[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-971368":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},971368,703,2,"多选题","某10层住宅建筑层高为30m。外保温体系与基层墙体无空腔，对该住宅外墙进行保温设计，选用的保温方式和材料中，符合规范要求的有（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","保温材料采用燃烧性能为B1级的胶粉聚苯颗粒保温浆料",false,{"key":16,"text":17,"correct":18},"B","保温材料采用燃烧性能为A级的泡沬玻璃板",true,{"key":20,"text":21,"correct":18},"C","保温材料采用燃烧性能为A级水泥发泡保温板",{"key":23,"text":24,"correct":18},"D","保温材料采用燃烧性能为B1级的胶粉聚苯颗粒保温浆料，每层设置防火隔离带",{"key":26,"text":27,"correct":14},"E","保温材料采用燃烧性能为B2级的聚苯乙烯泡沫塑料，每层设置防火隔离带","BCD","住宅建筑高度为30m，对于住宅建筑，与基层墙体、装饰层之间无空腔的建筑外墙外保温系统，其保温材料应符合下列规定：建筑高度大于27m，但不大于100m时，保温材料的燃烧性能不应低于B1级。当建筑的屋面和外墙外保温系统均采用B1、B2级保温材料时，每层设置防火隔离带；建筑外墙上门、窗的耐火完整性不应低于0.50h。",{"id":6,"name":31,"category":32,"favorite":33},"基础知识（通用）","建筑工程",0]