[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":586},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,5,50,2716,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,186,198,210,219,231,243,253,261,269,281,293,303,311,320,332,344,356,368,380,392,404,416,428,440,452,461,473,483,495,506,518,529,541,553,564,576],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},964413,1,"单选题","在消防控制室图形显示装置（CRT）中，对于报警状态信息显示描述不正确的是（ ）?",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","报警指示：“火警”指示为红色，可以自动清除",true,{"key":24,"text":25,"correct":26},"B","声响音调：发出与其它信息不同的火警声",false,{"key":28,"text":29,"correct":26},"C","图形显示部分对应的报警设备以红色闪烁，报警设备所在区域也以红色显示",{"key":31,"text":32,"correct":26},"D","通过查看文字信息能获得每一个火灾报警部位及相关信息","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},964414,"城市隧道室内消火栓系统管道内的消防供水压力应保证用水量达到最大时，最低压力不应小于（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"0.10MPa",{"key":24,"text":41,"correct":26},"0.15MPa",{"key":28,"text":43,"correct":22},"0.30MPa",{"key":31,"text":45,"correct":26},"0.50MPa",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},964415,"在火灾自动报警系统中，对于消防广播自动启动的描述，不正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"广播控制器接收广播联动信号后，可以按照预设逻辑选择广播区域并启动消防广播",{"key":24,"text":53,"correct":22},"消防广播灯闪亮",{"key":28,"text":55,"correct":26},"液晶屏显示消防广播状态",{"key":31,"text":57,"correct":26},"液晶屏显示选择的广播区域",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},964416,"在消防控制室图形显示装置（CRT）中，点击“消音”键，可消除图形显示装置的（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"火警或故障警报声",{"key":24,"text":65,"correct":26},"火警或反馈声",{"key":28,"text":67,"correct":26},"反馈或故障警报声",{"key":31,"text":69,"correct":26},"监管或故障警报声",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},964417,"火灾报警控制器在故障状态下，对信息特征描述不正确的一项是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"点亮“故障”指示灯，故障排除后，故障信息的指示信号需要手动清除",{"key":24,"text":77,"correct":26},"声响音调：发出与火警信息明显不同的故障声",{"key":28,"text":79,"correct":26},"显示故障总数和故障报警序号、报警时间、类型编码",{"key":31,"text":81,"correct":26},"主备电发生故障，发出声、光报警",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},964418,"火灾报警控制器主面板上，显示系统运行正常，以下哪一项指示灯点亮属于异常。（ ）",[86,88,90,92],{"key":20,"text":87,"correct":26},"主电工作灯或备电工作灯",{"key":24,"text":89,"correct":26},"自动允许灯",{"key":28,"text":91,"correct":26},"喷洒允许灯",{"key":31,"text":93,"correct":22},"屏蔽指示灯",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},964419,"在消防监控系统中，值班人员可以通过（ ），能够直观地了解消防工程设备分布情况。",[98,100,102,104],{"key":20,"text":99,"correct":26},"报警控制器主界面",{"key":24,"text":101,"correct":26},"电话联系",{"key":28,"text":103,"correct":22},"图形显示装置监视主界面",{"key":31,"text":105,"correct":26},"查看现场",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},964420,"在消防控制室图形显示装置（CRT）中，日志记录显示中查询不到的是（ ）?",[110,112,114,116],{"key":20,"text":111,"correct":26},"用户名称",{"key":24,"text":113,"correct":26},"控制器地址",{"key":28,"text":115,"correct":22},"信息参数",{"key":31,"text":117,"correct":26},"信息内容",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},964421,"防烟自动控制方式：由满足预设逻辑的（ ）的报警信号联动送风口的开启。",[122,124,126,128],{"key":20,"text":123,"correct":26},"消火栓按钮",{"key":24,"text":125,"correct":22},"烟感探测器",{"key":28,"text":127,"correct":26},"输入输出模块",{"key":31,"text":129,"correct":26},"输入模块",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},964422,"在火灾报警系统中，（ ）是控制消防报警系统中重要设备（喷淋泵、消防泵、排烟机、送风机）的设施。",[134,136,138,140],{"key":20,"text":135,"correct":26},"手动消防盘",{"key":24,"text":137,"correct":22},"直接控制盘",{"key":28,"text":139,"correct":26},"动力电源盘",{"key":31,"text":141,"correct":26},"应急启动盘",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},964423,"打开位于消防电话主机机箱背面的“电源”开关，如无呼入、呼出等信号，则处于（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"正常监视状态",{"key":24,"text":149,"correct":26},"自检状态",{"key":28,"text":151,"correct":26},"屏蔽状态",{"key":31,"text":153,"correct":26},"监管状态",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},964424,"在消防电话系统中，按下（ ），可以挂断正在呼入、通话的分机，或取消当前呼出显示的分机。",[158,160,162,164],{"key":20,"text":159,"correct":26},"复位键",{"key":24,"text":161,"correct":26},"消音键",{"key":28,"text":163,"correct":26},"接通键",{"key":31,"text":165,"correct":22},"挂断键",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":20,"analysis":33},964425,"在消防电话系统中，当主机和分机处于通话状态时，（ ）红色灯常亮。",[170,172,174,176],{"key":20,"text":171,"correct":22},"通话",{"key":24,"text":173,"correct":26},"呼叫",{"key":28,"text":175,"correct":26},"故障",{"key":31,"text":177,"correct":26},"工作",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},964426,"在消防电话系统中，当有分机呼入时，（ ）红色灯闪亮。",[182,183,184,185],{"key":20,"text":171,"correct":26},{"key":24,"text":173,"correct":22},{"key":28,"text":175,"correct":26},{"key":31,"text":177,"correct":26},{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":20,"analysis":33},964427,"在火灾报警系统中，消防广播控制器接收到（ ）信号后，按照预设逻辑选择广播区域并启动应急广播。",[190,192,194,196],{"key":20,"text":191,"correct":22},"广播联动",{"key":24,"text":193,"correct":26},"广播反馈",{"key":28,"text":195,"correct":26},"模块联动",{"key":31,"text":197,"correct":26},"火灾报警",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":20,"analysis":33},964428,"在火灾报警系统中，消防应急广播主界面信息特征，描述不正确的一项是（ ）。",[202,204,206,208],{"key":20,"text":203,"correct":22},"当主机上主电初始化完成后听到一声长鸣，系统进入调试状态",{"key":24,"text":205,"correct":26},"工作灯点亮",{"key":28,"text":207,"correct":26},"液晶显示正常广播状态",{"key":31,"text":209,"correct":26},"工作区总数00，当前区号00，故障总数00，故障区号00",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":20,"analysis":33},964429,"打开消防应急广播机箱背面的“电源”开关，如无故障等信号，则处于（ ）。",[214,215,216,217],{"key":20,"text":147,"correct":22},{"key":24,"text":149,"correct":26},{"key":28,"text":151,"correct":26},{"key":31,"text":218,"correct":26},"故障报警状态",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":20,"analysis":33},964430,"图形显示装置（CRT）监视主界面分四部分：工程配置信息，图形显示部分，信息指示部分，操作部分。其中（ ）以树状结构显示配置的消防工程分区。",[223,225,227,229],{"key":20,"text":224,"correct":22},"工程配置信息",{"key":24,"text":226,"correct":26},"图形显示部分",{"key":28,"text":228,"correct":26},"信息指示部分",{"key":31,"text":230,"correct":26},"操作部分",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":20,"analysis":33},964431,"在火灾报警控制器上，操作面板上有（ ）键，按下此键可以查看系统存储的各类信息。",[235,237,239,241],{"key":20,"text":236,"correct":22},"记录检查",{"key":24,"text":238,"correct":26},"设备检查",{"key":28,"text":240,"correct":26},"系统设置",{"key":31,"text":242,"correct":26},"自检",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":28,"analysis":33},964432,"在火灾报警控制器上，按下（ ）可对火灾报警控制器的音响器件、面板上所有指示灯、显示器进行检查，也可以对消防联动控制器状态指示灯进行检查。",[247,248,249,251],{"key":20,"text":161,"correct":26},{"key":24,"text":159,"correct":26},{"key":28,"text":250,"correct":22},"自检键",{"key":31,"text":252,"correct":26},"取消键",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":24,"analysis":33},964433,"在火灾报警控制器上，按下（ ）可使火灾自动报警系统或系统内各组成部分恢复到正常监视状态。",[257,258,259,260],{"key":20,"text":161,"correct":26},{"key":24,"text":159,"correct":22},{"key":28,"text":250,"correct":26},{"key":31,"text":252,"correct":26},{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":33},964434,"在火灾报警控制器上，按下（ ）可消除火灾报警控制器发出的火警或故障警报声。",[265,266,267,268],{"key":20,"text":161,"correct":22},{"key":24,"text":159,"correct":26},{"key":28,"text":250,"correct":26},{"key":31,"text":252,"correct":26},{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":24,"analysis":33},964435,"在火灾报警控制器上，（ ）灯亮，表示报警系统内的声光警报器处于消音状态。",[273,275,277,279],{"key":20,"text":274,"correct":26},"反馈",{"key":24,"text":276,"correct":22},"警报器消音指示",{"key":28,"text":278,"correct":26},"声光警报器故障指示",{"key":31,"text":280,"correct":26},"声光警报器屏蔽指示",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":28,"analysis":33},964436,"在火灾报警控制器上，（ ）灯亮，表示当前控制器由备电源供电。",[285,287,289,291],{"key":20,"text":286,"correct":26},"火警",{"key":24,"text":288,"correct":26},"主电工作",{"key":28,"text":290,"correct":22},"备电工作",{"key":31,"text":292,"correct":26},"屏蔽",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":31,"analysis":33},964437,"在火灾报警控制器上，（ ）灯亮，表示控制器处于不能正常使用的故障状态。",[297,298,300,301],{"key":20,"text":286,"correct":26},{"key":24,"text":299,"correct":26},"启动",{"key":28,"text":274,"correct":26},{"key":31,"text":302,"correct":22},"系统故障",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":31,"analysis":33},964438,"在火灾报警控制器上，（ ）灯亮，表示有设备处于被屏蔽状态。",[307,308,309,310],{"key":20,"text":286,"correct":26},{"key":24,"text":299,"correct":26},{"key":28,"text":274,"correct":26},{"key":31,"text":292,"correct":22},{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":20,"analysis":33},964439,"在火灾报警控制器上，（ ）灯亮，表示控制器检测到外接探测器处于火警状态。",[315,316,317,318],{"key":20,"text":286,"correct":22},{"key":24,"text":299,"correct":26},{"key":28,"text":274,"correct":26},{"key":31,"text":319,"correct":26},"监管",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":20,"analysis":33},964440,"火灾报警控制器开机的顺序（ ）。",[324,326,328,330],{"key":20,"text":325,"correct":22},"主电电源开关、备用电开关、控制器工作开关",{"key":24,"text":327,"correct":26},"备用电开关、主电电源开关、控制器工作开关",{"key":28,"text":329,"correct":26},"控制器工作开关、主电电源开关、备用电开关",{"key":31,"text":331,"correct":26},"无任何顺序",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":31,"analysis":33},964441,"在防护区域内设有手动与自动控制转换装置的气体灭火系统，其手动或自动控制方式的工作状态应在防护区（ ）的手动和自动控制状态显示装置上显示，该状态信号应反馈至消防联动控制器。",[336,338,340,342],{"key":20,"text":337,"correct":26},"内",{"key":24,"text":339,"correct":26},"外",{"key":28,"text":341,"correct":26},"内或外",{"key":31,"text":343,"correct":22},"内、外",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":28,"analysis":33},964442,"从一个防火分区内的任何位置到最邻近的一个手动火灾报警按钮的距离，不应大于（ ）m。",[348,350,352,354],{"key":20,"text":349,"correct":26},"20",{"key":24,"text":351,"correct":26},"25",{"key":28,"text":353,"correct":22},"30",{"key":31,"text":355,"correct":26},"40",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":28,"analysis":33},964443,"恢复火灾报警控制器的主电源后，备用电源应自动（ ）。",[360,362,364,366],{"key":20,"text":361,"correct":26},"投入",{"key":24,"text":363,"correct":26},"保留",{"key":28,"text":365,"correct":22},"切断",{"key":31,"text":367,"correct":26},"维持",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":24,"analysis":33},964444,"火灾应急广播应设备用扩音机，其容量不应小于火灾需要同时广播的范围内的火灾应急广播扬声器最大容量总和的（ ）倍。",[372,374,376,378],{"key":20,"text":373,"correct":26},"1.2",{"key":24,"text":375,"correct":22},"1.5",{"key":28,"text":377,"correct":26},"2",{"key":31,"text":379,"correct":26},"2.5",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":24,"analysis":33},964445,"消防联动控制设备能以手动或自动两种方式完成相应的联动控制功能，能指示手动或自动操作方式的工作状态。在自动方式操作过程中，（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":26},"自动操作",{"key":24,"text":387,"correct":22},"手动插入操作",{"key":28,"text":389,"correct":26},"逻辑控制",{"key":31,"text":391,"correct":26},"任何操作均不",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":24,"analysis":33},964446,"声报警信号应能手动消除，但再次有火警信号输入时，（ ）能在再次启动。",[396,398,400,402],{"key":20,"text":397,"correct":26},"不",{"key":24,"text":399,"correct":22},"应",{"key":28,"text":401,"correct":26},"只",{"key":31,"text":403,"correct":26},"可",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":31,"analysis":33},964447,"光报警信号在消防联动控制设备复位前应予以（ ）?",[408,410,412,414],{"key":20,"text":409,"correct":26},"记录",{"key":24,"text":411,"correct":26},"消除",{"key":28,"text":413,"correct":26},"确认",{"key":31,"text":415,"correct":22},"保持",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":31,"analysis":33},964448,"引入控制器的电缆或导线，端子板的每个接线端，接线不得超过（ ）根，电缆芯和导线，应留有不小于（ ）cm的余量。",[420,422,424,426],{"key":20,"text":421,"correct":26},"4 20",{"key":24,"text":423,"correct":26},"4 30",{"key":28,"text":425,"correct":26},"2 30",{"key":31,"text":427,"correct":22},"2 20",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":20,"analysis":33},964449,"金属管子入盒，盒外侧应套（ ），内侧应装（ ）；在吊顶内敷设时，盒的内外侧均应套锁母。",[432,434,436,438],{"key":20,"text":433,"correct":22},"锁母；护口",{"key":24,"text":435,"correct":26},"护口；锁母",{"key":28,"text":437,"correct":26},"锁母；锁母",{"key":31,"text":439,"correct":26},"护口；护口",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":20,"analysis":33},964450,"同一工程中的导线，应根据不同用途选不同颜色加以区分，相同用途的导线颜色应一致。电源线正级应为（ ）色，负极应为（ ）色或（ ）色。",[444,446,448,450],{"key":20,"text":445,"correct":22},"红；蓝；黑",{"key":24,"text":447,"correct":26},"蓝；红；黑",{"key":28,"text":449,"correct":26},"黄；蓝；红",{"key":31,"text":451,"correct":26},"红；黄；蓝",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":28,"analysis":33},964451,"民用建筑内火灾应急广播扬声器设置在走道或大厅等公共场所时，每个扬声器的额定功率不应小于3W，其数量应能保证从一个防火分区内的任何部位到最近一个扬声器的距离不大于（ ）m",[456,458,459,460],{"key":20,"text":457,"correct":26},"15",{"key":24,"text":349,"correct":26},{"key":28,"text":351,"correct":22},{"key":31,"text":353,"correct":26},{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":28,"analysis":33},964452,"气体灭火防护区应有能在30s内使该区人员疏散完毕的走道和出口，在疏散走道和出口处，应设（ ）。",[465,467,469,471],{"key":20,"text":466,"correct":26},"火灾事故广播和感烟探测器",{"key":24,"text":468,"correct":26},"疏散指示标志和感温探测器",{"key":28,"text":470,"correct":22},"火灾事故照明和疏散指示标志",{"key":31,"text":472,"correct":26},"感烟和感温探测器",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":28,"analysis":33},964453,"在设置气体灭火系统的防护区内，应设有疏散通道和安全出口，使人员能在（ ）s内撒离防护区。",[477,479,481,482],{"key":20,"text":478,"correct":26},"60",{"key":24,"text":480,"correct":26},"50",{"key":28,"text":353,"correct":22},{"key":31,"text":457,"correct":26},{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":28,"analysis":33},964454,"消防电梯前室或合用前室的门不允许釆用（ ）。",[487,489,491,493],{"key":20,"text":488,"correct":26},"防火门",{"key":24,"text":490,"correct":26},"防火窗",{"key":28,"text":492,"correct":22},"防火卷帘",{"key":31,"text":494,"correct":26},"防火隔墙",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":20,"analysis":33},964455,"光警报器与消防应急疏散指示标志不宜在同一面墙上，安装在同一面墙上时，距离应大于（ ）m。",[499,501,503,505],{"key":20,"text":500,"correct":22},"1",{"key":24,"text":502,"correct":26},"1.8",{"key":28,"text":504,"correct":26},"2.2",{"key":31,"text":379,"correct":26},{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":28,"analysis":33},964456,"火灾声警报器单次发出火灾警报时间宜为（ ），同时设有消防应急广播时，火灾声警报应与消防应急广播交替循环播放。",[510,512,514,516],{"key":20,"text":511,"correct":26},"4-10s",{"key":24,"text":513,"correct":26},"6-10s",{"key":28,"text":515,"correct":22},"8-20s",{"key":31,"text":517,"correct":26},"10-20s",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":28,"analysis":33},964457,"消防广播的单次语音播放时间宜为（ ），应与火灾声警报器分时交替工作，可釆取1次火灾声警报器播放、1次或2次消防应急广播播放的交替工作方式循环播放。",[522,523,525,527],{"key":20,"text":517,"correct":26},{"key":24,"text":524,"correct":26},"15-20s",{"key":28,"text":526,"correct":22},"10-30s",{"key":31,"text":528,"correct":26},"15-30s",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":28,"analysis":33},964458,"广播区域控制盘正常工作中，若消防联动控制器故障报警，但消防广播机无故障报警。应检查消防联动控制器与消防广播之间的（ ）接线是否发生断路和短路现象。",[533,535,537,539],{"key":20,"text":534,"correct":26},"232",{"key":24,"text":536,"correct":26},"422",{"key":28,"text":538,"correct":22},"485",{"key":31,"text":540,"correct":26},"USB",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":31,"analysis":33},964459,"在图形显示装置（CRT）中，查询历史记录可通过（ ）菜单实现。",[545,547,549,551],{"key":20,"text":546,"correct":26},"维保记录",{"key":24,"text":548,"correct":26},"设备信息",{"key":28,"text":550,"correct":26},"备份数据库",{"key":31,"text":552,"correct":22},"日志查询",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":28,"analysis":33},964460,"在消防联动控制系统中，属于受控设备的是（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":26},"手动报警按钮",{"key":24,"text":560,"correct":26},"感探测器",{"key":28,"text":562,"correct":22},"消火栓泵",{"key":31,"text":123,"correct":26},{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":24,"analysis":33},964461,"通过火灾报警控制器总线手动控制盘手动启动气体灭火，火灾报警控制器需要处于哪种状态下在才能进行手动控制（ ）。",[568,570,572,574],{"key":20,"text":569,"correct":26},"“手动允许”状态下并处于“喷洒禁止”",{"key":24,"text":571,"correct":22},"“手动允许”状态下并处于“喷洒允许”",{"key":28,"text":573,"correct":26},"“自动禁止”状态下并处于“喷洒允许”",{"key":31,"text":575,"correct":26},"“自动允许”状态下并处于“喷洒禁止”",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":24,"analysis":33},964462,"修改控制器密码，首先按下（ ）键，输入系统密码，进人系统设置菜单；选择第一项“修改密码”，屏幕上会显示出三种密码输入指示。",[580,582,583,585],{"key":20,"text":581,"correct":26},"复位",{"key":24,"text":240,"correct":22},{"key":28,"text":584,"correct":26},"取消",{"key":31,"text":413,"correct":26},[587,590,593,596,599,602],{"id":15,"name":588,"category":7,"favorite":589},"领导干部任职前廉政法规知识测试题",92,{"id":591,"name":592,"category":7,"favorite":15},595,"建筑结构与设备",{"id":594,"name":595,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":597,"name":598,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":600,"name":601,"category":7,"favorite":8},534,"BIM工程师",{"id":603,"name":601,"category":7,"favorite":8},535]