[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-971338":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},971338,703,1,"单选题","下列关于建筑外墙外保温材料设计方案不符合规范规范规定的是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","建筑高度50m的住宅建筑，保温层与基层墙体、装饰层之间无空腔，选用燃烧性能为B1级的外保温材料",false,{"key":16,"text":17,"correct":14},"B","建筑高度40m的办公楼，保温层与基层墙体、装饰层之间无空腔，选用燃烧性能为B1级的外保温材料",{"key":19,"text":20,"correct":21},"C","建筑高度20m的展览建筑，保温层与基层墙体、装饰层之间无空腔，选用燃烧性能为B1级的外保温材料",true,{"key":23,"text":24,"correct":14},"D","建筑高度24m的办公建筑，保温层与基层墙体、装饰层之间有空腔，选用燃烧性能为B1级的外保温材料","除设置人员密集场所的建筑外，与基层墙体、装饰层之间有空腔的建筑外墙外保温系统，其保温材料应符合下列规定：建筑高度大于24m时，保温材料的燃烧性能应为A级。建筑高度不大于24m时，保温材料的燃烧性能不应低于B1级。展览建筑属于人员密集场所，其外保温应采用燃烧性能为A级的保温材料。选项C错误。",{"id":6,"name":27,"category":28,"favorite":29},"基础知识（通用）","建筑工程",0]