[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-29":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":612},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,29,50,2716,[13,35,48,61,73,86,99,111,121,133,145,157,168,181,192,202,214,226,238,250,262,272,284,295,306,317,329,341,352,363,375,383,395,405,416,428,440,452,468,482,497,510,522,532,541,550,562,574,587,599],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},965630,2,"多选题","雨淋自动喷水灭火系统使用一段时间后阀瓣自动开启该如何解决（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","维修火灾自动报警系统",true,{"key":24,"text":25,"correct":22},"B","疏通节流孔板",{"key":27,"text":28,"correct":22},"C","关闭或维修电磁阀",{"key":30,"text":31,"correct":32},"D","检査水力警铃的配件，配齐组件",false,"ABC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},965631,"预作用自动喷水灭火系统测试不报警的原因是（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":22},"水力警铃进水口处喷嘴被堵塞",{"key":24,"text":42,"correct":32},"水质过脏，有细小杂质进入复位装置密封面",{"key":27,"text":44,"correct":22},"未配置铃锤或者铃锤卡死",{"key":30,"text":46,"correct":22},"消防用水中的杂质堵塞了报警管道上过滤器的滤网","ACD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},965632,"雨淋自动喷水灭火系统不能复位或阀瓣不能关闭是什么原因（ ）。",[52,54,56,58],{"key":20,"text":53,"correct":22},"复位步骤不对",{"key":24,"text":55,"correct":22},"水质过脏，有细小杂质进入复位装罝密封面",{"key":27,"text":57,"correct":32},"未将系统惻管网内的余水排尽",{"key":30,"text":59,"correct":32},"消防用水水质存在问题，如有杂物等","AB",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":33,"analysis":34},965633,"下面哪些是灭火控制系统常见的问题？（ ）",[65,67,69,71],{"key":20,"text":66,"correct":22},"灭火系统设置条件发生变化",{"key":24,"text":68,"correct":22},"压力容器没有定期检测",{"key":27,"text":70,"correct":22},"灭火剂质量问题",{"key":30,"text":72,"correct":32},"线路连接问题",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":85,"analysis":34},965634,"某单位使用气体灭火系统，以下描述有问题的是（ ）。",[77,79,81,83],{"key":20,"text":78,"correct":32},"防护区改造后，其可燃物灭火浓度或防护区容积发生变化，该单位及时变更了系统设计",{"key":24,"text":80,"correct":22},"防护区域功能发生变化，不宜设置气体灭火系统，没有及时变更系统设计",{"key":27,"text":82,"correct":22},"灭火系统产品标准已经废止（如悬挂式哈龙“1211”产品），没有及时变更系统设计",{"key":30,"text":84,"correct":22},"《二氧化碳灭火系统设计规范》（GB-50193）修订后，未及时变更二氧化碳灭火系统的有人或经常有人的防护区","BCD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},965635,"自动跟踪定位射流灭火系统灭火装置不出水或射程小、水流分散，需要如何处理？（ ）",[90,92,94,96],{"key":20,"text":91,"correct":22},"检查自动控制阀和检修阀是否正常打开",{"key":24,"text":93,"correct":22},"检查供水管网和灭火装置流道是否有异物堵塞",{"key":27,"text":95,"correct":22},"排除阀门故障",{"key":30,"text":97,"correct":22},"清除堵塞异物","ABCD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":110,"analysis":34},965636,"如何排除自动跟踪定位射流灭火系统灭火装置射流打不准目标的故障？（ ）",[103,105,107,108],{"key":20,"text":104,"correct":22},"检查探测装置是否存在故障",{"key":24,"text":106,"correct":22},"检查探测装置参数设置是否正确",{"key":27,"text":93,"correct":32},{"key":30,"text":109,"correct":22},"维修或更换故障部件","ABD",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":110,"analysis":34},965637,"喷洒型自动射流灭火装置不出水或水量小，排除故障的措施有（ ）。",[115,116,118,119],{"key":20,"text":91,"correct":22},{"key":24,"text":117,"correct":22},"检查供水管通内是否有异物堵塞",{"key":27,"text":93,"correct":32},{"key":30,"text":120,"correct":22},"排除阀门故障，清除堵塞异物",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":33,"analysis":34},965638,"对于固定消防炮灭火系统控制装置的描述正确的有（ ）。",[125,127,129,131],{"key":20,"text":126,"correct":22},"主机瘫痪：检查系统供电及主机硬件，维修或更换损坏设备",{"key":24,"text":128,"correct":22},"无法操作及控制：检查通信是否正常，再对线路进行检查，维修故障",{"key":27,"text":130,"correct":22},"无法控制消防炮动作：检查控制主机是否存在故障，维修或更换损坏设备；再检查系统电气线路是否存在故障，排除线路故障",{"key":30,"text":132,"correct":32},"无法打开和关闭控制阀：检查控制主机、控制阀及电源是否存在故障，维修或更换故障部件。不可能是系统电气电路故障，不需检查",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":33,"analysis":34},965639,"固定消防炮灭火系统控制主机无法打开和关闭控制阀，如何维修？（ ）。",[137,139,141,143],{"key":20,"text":138,"correct":22},"检查控制主机、控制阀及电源是否存在故障",{"key":24,"text":140,"correct":22},"检查系统电气电路是否存在故障",{"key":27,"text":142,"correct":22},"排除线路故障",{"key":30,"text":144,"correct":32},"检查控制主机是否存在故障",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":33,"analysis":34},965640,"固定消防炮灭火系统控制主机无法打开和关闭控制阀，可能是哪些部位出现故障？（ ）",[149,151,153,155],{"key":20,"text":150,"correct":22},"控制主机",{"key":24,"text":152,"correct":22},"控制阀",{"key":27,"text":154,"correct":22},"电源",{"key":30,"text":156,"correct":32},"通信线路",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":33,"analysis":34},965641,"固定消防炮灭火系统控制主机无法控制消防炮动作该如何处理？（ ）",[161,162,164,166],{"key":20,"text":144,"correct":22},{"key":24,"text":163,"correct":22},"维修或更换损坏设备",{"key":27,"text":165,"correct":22},"再检查系统电气线路是否存在故障",{"key":30,"text":167,"correct":32},"检查通信是否正常",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":180,"analysis":34},965642,"固定消防炮灭火系统控制装置中，消防泵组电气控制柜的常见故障包括（ ）。",[172,174,176,178],{"key":20,"text":173,"correct":32},"现场和远程状态无法切换",{"key":24,"text":175,"correct":32},"无法打开和关闭控制阀",{"key":27,"text":177,"correct":22},"无法启动消防水泵",{"key":30,"text":179,"correct":22},"无法实现主、备泵自动切换","CD",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":47,"analysis":34},965643,"固定消防炮灭火系统控制装置中，现场控制箱的常见故障包括：（ ）等。",[185,187,189,191],{"key":20,"text":186,"correct":22},"钥匙锁发生故障或密码锁失灵，无法解锁",{"key":24,"text":188,"correct":32},"主机瘫痪",{"key":27,"text":190,"correct":22},"无法远程启动消防水泵",{"key":30,"text":175,"correct":22},{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":47,"analysis":34},965644,"固定消防炮灭火系统控制装置中，控制主机的常见故障包括（ ）等。",[196,197,199,201],{"key":20,"text":188,"correct":22},{"key":24,"text":198,"correct":32},"通信发生故障",{"key":27,"text":200,"correct":22},"无法控制消防炮动作",{"key":30,"text":175,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":110,"analysis":34},965645,"泡沬比例混合装置无法形成或不能按比例形成泡沬混合液，正确的处理方法有（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"检查泄漏部位，确保密封良好，必要时更换泄漏部件",{"key":24,"text":209,"correct":22},"检查平衡阀，更换损坏部件，必要时更换整个平衡阀",{"key":27,"text":211,"correct":32},"检査损坏的压缩机，更换损坏的部件，必要时更换整个压缩机",{"key":30,"text":213,"correct":22},"更换已变质的泡沬液",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":85,"analysis":34},965646,"泡沫产生装置无法发泡或发泡不正常的原因有（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":32},"泡沫液因储存环境不符合要求.失效变质",{"key":24,"text":221,"correct":22},"泡沫产生装置吸气口被杂物堵塞，导致发泡不正常",{"key":27,"text":223,"correct":22},"外浮顶储罐泡沫导流累喷射口被杂物堵塞，导致泡沬无法正常喷射",{"key":30,"text":225,"correct":22},"低倍数泡沬产生器密封玻璃密封不严或损坏，导致储罐内可燃液体蒸气外泄",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":33,"analysis":34},965647,"关于预作用自动喷水灭火系统预作用装置故障描述正确的有（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"气体平稳补偿功能失效会导致预作用装置误报警",{"key":24,"text":233,"correct":22},"管道内有大量空气会导致预作用装置间歇报警",{"key":27,"text":235,"correct":22},"水中杂质导致阀瓣关闭不严会导致预作用装置一直报警",{"key":30,"text":237,"correct":32},"末端试水装置阀门未关或关闭不严会导致预作用装置间歇报警",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":33,"analysis":34},965648,"预作用自动喷水灭火系统出现预作用装置一直报警的故障该如何排除（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":22},"检査胶垫或阀瓣",{"key":24,"text":245,"correct":22},"关闭末端试水装置阀门",{"key":27,"text":247,"correct":22},"用水冲洗或清理杂质",{"key":30,"text":249,"correct":32},"检査补气孔",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":110,"analysis":34},965649,"预作用自动喷水灭火系统的常见故障有（ ）。",[254,256,258,260],{"key":20,"text":255,"correct":22},"自动滴水阀长期渗漏",{"key":24,"text":257,"correct":22},"预作用装置开启后不报警",{"key":27,"text":259,"correct":32},"电磁阀不动作",{"key":30,"text":261,"correct":22},"预作用装置误报警",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":33,"analysis":34},965650,"以下哪些是雨淋自动喷水灭火系统的常见故障（ ）。",[266,267,269,270],{"key":20,"text":255,"correct":22},{"key":24,"text":268,"correct":22},"预作用自动喷水灭火系统测试不报警",{"key":27,"text":259,"correct":22},{"key":30,"text":271,"correct":32},"压力表读数不在正常范围",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":33,"analysis":34},965651,"雨淋自动喷水灭火系统电磁阀不动作如何解决（ ）。",[276,278,280,282],{"key":20,"text":277,"correct":22},"检査联动控制启动倌号线路",{"key":24,"text":279,"correct":22},"检查电磁阀实际输入功率是否达到额定功率要求，并联设置的每台雨淋阀都应进行检测",{"key":27,"text":281,"correct":22},"联系维修更换电磁阀",{"key":30,"text":283,"correct":32},"关闭电磁阀",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":60,"analysis":34},965652,"预作用自动喷水灭火系统传动管喷头堵塞的原因是（ ）。",[288,289,291,293],{"key":20,"text":59,"correct":22},{"key":24,"text":290,"correct":22},"管道过滤器不能正常工作",{"key":27,"text":292,"correct":32},"阀瓶损坏或胶垫脱落",{"key":30,"text":294,"correct":32},"末端试水装置阀门未关或关闭不严",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":33,"analysis":34},965653,"雨淋自动喷水灭火系统自动滴水阀长期渗漏的原因有（ ）。",[299,301,303,305],{"key":20,"text":300,"correct":22},"橡胶密封件变形损坏",{"key":24,"text":302,"correct":22},"阀瓣与阀瓣座之间有杂物",{"key":27,"text":304,"correct":22},"未将系统侧管网内的余水排尽",{"key":30,"text":59,"correct":32},{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":85,"analysis":34},965654,"如何排除雨淋自动喷水灭火系统雨淋阀阀瓣渗漏的故障（ ）。",[310,311,313,315],{"key":20,"text":21,"correct":32},{"key":24,"text":312,"correct":22},"消除阀座与阀瓣密封面处的异物",{"key":27,"text":314,"correct":22},"清除阀座松动处并进行紧固",{"key":30,"text":316,"correct":22},"更换新的阀座或阀瓣",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":33,"analysis":34},965655,"自动跟踪定位射流灭火系统的常见故障有（ ）。",[321,323,325,327],{"key":20,"text":322,"correct":22},"消防控制室远程手动操作灭火装置上、下、左、右、直流\u002F喷雾不动作",{"key":24,"text":324,"correct":22},"现场控制箱操作灭火装置上、下、左、右、直流\u002F喷雾不动作",{"key":27,"text":326,"correct":22},"控制灭火装置上下动作，左右不动作",{"key":30,"text":328,"correct":32},"火灾报警控制器不报警",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":98,"analysis":34},965656,"对于自动跟踪定位射流灭火系统的下列现象有问题的是（ ）。",[333,335,337,339],{"key":20,"text":334,"correct":22},"灭火装置上、下、左、右、直流\u002F喷雾动作卡阻、迟缓",{"key":24,"text":336,"correct":22},"灭火装置无法自动扫描",{"key":27,"text":338,"correct":22},"灭火装置不出水或射程小、水流分散",{"key":30,"text":340,"correct":22},"灭火装置射流打得准目标",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":33,"analysis":34},965657,"检测发现，消防控制室远程手动操作灭火装置上、下、左、右、直流\u002F喷雾不动作，以下描述正确的有（ ）。",[345,347,349,350],{"key":20,"text":346,"correct":22},"先检查远程通信是否存在故障",{"key":24,"text":348,"correct":22},"再逐步检查控制主机，信号处理器、灭火装置动作机构等是否存在故障",{"key":27,"text":109,"correct":22},{"key":30,"text":351,"correct":32},"检查灭火装置动作机构，维修或更换故障部件",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":47,"analysis":34},965658,"检测发现，自动跟踪定位射流灭火系统灭火装置无法自动扫描需要如何处理？（ ）",[356,358,360,362],{"key":20,"text":357,"correct":22},"先检查系统控制主机参数设置是否错误",{"key":24,"text":359,"correct":32},"先检查信号处理器是否存在故障，再检查灭火装置动作机构等是否存在故障",{"key":27,"text":361,"correct":22},"再检查信号处理器、灭火装置是否存在故障",{"key":30,"text":109,"correct":22},{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":33,"analysis":34},965659,"关于固定消防炮灭火系统现场控制箱的说法正确的有（ ）。",[367,369,371,373],{"key":20,"text":368,"correct":22},"钥匙锁发生故障或密码锁失灵，无法解锁：维修设备或更换面板",{"key":24,"text":370,"correct":22},"通信发生故障：检查现场控制箱是否存在故障，维修或更换故障部件",{"key":27,"text":372,"correct":22},"无法打开和关闭控制阀：检查现场控制箱是否存在故障，维修或更换故障部件",{"key":30,"text":374,"correct":32},"现场和远程状态无法切换：维修设备或更换面板",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":33,"analysis":34},965660,"当固定消防炮灭火系统现场控制箱出现（ ）故障时，应检查现场控制箱是否存在故障，维修或更换故障部件。",[379,380,381,382],{"key":20,"text":173,"correct":22},{"key":24,"text":175,"correct":22},{"key":27,"text":177,"correct":22},{"key":30,"text":186,"correct":32},{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":110,"analysis":34},965661,"关于固定消防炮灭火系统无线遥控器的说法正确的有（ ）。",[387,389,391,393],{"key":20,"text":388,"correct":22},"遥控器按键无反应或反应不灵敏：检查电池电量是否过低，检查按键面板是否存在故障。更换电池，维修按键面板",{"key":24,"text":390,"correct":22},"无法选择消防炮：检查无线遥控器是否存在故障，维修或更换故障部件",{"key":27,"text":392,"correct":32},"无法控制消防炮动作：先检查控制主机是否存在故障，再检查无线遥控器是否存在故障，维修或更换故障部件",{"key":30,"text":394,"correct":22},"无法打开和关闭控制阀：检查无线遥控器是否存在故障，维修或更换故障部件",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":60,"analysis":34},965662,"关于固定消防炮灭火系统消防泵组电气控制柜的说法正确的有（ ）。",[399,401,403,404],{"key":20,"text":400,"correct":22},"无法启动消防水泵：检查消防泵组电气控制柜和电气线路、消防水泵驱动电动机是否存在故障，维修或更换故障部件",{"key":24,"text":402,"correct":22},"无法实现主、备泵自动切换：检查消防泵组电气控制柜和电气线路是否存在故障，维修或更换故障部件",{"key":27,"text":372,"correct":32},{"key":30,"text":374,"correct":32},{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":33,"analysis":34},965663,"固定消防炮灭火系统消防泵组电气控制柜无法启动消防水泵时，需要排除哪些部位的故障？（ ）",[409,411,413,415],{"key":20,"text":410,"correct":22},"消防泵组电气控制柜",{"key":24,"text":412,"correct":22},"电气线路",{"key":27,"text":414,"correct":22},"消防水泵驱动电动机",{"key":30,"text":150,"correct":32},{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":33,"analysis":34},965664,"按规定应予以报废处理的灭火器是（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":22},"筒体有锡焊、铜焊或补焊等修补痕迹的灭火器",{"key":24,"text":423,"correct":22},"筒体明显变形，机械损伤严严重的",{"key":27,"text":425,"correct":22},"器头存在裂纹、无泄压机构等缺陷的",{"key":30,"text":427,"correct":32},"维修2次以上的",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":85,"analysis":34},965665,"下列属于灭火器外观检查的是（ ）。",[432,434,436,438],{"key":20,"text":433,"correct":32},"灭火器的铭牌应朝外，器头宜向上",{"key":24,"text":435,"correct":22},"灭火器铭牌上关于灭火剂、驱动气体的种类、充装压力、总质量、灭火级别、制造厂名和生产日期或维修日期等标志及操作说明应齐全",{"key":27,"text":437,"correct":22},"灭火器的；部件应齐全，无松动、脱落和损伤",{"key":30,"text":439,"correct":22},"灭火器喷射软管应完好，无明显龟裂，喷嘴不堵塞",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":60,"analysis":34},965666,"灭火器的维修期限。出厂期满三年首次维修以后每满一年进行维修的是（ ）。",[444,446,448,450],{"key":20,"text":445,"correct":22},"推车式水基型灭火器",{"key":24,"text":447,"correct":22},"手提式水基型灭火器",{"key":27,"text":449,"correct":32},"推车式二氧化碳灭火器",{"key":30,"text":451,"correct":32},"推车式（储气瓶式）干粉灭火器",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":467,"analysis":34},965667,"《中华人民共和国刑法》规定。大型群众性活动重大安全事故罪是指举办大型群众性活动违反安全管理规定而发生重大伤亡事故或者造成其他严重后果的行为。下列举办大型群众性活动违反安全管理规定导致严重后果中，符合立案标准的是（ ）。",[456,458,460,462,464],{"key":20,"text":457,"correct":22},"2人死亡",{"key":24,"text":459,"correct":32},"2人重伤",{"key":27,"text":461,"correct":32},"导致公共财产或者他人财产直接经济损失45万元",{"key":30,"text":463,"correct":22},"导致公共财产或者他人财产直接经济损失55万元",{"key":465,"text":466,"correct":22},"E","导致公共财产或者他人财产直接经济损失65万元","ADE",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":110,"analysis":34},965668,"下列关于灭火器配置场所计算单元的划分说法正确的是（ ）。",[472,474,476,478,480],{"key":20,"text":473,"correct":22},"对于不相邻的灭火器配置场所，应分别作为一个计算单元进行灭火器的配置设计计算",{"key":24,"text":475,"correct":22},"灭火器配置场所的危险等级和火灾种类均相同的相邻场所，可将一个楼层或一个防火分区作为一个计算单元",{"key":27,"text":477,"correct":32},"同一计算单元可以跨越防火分区和楼层",{"key":30,"text":479,"correct":22},"灭火器配置场所的危险等级或火灾种类不相同的场所，应分别作为一个计算单元",{"key":465,"text":481,"correct":32},"—个计算单元只能含有一个灭火器配置场所",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":496,"analysis":34},965669,"扑救汽油火灾可选用（ ）灭火器。",[486,488,490,492,494],{"key":20,"text":487,"correct":32},"水",{"key":24,"text":489,"correct":22},"泡沫",{"key":27,"text":491,"correct":22},"磷酸铵盐干粉",{"key":30,"text":493,"correct":22},"二氧化碳",{"key":465,"text":495,"correct":22},"碳酸氢钠干粉","BCDE",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":509,"analysis":34},965670,"不是通过化学作用抑制链式反应实现灭火的灭火剂是（ ）。",[501,502,503,505,507],{"key":20,"text":487,"correct":22},{"key":24,"text":493,"correct":22},{"key":27,"text":504,"correct":32},"七氰丙烷",{"key":30,"text":506,"correct":32},"干粉",{"key":465,"text":508,"correct":22},"水雾","ABE",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":85,"analysis":34},965671,"灭火器日常检查中，发现灭火器达到维修条件或维修期限时。建筑使用管理单位应及时按照规定程序送修。下列（ ）的灭火器应及时送修。",[514,516,518,520],{"key":20,"text":515,"correct":32},"未曾使用过但出厂期刚满2年",{"key":24,"text":517,"correct":22},"再次维修以后刚满2年",{"key":27,"text":519,"correct":22},"筒体明显锈蚀",{"key":30,"text":521,"correct":22},"灭火剂泄露",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":85,"analysis":34},965672,"灭火器的维修期限，出厂期满五年首次维修以后每满二年的是（ ）。",[526,528,529,531],{"key":20,"text":527,"correct":32},"水基型灭火器",{"key":24,"text":449,"correct":22},{"key":27,"text":530,"correct":22},"手提式二氧化碳灭火器",{"key":30,"text":451,"correct":22},{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":47,"analysis":34},965673,"常见的灭火剂有（ ）等。",[536,537,539,540],{"key":20,"text":506,"correct":22},{"key":24,"text":538,"correct":32},"一氧化碳",{"key":27,"text":489,"correct":22},{"key":30,"text":493,"correct":22},{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":33,"analysis":34},965674,"扑救C类火灾，应选用（ ）型灭火器。",[545,546,548,549],{"key":20,"text":506,"correct":22},{"key":24,"text":547,"correct":22},"洁净气体",{"key":27,"text":508,"correct":22},{"key":30,"text":489,"correct":32},{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":110,"analysis":34},965675,"室内消火栓的配置应符合（ ）等。",[554,556,558,560],{"key":20,"text":555,"correct":22},"应采用DN65室内消火栓，并可与消防软管卷盘或轻便水龙设置在同一箱体内",{"key":24,"text":557,"correct":22},"应配备公称直径65有内衬里的消防水带，长度不宜超过25m",{"key":27,"text":559,"correct":32},"应配备公称直径65无内衬里的消防水带。长度不宜超过40m",{"key":30,"text":561,"correct":22},"宜配置当量喷嘴直径16mm或19mm的消防水枪",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":60,"analysis":34},965676,"在同一灭火器配置场所，宜选用（ ）。",[566,568,570,572],{"key":20,"text":567,"correct":22},"相同类型的灭火器",{"key":24,"text":569,"correct":22},"操作方法相同灭火器",{"key":27,"text":571,"correct":32},"不同类型的灭火器",{"key":30,"text":573,"correct":32},"操作方法不同灭火器",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":586,"analysis":34},965677,"干粉灭火器使用温度范围（ ）。",[578,580,582,584],{"key":20,"text":579,"correct":32},"二氧化碳驱动-5℃～＋55℃",{"key":24,"text":581,"correct":22},"氮气驱动-20℃～＋55℃",{"key":27,"text":583,"correct":22},"二氧化碳驱动-10℃～＋55℃",{"key":30,"text":585,"correct":32},"氮气驱动-10℃～＋55℃","BC",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":47,"analysis":34},965678,"（ ）属于B类火灾。",[591,593,595,597],{"key":20,"text":592,"correct":22},"汽油",{"key":24,"text":594,"correct":32},"木材",{"key":27,"text":596,"correct":22},"乙醇",{"key":30,"text":598,"correct":22},"石蜡",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":611,"analysis":34},965679,"消防应急广播系统线路常见故障一般有（ ）。",[603,605,607,609],{"key":20,"text":604,"correct":32},"总线故障",{"key":24,"text":606,"correct":22},"支线故障",{"key":27,"text":608,"correct":32},"枝线故障",{"key":30,"text":610,"correct":22},"干线故障","BD",[613,617,620,623,626,629],{"id":614,"name":615,"category":7,"favorite":616},1,"领导干部任职前廉政法规知识测试题",92,{"id":618,"name":619,"category":7,"favorite":614},595,"建筑结构与设备",{"id":621,"name":622,"category":7,"favorite":614},715,"招标采购专业知识与法律法规",{"id":624,"name":625,"category":7,"favorite":614},848,"市政方向-通用基础",{"id":627,"name":628,"category":7,"favorite":8},534,"BIM工程师",{"id":630,"name":628,"category":7,"favorite":8},535]