[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-970077":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},970077,703,2,"多选题","防火间距不足时应采取的措施有（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","提高建筑的耐火等级",true,{"key":16,"text":17,"correct":14},"B","提高部分构件的耐火性能和燃烧性能",{"key":19,"text":20,"correct":14},"C","减小相邻建筑的开口面积",{"key":22,"text":23,"correct":24},"D","提高建筑的层数",false,{"key":26,"text":27,"correct":14},"E","设置独立的室外防火墙","ABCE","防火间距不足时应采取的措施防火间距由于场地等原因，难以满足国家规范的要求时，可根据建筑的实际情况采取以下措施：1）改变建筑的生产和使用性质，尽量降低建筑的火灾危险性；改变房屋部分结构的耐火性能，提高建筑的耐火等级。2）调整生产厂房的部分工艺流程，限制库房内储存物品的数量，提高部分构件的耐火性能和燃烧性能。3）将建筑的普通外墙改造为防火墙或减小相邻建筑的开口面积。4）拆除部分耐火等级低、占地面积小、存在价值低且与新建筑相邻的原有陈旧建筑。5）设置独立的室外防火墙。",{"id":6,"name":31,"category":32,"favorite":33},"基础知识（通用）","建筑工程",0]