[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-971321":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},971321,703,2,"多选题","下列应设置封闭楼梯间的有（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","多层医疗建筑",true,{"key":16,"text":17,"correct":18},"B","建筑高度35m的二类高层建筑",false,{"key":20,"text":21,"correct":14},"C","高层建筑的裙房",{"key":23,"text":24,"correct":14},"D","建筑高度25m的住宅楼",{"key":26,"text":27,"correct":14},"E","建筑高度20m的办公楼","ACDE","封闭楼梯间是指在楼梯间入口设置门，以防止火灾的烟气和热气进入的楼梯间。封闭楼梯间有墙和门与走道分隔，安全性较高，在多层公共建筑、医疗建筑，旅馆及类似使用功能的建筑，设置歌舞娱乐放映游艺场所的建筑，商店、图书馆、展览建筑、会议中心及类似使用功能的建筑和6层以上的其他建筑，其疏散楼梯均应设置为封闭楼梯间。高层建筑的裙房和建筑高度不超过32m的二类高层建筑，建筑高度大于21m且不大于33m的住宅建筑，高层厂房和甲、乙、丙类多层厂房，其疏散楼梯间也应采用封闭楼梯间。",{"id":6,"name":31,"category":32,"favorite":33},"基础知识（通用）","建筑工程",0]