"key":28,"text":404,"correct":22},"高倍数泡沫灭火系统",{"key":31,"text":406,"correct":26},"超高倍数泡沫灭火系统",{"id":408,"libraryId":5,"type":273,"typeLabel":274,"stem":409,"options":410,"answer":298,"analysis":33},971992,"消防水源有（）三类。",[411,413,415,417],{"key":20,"text":412,"correct":22},"市政给水",{"key":24,"text":414,"correct":22},"消防水池",{"key":28,"text":416,"correct":22},"天然水源",{"key":31,"text":418,"correct":26},"消防水箱",{"id":420,"libraryId":5,"type":421,"typeLabel":422,"stem":423,"options":424,"answer":426,"analysis":33},971993,3,"判断题","火灾自动报警系统包括火灾探测报警系统和消防联动控制系统。（）",[425,427],{"key":20,"text":426,"correct":22},"正确",{"key":24,"text":428,"correct":26},"错误",{"id":430,"libraryId":5,"type":421,"typeLabel":422,"stem":431,"options":432,"answer":426,"analysis":33},971994,"火灾探测报警系统的作用是通过探测保护现场的火焰、热量和烟雾等相关参数发出报警信号，显示火灾发生的部位，发出声、光报警信号以通知相关人员进行疏散和实施火灾扑救。（）",[433,434],{"key":20,"text":426,"correct":22},{"key":24,"text":428,"correct":26},{"id":436,"libraryId":5,"type":421,"typeLabel":422,"stem":437,"options":438,"answer":426,"analysis":33},971995,"消防联动控制系统的作用是控制及监视消防水泵、排烟风机、消防电梯以及防火卷帘等相关消防设备，发生火灾时执行预设的消防功能。（）",[439,440],{"key":20,"text":426,"correct":22},{"key":24,"text":428,"correct":26},{"id":442,"libraryId":5,"type":421,"typeLabel":422,"stem":443,"options":444,"answer":428,"analysis":33},971996,"火灾自动报警系统的基本形式有区域报警系统、集中报警系统和区域集中兼容报警系统三种类型。（）",[445,446],{"key":20,"text":426,"correct":26},{"key":24,"text":428,"correct":22},{"id":448,"libraryId":5,"type":421,"typeLabel":422,"stem":449,"options":450,"answer":426,"analysis":33},971997,"区域报警系统是由区域火灾报警控制器和火灾探测器组成，功能简单的火灾自动报警系统称为区域报警系统。（）",[451,452],{"key":20,"text":426,"correct":22},{"key":24,"text":428,"correct":26},{"id":454,"libraryId":5,"type":421,"typeLabel":422,"stem":455,"options":456,"answer":426,"analysis":33},971998,"消防设施是指专门用于火灾预防、火灾报警、灭火以及发生火灾时人员疏散的火灾自动报警系统、自动灭火系统、消火栓系统、防排烟系统以及应急广播和应急照明、防火分隔设施、安全疏散设施等固定消防系统和设备。（）",[457,458],{"key":20,"text":426,"correct":22},{"key":24,"text":428,"correct":26},{"id":460,"libraryId":5,"type":421,"typeLabel":422,"stem":461,"options":462,"answer":426,"analysis":33},971999,"自动喷水灭火系统是由洒水喷头、报警阀组、水流报警装置（水流指示器或压力开关）等组件以及管道、供水设施等组成，能在发生火灾时喷水的自动灭火系统。（）",[463,464],{"key":20,"text":426,"correct":22},{"key":24,"text":428,"correct":26},{"id":466,"libraryId":5,"type":421,"typeLabel":422,"stem":467,"options":468,"answer":428,"analysis":33},972000,"气体灭火系统是以气体为主要灭火介质的灭火系统，通过这些气体在防护区内或保护对象周围的局部区域建立起灭火浓度实现灭火。（）",[469,470],{"key":20,"text":426,"correct":26},{"key":24,"text":428,"correct":22},{"id":472,"libraryId":5,"type":421,"typeLabel":422,"stem":473,"options":474,"answer":428,"analysis":33},972001,"集中报警系统由区域火灾报警控制器和火灾探测器组成，功能简单的火灾自动报警系统称为区域报警系统。（）",[475,476],{"key":20,"text":426,"correct":26},{"key":24,"text":428,"correct":22},{"id":478,"libraryId":5,"type":421,"typeLabel":422,"stem":479,"options":480,"answer":426,"analysis":33},972002,"触发器件主要有火灾探测器和手动火灾报警按钮，其作用是自动或手动产生火灾报警信号。（）",[481,482],{"key":20,"text":426,"correct":22},{"key":24,"text":428,"correct":26},{"id":484,"libraryId":5,"type":421,"typeLabel":422,"stem":485,"options":486,"answer":426,"analysis":33},972003,"手动火灾报警按钮可手动方式产生火灾报警信号。（）",[487,488],{"key":20,"text":426,"correct":22},{"key":24,"text":428,"correct":26},{"id":490,"libraryId":5,"type":421,"typeLabel":422,"stem":491,"options":492,"answer":426,"analysis":33},972004,"火灾报警控制器的作用是接收、显示和传递火灾报警信号，记录报警的具体部位及时间，监视探测器及系统自身的工作状态，并执行相应辅助控制等任务。（）",[493,494],{"key":20,"text":426,"correct":22},{"key":24,"text":428,"correct":26},[496,499,502,505,508,511],{"id":15,"name":497,"category":7,"favorite":498},"领导干部任职前廉政法规知识测试题",92,{"id":500,"name":501,"category":7,"favorite":15},595,"建筑结构与设备",{"id":503,"name":504,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":506,"name":507,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":509,"name":510,"category":7,"favorite":8},534,"BIM工程师",{"id":512,"name":510,"category":7,"favorite":8},535]