[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":592},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,8,50,2716,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,188,200,212,224,236,248,259,271,283,295,305,317,329,341,353,365,377,386,397,407,416,428,438,447,459,471,483,493,505,517,529,541,553,565,574,583],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},964563,1,"单选题","预作用系统是准工作状态时配水管道内不充水，由火灾自动报警系统自动开启雨淋报警阀后，系统端由干式转换为（ ）系统的（ ）系统。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","干式；开式",false,{"key":24,"text":25,"correct":22},"B","干式；闭式",{"key":27,"text":28,"correct":22},"C","湿式；开式",{"key":30,"text":31,"correct":32},"D","湿式；闭式",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},964564,"自动喷水灭火系统喷头验收检查时，各种不同规格的喷头的备用品数量不少于安装喷头总数的（ ）%，且每种备用喷头不少于（ ）个。",[38,40,42,44],{"key":20,"text":39,"correct":32},"l，10",{"key":24,"text":41,"correct":22},"5，10",{"key":27,"text":43,"correct":22},"l，20",{"key":30,"text":45,"correct":22},"5，20",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},964565,"水力警铃和报警阀的连接，釆用热镀锌钢管，当镀锌钢管的公称直径为20mm时，其长度不宜大于（ ）m。",[50,52,54,56],{"key":20,"text":51,"correct":22},"10",{"key":24,"text":53,"correct":22},"15",{"key":27,"text":55,"correct":32},"20",{"key":30,"text":57,"correct":22},"30",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},964566,"易熔元件头轭臂色标为红色的对应公称动作温度是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"57-77O",{"key":24,"text":65,"correct":22},"80-107",{"key":27,"text":67,"correct":32},"163-191",{"key":30,"text":69,"correct":22},"204-246",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},964567,"雨淋报警阀启动装置釆用的液动或气动系统由充水或充气的传动管、（ ）、压力开关等组成。",[74,76,78,80],{"key":20,"text":75,"correct":22},"电磁阀",{"key":24,"text":77,"correct":22},"开式喷头",{"key":27,"text":79,"correct":32},"闭式喷头",{"key":30,"text":81,"correct":22},"火灾探测器",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},964568,"预作用系统当需利用有压气体检测首严密性时，配水管道内气压值宜为（ ）MPa。充气前应先注入少量的清水封闭预作用阀口，以防漏气；并当管道充水时，应停止气泵运行。",[86,88,90,92],{"key":20,"text":87,"correct":22},"0.025-0.035",{"key":24,"text":89,"correct":32},"0.035-0.05",{"key":27,"text":91,"correct":22},"0.035-0.08",{"key":30,"text":93,"correct":22},"0.05-1.0",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},964569,"干式消火栓系统允许的最大充水时间不宜大于（ ）min。",[98,100,102,104],{"key":20,"text":99,"correct":22},"1",{"key":24,"text":101,"correct":22},"3",{"key":27,"text":103,"correct":32},"5",{"key":30,"text":105,"correct":22},"7",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":27,"analysis":33},964570,"室外阀门井中，进水管上的控制阀门应（ ）检查一次，核实其处于全开启状态",[110,112,114,116],{"key":20,"text":111,"correct":22},"每天",{"key":24,"text":113,"correct":22},"每月",{"key":27,"text":115,"correct":32},"每季度",{"key":30,"text":117,"correct":22},"每年",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},964571,"灭火后必须及时停止喷水的场所，应釆用（ ）系统。",[122,124,126,128],{"key":20,"text":123,"correct":22},"雨淋",{"key":24,"text":125,"correct":32},"重复启闭预作用",{"key":27,"text":127,"correct":22},"湿式",{"key":30,"text":129,"correct":22},"干湿式",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},964572,"水力警铃的设置位置应正确，测试时，水力铃喷嘴处的压力不小于0.05MP A，且距水力警铃（ ）m远处警铃声声墙不应小于（ ）dB。",[134,136,138,140],{"key":20,"text":135,"correct":22},"l，65",{"key":24,"text":137,"correct":22},"2，70",{"key":27,"text":139,"correct":32},"3，70",{"key":30,"text":141,"correct":22},"3，75",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":30,"analysis":33},964573,"水流指示器是自动喷水灭火系统中将水流信号转换成（ ）信号的一种报警装置。",[146,148,150,152],{"key":20,"text":147,"correct":22},"光",{"key":24,"text":149,"correct":22},"磁",{"key":27,"text":151,"correct":22},"热",{"key":30,"text":153,"correct":32},"电",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},964574,"信号阀应安装在水流指示器（ ）的管道上。",[158,160,162,164],{"key":20,"text":159,"correct":32},"前",{"key":24,"text":161,"correct":22},"后",{"key":27,"text":163,"correct":22},"前或后",{"key":30,"text":165,"correct":22},"前和后",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":27,"analysis":33},964575,"在预作用系统中，报警阀是通过（ ）开启和关闭管网的水流，传递控制信号至控制系统。",[170,172,174,176],{"key":20,"text":171,"correct":22},"自动",{"key":24,"text":173,"correct":22},"手动",{"key":27,"text":175,"correct":32},"自动和手动",{"key":30,"text":177,"correct":22},"专用泵",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},964576,"预作用系统雨淋阀组后的管道若需充气，其安装应按（ ）报警阀组有关要求进行。",[182,183,185,186],{"key":20,"text":127,"correct":22},{"key":24,"text":184,"correct":32},"干式",{"key":27,"text":129,"correct":22},{"key":30,"text":187,"correct":22},"预作用",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":24,"analysis":33},964577,"水流指示器应使电器元件部位（ ）安装在水平管道上侧。",[192,194,196,198],{"key":20,"text":193,"correct":22},"平行",{"key":24,"text":195,"correct":32},"竖直",{"key":27,"text":197,"correct":22},"交错",{"key":30,"text":199,"correct":22},"任意",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":24,"analysis":33},964578,"洒水喷头属于（ ）类产品。",[204,206,208,210],{"key":20,"text":205,"correct":22},"型式认可",{"key":24,"text":207,"correct":32},"强制认证",{"key":27,"text":209,"correct":22},"强制检验",{"key":30,"text":211,"correct":22},"公告",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":20,"analysis":33},964579,"ZSFZ湿式报警阀为盖板型报警阀，主要由阀体、座圈和（ ）三部分组成。",[216,218,220,222],{"key":20,"text":217,"correct":32},"阀瓣",{"key":24,"text":219,"correct":22},"压力表",{"key":27,"text":221,"correct":22},"过滤器",{"key":30,"text":223,"correct":22},"平衡阀",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":27,"analysis":33},964580,"黄色玻璃球洒水喷头的动作温度是（ ）℃。",[228,230,232,234],{"key":20,"text":229,"correct":22},"57",{"key":24,"text":231,"correct":22},"68",{"key":27,"text":233,"correct":32},"79",{"key":30,"text":235,"correct":22},"93",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":20,"analysis":33},964581,"湿式自动喷水灭火系统启动消防泵的方式首选应为（ ）。",[240,242,244,246],{"key":20,"text":241,"correct":32},"自动启动",{"key":24,"text":243,"correct":22},"消防控制室远程启动",{"key":27,"text":245,"correct":22},"水泵房手动启动",{"key":30,"text":247,"correct":22},"任选",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":27,"analysis":33},964582,"红色玻璃球洒水喷头的动作温度是（ ）℃。",[252,254,256,257],{"key":20,"text":253,"correct":22},"76",{"key":24,"text":255,"correct":22},"72",{"key":27,"text":231,"correct":32},{"key":30,"text":258,"correct":22},"63",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":24,"analysis":33},964583,"雨淋阀组的电磁阀，其入口应设（ ）并联设置雨淋阀组的雨淋系统，其雨淋阀控制腔的入口应设（ ）。",[263,265,267,269],{"key":20,"text":264,"correct":22},"止回阀；过滤器",{"key":24,"text":266,"correct":32},"过滤器；止回阀",{"key":27,"text":268,"correct":22},"过滤器；过滤器",{"key":30,"text":270,"correct":22},"止回阀；止回阀",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":20,"analysis":33},964584,"干式喷水灭火系统由（ ）组成。",[275,277,279,281],{"key":20,"text":276,"correct":32},"闭式喷头、管道、干式报警阀、压力气源、排气设备、供水设备",{"key":24,"text":278,"correct":22},"开式喷头、管道、干式报警阀、压力气源、排气设备、供水设备",{"key":27,"text":280,"correct":22},"闭式喷头、管道、干式报警阀、供水设备",{"key":30,"text":282,"correct":22},"开式喷头、管道、干式报警阀、供水设备",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":24,"analysis":33},964585,"报警阀组安装时，报警阀阀体底边距室内地面高度为（ ）m；侧边与墙的距离不小于（ ）m。",[287,289,291,293],{"key":20,"text":288,"correct":22},"1.0，0.5",{"key":24,"text":290,"correct":32},"1.2，0.5",{"key":27,"text":292,"correct":22},"1.0，0.8",{"key":30,"text":294,"correct":22},"1.2，0.8",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":30,"analysis":33},964586,"发生火灾时，雨淋系统中的雨淋阀由（ ）发出信号开启。",[299,300,301,303],{"key":20,"text":79,"correct":22},{"key":24,"text":77,"correct":22},{"key":27,"text":302,"correct":22},"水流指示器",{"key":30,"text":304,"correct":32},"火灾报警控制器",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":24,"analysis":33},964587,"报警阀应逐个进行渗漏试验，试验压力及试验时间应为（ ）。",[309,311,313,315],{"key":20,"text":310,"correct":22},"试验压力为额定工作压力的1.5倍，试验时间不应小于5min",{"key":24,"text":312,"correct":32},"试验压力为额定工作压力的2倍，试验时间不应小于5min",{"key":27,"text":314,"correct":22},"试验压力为额定工作压力的1.5倍，试验时间不应小于l0min",{"key":30,"text":316,"correct":22},"试验压力为额定工作压力的2倍，试验时间不应小于l0min",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":27,"analysis":33},964588,"以下常见喷头，规格与型号不相对应的是（ ）。",[321,323,325,327],{"key":20,"text":322,"correct":22},"直立型喷头，ZSTZ",{"key":24,"text":324,"correct":22},"下垂型喷头，ZST",{"key":27,"text":326,"correct":32},"干式喷头，ZSTB",{"key":30,"text":328,"correct":22},"嵌入式喷头，ZSTDR",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":20,"analysis":33},964589,"湿式系统、干式系统的喷头动作后，应由（ ）直接连锁自动启动供水泵。",[333,335,337,339],{"key":20,"text":334,"correct":32},"压力开关",{"key":24,"text":336,"correct":22},"消防控制室",{"key":27,"text":338,"correct":22},"报警阀",{"key":30,"text":340,"correct":22},"控制柜",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":30,"analysis":33},964590,"下列对自动喷水灭火系统的节流管表述不正确的是（ ）。",[345,347,349,351],{"key":20,"text":346,"correct":22},"直径宜按上游管段直径的1\u002F2确定",{"key":24,"text":348,"correct":22},"长度不宜小于lm",{"key":27,"text":350,"correct":22},"节流管内水的平均流速不应大于20m\u002Fs",{"key":30,"text":352,"correct":32},"节流管内压力不宜大于0.02MPA",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":24,"analysis":33},964591,"闭式喷头的公称动作温度为79℃时，其色标应为（ ）。",[357,359,361,363],{"key":20,"text":358,"correct":22},"橙色",{"key":24,"text":360,"correct":32},"红色",{"key":27,"text":362,"correct":22},"黄色",{"key":30,"text":364,"correct":22},"绿色",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":27,"analysis":33},964592,"下列哪项属于闭式喷头（ ）。",[369,371,373,375],{"key":20,"text":370,"correct":22},"雨淋喷头",{"key":24,"text":372,"correct":22},"水幕喷头",{"key":27,"text":374,"correct":32},"玻璃球喷头",{"key":30,"text":376,"correct":22},"喷雾式喷头",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":24,"analysis":33},964593,"预作用自动喷水系统，在准工作状态下，配水管道内不充水，由火灾报警自动开启雨淋阀后，转换为（ ）系统。",[381,382,383,384],{"key":20,"text":184,"correct":22},{"key":24,"text":127,"correct":32},{"key":27,"text":187,"correct":22},{"key":30,"text":385,"correct":22},"冰幕",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":27,"analysis":33},964594,"当水流指示器入口前设置控制阀时，立釆用（ ）。",[390,391,393,395],{"key":20,"text":75,"correct":22},{"key":24,"text":392,"correct":22},"止回阀",{"key":27,"text":394,"correct":32},"信号阀",{"key":30,"text":396,"correct":22},"法兰闸阀",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":24,"analysis":33},964595,"快速排气阀入口前的电动阀，应在启动供水泵（ ）开启。",[401,402,404,405],{"key":20,"text":159,"correct":22},{"key":24,"text":403,"correct":32},"同时",{"key":27,"text":161,"correct":22},{"key":30,"text":406,"correct":22},"视情况而定",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":30,"analysis":33},964596,"每个报警阀组控制的最不利点喷头处，应设末端试水装置，其他防火分区、楼层均应设直径为（ ）mm的试水阀。",[411,412,413,414],{"key":20,"text":53,"correct":22},{"key":24,"text":51,"correct":22},{"key":27,"text":55,"correct":22},{"key":30,"text":415,"correct":32},"25",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":30,"analysis":33},964597,"湿式报警阀调试时，当进口水压大于（ ）MPa，放水流量大于（ ）L\u002FS时，报警阀应及时启动。",[420,422,424,426],{"key":20,"text":421,"correct":22},"0.28；1.5",{"key":24,"text":423,"correct":22},"0.14；1.5",{"key":27,"text":425,"correct":22},"0.28；1",{"key":30,"text":427,"correct":32},"0.14；1",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":27,"analysis":33},964598,"雨淋系统和防火分隔水幕，其水流报警装置宜釆用（ ）。",[432,434,436,437],{"key":20,"text":433,"correct":22},"警铃",{"key":24,"text":435,"correct":22},"手报",{"key":27,"text":334,"correct":32},{"key":30,"text":302,"correct":22},{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":27,"analysis":33},964599,"（ ）应对系统的放水试验阀进行一次放水试验，检查系统启动、报警及出水情况是否正常。",[442,444,445,446],{"key":20,"text":443,"correct":22},"每周",{"key":24,"text":113,"correct":22},{"key":27,"text":115,"correct":32},{"key":30,"text":117,"correct":22},{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":27,"analysis":33},964600,"水流指示器的安装应在（ ）后进行。",[451,453,455,457],{"key":20,"text":452,"correct":22},"埋地管道安装完毕",{"key":24,"text":454,"correct":22},"系统调试",{"key":27,"text":456,"correct":32},"管道试压、冲洗合格",{"key":30,"text":458,"correct":22},"水压强度试验、气压严密性试验完成",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":24,"analysis":33},964601,"预作用系统雨淋阀组后的管道若需充气，其安装应按（ ）有关要求进行。",[463,465,467,469],{"key":20,"text":464,"correct":22},"湿式报警阀组",{"key":24,"text":466,"correct":32},"干式报警阀组",{"key":27,"text":468,"correct":22},"预作用报警阀组",{"key":30,"text":470,"correct":22},"重复启闭预作用报警阀组",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":20,"analysis":33},964602,"报警阀组距室内地面安装高度宜为（ ）m。",[475,477,479,481],{"key":20,"text":476,"correct":32},"1.2",{"key":24,"text":478,"correct":22},"1.8",{"key":27,"text":480,"correct":22},"0.7",{"key":30,"text":482,"correct":22},"0.5",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":30,"analysis":33},964603,"发生火灾时，湿式系统由闭式喷头探测火灾，（ ）报告起火区域。",[487,488,490,491],{"key":20,"text":334,"correct":22},{"key":24,"text":489,"correct":22},"信号反馈装置",{"key":27,"text":394,"correct":22},{"key":30,"text":492,"correct":32},"冰流指示器",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":30,"analysis":33},964604,"水系统测试时水力警铃不能正常启动工作的原因不包括下列哪项（ ）。",[497,499,501,503],{"key":20,"text":498,"correct":22},"消防用水中的杂质堵塞了报警管道上过滤器的滤网",{"key":24,"text":500,"correct":22},"水力警铃进水口处喷嘴被堵塞",{"key":27,"text":502,"correct":22},"水力警铃铃锤卡死",{"key":30,"text":504,"correct":32},"水力警铃距离湿式报警阀的安装距离为15m",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":30,"analysis":33},964605,"雨淋阀组自动滴水阀漏水的原因不包括下列哪一项（ ）。",[509,511,513,515],{"key":20,"text":510,"correct":22},"产品存在质量问题",{"key":24,"text":512,"correct":22},"安装调试或者平时定期试验、实施灭火后，没有将系统侧管内的余水排尽。",{"key":27,"text":514,"correct":22},"雨淋报警阀隔膜球面中线密封处因施工遗留的杂物、不干净消防用水中的杂质等导致球状密封面不能完全密封。",{"key":30,"text":516,"correct":32},"雨淋阀开启后未及时复位。",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":24,"analysis":33},964606,"排烟风管的外观应请洁、完整无裂缝或变形，与可燃物保持不小于（ ）mm的距离。",[521,523,525,527],{"key":20,"text":522,"correct":22},"100",{"key":24,"text":524,"correct":32},"150",{"key":27,"text":526,"correct":22},"200",{"key":30,"text":528,"correct":22},"250",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":30,"analysis":33},964607,"机械加压送风系统中，（ ）—般安装在楼梯前室或楼梯与消防电梯合用前室内。",[533,535,537,539],{"key":20,"text":534,"correct":22},"自垂百叶式风口",{"key":24,"text":536,"correct":22},"普通固定百叶式常开风口",{"key":27,"text":538,"correct":22},"防雨百叶式常开风口",{"key":30,"text":540,"correct":32},"多叶常闭风口",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":24,"analysis":33},964608,"报警阀安装顺序描述正确的是（ ）。",[545,547,549,551],{"key":20,"text":546,"correct":22},"水源控制阀-报警阀辅助管道-报警阀",{"key":24,"text":548,"correct":32},"水源控制阀-报警阀-报警阀辅助管道",{"key":27,"text":550,"correct":22},"报警阀-水源控制阀-报警阀辅助管道",{"key":30,"text":552,"correct":22},"报警阀-报警阀辅助管道-水源控制阀",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":20,"analysis":33},964609,"装设通透性吊项的场所，喷头应布置在（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":32},"项板下",{"key":24,"text":560,"correct":22},"吊项下",{"key":27,"text":562,"correct":22},"吊项下和吊项内",{"key":30,"text":564,"correct":22},"无要求",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":27,"analysis":33},964610,"下列哪项的引出线不需要用防水套管锁定（ ）。",[569,570,571,573],{"key":20,"text":334,"correct":22},{"key":24,"text":394,"correct":22},{"key":27,"text":572,"correct":32},"试水阀",{"key":30,"text":302,"correct":22},{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":24,"analysis":33},964611,"报警阀开启后，水流需经（ ）s左右充满延迟器后方可冲打水力警铃。",[578,580,581,582],{"key":20,"text":579,"correct":22},"40",{"key":24,"text":57,"correct":32},{"key":27,"text":55,"correct":22},{"key":30,"text":51,"correct":22},{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":30,"analysis":33},964612,"雨淋阀组应（ ）检查一次密封件和阀座，请除污物。",[587,588,589,591],{"key":20,"text":113,"correct":22},{"key":24,"text":115,"correct":22},{"key":27,"text":590,"correct":22},"每半年",{"key":30,"text":117,"correct":32},[593,596,599,602,605,608],{"id":15,"name":594,"category":7,"favorite":595},"领导干部任职前廉政法规知识测试题",92,{"id":597,"name":598,"category":7,"favorite":15},595,"建筑结构与设备",{"id":600,"name":601,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":603,"name":604,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":606,"name":607,"category":7,"favorite":8},534,"BIM工程师",{"id":609,"name":607,"category":7,"favorite":8},535]