[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":558},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,3,50,2716,[13,34,45,54,64,72,82,94,106,117,129,139,150,159,167,179,191,203,215,227,239,251,260,269,281,293,301,313,325,337,349,360,368,378,390,402,414,423,431,443,455,467,477,487,499,511,520,532,540,549],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},964311,1,"单选题","在火灾报警控制器上，（ ）灯亮，表示声光警报器发生故障。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","反馈",false,{"key":24,"text":25,"correct":22},"B","警报器消音指示",{"key":27,"text":28,"correct":29},"C","声光警报器故障指示",true,{"key":31,"text":32,"correct":22},"D","声光警报器屏蔽指示","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},964312,"在火灾报警控制器上，（ ）灯亮，表示系统中存在处于自检状态的设备。",[38,39,41,43],{"key":20,"text":21,"correct":22},{"key":24,"text":40,"correct":22},"自动允许",{"key":27,"text":42,"correct":22},"备电工作",{"key":31,"text":44,"correct":29},"自检",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":24,"analysis":33},964313,"在火灾报警控制器上，（ ）灯亮，表示当满足联动条件后，系统自动对联动设备进行联动操作。",[49,50,51,52],{"key":20,"text":21,"correct":22},{"key":24,"text":40,"correct":29},{"key":27,"text":42,"correct":22},{"key":31,"text":53,"correct":22},"启动",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":31,"analysis":33},964314,"在火灾报警控制器上，（ ）灯亮，表示控制器已经发出启动命令。",[58,60,62,63],{"key":20,"text":59,"correct":22},"火警",{"key":24,"text":61,"correct":22},"主电工作",{"key":27,"text":42,"correct":22},{"key":31,"text":53,"correct":29},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":20,"analysis":33},964315,"在火灾报警控制器上，（ ）灯亮，表示控制器检测到外接被控设备的反馈信号。",[68,69,70,71],{"key":20,"text":21,"correct":29},{"key":24,"text":53,"correct":22},{"key":27,"text":61,"correct":22},{"key":31,"text":42,"correct":22},{"id":73,"libraryId":5,"type":15,"typeLabel":16,"stem":74,"options":75,"answer":20,"analysis":33},964316,"在火灾报警控制器上，（ ）灯亮，表示控制器检测到外部设备（探测器、模块或火灾显示盘）有故障，或控制器本身出现故障。",[76,78,79,80],{"key":20,"text":77,"correct":29},"做障",{"key":24,"text":61,"correct":22},{"key":27,"text":42,"correct":22},{"key":31,"text":81,"correct":22},"屏蔽",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},964317,"住宅建筑内设置的应急广播应能接受联动控制或由手动火灾报警按钮信号直接控制进行广播，每台扬声器覆盖的楼层不应超过（ ）层。",[86,88,90,92],{"key":20,"text":87,"correct":22},"2",{"key":24,"text":89,"correct":29},"3",{"key":27,"text":91,"correct":22},"4",{"key":31,"text":93,"correct":22},"5",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},964318,"触发首层的消防电梯迫降按钮，检查消防电梯能否下降至首层，并发出反馈信号，此时其他楼层按钮不能呼叫消防电梯，只能在（ ）内控制。",[98,100,102,104],{"key":20,"text":99,"correct":22},"首层前室",{"key":24,"text":101,"correct":29},"轿厢",{"key":27,"text":103,"correct":22},"消防控制室",{"key":31,"text":105,"correct":22},"值班室",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},964319,"火灾报警控制器应能在接到火灾报警信号后（ ）秒钟发出火灾报警声、光信号。",[110,111,113,115],{"key":20,"text":93,"correct":22},{"key":24,"text":112,"correct":29},"10",{"key":27,"text":114,"correct":22},"15",{"key":31,"text":116,"correct":22},"30",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":20,"analysis":33},964320,"消防应急广播的单次语音播放时间宜为（ ）。",[121,123,125,127],{"key":20,"text":122,"correct":29},"8s～20s",{"key":24,"text":124,"correct":22},"10s～30s",{"key":27,"text":126,"correct":22},"8s～30s",{"key":31,"text":128,"correct":22},"10s～20s",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":24,"analysis":33},964321,"火灾报警制器应有可靠的工作接地，当釆用专用接地装置时，接地电阻值不应大于（ ）Ω。",[133,135,136,137],{"key":20,"text":134,"correct":22},"l",{"key":24,"text":91,"correct":29},{"key":27,"text":112,"correct":22},{"key":31,"text":138,"correct":22},"20",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":24,"analysis":33},964322,"火灾报警控制器每个回路导线对地的绝缘电阻不应小于（ ）MΩ。",[143,145,146,148],{"key":20,"text":144,"correct":22},"10O",{"key":24,"text":138,"correct":29},{"key":27,"text":147,"correct":22},"50",{"key":31,"text":149,"correct":22},"100",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":27,"analysis":33},964323,"在检测火灾报警控制器火警优先功能时，在故障状态下，使任一非故障部位的探测器发出火灾报警信号，控制器应在（ ）秒内发出火灾报警信号。",[154,155,156,158],{"key":20,"text":89,"correct":22},{"key":24,"text":116,"correct":22},{"key":27,"text":157,"correct":29},"60",{"key":31,"text":149,"correct":22},{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":27,"analysis":33},964324,"火灾报警控制器备用电源自动充电检验要求及方法为：主电源恢复后，备用电源自动切除并进入充电状态。将主电断开，使控制器处于备电工作状态监视30分钟左右，记录此时备电电压值，然后恢复主电，（ ）分钟后记录备电电压值，通过比较，确认备电是否具有自充电功能。",[163,164,165,166],{"key":20,"text":89,"correct":22},{"key":24,"text":93,"correct":22},{"key":27,"text":112,"correct":29},{"key":31,"text":116,"correct":22},{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":31,"analysis":33},964325,"每个报警区域内的模块宜相对集中设置在本报警区域内的金属模块箱中，未集中设置的模块附近应有尺寸不小于（ ）的标识。",[171,173,175,177],{"key":20,"text":172,"correct":22},"15cm×15cm",{"key":24,"text":174,"correct":22},"20cm×20cm",{"key":27,"text":176,"correct":22},"8cm×8cm",{"key":31,"text":178,"correct":29},"l0cm×l0cm",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":31,"analysis":33},964326,"火灾声光警报器应设置在每个楼层的楼梯口、消防电梯前室、建筑内部拐角等处的明显部位，且不宜与（ ）设置在同一面墙上。",[183,185,187,189],{"key":20,"text":184,"correct":22},"消防应急照明灯",{"key":24,"text":186,"correct":22},"发光疏散指示标志",{"key":27,"text":188,"correct":22},"消防疏散指示标志",{"key":31,"text":190,"correct":29},"安全出口指示标志灯具",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":27,"analysis":33},964327,"消防联动控制器应能按（ ）的控制逻辑向各相关的受控设备发出联动控制信号，并接受相关设备的联动反馈信号。",[195,197,199,201],{"key":20,"text":196,"correct":22},"规定",{"key":24,"text":198,"correct":22},"火灾自动报警系统",{"key":27,"text":200,"correct":29},"设定",{"key":31,"text":202,"correct":22},"预定",{"id":204,"libraryId":5,"type":15,"typeLabel":16,"stem":205,"options":206,"answer":24,"analysis":33},964328,"消防控制室内值班人员接到现场火灾确认信息后，必须立即将火灾报警联动控制开关转入（ ）状态。",[207,209,211,213],{"key":20,"text":208,"correct":22},"手动",{"key":24,"text":210,"correct":29},"自动",{"key":27,"text":212,"correct":22},"电动",{"key":31,"text":214,"correct":22},"机械手动",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":20,"analysis":33},964329,"集中控制型消防应急照明系统的联动应由（ ）联动应急照明控制器实现。",[219,221,223,225],{"key":20,"text":220,"correct":29},"消防控制器",{"key":24,"text":222,"correct":22},"动力照明系统",{"key":27,"text":224,"correct":22},"普通照明系统",{"key":31,"text":226,"correct":22},"集中照明系统",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":27,"analysis":33},964330,"消防专用电话、电话插孔、带电话插孔的手动报警按钮宜安装在明显、便于操作的位置；当在墙面上安装时，其底边距地（楼）面高度宜为（ ）m",[231,233,235,237],{"key":20,"text":232,"correct":22},"1.1-1.3",{"key":24,"text":234,"correct":22},"l.l-1.5",{"key":27,"text":236,"correct":29},"l.3-1.5",{"key":31,"text":238,"correct":22},"1.3-1.8",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":31,"analysis":33},964331,"火灾警报器设置在墙上时，其底边距地面高度应（ ）m。",[243,245,247,249],{"key":20,"text":244,"correct":22},"小于1.5",{"key":24,"text":246,"correct":22},"大于1.5",{"key":27,"text":248,"correct":22},"小于2.2",{"key":31,"text":250,"correct":29},"大于2.2",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":20,"analysis":33},964332,"在火灾报警后经逻辑确认（或人工确认），消防联动控制器应在（ ）s内按设定的控制逻辑准确发出联动控制信号给相应的消防设备。",[255,256,257,259],{"key":20,"text":89,"correct":29},{"key":24,"text":93,"correct":22},{"key":27,"text":258,"correct":22},"8",{"key":31,"text":112,"correct":22},{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":24,"analysis":33},964333,"模拟火灾报警，检查消防控制设备能否手动和自动控制电梯回落首层，并接收反馈信号，测从首层到顶层的运行时间是否超过（ ）s",[264,265,266,267],{"key":20,"text":116,"correct":22},{"key":24,"text":157,"correct":29},{"key":27,"text":149,"correct":22},{"key":31,"text":268,"correct":22},"120",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":27,"analysis":33},964334,"消防控制室内的图形显示装置、火灾报警控制器、消防联动控制设备，其功能既相互独立，又相互关联，准确把控其功能是充分发挥消防控制室监控与管理作用的关键。下列消防控制室图形显示装置，不符合国家工程技术的是（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":22},"釆用中文标注和中文界面的消防控制室图形显示装置",{"key":24,"text":276,"correct":22},"其界面对角线长度不得小于430mm",{"key":27,"text":278,"correct":29},"100s内能够显示输入的火灾报警信号和反馈信号的状态信息",{"key":31,"text":280,"correct":22},"100s内能够显示其他输入信号的状态信息",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":24,"analysis":33},964335,"控制器供电后，电源指示灯应常亮，当关掉主电源开关时，控制器应报出（ ），并能自动切换到备用电源供电。",[285,287,289,291],{"key":20,"text":286,"correct":22},"“主电工作”",{"key":24,"text":288,"correct":29},"“主电故障”",{"key":27,"text":290,"correct":22},"“主电正常”",{"key":31,"text":292,"correct":22},"“主电异常”",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":31,"analysis":33},964336,"消防电梯的井底设置排水设施，排水井的容量不小于2立方米，排水泵的排水量不小于（ ）L\u002FS。",[297,298,299,300],{"key":20,"text":87,"correct":22},{"key":24,"text":89,"correct":22},{"key":27,"text":93,"correct":22},{"key":31,"text":112,"correct":29},{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":31,"analysis":33},964337,"火灾自动报警设备的“自检键”的功能（ ）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"检查建筑物内的各种探头是否处于正常工作状态",{"key":24,"text":308,"correct":22},"检查建筑物内的各种消防设备是否处于正常工作状态",{"key":27,"text":310,"correct":22},"检查建筑物内的消防管线是否处于正常工作状态",{"key":31,"text":312,"correct":29},"检查火灾报警控制器本身性能是否处于正常工作状态",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":31,"analysis":33},964338,"消防控制室值班人员接到报警信号后，应迅速到达报警点确认，如未发生火情，应查明（ ）釆取相应措施，并认真做好记录。",[317,319,321,323],{"key":20,"text":318,"correct":22},"故障原因",{"key":24,"text":320,"correct":22},"周围情况",{"key":27,"text":322,"correct":22},"报警人员",{"key":31,"text":324,"correct":29},"报警原因",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":24,"analysis":33},964339,"用减光值为11.5dB的减光片遮挡光路，探测器应在（ ）内发出火警报警信号。",[329,331,333,335],{"key":20,"text":330,"correct":22},"20s",{"key":24,"text":332,"correct":29},"30s",{"key":27,"text":334,"correct":22},"40s",{"key":31,"text":336,"correct":22},"60s",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":27,"analysis":33},964340,"发生火灾时，火灾报警控制器接收到同一防护区域内两个及以上独立的（ ）火灾探测器或一个（ ）火灾探测器和一个手动火灾报警按钮的报警信号，火灾报警控制器发出雨淋阀组开启的联动触发信号，由消防联动控制器联动控制该防护区的雨淋阀的开启，雨淋阀压力开关动作后直接联动雨淋消防泵的启动。",[341,343,345,347],{"key":20,"text":342,"correct":22},"感烟，感温",{"key":24,"text":344,"correct":22},"感烟，感烟",{"key":27,"text":346,"correct":29},"感温，感温",{"key":31,"text":348,"correct":22},"感温，感烟",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":27,"analysis":33},964341,"发生火警时，火灾报警控制器所连接的声光警报器将发出报警声，提示现场人员有火警存在，如果值班人员发现不是真实火警时，可以首先对其进行（ ）操作。",[353,355,356,358],{"key":20,"text":354,"correct":22},"联动",{"key":24,"text":44,"correct":22},{"key":27,"text":357,"correct":29},"消音",{"key":31,"text":359,"correct":22},"复位",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":27,"analysis":33},964342,"监管报警功能检查：触发与输入模块连接的监管信号，控制器应能在（ ）s内发出与火灾报警信号有明显区别的监管报警声、光信号。",[364,365,366,367],{"key":20,"text":116,"correct":22},{"key":24,"text":157,"correct":22},{"key":27,"text":149,"correct":29},{"key":31,"text":268,"correct":22},{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":20,"analysis":33},964343,"在火灾报警系统中，直接控制盘发出命令信号后（ ）灯亮，如果10s内未收到反馈信号，该灯闪烁。",[372,373,375,376],{"key":20,"text":53,"correct":29},{"key":24,"text":374,"correct":22},"工作",{"key":27,"text":21,"correct":22},{"key":31,"text":377,"correct":22},"系统",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":24,"analysis":33},964344,"在自动状态下，使火灾探测器报警，联动控制器接收火灾报警信号，向输入输出模块发出启动信号，启动总指示灯亮，同时应在控制器上显示，以下哪一项说法不正确（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"指示启动输入输出模块的名称",{"key":24,"text":385,"correct":29},"指示启动输入输出模块的参数",{"key":27,"text":387,"correct":22},"指示启动输入输出模块的启动时间",{"key":31,"text":389,"correct":22},"指示启动输入输出模块的启动总数。",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":27,"analysis":33},964345,"应将喷淋消防泵控制柜的启动、停止按钮专用线路直接连接至设置在消防控制室内消防联动控制器的（ ）。",[394,396,398,400],{"key":20,"text":395,"correct":22},"总线控制盘",{"key":24,"text":397,"correct":22},"总线回路",{"key":27,"text":399,"correct":29},"手动直接控制盘",{"key":31,"text":401,"correct":22},"警报输出端口",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":20,"analysis":33},964346,"（ ）是在消防联动控制器预设联动逻辑公式，当预设的逻辑条件满足时，在自动允许状态下，消防联动控制器通过模块按照预设的逻辑自动完成受控设备的联动控制。",[406,408,410,412],{"key":20,"text":407,"correct":29},"自动总线联动",{"key":24,"text":409,"correct":22},"手动总线联动",{"key":27,"text":411,"correct":22},"手动直控制",{"key":31,"text":413,"correct":22},"面板操作",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":31,"analysis":33},964347,"在火灾报警控制器上，（ ）灯亮，表示控制器检测到了外部设备的监管报警信号。",[418,419,420,421],{"key":20,"text":59,"correct":22},{"key":24,"text":53,"correct":22},{"key":27,"text":21,"correct":22},{"key":31,"text":422,"correct":29},"监管",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":31,"analysis":33},964348,"在火灾报警控制器上，（ ）灯亮，表示系统中存在被屏蔽的声光警报器。",[427,428,429,430],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":22},{"key":27,"text":28,"correct":22},{"key":31,"text":32,"correct":29},{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":20,"analysis":33},964349,"除（ ）键外，其他功能键被按下后，都会显示一个要求输入密码的画面。",[435,437,439,441],{"key":20,"text":436,"correct":29},"消音、记录检查",{"key":24,"text":438,"correct":22},"启动、停止",{"key":27,"text":440,"correct":22},"屏蔽、取消屏蔽",{"key":31,"text":442,"correct":22},"自检、系统设置",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":24,"analysis":33},964350,"应（ ）对干式报警阀组气压进行检查，确保系统维持正常的气压。",[447,449,451,453],{"key":20,"text":448,"correct":22},"每日",{"key":24,"text":450,"correct":29},"每周",{"key":27,"text":452,"correct":22},"每半月",{"key":31,"text":454,"correct":22},"每月",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":31,"analysis":33},964352,"城市隧道室内消火栓系统管道内的消防供水压力应保证用水量达到最大时，最低压力不应小于（ ）Mpa。",[459,461,463,465],{"key":20,"text":460,"correct":22},"0.15",{"key":24,"text":462,"correct":22},"0.2",{"key":27,"text":464,"correct":22},"0.25",{"key":31,"text":466,"correct":29},"0.3",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":27,"analysis":33},964353,"建筑高度大于27米且小于54米的高层住宅建筑的室内消火栓的栓口动压不应小于（ ）。",[471,472,473,475],{"key":20,"text":460,"correct":22},{"key":24,"text":464,"correct":22},{"key":27,"text":474,"correct":29},"0.35",{"key":31,"text":476,"correct":22},"0.45",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":24,"analysis":33},964354,"消防水泵、防烟和排烟风机的控制设备当釆用总线编码模块控制时，还应在消防控制时设置（ ）直接控制装置。",[481,482,483,485],{"key":20,"text":210,"correct":22},{"key":24,"text":208,"correct":29},{"key":27,"text":484,"correct":22},"自动和手动",{"key":31,"text":486,"correct":22},"自动或手动",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":31,"analysis":33},964355,"独立式火灾探测器宜选择电池供电时间不少于（ ）的独立式火灾探测报警器。",[491,493,495,497],{"key":20,"text":492,"correct":22},"6个月",{"key":24,"text":494,"correct":22},"l年",{"key":27,"text":496,"correct":22},"2年",{"key":31,"text":498,"correct":29},"3年",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":31,"analysis":33},964356,"探测气体密度与空气密度相当时，可燃气体探测器可设置在被保护空间的（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"中间",{"key":24,"text":506,"correct":22},"顶部",{"key":27,"text":508,"correct":22},"底部",{"key":31,"text":510,"correct":29},"中间位或顶部",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":24,"analysis":33},964357,"可燃气体探测器报警性能：当被监视区域的可燃气体浓度达到报警设定值时，探测器应输出报警信号，探测器的低限报警响应时间不应超过（ ）。",[515,516,517,518],{"key":20,"text":330,"correct":22},{"key":24,"text":332,"correct":29},{"key":27,"text":336,"correct":22},{"key":31,"text":519,"correct":22},"100s",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":24,"analysis":33},964358,"探测比重小于空气的可燃气体探测器，其安装高度应高出释放源（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":22},"0.3-0.6m",{"key":24,"text":527,"correct":29},"0.5-2m",{"key":27,"text":529,"correct":22},"0.3-2m",{"key":31,"text":531,"correct":22},"0.5-0.6m",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},964359,"探测比重大于空气的可燃气体探测器，其安装高度应距地坪（或楼地板）（ ）。",[536,537,538,539],{"key":20,"text":525,"correct":29},{"key":24,"text":527,"correct":22},{"key":27,"text":529,"correct":22},{"key":31,"text":531,"correct":22},{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":31,"analysis":33},964360,"吸气式感烟火灾探测器当釆样管道釆用毛细管布置方式时，毛细管长度不宜超过（ ）m。",[544,545,547,548],{"key":20,"text":138,"correct":22},{"key":24,"text":546,"correct":22},"16",{"key":27,"text":112,"correct":22},{"key":31,"text":91,"correct":29},{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":27,"analysis":33},964361,"城市交通隧道出入口以及隧道内每隔（ ）m处，应设置手动火灾报警按钮。",[553,555,556,557],{"key":20,"text":554,"correct":22},"25",{"key":24,"text":116,"correct":22},{"key":27,"text":147,"correct":29},{"key":31,"text":157,"correct":22},[559,562,565,568,571,574],{"id":15,"name":560,"category":7,"favorite":561},"领导干部任职前廉政法规知识测试题",92,{"id":563,"name":564,"category":7,"favorite":15},595,"建筑结构与设备",{"id":566,"name":567,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":569,"name":570,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":572,"name":573,"category":7,"favorite":8},534,"BIM工程师",{"id":575,"name":573,"category":7,"favorite":8},535]