[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-32":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":565},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,32,50,2716,[13,35,51,66,81,95,107,122,135,148,161,173,185,197,209,221,233,245,257,269,281,293,306,318,330,342,354,366,378,391,403,415,423,435,447,459,471,483,493,499,505,511,517,523,529,535,541,547,553,559],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},965782,2,"多选题","消防水泵应有以下手动控制方式（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","消控室总线启停",false,{"key":24,"text":25,"correct":26},"B","泵房就地启停",true,{"key":28,"text":29,"correct":26},"C","控制室专用线路启停",{"key":31,"text":32,"correct":26},"D","消控室多线启停","BCD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":50,"analysis":34},965783,"消防水泵控制柜面板设有电源电压、（ ）及故障的声光报警等显示。",[39,41,43,45,47],{"key":20,"text":40,"correct":22},"电阻",{"key":24,"text":42,"correct":26},"电流",{"key":28,"text":44,"correct":22},"电源频率",{"key":31,"text":46,"correct":26},"水泵启停状况",{"key":48,"text":49,"correct":22},"E","水泵转速","BD",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":65,"analysis":34},965784,"消防水泵应有（ ）功能，主备泵应有故障自投功能。",[55,57,59,61,63],{"key":20,"text":56,"correct":26},"手动启停",{"key":24,"text":58,"correct":22},"自动启停",{"key":28,"text":60,"correct":26},"手动机械启动",{"key":31,"text":62,"correct":22},"自动机械启泵",{"key":48,"text":64,"correct":22},"自检","AC",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":80,"analysis":34},965785,"建筑物内常用的电气设备和装置包括变、配电装置以及安装在装置中的低压配电和控制电器。下列属于变、配电装置防火措施的检查是（ ）。",[70,72,74,76,78],{"key":20,"text":71,"correct":26},"变压器保护",{"key":24,"text":73,"correct":26},"防止雷击措施",{"key":28,"text":75,"correct":26},"接地措施",{"key":31,"text":77,"correct":26},"过电流保护措施",{"key":48,"text":79,"correct":22},"接触器","ABCD",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":80,"analysis":34},965786,"当有减振要求时，水泵应配有减振设施。常用的减振设施有（ ）。",[85,87,89,91,93],{"key":20,"text":86,"correct":26},"橡胶隔振器",{"key":24,"text":88,"correct":26},"橡胶剪切减振器",{"key":28,"text":90,"correct":26},"阻尼弹簧隔振器",{"key":31,"text":92,"correct":26},"橡胶隔振垫",{"key":48,"text":94,"correct":22},"液压减振器",{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":97,"options":98,"answer":33,"analysis":34},965787,"消防水泵铸件外表面不应有明显的结疤、（ ）等缺陷。",[99,101,103,105],{"key":20,"text":100,"correct":22},"坠流",{"key":24,"text":102,"correct":26},"气泡",{"key":28,"text":104,"correct":26},"砂眼",{"key":31,"text":106,"correct":26},"机械性损伤",{"id":108,"libraryId":5,"type":15,"typeLabel":16,"stem":109,"options":110,"answer":121,"analysis":34},965788,"消防稳压设备由气压水罐、（ ）及附件组成。",[111,113,115,117,119],{"key":20,"text":112,"correct":22},"隔膜",{"key":24,"text":114,"correct":26},"水泵机组",{"key":28,"text":116,"correct":22},"密封",{"key":31,"text":118,"correct":26},"电控系统",{"key":48,"text":120,"correct":26},"供水管路","BDE",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":134,"analysis":34},965789,"消防电梯的井底排水设施应符合（ ）等。",[126,128,130,132],{"key":20,"text":127,"correct":26},"排水泵集水井的有效容积不应小于2m3",{"key":24,"text":129,"correct":22},"排水泵集水井的有效容积不应大于2m3",{"key":28,"text":131,"correct":22},"排水泵的排水量不应大于10L\u002Fs。",{"key":31,"text":133,"correct":26},"排水泵的排水置不应小于10L\u002Fs。","AD",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":147,"analysis":34},965790,"以下哪项不是低倍数泡沫产生器的安装质量检查内容？（ ）",[139,141,143,145],{"key":20,"text":140,"correct":26},"检查泡沬产生器的密封玻璃",{"key":24,"text":142,"correct":22},"检查泡沬产生器的进气情况",{"key":28,"text":144,"correct":26},"检查泡沬产生器的安装间距",{"key":31,"text":146,"correct":26},"检查泡沬产生器的固定措施","ACD",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":160,"analysis":34},965791,"对于压力式比例混合装置、平衡式比例混合装置、机械泵入式比例混合装置的安装质量检查，以下符合要求的有（ ）。",[152,154,156,158],{"key":20,"text":153,"correct":26},"看各组件是否在安装过程中有损坏。",{"key":24,"text":155,"correct":26},"储罐各侧的检修宽度不能小于0.7m，且操作面不能小于1.5m；",{"key":28,"text":157,"correct":26},"当泡沬液储罐上的控制阀距地面高度大于1.8m时，需要在操作面处设置操作平台或操作凳。",{"key":31,"text":159,"correct":22},"比例混合器的安装方向要与系统水流方向相反，不能反向。","ABC",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":160,"analysis":34},965792,"对于压力式比例混合装置、平衡式比例混合装置、机械泵入式比例混合装置的安装质量检查说法正确的有（ ）。",[165,167,169,171],{"key":20,"text":166,"correct":26},"查看泡沫液储罐上的铭牌标识是否齐全",{"key":24,"text":168,"correct":26},"查看比例混合装置的混合比类型是否和泡沫液的混合比相匹配",{"key":28,"text":170,"correct":26},"比例混合装置和泡沫液储罐一定要与基础固定牢固。",{"key":31,"text":172,"correct":22},"安全阀的出口应朝向操作面",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":147,"analysis":34},965793,"下列压力式比例混合装置、平衡式比例混合装置、机械泵入式比例混合装置的安装质量检查内容符合要求的有（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":26},"安全阀的出口不应朝向操作面。",{"key":24,"text":180,"correct":22},"检查压力表的安装高度是否便于开关。",{"key":28,"text":182,"correct":26},"检查阀门、法兰等管道连接处是否有渗漏。",{"key":31,"text":184,"correct":26},"各阀门是否启闭灵活，是否处于正常状态。",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":160,"analysis":34},965794,"对于低倍数泡沬产生器的安装质量检查包括（ ）等。",[189,191,193,195],{"key":20,"text":190,"correct":26},"检查泡沬产生器的外观",{"key":24,"text":192,"correct":26},"检查泡沫产生器的型号",{"key":28,"text":194,"correct":26},"检查泡沫产生器的安装间距",{"key":31,"text":196,"correct":22},"检查泡沬产生器发泡网出口情況",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":160,"analysis":34},965795,"气动驱动装置的安装应符合下列规定：（ ）",[201,203,205,207],{"key":20,"text":202,"correct":26},"驱动气瓶的支、框架或箱体应固定牢靠，并做防腐处理",{"key":24,"text":204,"correct":26},"驱动气瓶上应有标明驱动介质名称、对应防护区或保护对象名称或编号的永久性标志",{"key":28,"text":206,"correct":26},"气动驱动装置的管道安装后应做气压严密性试验，并合格。",{"key":31,"text":208,"correct":22},"气动驱动装置的管道安装后应做水压严密性试验，并合格。",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":160,"analysis":34},965796,"气动驱动装置的管道安装应符合管道布置设计要求：（ ）",[213,215,217,219],{"key":20,"text":214,"correct":26},"竖直管道应在其始端和终端设防晃支架或采用管卡固定",{"key":24,"text":216,"correct":26},"水平管道应采用管卡固定",{"key":28,"text":218,"correct":26},"管卡的间距不宜大于0.5m",{"key":31,"text":220,"correct":22},"转弯处应增设1个管卡",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":160,"analysis":34},965797,"气体灭火系统气压强度试验应遵守下列规定：（ ）",[225,227,229,231],{"key":20,"text":226,"correct":26},"试验前，必须用加压介质进行预试验，预试验压力宜为0.2MPa",{"key":24,"text":228,"correct":26},"试验时，应逐步缓慢增加压力，当压力升至试验压力的50%时，如未发现异状或泄漏，继续按试验压力的10%逐级升压，每级稳压3min，直至试验压力。保压检查管道各处无变形、无泄漏为合格",{"key":28,"text":230,"correct":26},"对气动管道，应取驱动气体储存压力",{"key":31,"text":232,"correct":22},"试验时，应以不大于0.5MPa\u002Fs的升压速率缓慢升压至试验压力，关断试验气源3min内压力下降不超过试验压力的10%为合格",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":147,"analysis":34},965799,"关于气体灭火系统启动装置气压强度试验和气密性试验的说法符合要求的是（ ）。",[237,239,241,243],{"key":20,"text":238,"correct":26},"气压强度试验时，应逐步缓慢增加压力，当压力升至试验压力的50%时，如未发现异状或泄漏，继续按试验压力的10%逐级升压，每级稳压3min，直至试验压力。保压检查管道各处无变形、无泄漏为合格",{"key":24,"text":240,"correct":22},"进行气密性试验时，应以不大于0.5MPa\u002Fs的升压速率缓慢升压至试验压力，关断试验气源5min内压力下降不超过试验压力的10%为合格",{"key":28,"text":242,"correct":26},"气压强度试验和气密性试验必须采取有效的安全措施",{"key":31,"text":244,"correct":26},"气动管道试验时应采取防止误喷射的措施",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":147,"analysis":34},965800,"灭火剂储存装置的安装要求包括：（ ）",[249,251,253,255],{"key":20,"text":250,"correct":26},"储存装置的安装位置应符合设计文件的要求",{"key":24,"text":252,"correct":22},"灭火剂储存装置安装后，泄压装置的泄压方向应朝向操作面",{"key":28,"text":254,"correct":26},"低压二氧化碳灭火系统的安全阀应通过专用的泄压管接到室外",{"key":31,"text":256,"correct":26},"储存装置上压力计、液位计、称重显示装置的安装位置应便于人员观察和操作",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":147,"analysis":34},965801,"下面符合灭火剂储存装置的安装要求的有：（ ）",[261,263,265,267],{"key":20,"text":262,"correct":26},"储存容器的支、框架应固定牢靠，并应做防腐处理",{"key":24,"text":264,"correct":22},"储存容器宜徐黑色油漆，正面应标明设计规定的灭火剂名称和储存容器的编号",{"key":28,"text":266,"correct":26},"安装集流管前应检查内腔，确保清诘",{"key":31,"text":268,"correct":26},"集流管上的泄压装置的泄压方向不应朝向操作面",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":280,"analysis":34},965802,"以下符合灭火剂储存装置安装要求的是：（ ）",[273,275,277,279],{"key":20,"text":274,"correct":26},"集流管外表面宜涂红色油漆",{"key":24,"text":276,"correct":26},"集流管应固定在支、框架上。支、框架应固定牢靠，并做防腐处理",{"key":28,"text":278,"correct":22},"连接储存容器与集流管间的单向阀的流向指示箭头应指向空气流动方向",{"key":31,"text":268,"correct":26},"ABD",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":33,"analysis":34},965803,"符合固定消防炮灭火系统手动启动功能验收要求的有：（ ）",[285,287,289,291],{"key":20,"text":286,"correct":22},"使系统电源处于接通状态，各控制装置的操作按钮处于自动状态",{"key":24,"text":288,"correct":26},"逐个按下各消防泵组的手动操作启、停按钮，观察消防泵组的动作及反馈信号情况是否正常",{"key":28,"text":290,"correct":26},"逐个按下各电控阀门的手动操作启、停按钮，观察阀门的启、闭动作及反馈信号情况是否正常",{"key":31,"text":292,"correct":26},"用手动按钮或手持式无线遥控发射装置逐个操控相对应的消防炮做俯仰和水平回转动作，观察各消防炮的动作及反馈信号是否正常",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":305,"analysis":34},965804,"固定消防炮灭火系统主、备电源的切换功能验收要求包括：（ ）",[297,299,301,303],{"key":20,"text":298,"correct":26},"系统主、备电源处于接通状态，切断主电源，备用电源应能自动投入运行",{"key":24,"text":300,"correct":26},"恢复主电源供电，主电源应能自动投入运行",{"key":28,"text":302,"correct":22},"接通控制装置电源，并使消防泵组控制装置处于自动状态",{"key":31,"text":304,"correct":22},"人工启动一台消防泵组，观察该消防泵组及相关设备动作是否正常","AB",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":160,"analysis":34},965805,"下列哪些符合固定消防炮灭火系统消防泵组功能验收要求：（ ）",[310,312,314,316],{"key":20,"text":311,"correct":26},"按系统设计要求，启动消防泵组，观察该消防泵组及相关设备动作是否正常，若正常，消防泵组在设计负荷下，连续运转不应小于2h",{"key":24,"text":313,"correct":26},"接通控制装置电源，并使消防泵组控制装置处于自动状态，人工启动一台消防泵组，观察该消防泵组及相关设备动作是否正常",{"key":28,"text":315,"correct":26},"模拟消防泵组故障，使之停泵，此时，备用消防泵组应能自动投入运行",{"key":31,"text":317,"correct":22},"消防泵组在设计负荷下，连续运转不应小于2h",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":33,"analysis":34},965806,"下面符合固定消防炮灭火系统联动控制功能验收要求的是：（ ）",[322,324,326,328],{"key":20,"text":323,"correct":22},"对设计的联动控制单元进行抽查",{"key":24,"text":325,"correct":26},"接通系统电源，使待检联动控制单元的被控设备均处于自动状态，按下对应的联动启动按钮，该单元应能按设计要求自动启动消防泵组",{"key":28,"text":327,"correct":26},"打开阀门等相关设备，直至消防炮喷射灭火剂（或水幕保护系统出水）",{"key":31,"text":329,"correct":26},"该单元设备的动作与信号反馈应符合设计要求",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":280,"analysis":34},965807,"以下符合固定消防炮灭火系统喷射功能验收试验条件要求的有（ ）：",[334,336,338,340],{"key":20,"text":335,"correct":26},"水炮和水幕保系统采用消防水进行喷射",{"key":24,"text":337,"correct":26},"泡沫炮系统的比例混合装置及泡沫液的规格应符合设计要求",{"key":28,"text":339,"correct":22},"消防泵组供水达到设计供水压力",{"key":31,"text":341,"correct":26},"干粉炮系统的干粉型号、规格、储量和氮气瓶组的规格、压力应符合系统设计要求",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":33,"analysis":34},965809,"固定消防炮灭火系统喷射功能试验结果符合要求的有：（ ）",[346,348,350,352],{"key":20,"text":347,"correct":22},"干粉炮系统自启动至喷出干粉的时间不应大于5min",{"key":24,"text":349,"correct":26},"水炮、泡沫炮、干粉炮的水平、俯仰回转角应符合设计要求，带直流喷雾转换功能的消防水炮的喷雾角应符合设计要求",{"key":28,"text":351,"correct":26},"水炮系统和泡沫炮系统自启动至喷出水或泡沬的时间不应大于5min",{"key":31,"text":353,"correct":26},"泡沬炮系统的泡沬比例、混合装置提供的混合液的混合比应符合设计要求",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":280,"analysis":34},965810,"以下符合电气火灾监控系统监控设备的安装要求的有：（ ）",[358,360,362,364],{"key":20,"text":359,"correct":26},"设备应安装牢固，不应倾斜；",{"key":24,"text":361,"correct":26},"落地安装时：设备底边宜高出地（楼）面0.1-0.2m；",{"key":28,"text":363,"correct":22},"采用壁挂方式安装时；其主显示屏高度宜为1.3-1.5m，其靠近门轴的侧面距墙不应小于0.5m，正面操作距离不应小于1.2m",{"key":31,"text":365,"correct":26},"安装在轻质墙上时，应采取加固措施",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":280,"analysis":34},965811,"以下符合电气火灾监控系统监控设备引入线缆要求的有：（ ）",[370,372,374,376],{"key":20,"text":371,"correct":26},"配线应整齐，不宜交叉，并应固定牢靠",{"key":24,"text":373,"correct":26},"线缆芯线的端部，均应标明编号，并与图样一致，字迹应清晰且不易褪色",{"key":28,"text":375,"correct":22},"端子板的每个接线端，接线不得超过1根",{"key":31,"text":377,"correct":26},"线缆应留有不小于200mm的余量",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":390,"analysis":34},965812,"以下哪些是电气火灾监控系统监控设备蓄电池（如有）安装要求：（ ）",[382,384,386,388],{"key":20,"text":383,"correct":22},"设备的主电源应有明显的永久性标识，并应直接与消防电源连接，严禁使用电源插头",{"key":24,"text":385,"correct":22},"设备与其外接备用电源（如有）之间应直接连接",{"key":28,"text":387,"correct":26},"设备自带电池需进行现场安装时，蓄电池规格、型号、容量应符合设计文件的规定",{"key":31,"text":389,"correct":26},"蓄电池安装应符合产品使用说明书的要求","CD",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":280,"analysis":34},965813,"关于电气火灾监控设备报警功能符合要求的有：（ ）",[395,397,399,401],{"key":20,"text":396,"correct":26},"监控设备应能对指示灯、显示器和音响器件进行功能自检",{"key":24,"text":398,"correct":26},"监控设备应根据不同的使用对象设置不同的操作级别",{"key":28,"text":400,"correct":22},"监控设备应能自动消除报警声信号",{"key":31,"text":402,"correct":26},"监控设备的连接、探测器的监测区域恢复正常，监控设备应能对监控设备的报警状态复位，消除监控设备的声、光报警信号",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":160,"analysis":34},965814,"符合剩余流式电气火灾监控探测器监控报警功能要求的有（ ）。",[407,409,411,413],{"key":20,"text":408,"correct":26},"探测器监测区域的剩余电流达到报警设定值时，探测器的报警确认灯应在30s内点亮并保持",{"key":24,"text":410,"correct":26},"监控设备应发出监控报警声、光信号，并记录报警时间",{"key":28,"text":412,"correct":26},"监控设备应显示发出报警信号部件的地址注释信息",{"key":31,"text":414,"correct":22},"探测器监测区域的温度达到报警设定值时，探测器的报警确认灯应在40s内点亮并保持",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":33,"analysis":34},965815,"符合测温式电气火灾监控探测器监控报警功能要求的有（ ）。",[419,420,421,422],{"key":20,"text":408,"correct":22},{"key":24,"text":410,"correct":26},{"key":28,"text":412,"correct":26},{"key":31,"text":414,"correct":26},{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":160,"analysis":34},965816,"以下哪些符合电气火灾监控系统监控探测器安装要求？（ ）",[427,429,431,433],{"key":20,"text":428,"correct":26},"在探测器周围应适当留出更换和标定的空间",{"key":24,"text":430,"correct":26},"剩余电流式探测器负载侧的中性线不应与其他回路共用，且不应重复接地",{"key":28,"text":432,"correct":26},"测温式探测器应采用产品配套固定装置固定在保护对象上",{"key":31,"text":434,"correct":22},"线缆应留有不小于150mm的余量",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":160,"analysis":34},965817,"以下哪些符合电气火灾监控系统传感器安装要求？（ ）",[439,441,443,445],{"key":20,"text":440,"correct":26},"传感器与裸带电导体应保证安全距离，金属外壳的传感器应有安全接地",{"key":24,"text":442,"correct":26},"传感器应独立支承或固定，安装牢固，并应采取防潮、防腐蚀等措施",{"key":28,"text":444,"correct":26},"传感器输出回路的连接线，应使用截面积不小于1.0mm2的双绞铜芯导线，并应留有不小于150mm的余量，其端部应有明显标识",{"key":31,"text":446,"correct":22},"传感器的安装可以破坏被监控线路的完整性，可以增加线路接点",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":305,"analysis":34},965818,"符合电气火灾监控设备故障报警功能的是（ ）。",[451,453,455,457],{"key":20,"text":452,"correct":26},"监控设备与现场部件之间的连线断路时，监控设备应在100s内显示故障部件的地址注释信息",{"key":24,"text":454,"correct":26},"监控设备与现场部件之间的连线短路时，监控设备应在100s内显示故障部件的地址注释信息",{"key":28,"text":456,"correct":22},"探测器发出报警信号后，监控设备应在10s内发出监控报警声、光信号，并记录报警时间监控设备应显示发出报警信号部件的地址注释信息",{"key":31,"text":458,"correct":22},"监控设备应能手动消除报警声信号",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":160,"analysis":34},965819,"《消防法》规定，同一建筑物由两个以上单位管理或者使库的，应当明确各方的消防安全责任，并确定责任人对共用的疏散通道、（ ）进行统一管理。",[463,465,467,469],{"key":20,"text":464,"correct":26},"安全出口",{"key":24,"text":466,"correct":26},"建筑消防设施",{"key":28,"text":468,"correct":26},"消防车通道",{"key":31,"text":470,"correct":22},"办公设施",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":160,"analysis":34},965820,"单元独立系统是用一套灭火剂储存装置保护一个防护区的系统，它与防护区一一对应，一般设置由单元独立系统原因主要有（ ）。",[475,477,479,481],{"key":20,"text":476,"correct":26},"防护区在位置上相对独立",{"key":24,"text":478,"correct":26},"离其他防护区较远",{"key":28,"text":480,"correct":26},"几个相邻的防护区有同时失火的危险",{"key":31,"text":482,"correct":22},"只有该区域需要设置气体灭火系统",{"id":484,"libraryId":5,"type":485,"typeLabel":486,"stem":487,"options":488,"answer":492,"analysis":34},965821,3,"判断题","集中火灾报警控制器可查询集中火灾报警控制器或分消防控制室内控制器上传的火警、联动、监管、故障、屏蔽等实时信息。",[489,491],{"key":20,"text":490,"correct":22},"正确",{"key":24,"text":492,"correct":26},"错误",{"id":494,"libraryId":5,"type":485,"typeLabel":486,"stem":495,"options":496,"answer":492,"analysis":34},965822,"各厂家的火灾报警控制器信息显示形式及查询方法不同。",[497,498],{"key":20,"text":490,"correct":22},{"key":24,"text":492,"correct":26},{"id":500,"libraryId":5,"type":485,"typeLabel":486,"stem":501,"options":502,"answer":490,"analysis":34},965823,"在集中火灾报警控制器上通过查看每条报警信息的“控制器号”“回路号”和“设备编码”内容，可以确定具体的报警点位。",[503,504],{"key":20,"text":490,"correct":26},{"key":24,"text":492,"correct":22},{"id":506,"libraryId":5,"type":485,"typeLabel":486,"stem":507,"options":508,"answer":492,"analysis":34},965824,"如果“控制器号\"部分带有“本机”字样则是区域火灾报警控制器上传的信息，带有“网络”字样则是集中火灾报警控制器配接部件的报警信息。",[509,510],{"key":20,"text":490,"correct":22},{"key":24,"text":492,"correct":26},{"id":512,"libraryId":5,"type":485,"typeLabel":486,"stem":513,"options":514,"answer":492,"analysis":34},965825,"对于水泵等主消防控制室和分消防控制室各自的重要消防设备，可釆用对共用消防设备直接手动控制和对共用消防设备跨区控制的方式实现。",[515,516],{"key":20,"text":490,"correct":22},{"key":24,"text":492,"correct":26},{"id":518,"libraryId":5,"type":485,"typeLabel":486,"stem":519,"options":520,"answer":490,"analysis":34},965826,"分消防控制室的火灾报警控制器通过直接手动控制单元连接重要消防设备，主消防控制室的集中火灾报警控制器需要通过跨区发送指令，实现手动控制功能。在集中控制器上首先要确定连接消防设备的分控制器号、直接手动控制单元号及分组号，然后通过集中火灾报警控制器的操作面板输入后实现手动控制。",[521,522],{"key":20,"text":490,"correct":26},{"key":24,"text":492,"correct":22},{"id":524,"libraryId":5,"type":485,"typeLabel":486,"stem":525,"options":526,"answer":492,"analysis":34},965827,"当集中火灾报警控制器处于某一高等级状态显示时，应能通过自动操作查询其他低等级状态信息，并且各状态信息不应交替显示。",[527,528],{"key":20,"text":490,"correct":22},{"key":24,"text":492,"correct":26},{"id":530,"libraryId":5,"type":485,"typeLabel":486,"stem":531,"options":532,"answer":492,"analysis":34},965828,"集中火灾报警控制器的当前报警信息显示按火灾报警与启动（反馈）、监管报警、故障报警、屏蔽状态及其他状态顺序由低至高排列信息显示等级，高等级的状态信息优先显示，低等级状态信息显示不应影响高等级状态信息显示。",[533,534],{"key":20,"text":490,"correct":22},{"key":24,"text":492,"correct":26},{"id":536,"libraryId":5,"type":485,"typeLabel":486,"stem":537,"options":538,"answer":492,"analysis":34},965829,"如果“控制器号”部分带有“网络”字样集中火灾报警控制器配接部件的报警信息。",[539,540],{"key":20,"text":490,"correct":22},{"key":24,"text":492,"correct":26},{"id":542,"libraryId":5,"type":485,"typeLabel":486,"stem":543,"options":544,"answer":492,"analysis":34},965830,"釆用字母（符）—数字显示器时，当显示区域不足以显示全部故障信息时，应循坏显示。",[545,546],{"key":20,"text":490,"correct":22},{"key":24,"text":492,"correct":26},{"id":548,"libraryId":5,"type":485,"typeLabel":486,"stem":549,"options":550,"answer":492,"analysis":34},965831,"当发生故障时，传输设备应在60s内发出与火灾报警和手动报警有明显区别的本机故障声、光信号，并指示出类型，本机故障声信号应能手动消除，再有故障发生时，应能再启动；本机故障光信号应保持至故障排除。",[551,552],{"key":20,"text":490,"correct":22},{"key":24,"text":492,"correct":26},{"id":554,"libraryId":5,"type":485,"typeLabel":486,"stem":555,"options":556,"answer":490,"analysis":34},965832,"传输设备自动传输釆集到的火灾报警控制器输出的火警信号失败后，可使用传输设备的手动报警功能。",[557,558],{"key":20,"text":490,"correct":26},{"key":24,"text":492,"correct":22},{"id":560,"libraryId":5,"type":485,"typeLabel":486,"stem":561,"options":562,"answer":492,"analysis":34},965833,"传输设备应在1s内将来自火灾报警控制器的信息传送给消防远程监控中。",[563,564],{"key":20,"text":490,"correct":22},{"key":24,"text":492,"correct":26},[566,570,573,576,579,582],{"id":567,"name":568,"category":7,"favorite":569},1,"领导干部任职前廉政法规知识测试题",92,{"id":571,"name":572,"category":7,"favorite":567},595,"建筑结构与设备",{"id":574,"name":575,"category":7,"favorite":567},715,"招标采购专业知识与法律法规",{"id":577,"name":578,"category":7,"favorite":567},848,"市政方向-通用基础",{"id":580,"name":581,"category":7,"favorite":8},534,"BIM工程师",{"id":583,"name":581,"category":7,"favorite":8},535]