[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-28":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":592},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,28,50,2716,[13,35,48,60,73,84,96,108,116,129,139,151,162,171,180,191,199,207,215,224,240,254,269,281,293,305,317,332,345,357,369,381,394,406,418,428,438,448,460,472,484,496,507,518,528,538,550,561,571,582],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},965580,2,"多选题","电气火灾监控设备的设备外观保养要求包括（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","检查控制器是否安装牢固，对松动部位进行紧固",true,{"key":24,"text":25,"correct":22},"B","检查控制器的外观是否存在明显的机械损伤",{"key":27,"text":28,"correct":29},"C","检查部件的运行指示灯是否显示正常",false,{"key":31,"text":32,"correct":22},"D","操作控制器声光自检按键（钮），检查控器的音响和显示器件是否完好","ABD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},965581,"可燃气体报警控制器的运行环境保养要求包括（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":22},"清除控制器周边的可燃物、杂物",{"key":24,"text":42,"correct":29},"清除线型可燃气体探测器发射器和接收器之间的遮挡物",{"key":27,"text":44,"correct":22},"检查安装部位是否有漏水、渗水现象",{"key":31,"text":46,"correct":29},"检查控制器的显示是否正常","AC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":33,"analysis":34},965582,"消防设备电源状态监控器的设备外观保养要求包括（ ）。",[52,54,56,58],{"key":20,"text":53,"correct":22},"检查监控器是否安装牢固，对松动部位进行紧固",{"key":24,"text":55,"correct":22},"检查监控器的外观是否存在明显的机械损伤",{"key":27,"text":57,"correct":29},"检查传感器的运行指示灯是否显示正常",{"key":31,"text":59,"correct":22},"操作监控器声光自检按键（钮），检查控器的音响和显示器件是否完好",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":34},965583,"关于消防设备电源状态监控器的保养说法正确的有（ ）。",[64,66,68,70],{"key":20,"text":65,"correct":22},"表面清洁时，用吸尘器清洁控制器的操作面板，控制开关，机箱表面；用微湿的软布擦拭控制器机箱",{"key":24,"text":67,"correct":29},"设备报警功能测试要求：使探测器发出报警信号，检查探测器的报警确认灯点亮情况及控制器的显示情况",{"key":27,"text":69,"correct":22},"检查监控器的打印纸是否缺失，如缺失应予以更换",{"key":31,"text":71,"correct":22},"进行监控器的主备电源切换检查，对于不能满足备电持续工作时间的蓄电池予以更换","ACD",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":47,"analysis":34},965584,"消防设备电源状态监控器的运行环境保养要求包括（ ）。",[77,79,81,82],{"key":20,"text":78,"correct":22},"清除监控器周边的可燃物、杂物",{"key":24,"text":80,"correct":29},"清除探测器与互感器或其他设备之间的遮挡物",{"key":27,"text":44,"correct":22},{"key":31,"text":83,"correct":29},"检查监控器的显示是否正常",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":33,"analysis":34},965585,"消防设备电源状态监控器内部检查及吹扫要求包括（ ）。",[88,90,92,94],{"key":20,"text":89,"correct":22},"检查监控器接线口的封堵是否完好",{"key":24,"text":91,"correct":22},"检查各接线的绝缘护套是否有明显的龟裂、破损",{"key":27,"text":93,"correct":29},"检查控器的音响和显示器件是否完好",{"key":31,"text":95,"correct":22},"检查电路板和组件是否有松动",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":33,"analysis":34},965586,"防火门门磁开关、电动闭门器保养项目包括：运行环境、设备外观、表面清洁、反馈功能测试、内部检查及吹扫（ ）。",[100,102,104,106],{"key":20,"text":101,"correct":22},"设备外观",{"key":24,"text":103,"correct":22},"运行环境",{"key":27,"text":105,"correct":29},"内部检查及吹扫",{"key":31,"text":107,"correct":22},"反馈功能测试",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":47,"analysis":34},965587,"防火门监控器的运行环境保养要求包括（ ）。",[112,113,114,115],{"key":20,"text":78,"correct":22},{"key":24,"text":80,"correct":29},{"key":27,"text":44,"correct":22},{"key":31,"text":83,"correct":29},{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":128,"analysis":34},965588,"防火门门磁开关、电动闭门器运行环境保养要求（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":29},"清除监控器周围的可燃物、杂物",{"key":24,"text":123,"correct":22},"清除防火门与门框间的遮挡物",{"key":27,"text":125,"correct":22},"检查部件周围足否有漏水、渗水现象",{"key":31,"text":127,"correct":29},"检查部件的显示是否正常","BC",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":72,"analysis":34},965589,"防火门监控器日常保养项目包括（ ）等。",[133,134,136,137],{"key":20,"text":101,"correct":22},{"key":24,"text":135,"correct":29},"接地测试",{"key":27,"text":105,"correct":22},{"key":31,"text":138,"correct":22},"启动、反馈功能测试",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":72,"analysis":34},965590,"柴油发电机燃油供给系统的检查维护内容说法正确的有（ ）。",[143,145,147,149],{"key":20,"text":144,"correct":22},"检查油管及接头处有无漏油现象",{"key":24,"text":146,"correct":29},"检查加入的汽油的标号是否符合要求",{"key":27,"text":148,"correct":22},"检查油量是否充足",{"key":31,"text":150,"correct":22},"检查燃油箱盖上的通气孔是否畅通",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":33,"analysis":34},965591,"柴油发电机充放电装置检查维护内容包括（ ）。",[155,157,159,160],{"key":20,"text":156,"correct":22},"检查外观、按钮及标识应完好并清晰",{"key":24,"text":158,"correct":22},"检查散热口应无异物和遮挡",{"key":27,"text":144,"correct":29},{"key":31,"text":161,"correct":22},"检查内部的接线及配套附件应完好，无断路、脱落",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":72,"analysis":34},965592,"可燃气体探测系统日常保养项目包括（ ）等。",[166,167,168,169],{"key":20,"text":101,"correct":22},{"key":24,"text":135,"correct":29},{"key":27,"text":105,"correct":22},{"key":31,"text":170,"correct":22},"报警功能测试",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":33,"analysis":34},965593,"可燃气体报警控制器的设备外观保养要求包括（ ）。",[175,176,177,178],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":22},{"key":27,"text":28,"correct":29},{"key":31,"text":179,"correct":22},"操作控制器声光自检按通（钮），检查控器的音响和显示器件是否完好",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":128,"analysis":34},965594,"可燃气体探测器运行环境保养要求（ ）。",[184,186,188,190],{"key":20,"text":185,"correct":29},"消除控制器周边的可燃物、杂物",{"key":24,"text":187,"correct":22},"消除线型可燃气体探测器发射器和接收器之间的遮挡物",{"key":27,"text":189,"correct":22},"检查部件周围是否有漏水、渗水现象",{"key":31,"text":46,"correct":29},{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":33,"analysis":34},965595,"可燃气体探测器保养项目包括（ ）。",[195,196,197,198],{"key":20,"text":101,"correct":22},{"key":24,"text":103,"correct":22},{"key":27,"text":105,"correct":29},{"key":31,"text":170,"correct":22},{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":72,"analysis":34},965596,"消防设备电源状态监控器日常保养项目包括（ ）等。",[203,204,205,206],{"key":20,"text":101,"correct":22},{"key":24,"text":135,"correct":29},{"key":27,"text":105,"correct":22},{"key":31,"text":170,"correct":22},{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":33,"analysis":34},965597,"防火门监控器的设备外观保养要求包括（ ）。",[211,212,213,214],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":22},{"key":27,"text":28,"correct":29},{"key":31,"text":59,"correct":22},{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":33,"analysis":34},965598,"防火门监控器内部检查及吹扫要求包括（ ）。",[219,220,222,223],{"key":20,"text":89,"correct":22},{"key":24,"text":221,"correct":22},"检查各接线的绝缘护套是否有显的龟裂、破损",{"key":27,"text":93,"correct":29},{"key":31,"text":95,"correct":22},{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":239,"analysis":34},965599,"火灾显示盘故障原因（ ）。",[228,230,232,234,236],{"key":20,"text":229,"correct":22},"火灾显示盘本身坏",{"key":24,"text":231,"correct":22},"接线松动或接线断",{"key":27,"text":233,"correct":22},"无485通信电压",{"key":31,"text":235,"correct":22},"无24V电源电压",{"key":237,"text":238,"correct":29},"E","无232通信电压","ABCD",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":253,"analysis":34},965600,"CRT常见故障主要是：不能显示现场设备的报警及动作、故障、反馈、联动等异常信息。故障原因有（ ）。",[244,246,248,250,252],{"key":20,"text":245,"correct":22},"CRT软件出错；",{"key":24,"text":247,"correct":22},"主机与电脑232连接线松动或接线断；",{"key":27,"text":249,"correct":22},"电脑232端口坏；",{"key":31,"text":251,"correct":29},"电脑485端口坏；",{"key":237,"text":235,"correct":29},"ABC",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":268,"analysis":34},965601,"火灾报警系统二总线系统有（ ）几种方式。",[258,260,262,264,266],{"key":20,"text":259,"correct":22},"树枝型",{"key":24,"text":261,"correct":22},"环形",{"key":27,"text":263,"correct":29},"并联型",{"key":31,"text":265,"correct":29},"串联型",{"key":237,"text":267,"correct":22},"混合型","ABE",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":253,"analysis":34},965602,"消防广播系统MP3录放盘液晶屏不亮，原因可能是（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":22},"电源连线断路",{"key":24,"text":276,"correct":22},"设备损坏",{"key":27,"text":278,"correct":22},"录放盘处于待机状态",{"key":31,"text":280,"correct":29},"手持话筒PTT未释放",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":33,"analysis":34},965603,"消防电话在通话过程中出现单向通话现象，可能原因是（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":22},"主机手柄接触不良",{"key":24,"text":288,"correct":22},"分机手柄有质量问题",{"key":27,"text":290,"correct":29},"主、分机手柄接触不良",{"key":31,"text":292,"correct":22},"分机手柄接触不良",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":33,"analysis":34},965604,"消防电梯的设置要求有（ ）。",[297,299,301,303],{"key":20,"text":298,"correct":22},"消防电梯应设置前室",{"key":24,"text":300,"correct":22},"在首层的消防电梯井外璧上应设置供消防队员专用的操作按钮",{"key":27,"text":302,"correct":29},"消防电梯轿厢的内装修应采用难燃材料且其内部应设置专用消防对讲电话",{"key":31,"text":304,"correct":22},"消防电梯的井底应设置排水设施，前室门口宜设置挡水设施",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":72,"analysis":34},965605,"消防水泵房应设置起重设施，并应符合（ ）等。",[309,311,313,315],{"key":20,"text":310,"correct":22},"水泵重量为0.5-3t时，应设置手动起重设备",{"key":24,"text":312,"correct":29},"水泵重量小于0.5t时，宜设置手动起重设备",{"key":27,"text":314,"correct":22},"水泵重量大于3t时，应设置电动起重设备",{"key":31,"text":316,"correct":22},"水泵重量小于0.5t时，宜设置固定吊钩或移动吊架.",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":331,"analysis":34},965606,"总线故障维修难度较大，排查时应注意以下几点（ ）。",[321,323,325,327,329],{"key":20,"text":322,"correct":22},"检修时重点排查接线端子箱及分线盒等易出故障部位，一般可以提高工作效率；",{"key":24,"text":324,"correct":22},"检修人员应该熟悉工程现场环境，对于一些可能出现漏水的部位重点检查，例如空调口、给排水管附近等；",{"key":27,"text":326,"correct":22},"个别设备的故障也可能导致控制器报总线短路故障，检修确认设备故障后必须更换；",{"key":31,"text":328,"correct":29},"检查空气开关，确认空气开关是否因为过载而断开，如果空气开关断开可以打开；",{"key":237,"text":330,"correct":22},"总线绝缘性能很差时，个别控制器也会显示总线短路故障，绝缘性能不好也必须进行分段检修；","ABCE",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":344,"analysis":34},965607,"下列火灾自动报警系统误报的原因中，属于环境因素引起误报的原因有（ ）。",[336,338,340,342],{"key":20,"text":337,"correct":29},"探测器产品技术指标达不到要求",{"key":24,"text":339,"correct":29},"探测器选型不合理",{"key":27,"text":341,"correct":22},"空中电磁波干扰",{"key":31,"text":343,"correct":22},"气流可影响烟气的流动线路","CD",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":253,"analysis":34},965608,"消防联动控制器打印机不能动作的原因有（ ）。",[349,351,353,355],{"key":20,"text":350,"correct":22},"未设置成打印方式",{"key":24,"text":352,"correct":22},"打印机电缆接触不良",{"key":27,"text":354,"correct":22},"打印机损坏",{"key":31,"text":356,"correct":29},"打印机应更换色带",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":47,"analysis":34},965609,"消防水泵的出水管上应设（ ）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"止回阀",{"key":24,"text":364,"correct":29},"水力控制阀",{"key":27,"text":366,"correct":22},"明杆闸阀",{"key":31,"text":368,"correct":29},"普通蝶阀",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":253,"analysis":34},965610,"消防水源是向（ ）等提供消防用水的水源。",[373,375,377,379],{"key":20,"text":374,"correct":22},"灭火设施",{"key":24,"text":376,"correct":22},"车载或手抬等消防水泵",{"key":27,"text":378,"correct":22},"固定消防水泵",{"key":31,"text":380,"correct":29},"消防员饮水",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":393,"analysis":34},965611,"泡沫产生装置无法发泡或发泡不正常如何解决（ ）。",[385,387,389,391],{"key":20,"text":386,"correct":29},"更换已损坏的胶囊",{"key":24,"text":388,"correct":22},"定期检査吸气口及清理杂物",{"key":27,"text":390,"correct":22},"定期检查喷射口及清理杂物",{"key":31,"text":392,"correct":22},"更换密封玻璃，并重新进行密封性能试验，试验合格后方可安装","BCD",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":253,"analysis":34},965612,"泡沬比例混合装置无法形成或不能按比例形成泡沫混合液的原因有（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"泡沬液因储存环境不符合要求，失效变质",{"key":24,"text":401,"correct":22},"装置相关阀门、管道连接件密封失效，发生泄漏，而导致装置无法正常工作",{"key":27,"text":403,"correct":22},"消防水因含有较多杂质，运行中将水轮机损坏",{"key":31,"text":405,"correct":29},"装置中的安全阀故障、损坏，导致装置无法正常工作",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":253,"analysis":34},965613,"泡沬产生装置无法发泡或发泡不正常的原因包括（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"低倍数泡沬产生器密封玻璃密封不严或损坏，导致储罐内可燃液体蒸气外泄",{"key":24,"text":413,"correct":22},"泡沫产生装置吸气口被杂物堵塞，导致发泡不正常",{"key":27,"text":415,"correct":22},"外浮顶储罐泡沫导流累喷射□被杂物堵塞，导致泡沬无法正常喷射",{"key":31,"text":417,"correct":29},"装置相关阀门、管道连接件密封失效，发生泄漏.而导致装置无法正常工作",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":33,"analysis":34},965614,"泡沫比例混合装置无法形成或不能按比例形成泡沬混合液该如何维修（ ）。",[422,423,425,426],{"key":20,"text":386,"correct":22},{"key":24,"text":424,"correct":22},"检査平衡阀，更换损坏部件，必要时更换整个平衡阀",{"key":27,"text":388,"correct":29},{"key":31,"text":427,"correct":22},"检査损坏的水轮机，更换损坏的部件，必要时更换整个水轮机",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":253,"analysis":34},965615,"泡沬产生装置无法发泡或发泡不正常如何维修（ ）。",[432,433,434,436],{"key":20,"text":392,"correct":22},{"key":24,"text":388,"correct":22},{"key":27,"text":435,"correct":22},"定期检査喷射口及清理杂物",{"key":31,"text":437,"correct":29},"更换已变质的泡沬液",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":128,"analysis":34},965616,"泡沬喷雾灭火装置不能正常工作该如何解决（ ）。",[442,444,446,447],{"key":20,"text":443,"correct":29},"定期检査瓶组的压力，发现压力低于最低压力值时，应及时更换瓶组",{"key":24,"text":445,"correct":22},"拆下水雾喷头并清洗喷头内杂物",{"key":27,"text":435,"correct":22},{"key":31,"text":392,"correct":29},{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":459,"analysis":34},965617,"泡沫喷雾灭火装置不能正常工作的原因包括（ ）。",[452,454,456,457],{"key":20,"text":453,"correct":22},"启动瓶组、动力瓶组出现泄漏，导致装置无法正常工作",{"key":24,"text":455,"correct":22},"系统管理冲洗不到位，导致末端水雾喷头堵塞",{"key":27,"text":411,"correct":29},{"key":31,"text":458,"correct":29},"外浮顶储罐泡沫导流累喷射口被杂物堵塞，导致泡沬无法正常喷射","AB",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":253,"analysis":34},965618,"如何排除雨淋自动喷水灭火系统自动滴水阀长期渗漏的故障（ ）。",[464,466,468,470],{"key":20,"text":465,"correct":22},"消除阀瓣与阀瓣座之间的杂物",{"key":24,"text":467,"correct":22},"更换橡胶密封件",{"key":27,"text":469,"correct":22},"开启放水控制阀，排除系统侧管道内的余水",{"key":31,"text":471,"correct":29},"检査管道过滤器，清除滤网上的杂质或者更换过滤器",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":253,"analysis":34},965619,"雨淋自动喷水灭火系统出现使用一段时间后阀瓣自动开启的原因是（ ）。",[476,478,480,482],{"key":20,"text":477,"correct":22},"火灾自动报警系统误报，联动开启",{"key":24,"text":479,"correct":22},"节流孔板堵塞",{"key":27,"text":481,"correct":22},"电磁阀被误开或漏水",{"key":31,"text":483,"correct":29},"未将系统侧管网内的余水排尽",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":33,"analysis":34},965620,"如何排除预作用自动喷水灭火系统出现压力表读数不在正常范围的故障（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":22},"完全开启报警阀前的供水控制阀",{"key":24,"text":491,"correct":22},"拆卸压力表及其管路，疏通压力表管路",{"key":27,"text":493,"correct":29},"关闭末端试水装置阀门",{"key":31,"text":495,"correct":22},"完全开启压力表管路控制阀",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":253,"analysis":34},965621,"维保时发现某单位雨淋自动喷水灭火系统雨淋报警阀不能进入伺应状态，需如何排除此问题（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"修复或者更换复位装置",{"key":24,"text":503,"correct":22},"开启隔膜室控制阀、复位球阀",{"key":27,"text":505,"correct":22},"将供水控制阀关闭，拆下过滤器的滤网，用清水冲洗干净后，重新安装到位",{"key":31,"text":469,"correct":29},{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":459,"analysis":34},965622,"预作用自动喷水灭火系统出现自动滴水阀长期渗漏的原因是（ ）。",[511,513,515,516],{"key":20,"text":512,"correct":22},"阀瓣与阀瓣座之间有杂物",{"key":24,"text":514,"correct":22},"橡胶件变形损坏",{"key":27,"text":483,"correct":29},{"key":31,"text":517,"correct":29},"末端试水装置阀门未关或关闭不严",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":459,"analysis":34},965623,"预作用自动喷水灭火系统出现自动滴水阀长期渗漏的处理方法正确的是（ ）。",[522,523,525,526],{"key":20,"text":465,"correct":22},{"key":24,"text":524,"correct":22},"更换橡胶件",{"key":27,"text":493,"correct":29},{"key":31,"text":527,"correct":29},"用水冲洗或清理杂质",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":253,"analysis":34},965624,"预作用自动喷水灭火系统出现预作用装置一直报警原因是（ ）。",[532,534,535,537],{"key":20,"text":533,"correct":22},"水中杂质导致阀瓣关闭不严",{"key":24,"text":517,"correct":22},{"key":27,"text":536,"correct":22},"阀瓣损坏或胶垫脱落",{"key":31,"text":517,"correct":29},{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":72,"analysis":34},965625,"预作用自动喷水灭火系统出现压力表读数不在正常范围的原因包括（ ）。",[542,544,546,548],{"key":20,"text":543,"correct":22},"压力表管路控制阀未打开或者开启不完全",{"key":24,"text":545,"correct":29},"管道内有大量空气",{"key":27,"text":547,"correct":22},"预作用报警装置的报警阀体漏水",{"key":31,"text":549,"correct":22},"预作用报报警装置前的供水控制阀未打开",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":253,"analysis":34},965626,"预作用自动喷水灭火系统出现压力表读数不在正常范围该如何解决（ ）。",[554,555,557,559],{"key":20,"text":489,"correct":22},{"key":24,"text":556,"correct":22},"拆卸圧力表及其管理、疏通压力表管路",{"key":27,"text":558,"correct":22},"按照湿式报警阀组渗漏的原因进行检査、分析，査找预作用报警装置的报警阀体的漏水部位，修复或者更换组件",{"key":31,"text":560,"correct":29},"完全关闭压力表管路控制阀",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":459,"analysis":34},965627,"雨淋自动喷水灭火系统出现雨淋阀阀瓣渗漏的原因可能是（ ）。",[565,567,569,570],{"key":20,"text":566,"correct":22},"阀瓣与阀瓣密封面处有异物",{"key":24,"text":568,"correct":22},"阀座或阀瓣损坏或阀座松动",{"key":27,"text":477,"correct":29},{"key":31,"text":479,"correct":29},{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":33,"analysis":34},965628,"如何排除预作用自动喷水灭火系统测试不报警的问题（ ）。",[575,577,579,580],{"key":20,"text":576,"correct":22},"拆下过滤器，用清水将滤网冲洗干净后，重新安装到位",{"key":24,"text":578,"correct":22},"检查水力警铃的配件，配齐组件",{"key":27,"text":467,"correct":29},{"key":31,"text":581,"correct":22},"对于有杂物卡阻、堵塞的部件，进行冲洗后重新装配到位",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":344,"analysis":34},965629,"预作用自动喷水灭火系统传动管喷头堵塞的故障如何排除（ ）。",[586,587,588,590],{"key":20,"text":489,"correct":29},{"key":24,"text":491,"correct":29},{"key":27,"text":589,"correct":22},"对水质进行检测，清理不干净、影响系统正常使用的消防用水",{"key":31,"text":591,"correct":22},"检査管道过滤器，消除滤网上的杂质或者更换过滤器",[593,597,600,603,606,609],{"id":594,"name":595,"category":7,"favorite":596},1,"领导干部任职前廉政法规知识测试题",92,{"id":598,"name":599,"category":7,"favorite":594},595,"建筑结构与设备",{"id":601,"name":602,"category":7,"favorite":594},715,"招标采购专业知识与法律法规",{"id":604,"name":605,"category":7,"favorite":594},848,"市政方向-通用基础",{"id":607,"name":608,"category":7,"favorite":8},534,"BIM工程师",{"id":610,"name":608,"category":7,"favorite":8},535]