[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-39":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,39,50,2716,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},966135,3,"判断题","水流指示器的安装应在管道试压和冲洗合格后进行。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},966136,"压力开关应水平安装在通往水力警铃的管道上，且不应在安装中拆装改动。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},966137,"自动喷水灭火系统报警阀组的安装应在供水管网冲洗后、试压前进行。",[38,39],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},966138,"闭式喷头安装前在现场应进行模拟喷水试验。",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},966139,"闭式喷头进行密封性能试验的保压时间不得少于3min。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":25,"analysis":27},966140,"连接报警阀进出口的控制阀应釆用电磁阀，否则应设锁定阀位的锁具。",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},966141,"干式系统一个报警阀组控制的喷头数不宜超过600",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":25,"analysis":27},966142,"湿式喷水灭火系统由闭式喷头、管道、干式报警阀、压力气源、排气设备、供水设备组成。",[68,69],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},966143,"确定闭式喷头的动作温度，一般要求喷头的公称动作温度比环境最高温度高30℃",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},966144,"发生火灾时，湿式系统由闭式喷头探测火灾，水流指示器报告起火区域，报警阀组或稳压泵的压力开关输出启动供水泵的信号，完成系统的启动。",[80,81],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":21,"analysis":27},966145,"发现误报警时，可检查整个管网是否漏水，检查延迟器溢出孔是否堵塞或排水不畅，打开泄放试验阀可排空系统内积水或检验供水管网是否堵塞。",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},966146,"当保护区域内某处发生火灾时区域内环境温度升高，洒水喷头的热敏感元件（玻璃球）中的有机溶液发生热膨胀而产生很大的内压力，直到玻璃球外壳发生破碎，从而开启洒水喷头，并且自动启动预作用系统，发出报警信号，以达到火灾报警及控制火灾、扑灭火灾之目的。",[92,93],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":21,"analysis":27},966147,"末端试水装置的出水应釆用孔口出流的方式排入排水管道。",[98,99],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":25,"analysis":27},966148,"每半年应检查一次密封件和阀座，清除污物，如有划伤用细砂纸打磨光滑，如有破损用备件更换。同时清洗过滤器上的脏物。",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},966149,"预作用装置的功能性检测按照下列要求进行：模拟火灾探测报警，火灾报警控制器确认火灾后，自动启动预作用装置（雨淋报警阀）、排气阀入口电动阀以及消防水泵；水流指示器、压力开关动作。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},966150,"自动喷水灭火系统玻璃球洒水喷头公称动作温度68℃时，工作液色标为红色。",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},966151,"湿式系统、干式系统应在喷头动作后，直接由水流指示器连锁自动启动供水消防泵。",[122,123],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},966152,"预作用系统电磁阀启动测试至少每月进行一次检查与维护",[128,129],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},966153,"报警阀组的试水阀放水及其启动性能测试至少每季度进行一次检查与维护；分别利用系统末端试水装置、楼层试水阀和报警阀组旁的放水试验阀等测试装置进行放水试验",[134,135],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":25,"analysis":27},966154,"预作用系统火灾扑灭后，应将电磁阀关闭，使雨淋阀关闭，并排除管中的水使系统充气压力保持在0.01-0.02MPa范围内，恢复准工作状态。",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},966155,"预作用系统预作用阀是由雨淋阀和湿式报警阀上下串接而成，雨淋阀位于供水侧，湿式报警阀位于系统侧而成为预作用阀组。",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":21,"analysis":27},966156,"干式报警阀每周应压下销钮对自动排水阀进行检查，确保自动排水阀没有水或气排出。自动排水阀如有水和或气体排出，表明阀体的气阀座或水阀座泄漏，从而引起中间腔室增压，造成阀门误动作",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":25,"analysis":27},966157,"干式自动喷水灭火系统，是为了满足寒冷和高温场所安装自动喷水灭火系统的需要，在湿式系统的基础上发展起来的开式系统。",[158,159],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},966158,"ZSFZ湿式报警阀是只允许水单方向流入喷水灭火系统，并在规定的压力和流量下驱动配套部件报警的一种单向阀",[164,165],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":25,"analysis":27},966159,"湿式报警阀当系统处于伺应状态时，座圈上的沟槽小孔被阀瓣盖住封闭，通往水力警铃的报警水道畅通；当上、下压力差达到一定数值，阀瓣才开启（压差启动），水就从供水侧流向系统侧，警铃报警，灭火系统喷水。",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":21,"analysis":27},966160,"自动喷水灭火系统，当管道公称直径小于等于100mm时，应釆用螺纹连接，当管道公称直径大于100mm时，可釆用焊接或法兰连接。",[176,177],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},966161,"自动喷水灭火系统配水管道应釆用内外壁热镀锌钢管。",[182,183],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":21,"analysis":27},966162,"末端放水装置维护时，目测，观察末端放水装置的外观是否符合检查要求；观察压力表的读数有无明显偏差，比如指针在0刻度以下或在最大刻度以外。打开截止阀放水时，压力表指针无变化等。",[188,189],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},966163,"水流指示器在报警控制器上显示其故障。①首先拆开模块，检查信号线是否松动、脱落；②然后检查模块是否故障，方法参考报警系统的输入模块检修方法。",[194,195],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},966164,"水流指示器在未做放水试验时，消控室显示其已报警。首先将水流指示器的模块拆开，查看桨片的传动杆是否未复位，将传动杆来回拨动几次，将报警控制器复位，观察是否还报警。",[200,201],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":21,"analysis":27},966165,"水流指示器在末端放水试验时未报警；首先查看水流指示器的安装方向是否与水流方向一致，如果不一致，将水流指示器换个方向。",[206,207],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":21,"analysis":27},966166,"更换水流指示器时应先关闭水流指示器前端的信号阀，然后在该区域的末端放水处将管道内的水排空。",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":21,"analysis":27},966167,"水流指示器的维护时，目测，观察水流指示器外观有无碰伤；水流指示器与管道连接处有无滴水流指示器安装位置是否便于操作。",[218,219],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":21,"analysis":27},966168,"观应水流指示器的检查要求：①水流指示器的外完好，无明显碰伤，无漏水现象；②水流指示器的所在的位置应便于操作；③水流指示器动作时，报警控制器应正确显示其监管（反馈）信息。",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":25,"analysis":27},966169,"喷头溅水盘上可以挂接灯笼、广告宣传纸张（图片）。",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":25,"analysis":27},966170,"公共娱乐场所，中庭环廊，医院、疗养院的病房及治疗区域，老年、少儿、残疾人的集体活动场所，地下的商业及仓储用房应釆用特殊响应喷头。",[236,237],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":21,"analysis":27},966171,"喷头更换完毕后，应打开信号蝶阀放水试压。",[242,243],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":25,"analysis":27},966172,"宽度超过1.0米的风机风管下方增设的喷头应釆用下垂型的喷头。",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},966173,"更换喷头时用专用扳手扣住喷头项部逆时针旋转，拧下喷头；将新的喷头丝扣处缠紧生料带，用专用扳手拧紧新喷头。",[254,255],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},966174,"每周应对水压表和气压表进行检查，确保系统维持正常的水压和气压。",[260,261],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":25,"analysis":27},966175,"干式系统水流报警装置应每月试验一次，试验时打开报警试验阀，一部分水流将进入压力开关和\u002F或水力警铃，检查合格后，关闭报警试验阀。",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},966176,"每年至少进行一次报警阀正确运行验证试验，如果要求水流不超出立管高度，执行下述步骤：①关闭主控制阀；②开启主排水阀；③缓慢开启主控制阀，使其开度保持在主排水阀刚好有水流出的位置；④关闭主排水阀。",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":27},966177,"干式报警阀组充气连接管的直径，当釆用钢管时，不应小于10mm；釆用铜管时，管径不宜小于15mm。",[278,279],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":21,"analysis":27},966178,"发生火警时，湿式系统管网上的闭式洒水喷头中的热敏感元件受热爆破自动喷水湿式报警阀系统侧压力下降，在压差的作用下，阀瓣自动开启，供水侧的水流入系统侧对管网补水，整个管网处于自动喷水灭火状态。",[284,285],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":21,"analysis":27},966179,"湿式报警阀装置长期处于伺应状态，系统侧充满工作压力的水，常用于环境温度高于4℃低于70℃的场所。",[290,291],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},966180,"ZSFZ湿式报警阀为盖板型报警阀，主要由阀体、座圈和阀瓣三部分组成，整个阀体被阀瓣分成上、下两腔，上腔（系统侧）与水源相通，下腔（供水侧）与系统管网相通，在阀体中配有座圈，在座圈上，有多个通往延时器进水管的沟槽小孔。",[296,297],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":25,"analysis":27},966181,"湿式喷水灭火系统、干式喷水灭火系统的自动联动触发信号是水流指示的动作信号，由消防联动控制器按照预设逻辑完成自动灭火的控制。",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},966182,"检查自动灭火功能的方法：打开末端试水装置或打开报警阀组放水阀或消火栓放水，检查水泵能否正常启动。",[308,309],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":25,"analysis":27},966183,"预作用系统一旦发生火灾，安装在保护区感温感烟火灾探测器发出火灾报警信号。火灾报警控制器或消防控制中心，接到报警信号后发出指令打开雨淋阀上电磁阀，使雨淋阀开启，压力水流进系统侧管网，变成湿式喷水系统，同时水力警铃发出报警，压力开关动作反馈给控制中心显示管路已充水，并启动消防泵并喷水。",[314,315],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},966184,"加压开启雨淋报警阀是指平时控制腔为常压，通过向控制腔施加一定压力使其开启的雨淋报警阀。",[320,321],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},[323,327,330,333,336,339],{"id":324,"name":325,"category":7,"favorite":326},1,"领导干部任职前廉政法规知识测试题",92,{"id":328,"name":329,"category":7,"favorite":324},595,"建筑结构与设备",{"id":331,"name":332,"category":7,"favorite":324},715,"招标采购专业知识与法律法规",{"id":334,"name":335,"category":7,"favorite":324},848,"市政方向-通用基础",{"id":337,"name":338,"category":7,"favorite":8},534,"BIM工程师",{"id":340,"name":338,"category":7,"favorite":8},535]