[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-30":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":599},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,30,50,2716,[13,35,48,61,74,87,99,110,121,133,145,156,168,176,188,198,209,220,229,240,250,262,274,290,302,317,331,341,353,366,378,390,403,415,426,438,450,462,473,485,496,508,516,524,533,544,556,564,574,587],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},965680,2,"多选题","广播控制器与火灾报警控制器显示“支线故障”，消防应急广播系统无法正常启动，可能是什么原因?（ ）",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","广播模块接线错误",true,{"key":24,"text":25,"correct":22},"B","广播模块到扬声器之间线路短路或断路",{"key":27,"text":28,"correct":29},"C","广播模块到功率放大器之间线路短路或断路",false,{"key":31,"text":32,"correct":29},"D","广播干线接地","AB","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},965681,"检测发现，广播控制器与火灾报警控制器显示“干线故障”，消防应急广播系统无法正常启动，请问该如何维修？（ ）",[39,41,43,45],{"key":20,"text":40,"correct":22},"检查修复广播模块至功率放大器之间的连线，进行断开或连接修复",{"key":24,"text":42,"correct":29},"检查修复广播模块至扬声器之间的连线",{"key":27,"text":44,"correct":22},"检查广播模块接线，重新连接",{"key":31,"text":46,"correct":22},"排除干线接地","ACD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},965682,"消防电话系统线路常见故障一般有（ ）。",[52,54,56,58],{"key":20,"text":53,"correct":22},"分机线路故障",{"key":24,"text":55,"correct":22},"插孔线路故障",{"key":27,"text":57,"correct":22},"总线故障",{"key":31,"text":59,"correct":29},"干线故障","ABC",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},965683,"消防电话总机显示“总线故障”，消防电话系统所有分机、插孔均无法与总机通信，这是什么原因造成的？（ ）",[65,67,69,71],{"key":20,"text":66,"correct":29},"该分机与电话总机线路断开",{"key":24,"text":68,"correct":29},"该插孔与电话总机线路断开",{"key":27,"text":70,"correct":22},"电话系统总干线短路、断路",{"key":31,"text":72,"correct":22},"某个电话分机或电话插孔损坏，端子短路导致整条线路短路","CD",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":86,"analysis":34},965684,"电气火灾监控系统常见故障原因有：（ ）。",[78,80,82,84],{"key":20,"text":79,"correct":22},"设备自身故障",{"key":24,"text":81,"correct":22},"电气火灾监控系统通信线路故障",{"key":27,"text":83,"correct":29},"模块故障",{"key":31,"text":85,"correct":22},"系统部分回路故障","ABD",{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":60,"analysis":34},965685,"电气火灾监控系统设备故障可能的原因有（ ）。",[91,93,95,97],{"key":20,"text":92,"correct":22},"监控设备未开启",{"key":24,"text":94,"correct":22},"监控设备损坏",{"key":27,"text":96,"correct":22},"探测器损坏",{"key":31,"text":98,"correct":29},"监控设备线路未连接",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":60,"analysis":34},965686,"电气火灾监控系统线路故障的原因包括（ ）。",[103,105,107,109],{"key":20,"text":104,"correct":22},"监控设备与探测器线路未连接",{"key":24,"text":106,"correct":22},"探测总线短路",{"key":27,"text":108,"correct":22},"探测总线断路",{"key":31,"text":92,"correct":29},{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":120,"analysis":34},965687,"电气火灾监控系统线路故障的原因有（ ）。",[114,116,117,118],{"key":20,"text":115,"correct":29},"探测总线缺相",{"key":24,"text":106,"correct":22},{"key":27,"text":108,"correct":22},{"key":31,"text":119,"correct":22},"传感组件线路断路或短路","BCD",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":60,"analysis":34},965688,"电气火灾监控系统线路故障如何处理？（ ）",[125,127,129,131],{"key":20,"text":126,"correct":22},"线路重新连接，进行测试",{"key":24,"text":128,"correct":22},"检查线路，排除短路后重新进行测试",{"key":27,"text":130,"correct":22},"检查线路，排除断路后重新进行测试",{"key":31,"text":132,"correct":29},"检查线路，排除接地后重新进行测试",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":60,"analysis":34},965689,"消防应急照明和疏散指示系统的常见故障一般有（ ）等。",[137,139,141,143],{"key":20,"text":138,"correct":22},"应急照明控制器故障",{"key":24,"text":140,"correct":22},"应急照明集中电源故障",{"key":27,"text":142,"correct":22},"应急照明配电箱故障",{"key":31,"text":144,"correct":29},"主机故障",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":120,"analysis":34},965690,"消防应急照明和疏散指示系统的常见故障一般有应急照明控制器故障、应急照明集中电源故障、（ ）等。",[149,151,152,154],{"key":20,"text":150,"correct":29},"探测器故障",{"key":24,"text":142,"correct":22},{"key":27,"text":153,"correct":22},"消防应急灯具故障",{"key":31,"text":155,"correct":22},"系统线路故障",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":33,"analysis":34},965691,"对消防应急照明和疏散指示系统进行检测时发现，应急照明控制器无显示或显示不正常，可能的原因是（ ）。",[160,162,164,166],{"key":20,"text":161,"correct":22},"灯板、显示板损坏",{"key":24,"text":163,"correct":22},"灯板、显示板接线不良",{"key":27,"text":165,"correct":29},"主电源接线不良",{"key":31,"text":167,"correct":29},"主电源熔丝烧断",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":73,"analysis":34},965692,"对消防应急照明和疏散指示系统进行检测时发现，应急照明控制器显示“主电故障”，可能的原因是（ ）。",[172,173,174,175],{"key":20,"text":161,"correct":29},{"key":24,"text":163,"correct":29},{"key":27,"text":165,"correct":22},{"key":31,"text":167,"correct":22},{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":60,"analysis":34},965693,"消防应急照明和疏散指示系统检测时发现，应急照明控制器不打印，可能的原因是（ ）。",[180,182,184,186],{"key":20,"text":181,"correct":22},"打印选顶未设置",{"key":24,"text":183,"correct":22},"打印机接线不良",{"key":27,"text":185,"correct":22},"打印机卡纸",{"key":31,"text":187,"correct":29},"打印机电源故障",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":73,"analysis":34},965694,"消防应急照明和疏散指示系统检测时发现，应急照明控制器按键无反应，可能的原因是（ ）。",[192,193,194,196],{"key":20,"text":161,"correct":29},{"key":24,"text":163,"correct":29},{"key":27,"text":195,"correct":22},"按键板与主板接线不良",{"key":31,"text":197,"correct":22},"按键板损坏",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":73,"analysis":34},965695,"消防应急照明和疏散指示系统检测时发现，应急照明集中电源无显示或显示不正常，可能的原因是（ ）。",[202,204,205,207],{"key":20,"text":203,"correct":29},"灯板、显示板桢坏",{"key":24,"text":163,"correct":29},{"key":27,"text":206,"correct":22},"主板损坏",{"key":31,"text":208,"correct":22},"电源板、转接板接线不良",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":219,"analysis":34},965696,"消防应急照明和疏散指示系统检测时发现，应急照明集中电源显示“主电故障”，可能的原因是（ ）。",[213,214,215,217],{"key":20,"text":165,"correct":29},{"key":24,"text":167,"correct":22},{"key":27,"text":216,"correct":22},"充电回路断路或短路",{"key":31,"text":218,"correct":29},"蓄电池（组）损坏","BC",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":73,"analysis":34},965697,"消防应急照明和疏散指示系统检测时发现，应急照明集中电源显示“备电故障”，可能的原因是（ ）。",[224,226,227,228],{"key":20,"text":225,"correct":29},"主电源接线不良，",{"key":24,"text":167,"correct":29},{"key":27,"text":216,"correct":22},{"key":31,"text":218,"correct":22},{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":33,"analysis":34},965698,"消防应急照明和疏散指示系统检测时发现，应急照明集中电源输出回路故障，可能的原因是（ ）。",[233,235,237,238],{"key":20,"text":234,"correct":22},"输出回路断路、短路",{"key":24,"text":236,"correct":22},"输出回路过载保护",{"key":27,"text":216,"correct":29},{"key":31,"text":239,"correct":29},"蓄电池（组）損坏",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":73,"analysis":34},965699,"应急照明集中电源不能控制灯具应急启动、标志灯指示状态改变的原因是（ ）。",[244,245,246,248],{"key":20,"text":234,"correct":29},{"key":24,"text":236,"correct":29},{"key":27,"text":247,"correct":22},"集中电源主控板损坏",{"key":31,"text":249,"correct":22},"回路板损坏",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":60,"analysis":34},965700,"可扑救木材火灾的灭火器是（ ）。",[254,256,258,260],{"key":20,"text":255,"correct":22},"水基型",{"key":24,"text":257,"correct":22},"泡沫",{"key":27,"text":259,"correct":22},"磷酸铵盐干粉",{"key":31,"text":261,"correct":29},"洁净气体",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":219,"analysis":34},965701,"水泵启动后工作电流偏大。水泵发热的原因可能是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":29},"空气开关额定工作电流过大",{"key":24,"text":269,"correct":22},"三相不平衡大于10%",{"key":27,"text":271,"correct":22},"配置电动机功率小",{"key":31,"text":273,"correct":29},"热继电器动作",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":289,"analysis":34},965702,"（ ）火灾属于B类火灾。",[278,280,282,284,286],{"key":20,"text":279,"correct":22},"汽油",{"key":24,"text":281,"correct":29},"木材",{"key":27,"text":283,"correct":29},"天然气",{"key":31,"text":285,"correct":22},"石蜡",{"key":287,"text":288,"correct":22},"E","乙酵","ADE",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":73,"analysis":34},965703,"（ ）灭火器可同时扑救 A、 B、C类和带电火灾。",[294,296,297,298,300],{"key":20,"text":295,"correct":29},"水",{"key":24,"text":257,"correct":29},{"key":27,"text":259,"correct":22},{"key":31,"text":299,"correct":22},"手提式洁净气体",{"key":287,"text":301,"correct":29},"碳酸氢钠干粉",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":316,"analysis":34},965704,"灭火的基本原理可分为（ ）。",[306,308,310,312,314],{"key":20,"text":307,"correct":22},"冷却",{"key":24,"text":309,"correct":22},"窒息",{"key":27,"text":311,"correct":22},"隔离",{"key":31,"text":313,"correct":22},"化学抑制",{"key":287,"text":315,"correct":29},"链式反应","ABCD",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":330,"analysis":34},965705,"灭火救援中使用的灭火剂有（ ）灭火剂等。",[321,322,324,326,328],{"key":20,"text":295,"correct":22},{"key":24,"text":323,"correct":22},"泡沫灭火剂",{"key":27,"text":325,"correct":29},"一氧化炭",{"key":31,"text":327,"correct":22},"干粉灭火剂",{"key":287,"text":329,"correct":22},"二氧化碳","ABDE",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":316,"analysis":34},965706,"常见的几类灭火剂有（ ）等。",[335,336,337,338,339],{"key":20,"text":295,"correct":22},{"key":24,"text":323,"correct":22},{"key":27,"text":329,"correct":22},{"key":31,"text":327,"correct":22},{"key":287,"text":340,"correct":29},"—氣化磙",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":47,"analysis":34},965707,"根据灭火器类型不同，下列灭火器从出厂日期算起到规定年限应报废的是（ ）。",[345,347,349,351],{"key":20,"text":346,"correct":22},"水基型灭火器6年",{"key":24,"text":348,"correct":29},"干粉灭火器8年",{"key":27,"text":350,"correct":22},"洁净气体灭火器10年",{"key":31,"text":352,"correct":22},"二氧化碳灭火器12年",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":365,"analysis":34},965708,"B类火灾是指（ ）物质火灾。",[357,359,361,363],{"key":20,"text":358,"correct":29},"气休",{"key":24,"text":360,"correct":22},"液体",{"key":27,"text":362,"correct":29},"金属",{"key":31,"text":364,"correct":22},"可熔化的固体","BD",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":86,"analysis":34},965709,"E类火灾场所应选择（ ）等灭火器灭火。",[370,372,374,376],{"key":20,"text":371,"correct":22},"磷酸铵盐干粉灭火器",{"key":24,"text":373,"correct":22},"碳酸氢钠干粉灭火器",{"key":27,"text":375,"correct":29},"装有金属喇叭喷桶的二氧化碳灭火器",{"key":31,"text":377,"correct":22},"洁净气体灭火器",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":86,"analysis":34},965710,"灭火器的报废年限为10年的是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"手提式（贮压式）干粉灭火器",{"key":24,"text":385,"correct":22},"手提式（储气瓶式）干粉灭火器",{"key":27,"text":387,"correct":29},"推车式二氧化碳灭火器",{"key":31,"text":389,"correct":22},"推车式（储气瓶式）干粉灭火器",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":402,"analysis":34},965711,"水型灭火器使用温度范围是（ ）",[394,396,398,400],{"key":20,"text":395,"correct":22},"不加防冻剂+5℃～+55℃",{"key":24,"text":397,"correct":29},"不加防冻剂-5℃～+4℃",{"key":27,"text":399,"correct":22},"添加防冻剂-10℃～+55℃",{"key":31,"text":401,"correct":29},"添加防冻剂-20℃～+4℃","AC",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":120,"analysis":34},965712,"下列防火防爆措施中采用隔绝空气、破坏燃烧爆炸助燃条件的是（ ）。",[407,409,411,413],{"key":20,"text":408,"correct":29},"加强通风，降低可燃气体或蒸气、粉尘在空间的浓度",{"key":24,"text":410,"correct":22},"密闭有可燃介质的容器、设备",{"key":27,"text":412,"correct":22},"充装氮气",{"key":31,"text":414,"correct":22},"充装惰性介质，保护有易燃易甩物品的容器、设备。",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":47,"analysis":34},965713,"关于电气火灾监控系统线路故障的维修方法正确的有（ ）。",[419,421,423,424],{"key":20,"text":420,"correct":22},"检查传感组件线路，排除短路或断路后重新进行测试，保持稳固连接",{"key":24,"text":422,"correct":29},"更换损坏线路，开机",{"key":27,"text":126,"correct":22},{"key":31,"text":425,"correct":22},"检查线路连接处是否有松动倩况，排除后进行测试",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":73,"analysis":34},965714,"可燃气体探测报警系统出现某只探测器掉线故障，请问如何维修？（ ）",[430,432,434,436],{"key":20,"text":431,"correct":29},"检查该回路供电\u002F通信连接线是否断开，连接好该回路供电\u002F通信连接线路",{"key":24,"text":433,"correct":29},"用万用表检查探测器回路供电\u002F通信线路是否存在短路情況，排查短路故障",{"key":27,"text":435,"correct":22},"用万用表检查该报测器供电\u002F通信连接线，连接好该探测器供电\u002F通信连接线",{"key":31,"text":437,"correct":22},"如探测器仍然无法恢复正常工作状态，则更换该探测器",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":33,"analysis":34},965715,"可燃气体探测报警系统的常见线路故障按故障出现的部位可以分为（ ）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"系统设备内部的连接线路故障",{"key":24,"text":445,"correct":22},"可燃气体报警控制器和可燃气体探测器之间的连接线路故障",{"key":27,"text":447,"correct":29},"可燃气体报警控制器设备故障",{"key":31,"text":449,"correct":29},"可燃气体探测器损坏",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":47,"analysis":34},965716,"可燃气体探测系统线路常见故障包括（ ）。",[454,456,458,460],{"key":20,"text":455,"correct":22},"可燃气体报警控制器无显示故障",{"key":24,"text":457,"correct":29},"某一报警区域可燃气体探测器全部掉线故障",{"key":27,"text":459,"correct":22},"某一回路可燃气体探测器全部掉线故障",{"key":31,"text":461,"correct":22},"某只探测器掉线故障",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":60,"analysis":34},965717,"检测时发现，可燃气体报警控制器无显示，该故障可能的原因是（ ）。",[466,468,470,472],{"key":20,"text":467,"correct":22},"未连接主电源电源线",{"key":24,"text":469,"correct":22},"未连接备用电源线",{"key":27,"text":471,"correct":22},"熔断器动作（损坏）",{"key":31,"text":96,"correct":29},{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":33,"analysis":34},965718,"检测时发现，可燃气体报警控制器无显示，需如何排除该故障？（ ）",[477,479,481,483],{"key":20,"text":478,"correct":22},"检查保险、线路倩况",{"key":24,"text":480,"correct":22},"复位\u002F更换熔断器",{"key":27,"text":482,"correct":29},"连接好该探测器供电\u002F通信连接线",{"key":31,"text":484,"correct":29},"更换探测器",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":60,"analysis":34},965719,"可燃气体探测报警系统出现某一回路可燃气体探测器全部掉线故障，请问如何维修？（ ）",[489,490,492,494],{"key":20,"text":431,"correct":22},{"key":24,"text":491,"correct":22},"用万用表检查探测器回路供电\u002F通信线路是否存在短路情况，排查短路故障",{"key":27,"text":493,"correct":22},"利用兆欧表（揺表）检测该回路供电\u002F通信线路与大地之间的接地电阻。",{"key":31,"text":495,"correct":29},"阻值大于产品说明书中的绝缘要求则为接地故障，利用分段法排查回路线路接地点并修复接地故障",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":402,"analysis":34},965720,"可燃气体探测报警系统出现某只探测器掉线故障，原因可能是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"该探测器损坏",{"key":24,"text":503,"correct":29},"探测器通信线路短路或者断开",{"key":27,"text":505,"correct":22},"该探测器连接线断开",{"key":31,"text":507,"correct":29},"该回路出现接地故障",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":33,"analysis":34},965721,"消防应急照明和疏散指示系统检测时发现，应急照明配电箱无显示或显示不正常，可能的原因是（ ）。",[512,513,514,515],{"key":20,"text":206,"correct":22},{"key":24,"text":208,"correct":22},{"key":27,"text":161,"correct":29},{"key":31,"text":163,"correct":29},{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":219,"analysis":34},965722,"消防应急照明和疏散指示系统检测时发现，应急照明配电箱输出回路故障，可能的原因是（ ）。",[520,521,522,523],{"key":20,"text":206,"correct":29},{"key":24,"text":234,"correct":22},{"key":27,"text":236,"correct":22},{"key":31,"text":167,"correct":29},{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":402,"analysis":34},965723,"消防应急照明和疏散指示系统检测时发现，应急照明配电箱不能控制灯具应急启动、标志灯指示状态改变，可能的原因是（ ）。",[528,530,531,532],{"key":20,"text":529,"correct":22},"配电箱主控板损坏",{"key":24,"text":234,"correct":29},{"key":27,"text":249,"correct":22},{"key":31,"text":167,"correct":29},{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":365,"analysis":34},965724,"照明灯具设置部位的地面水平照度不满足要求的原因有（ ）。",[537,539,541,542],{"key":20,"text":538,"correct":29},"灯具损坏",{"key":24,"text":540,"correct":22},"灯具灯罩污染",{"key":27,"text":249,"correct":29},{"key":31,"text":543,"correct":22},"灯具光源效率降低",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":33,"analysis":34},965725,"控制器显示集中电源或应急照明配电箱配装的多个“灯具故障”的原因包括（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":22},"集中电源或应急照明配电箱输出端子接线不良",{"key":24,"text":551,"correct":22},"集中电源或应急照明配电箱输出回路总线短路、断路",{"key":27,"text":553,"correct":29},"应急照明控制器与火灾报警控制器、输出模块间线路接线不良",{"key":31,"text":555,"correct":29},"应急照明控制器与火灾报警控制器、输出模块间通信线路断路",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":73,"analysis":34},965726,"应急照明控制器不能自动控制系统设备应急启动、标志灯指示状态改变的原因是：（ ）。",[560,561,562,563],{"key":20,"text":549,"correct":29},{"key":24,"text":551,"correct":29},{"key":27,"text":553,"correct":22},{"key":31,"text":555,"correct":22},{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":73,"analysis":34},965727,"控制器显示某一“灯具故障”的原因有（ ）。",[568,569,570,572],{"key":20,"text":549,"correct":29},{"key":24,"text":551,"correct":29},{"key":27,"text":571,"correct":22},"灯具与集中电源或应急照明配电箱间接线不良",{"key":31,"text":573,"correct":22},"灯具与回路总线间接线短路、断路",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":586,"analysis":34},965728,"当采样管道布置形式为垂直采样时，每（ ）温差间隔或（ ）间隔（取最小者）应设置一个采样孔。",[578,580,582,584],{"key":20,"text":579,"correct":22},"2℃",{"key":24,"text":581,"correct":29},"3℃",{"key":27,"text":583,"correct":29},"2m",{"key":31,"text":585,"correct":22},"3m","AD",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":60,"analysis":34},965729,"采样孔的直径应根据（ ）等因素确定，并应符合设计文件和产品使用说明书的要求；采样孔需要现场加工时，应采用专用打孔工具。",[591,593,595,597],{"key":20,"text":592,"correct":22},"采样管的长度",{"key":24,"text":594,"correct":22},"敷设方式",{"key":27,"text":596,"correct":22},"采样孔的数量",{"key":31,"text":598,"correct":29},"采样孔的直径",[600,604,607,610,613,616],{"id":601,"name":602,"category":7,"favorite":603},1,"领导干部任职前廉政法规知识测试题",92,{"id":605,"name":606,"category":7,"favorite":601},595,"建筑结构与设备",{"id":608,"name":609,"category":7,"favorite":601},715,"招标采购专业知识与法律法规",{"id":611,"name":612,"category":7,"favorite":601},848,"市政方向-通用基础",{"id":614,"name":615,"category":7,"favorite":8},534,"BIM工程师",{"id":617,"name":615,"category":7,"favorite":8},535]