[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-50":3},{"library":4,"page":9,"limit":9,"total":10,"questions":11,"related":321},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,50,2716,[12,27,33,39,45,51,57,63,69,75,81,87,93,99,105,111,117,123,129,135,141,147,153,159,165,171,177,183,189,195,201,207,213,219,225,231,237,243,249,255,261,267,273,279,285,291,297,303,309,315],{"id":13,"libraryId":5,"type":14,"typeLabel":15,"stem":16,"options":17,"answer":24,"analysis":26},966685,3,"判断题","二氧化碳灭火剂灭火机理主要是物理作用和化学作用。",[18,22],{"key":19,"text":20,"correct":21},"A","正确",false,{"key":23,"text":24,"correct":25},"B","错误",true,"",{"id":28,"libraryId":5,"type":14,"typeLabel":15,"stem":29,"options":30,"answer":24,"analysis":26},966686,"灭火器的配置设计涉及到许多方面，形式多种多样，但一般可按下述步骤和要求进行考虑和设计，如：计算每个灭火器设置点的最大需配灭火级别。",[31,32],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":34,"libraryId":5,"type":14,"typeLabel":15,"stem":35,"options":36,"answer":24,"analysis":26},966687,"沥青火灾属于A类火灾。",[37,38],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":40,"libraryId":5,"type":14,"typeLabel":15,"stem":41,"options":42,"answer":20,"analysis":26},966688,"每个设置点的灭火器数置不宜多于5个。",[43,44],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":46,"libraryId":5,"type":14,"typeLabel":15,"stem":47,"options":48,"answer":24,"analysis":26},966689,"A类火灾场所中危险级单位灭火级别最大保护面积应为50（m2\u002FA）。",[49,50],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":52,"libraryId":5,"type":14,"typeLabel":15,"stem":53,"options":54,"answer":20,"analysis":26},966690,"镁、铝等金属粉末燃烧，只能用干砂、干粉灭火。严禁用水、酸碱灭火剂、泡沫灭火剂以及二氧化碳灭火。",[55,56],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":58,"libraryId":5,"type":14,"typeLabel":15,"stem":59,"options":60,"answer":20,"analysis":26},966691,"筒体严重锈蚀（锈蚀面积大于、等于筒体总面积的三分之一，表面产生凹坑）的灭火器应予以报废处理。",[61,62],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":64,"libraryId":5,"type":14,"typeLabel":15,"stem":65,"options":66,"answer":24,"analysis":26},966692,"设在楼梯间的消防应急灯具地面最低水平照度不应低于0.5lx。",[67,68],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":70,"libraryId":5,"type":14,"typeLabel":15,"stem":71,"options":72,"answer":24,"analysis":26},966693,"灭火器配置设计时，计算单元的保护面积按照其使用面积划分。",[73,74],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":76,"libraryId":5,"type":14,"typeLabel":15,"stem":77,"options":78,"answer":20,"analysis":26},966694,"某综合楼内的网吧设在地下一层，其计算单元的最小需配灭火级别应增加30%。",[79,80],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":82,"libraryId":5,"type":14,"typeLabel":15,"stem":83,"options":84,"answer":20,"analysis":26},966695,"广播模块接线错误，既可能导致“干线故障”也可能导“支线故障”",[85,86],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":88,"libraryId":5,"type":14,"typeLabel":15,"stem":89,"options":90,"answer":24,"analysis":26},966696,"消防电话系统线路常见故障一般有分机线路故障、插孔线路故障、干线故障和支线故障等。",[91,92],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":94,"libraryId":5,"type":14,"typeLabel":15,"stem":95,"options":96,"answer":24,"analysis":26},966697,"若模块接线错误，由消防电话总机显示“总线故障”消防电话系统所有分机、插孔均无法与总机通信。",[97,98],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":100,"libraryId":5,"type":14,"typeLabel":15,"stem":101,"options":102,"answer":24,"analysis":26},966698,"消防电话总机显示“插孔故障”，该插孔与总机无法通信，需要更换电话分机。",[103,104],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":106,"libraryId":5,"type":14,"typeLabel":15,"stem":107,"options":108,"answer":24,"analysis":26},966699,"分机与电话总机线路断开，该分机与总机仍能正常通信。",[109,110],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":112,"libraryId":5,"type":14,"typeLabel":15,"stem":113,"options":114,"answer":24,"analysis":26},966700,"某个电话分机或电话插孔损坏，维修或更换即可，不会导致“总线故障”。",[115,116],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":118,"libraryId":5,"type":14,"typeLabel":15,"stem":119,"options":120,"answer":24,"analysis":26},966701,"电气火灾监控系统线路釆用通用线路与电气火灾监控探测器连接，釆用树形总线形式布线。",[121,122],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":124,"libraryId":5,"type":14,"typeLabel":15,"stem":125,"options":126,"answer":24,"analysis":26},966702,"电气火灾监控系统若有故障，即是电气火灾监控系统通信线路故障。",[127,128],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":130,"libraryId":5,"type":14,"typeLabel":15,"stem":131,"options":132,"answer":24,"analysis":26},966703,"电气火灾监控系统设备故障，指的是探测器损坏或线路故障。",[133,134],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":136,"libraryId":5,"type":14,"typeLabel":15,"stem":137,"options":138,"answer":24,"analysis":26},966704,"监控设备未开启是电气火灾监控系统线路故障的一种。",[139,140],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":142,"libraryId":5,"type":14,"typeLabel":15,"stem":143,"options":144,"answer":24,"analysis":26},966705,"探测总线短路、断路、过流、过载都会造成电气火灾监控系统线路故障。",[145,146],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":148,"libraryId":5,"type":14,"typeLabel":15,"stem":149,"options":150,"answer":24,"analysis":26},966706,"监控设备与探测器线路未连接，电气火灾监控系统线路故障时，将线路重新连接即可，下次维保时再进行测试。",[151,152],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":154,"libraryId":5,"type":14,"typeLabel":15,"stem":155,"options":156,"answer":24,"analysis":26},966707,"若传感组件线路断路或短路，可将线路重新连接，进行测试。",[157,158],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":160,"libraryId":5,"type":14,"typeLabel":15,"stem":161,"options":162,"answer":24,"analysis":26},966708,"应急照明集中电源输出回路故障的原因是输入回路断路、短路或过载保护。",[163,164],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":166,"libraryId":5,"type":14,"typeLabel":15,"stem":167,"options":168,"answer":24,"analysis":26},966709,"应急照明集中电源持续应急时间不达标的原因是集中电源损坏。",[169,170],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":172,"libraryId":5,"type":14,"typeLabel":15,"stem":173,"options":174,"answer":24,"analysis":26},966710,"灯板、显示板接线不良会造成应急照明配电箱无显示或显示不正常。",[175,176],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":178,"libraryId":5,"type":14,"typeLabel":15,"stem":179,"options":180,"answer":24,"analysis":26},966711,"应急照明配电箱显示“主电故障”的原因是应急照明配电箱损坏。",[181,182],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":184,"libraryId":5,"type":14,"typeLabel":15,"stem":185,"options":186,"answer":24,"analysis":26},966712,"应急照明配电箱输出回路故障的原因是主电源接线不良或熔丝烧断。",[187,188],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":190,"libraryId":5,"type":14,"typeLabel":15,"stem":191,"options":192,"answer":24,"analysis":26},966713,"控制器显示“应急照明配电箱故障”的原因是主板损坏。",[193,194],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":196,"libraryId":5,"type":14,"typeLabel":15,"stem":197,"options":198,"answer":24,"analysis":26},966714,"灯具光源不能应急点亮是因为蓄电池容量不足。",[199,200],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":202,"libraryId":5,"type":14,"typeLabel":15,"stem":203,"options":204,"answer":20,"analysis":26},966715,"标志灯标识信息不完整的原因是灯具损坏。",[205,206],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":208,"libraryId":5,"type":14,"typeLabel":15,"stem":209,"options":210,"answer":24,"analysis":26},966716,"灯具损坏后，照明灯具设置部位的地面水平照度不能满足要求。",[211,212],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":214,"libraryId":5,"type":14,"typeLabel":15,"stem":215,"options":216,"answer":24,"analysis":26},966717,"控制器显示某一“灯具故障”，是因为集中电源或应急照明配电箱输出回路总线短路、断路。",[217,218],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":220,"libraryId":5,"type":14,"typeLabel":15,"stem":221,"options":222,"answer":24,"analysis":26},966718,"控制器显示集中电源或应急照明配电箱配接的多个“灯具故障”的原因是灯具与集中电源或应急照明配电箱间接线不良。",[223,224],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":226,"libraryId":5,"type":14,"typeLabel":15,"stem":227,"options":228,"answer":24,"analysis":26},966719,"集中电源或应急照明配电箱输出回路总线短路、断路是应急照明控制器不能自动控制系统设备应急启动、标志灯指示状态改变的原因。",[229,230],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":232,"libraryId":5,"type":14,"typeLabel":15,"stem":233,"options":234,"answer":20,"analysis":26},966720,"根据可燃物的类型和燃烧特性，将火灾定义为A类、B类、C类、D类、E类、F类六类不同的类别。",[235,236],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":238,"libraryId":5,"type":14,"typeLabel":15,"stem":239,"options":240,"answer":20,"analysis":26},966721,"火焰的颜色取决于燃饶物质的化学成分和助燃物的供应强度。",[241,242],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":244,"libraryId":5,"type":14,"typeLabel":15,"stem":245,"options":246,"answer":24,"analysis":26},966722,"泡沫灭火器可以扑救可燃液体和可燃气体火灾",[247,248],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":250,"libraryId":5,"type":14,"typeLabel":15,"stem":251,"options":252,"answer":20,"analysis":26},966723,"灭火器的最大保护距离与火灾种类、危险等级、灭火器型式有关，与设置点配置灭火器的规格、数量无关。",[253,254],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":256,"libraryId":5,"type":14,"typeLabel":15,"stem":257,"options":258,"answer":20,"analysis":26},966724,"灭火器的保护距离是指灭火器配置场所内，灭火器设置点到最不利点的直线行走距离。",[259,260],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":262,"libraryId":5,"type":14,"typeLabel":15,"stem":263,"options":264,"answer":24,"analysis":26},966725,"煤油引起的火灾属于C类火灾。",[265,266],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":268,"libraryId":5,"type":14,"typeLabel":15,"stem":269,"options":270,"answer":20,"analysis":26},966726,"使用性质需要，人员密集，用电用火多。可燃物多。起火后蔓延迅速，扑救困难，容易造成重大财产损失或人员群死群伤的场所属于工业建筑灭火器配置场所的严重危险等级。",[271,272],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":274,"libraryId":5,"type":14,"typeLabel":15,"stem":275,"options":276,"answer":24,"analysis":26},966727,"灭火器（箱）不应被遮挡、拴系或上锁属于建筑灭火器配置缺陷项分类中的轻缺陷。",[277,278],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":280,"libraryId":5,"type":14,"typeLabel":15,"stem":281,"options":282,"answer":20,"analysis":26},966728,"简单体严重锈蚀（锈蚀面积大于、等于筒体总面积的三分之一，表面产生凹坑）的灭火器应予以报废处理。",[283,284],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":286,"libraryId":5,"type":14,"typeLabel":15,"stem":287,"options":288,"answer":20,"analysis":26},966729,"水基型（水雾、泡沫）灭火器可用于B类火灾的扑救。",[289,290],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":292,"libraryId":5,"type":14,"typeLabel":15,"stem":293,"options":294,"answer":20,"analysis":26},966730,"一个计算单元内配置的灭火器数量不得少于2个。",[295,296],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":298,"libraryId":5,"type":14,"typeLabel":15,"stem":299,"options":300,"answer":20,"analysis":26},966731,"电气线路发生火灾，主要是由于线路的过载、短路、接触不良、漏电等原因导致产生电弧、电火花或线路过热，引燃电线、电缆及其周围的可燃物引起。",[301,302],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":304,"libraryId":5,"type":14,"typeLabel":15,"stem":305,"options":306,"answer":20,"analysis":26},966732,"火灾隐患通常是指单位、场所、设备以及人们的行为违反消防法律、法规、有引起火灾或爆炸事故、危及生命财产安全、阻碍火灾扑救等潜在的危险因素和条件。",[307,308],{"key":19,"text":20,"correct":25},{"key":23,"text":24,"correct":21},{"id":310,"libraryId":5,"type":14,"typeLabel":15,"stem":311,"options":312,"answer":24,"analysis":26},966733,"热传导是指以电磁波形式传递热量的现象。",[313,314],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},{"id":316,"libraryId":5,"type":14,"typeLabel":15,"stem":317,"options":318,"answer":24,"analysis":26},966734,"一切可燃液体时燃点都低于闪点。",[319,320],{"key":19,"text":20,"correct":21},{"key":23,"text":24,"correct":25},[322,326,329,332,335,338],{"id":323,"name":324,"category":7,"favorite":325},1,"领导干部任职前廉政法规知识测试题",92,{"id":327,"name":328,"category":7,"favorite":323},595,"建筑结构与设备",{"id":330,"name":331,"category":7,"favorite":323},715,"招标采购专业知识与法律法规",{"id":333,"name":334,"category":7,"favorite":323},848,"市政方向-通用基础",{"id":336,"name":337,"category":7,"favorite":8},534,"BIM工程师",{"id":339,"name":337,"category":7,"favorite":8},535]