[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":590},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,7,50,2716,[13,34,46,54,66,78,88,100,112,124,136,148,160,172,184,196,208,220,232,244,256,268,280,292,304,316,328,339,351,363,371,379,390,398,406,418,426,438,450,462,474,486,498,510,522,534,546,558,570,578],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},964513,1,"单选题","在总线设备上使用的十进制手动拨码开关的说法不正确的是：（ ）",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","一般选用两个或三个手动拨码开关",false,{"key":24,"text":25,"correct":22},"B","最末位开关代表个位，数字范围：0-9；",{"key":27,"text":28,"correct":29},"C","最末位开关代表百位，数字范围",true,{"key":31,"text":32,"correct":22},"D","第二位开关代表十位，数字范围：0-9；","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},964514,"早期火灾自动报警系统的总线设备编码一般都釆用（ ）方式。",[38,40,42,44],{"key":20,"text":39,"correct":22},"电动拨码开关",{"key":24,"text":41,"correct":29},"手动拨码开关",{"key":27,"text":43,"correct":22},"电子编码",{"key":31,"text":45,"correct":22},"控制器自动分配",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},964515,"（ ）是目前最常用的编码方式。",[50,51,52,53],{"key":20,"text":39,"correct":22},{"key":24,"text":41,"correct":22},{"key":27,"text":43,"correct":29},{"key":31,"text":45,"correct":22},{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":24,"analysis":33},964516,"火灾报警控制器在自动联动状态下，对信息特征描述不正确的一项是（ ）。",[58,60,62,64],{"key":20,"text":59,"correct":22},"启动灯亮",{"key":24,"text":61,"correct":29},"液晶显示启动设备参数和部位",{"key":27,"text":63,"correct":22},"记录启动时间",{"key":31,"text":65,"correct":22},"记录启动设备总数",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":24,"analysis":33},964517,"柴油机消防泵控制柜的基本要求不包括：（ ）。",[70,72,74,76],{"key":20,"text":71,"correct":22},"具有显示柴油机的运行状态和启动成功的信号指示",{"key":24,"text":73,"correct":29},"管网压力检测功能，可根据说明书设置启动压力点",{"key":27,"text":75,"correct":22},"压力记录，故障\u002F报警信息记录",{"key":31,"text":77,"correct":22},"运行、故障\u002F报警反馈输出信号",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":20,"analysis":33},964518,"下面哪项不是柴油机消防泵控制柜的基本要求？（ ）",[82,84,86,87],{"key":20,"text":83,"correct":29},"控制柜具有可见且能指示控制柜处于手动控制状态的开关",{"key":24,"text":85,"correct":22},"控制柜具有可接收远程启动信号和就地启动按钮启动消防泵的功能",{"key":27,"text":75,"correct":22},{"key":31,"text":77,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":31,"analysis":33},964519,"柴油机消防泵控制柜应对（ ）的运行、故障\u002F报警不反馈输出信号。",[92,94,96,98],{"key":20,"text":93,"correct":22},"低油压",{"key":24,"text":95,"correct":22},"发动机高温",{"key":27,"text":97,"correct":22},"发动机超速",{"key":31,"text":99,"correct":29},"柴油机油温低",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":31,"analysis":33},964520,"（ ）的运行、故障\u002F报警柴油机消防泵控制柜不会反馈输出信号。",[104,106,108,110],{"key":20,"text":105,"correct":22},"柴油机消防泵控制柜启动失败",{"key":24,"text":107,"correct":22},"润滑油压低",{"key":27,"text":109,"correct":22},"水温高",{"key":31,"text":111,"correct":29},"高油压",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":31,"analysis":33},964521,"柴油机水泵接到（ ），不会自动启动。",[116,118,120,122],{"key":20,"text":117,"correct":22},"火警信号",{"key":24,"text":119,"correct":22},"电动消防泵启动失败信号",{"key":27,"text":121,"correct":22},"消防水管网的压力低信号",{"key":31,"text":123,"correct":29},"电动消防泵油温高信号",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":31,"analysis":33},964522,"柴油机消防泵自动启动方式不包括（ ）。",[128,130,132,134],{"key":20,"text":129,"correct":22},"电启动",{"key":24,"text":131,"correct":22},"液压启动",{"key":27,"text":133,"correct":22},"压缩空气启动",{"key":31,"text":135,"correct":29},"火警信号启动",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":27,"analysis":33},964523,"柴油机消防泵组手动启动式不包括（ ）。",[140,142,144,146],{"key":20,"text":141,"correct":22},"控制柜上的手动启动",{"key":24,"text":143,"correct":22},"柴油机仪表箱上的手动启动",{"key":27,"text":145,"correct":29},"传动装置上的手动启动",{"key":31,"text":147,"correct":22},"柴油机上的手动启动",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":20,"analysis":33},964524,"在火灾等紧急情况下，当消防水泵控制柜的控制线路发生故障而供电正常时，为保证及时供水，操作设置在消防水泵控制柜上的强制机械应急手柄，直接使主回路交流接触器吸合，（ ）启动消防水泵。",[152,154,156,158],{"key":20,"text":153,"correct":29},"全压",{"key":24,"text":155,"correct":22},"半压",{"key":27,"text":157,"correct":22},"自动",{"key":31,"text":159,"correct":22},"手动",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":20,"analysis":33},964525,"下面关于机械应急启动装置的描述不正确的是（ ）。",[164,166,168,170],{"key":20,"text":165,"correct":29},"高压机械应急启动装置所需的电源是6000V",{"key":24,"text":167,"correct":22},"机械应急启动装置必须通过消防水泵控制柜的接触器实现",{"key":27,"text":169,"correct":22},"低压机械应急启动装置所需的电源是380V",{"key":31,"text":171,"correct":22},"高压机械应急启动装置由弹簧蓄能组成",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":20,"analysis":33},964526,"消防水泵机械应急启动装置的接触器单元内不包括（ ）。",[176,178,180,182],{"key":20,"text":177,"correct":29},"电动装置",{"key":24,"text":179,"correct":22},"性部件",{"key":27,"text":181,"correct":22},"动触头",{"key":31,"text":183,"correct":22},"静触头",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":31,"analysis":33},964527,"下面哪项不是拉锁型机械运动单元的工作原理：（ ）。",[188,190,192,194],{"key":20,"text":189,"correct":22},"人工向手柄施加作用力",{"key":24,"text":191,"correct":22},"该作用力通过拉索传递给运动部件，",{"key":27,"text":193,"correct":22},"运动部件带动机械臂运动，使接触器的每一相动触头都能平衡可靠地",{"key":31,"text":195,"correct":29},"同时接通动触头，可有效地防止缺相接通产生的有害电弧",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":27,"analysis":33},964528,"拉锁型机械运动单元不包括（ ）。",[200,202,204,206],{"key":20,"text":201,"correct":22},"机械臂",{"key":24,"text":203,"correct":22},"运动部件",{"key":27,"text":205,"correct":29},"接触器",{"key":31,"text":207,"correct":22},"手柄",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":24,"analysis":33},964529,"消防水泵应急启动装置的工作原理不正确的是：（ ）。",[212,214,216,218],{"key":20,"text":213,"correct":22},"釆用机械方式使接触器闭合，接通电路源",{"key":24,"text":215,"correct":29},"釆用人工方式使接触器闭合，接通电路源",{"key":27,"text":217,"correct":22},"不应借助或依赖任何电气控制回路、电磁装置或其他类似的等效装置。",{"key":31,"text":219,"correct":22},"水泵电动机直接全压启动",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":20,"analysis":33},964530,"燃气轮机组的空气使用量比柴油机组大（ ）倍。",[224,226,228,230],{"key":20,"text":225,"correct":29},"2.5-4",{"key":24,"text":227,"correct":22},"2-4",{"key":27,"text":229,"correct":22},"1.5-3",{"key":31,"text":231,"correct":22},"2-3",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":31,"analysis":33},964531,"低压二氧化碳气体灭火系统动作时总控阀和区域释放阀的动作顺序为（ ）。",[236,238,240,242],{"key":20,"text":237,"correct":22},"开启时先区域释放阀后总控阀，关闭时同时动作",{"key":24,"text":239,"correct":22},"开启时先总控阀后区域释放阀，关闭时先总控阀后区域释放阀",{"key":27,"text":241,"correct":22},"开启时先区域释放阀后总控阀，关闭时先区域释放阀后总控阀",{"key":31,"text":243,"correct":29},"开启时先区域释放阀后总控阀，关闭时先总控阀后区域释放阀",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":27,"analysis":33},964532,"高压二氧化碳灭火系统的使用环境温度为（ ）。",[248,250,252,254],{"key":20,"text":249,"correct":22},"0～+50℃",{"key":24,"text":251,"correct":22},"+4～+49℃",{"key":27,"text":253,"correct":29},"0～+49℃",{"key":31,"text":255,"correct":22},"0～+55℃",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":24,"analysis":33},964533,"低压二氧化碳气体灭火设备使用环境温度为（ ）。",[260,262,264,266],{"key":20,"text":261,"correct":22},"-22～-18℃",{"key":24,"text":263,"correct":29},"-23～+50℃",{"key":27,"text":265,"correct":22},"-20～-18℃",{"key":31,"text":267,"correct":22},"-23～+49℃",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":20,"analysis":33},964534,"气体灭火系统的灭火剂和驱动气体储存容器内的压力，不得小于设计储存压力（ ）。",[272,274,276,278],{"key":20,"text":273,"correct":29},"90%",{"key":24,"text":275,"correct":22},"95%",{"key":27,"text":277,"correct":22},"98%",{"key":31,"text":279,"correct":22},"压力表绿色区域下限",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":27,"analysis":33},964535,"低压二氧化碳灭火剂储存温度℃为：（ ）。",[284,286,288,290],{"key":20,"text":285,"correct":22},"-22～-18",{"key":24,"text":287,"correct":22},"-23～-50",{"key":27,"text":289,"correct":29},"-20～-18",{"key":31,"text":291,"correct":22},"-23～+49",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":27,"analysis":33},964536,"公共娱乐场所应使用（ ）。",[296,298,300,302],{"key":20,"text":297,"correct":22},"特殊响应喷头",{"key":24,"text":299,"correct":22},"标准响应喷头",{"key":27,"text":301,"correct":29},"快速响应喷头",{"key":31,"text":303,"correct":22},"以上任意一种都可以",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":24,"analysis":33},964537,"预作用装置的功能性检测下列描述错误的是：（ ）。",[308,310,312,314],{"key":20,"text":309,"correct":22},"模拟火灾探测报警，火灾报警控制器确认火灾后，自动启动预作用装置（雨淋报警阀）、排气阀入口电动阀以及消防水泵；水流指示器、压力开关动作。",{"key":24,"text":311,"correct":29},"报警阀组动作后，测试水水力警铃声强，不得低于80dB。",{"key":27,"text":313,"correct":22},"开启末端试水装置，火灾报警控制器确认火灾2min后，其出水压力不低于0.05MPA。",{"key":31,"text":315,"correct":22},"消防控制设备准确显示电磁阀、电动阀、水流指示器以及消防水泵动作信号，反馈信号准确。",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":31,"analysis":33},964538,"下列哪项不是预作用报警阀漏水故障原因（ ）。",[320,322,324,326],{"key":20,"text":321,"correct":22},"排水控制阀门未关紧。",{"key":24,"text":323,"correct":22},"阀瓣密封垫老化或者损坏。",{"key":27,"text":325,"correct":22},"复位杆未复位或者损坏。",{"key":31,"text":327,"correct":29},"压力表管路堵塞。",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":31,"analysis":33},964539,"下列哪项不是预作用报警阀组压力表读数不在正常范围故障原因（ ）。",[332,334,335,337],{"key":20,"text":333,"correct":22},"预作用装置前的供水控制阀未打开。",{"key":24,"text":327,"correct":22},{"key":27,"text":336,"correct":22},"预作用装置的报警阀体漏水。",{"key":31,"text":338,"correct":29},"消防用水水质存在问题。",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":33},964540,"对于预作用报警阀组，开启末端试水装置，火灾报警控制器确认火灾（ ）min后，其出水压力不低于0.05MPa。",[343,345,347,349],{"key":20,"text":344,"correct":22},"1",{"key":24,"text":346,"correct":29},"2",{"key":27,"text":348,"correct":22},"3",{"key":31,"text":350,"correct":22},"4",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":31,"analysis":33},964541,"雨淋阀组应（ ）做一次开阀功能试验。",[355,357,359,361],{"key":20,"text":356,"correct":22},"每月",{"key":24,"text":358,"correct":22},"每季度",{"key":27,"text":360,"correct":22},"每半年",{"key":31,"text":362,"correct":29},"每年",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":27,"analysis":33},964542,"雨淋阀组的雨淋装置及其辅件应（ ）进行一次维护保养。",[367,368,369,370],{"key":20,"text":356,"correct":22},{"key":24,"text":358,"correct":22},{"key":27,"text":360,"correct":29},{"key":31,"text":362,"correct":22},{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":24,"analysis":33},964543,"雨淋阀组应（ ）做一次主排水试验及报警试验",[375,376,377,378],{"key":20,"text":356,"correct":22},{"key":24,"text":358,"correct":29},{"key":27,"text":360,"correct":22},{"key":31,"text":362,"correct":22},{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":31,"analysis":33},964544,"预作用报警阀组的电磁阀启动测试至少（ ）进行一次检查与维护；",[383,385,387,389],{"key":20,"text":384,"correct":22},"每日",{"key":24,"text":386,"correct":22},"每周",{"key":27,"text":388,"correct":22},"每半月",{"key":31,"text":356,"correct":29},{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":24,"analysis":33},964545,"预作用报警阀组的试水阀放水及其启动性能测试至少（ ）进行一次检查与维护。",[394,395,396,397],{"key":20,"text":356,"correct":22},{"key":24,"text":358,"correct":29},{"key":27,"text":360,"correct":22},{"key":31,"text":362,"correct":22},{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":31,"analysis":33},964546,"预作用报警阀组的所有阀门状态及其铅封、锁链完好状况检查，至少应（ ）进行一次检查与维护。",[402,403,404,405],{"key":20,"text":384,"correct":22},{"key":24,"text":386,"correct":22},{"key":27,"text":388,"correct":22},{"key":31,"text":356,"correct":29},{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":24,"analysis":33},964547,"预作用报警阀组在火灾扑灭后，应将电磁阀关闭，使雨淋阀关闭，并排除管中的水使系统充气压力保持在（ ）MPA范围内，恢复准工作状态。",[410,412,414,416],{"key":20,"text":411,"correct":22},"0.01-0.03",{"key":24,"text":413,"correct":29},"0.03-0.05",{"key":27,"text":415,"correct":22},"0.05-0.07",{"key":31,"text":417,"correct":22},"0.07-0.09",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":24,"analysis":33},964548,"干式报警阀应（ ）对水压表进行检查，确保系统维持正常的水压。",[422,423,424,425],{"key":20,"text":384,"correct":22},{"key":24,"text":386,"correct":29},{"key":27,"text":388,"correct":22},{"key":31,"text":356,"correct":22},{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":31,"analysis":33},964549,"根据《气体灭火系统设计规范》的总则规定，气体灭火系统的施工及验收，维护管理，除执行《气体灭火系统施工及验收规范》的规定外尚应符合（ ）的规定。",[430,432,434,436],{"key":20,"text":431,"correct":22},"行业标准",{"key":24,"text":433,"correct":22},"地方标准",{"key":27,"text":435,"correct":22},"外国标准",{"key":31,"text":437,"correct":29},"国家现行的有关标准的规定",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":27,"analysis":33},964550,"气体灭火系统的检漏装置用于监测瓶组内介质的压力或质量损失，其不包括（ ）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"称重装置",{"key":24,"text":445,"correct":22},"压力显示器",{"key":27,"text":447,"correct":29},"压力开关",{"key":31,"text":449,"correct":22},"液位测量装置",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":24,"analysis":33},964551,"具有气体灭火功能的火灾报警控制器在接收到满足联动逻辑关系的首个触发信号后，应启动设置在该防护区内的（ ）。",[454,456,458,460],{"key":20,"text":455,"correct":22},"气体灭火系统",{"key":24,"text":457,"correct":29},"火灾声、光警报器",{"key":27,"text":459,"correct":22},"气体释放灯",{"key":31,"text":461,"correct":22},"紧急启停按钮",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":27,"analysis":33},964552,"气体灭火系统中，火灾报警控制器在接收到同一防护区域内两个触发信号后，延时（ ）s应发出联动控制信号。",[466,468,470,472],{"key":20,"text":467,"correct":22},"10",{"key":24,"text":469,"correct":22},"20",{"key":27,"text":471,"correct":29},"30",{"key":31,"text":473,"correct":22},"60",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":33},964553,"下列（ ）是高级建（构）筑物消防员的应具备的职业技能。",[478,480,482,484],{"key":20,"text":479,"correct":22},"能识别各种火源，并能判断违章用火行为",{"key":24,"text":481,"correct":29},"能识别常见易燃易爆化学危险物品，并能判定违法使用、储存行为",{"key":27,"text":483,"correct":22},"能对消防安全重点部位的人员在岗情况进行核查与评价",{"key":31,"text":485,"correct":22},"能判断疏散指示标志和应急照明是否完好",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":27,"analysis":33},964554,"紧固自动喷水灭火系统洒水喷头安装时应（ ）。",[490,492,494,496],{"key":20,"text":491,"correct":22},"利用喷头的框架施拧",{"key":24,"text":493,"correct":22},"先将喷头进行调整、心动",{"key":27,"text":495,"correct":29},"使用专用扳手",{"key":31,"text":497,"correct":22},"先将喷头拆装",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":27,"analysis":33},964555,"由于水本身是一种良好的溶剂，可以溶解水榕性液体，降低可燃物浓度，而具有的灭火作用是（ ）。",[502,504,506,508],{"key":20,"text":503,"correct":22},"冷却作用",{"key":24,"text":505,"correct":22},"窒息作用",{"key":27,"text":507,"correct":29},"稀释作用",{"key":31,"text":509,"correct":22},"分离作用",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":27,"analysis":33},964556,"设有自动喷水灭火系统的防火分区，其允许最大建筑面积可按要求增加（ ）。",[514,516,518,520],{"key":20,"text":515,"correct":22},"20%",{"key":24,"text":517,"correct":22},"50%",{"key":27,"text":519,"correct":29},"—倍",{"key":31,"text":521,"correct":22},"二倍",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":31,"analysis":33},964557,"下列对应釆用预作用自动喷水灭火系统的说法，不正确的是（ ）。",[526,528,530,532],{"key":20,"text":527,"correct":22},"系统处于准工作状态时，严禁管道漏水",{"key":24,"text":529,"correct":22},"严禁系统误喷",{"key":27,"text":531,"correct":22},"替代干式系统",{"key":31,"text":533,"correct":29},"替代湿式系统",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":31,"analysis":33},964558,"建筑高度54m的宾馆，其屋项设置的高位消防水箱有效容积应（ ）。",[538,540,542,544],{"key":20,"text":539,"correct":22},"100m3",{"key":24,"text":541,"correct":22},"80m3",{"key":27,"text":543,"correct":22},"50m3",{"key":31,"text":545,"correct":29},"36m3",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":24,"analysis":33},964559,"干式系统、预作用系统的供气管道，釆用钢管时，管径不宜小于（ ）mm；釆用铜管时，管径不宜小于（ ）mm。",[550,552,554,556],{"key":20,"text":551,"correct":22},"10；5",{"key":24,"text":553,"correct":29},"15；10",{"key":27,"text":555,"correct":22},"20；15",{"key":31,"text":557,"correct":22},"25；20",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":20,"analysis":33},964560,"末端试水装置应由试水阀、压力表以及（ ）组成。",[562,564,566,568],{"key":20,"text":563,"correct":29},"试水接头",{"key":24,"text":565,"correct":22},"喷头",{"key":27,"text":567,"correct":22},"软管",{"key":31,"text":569,"correct":22},"警铃",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":20,"analysis":33},964561,"干式系统的配水管道充水时间，不宜大于（ ）min。",[574,575,576,577],{"key":20,"text":344,"correct":29},{"key":24,"text":346,"correct":22},{"key":27,"text":348,"correct":22},{"key":31,"text":350,"correct":22},{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":31,"analysis":33},964562,"不属于末端试水装置的作用是（ ）。",[582,584,586,588],{"key":20,"text":583,"correct":22},"测定最不利点处喷头的工作压力",{"key":24,"text":585,"correct":22},"测定配水管道是否畅通",{"key":27,"text":587,"correct":22},"测定自动喷水灭火系统的工况是否正常",{"key":31,"text":589,"correct":29},"直接启动消防水泵",[591,594,597,600,603,606],{"id":15,"name":592,"category":7,"favorite":593},"领导干部任职前廉政法规知识测试题",92,{"id":595,"name":596,"category":7,"favorite":15},595,"建筑结构与设备",{"id":598,"name":599,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":601,"name":602,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":604,"name":605,"category":7,"favorite":8},534,"BIM工程师",{"id":607,"name":605,"category":7,"favorite":8},535]