[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-26":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":626},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,26,50,2716,[13,35,48,58,70,81,93,106,118,130,141,154,166,178,190,202,214,225,237,250,262,274,285,297,309,321,333,346,358,370,382,395,407,419,431,443,455,465,473,485,497,509,522,538,551,566,578,590,602,614],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},965479,2,"多选题","下面关于固定消防泡灭火系统的说法正确的是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","消防水泡灭火系统是以水作为灭火介质，以消防泡作为喷射设备的灭火系统",true,{"key":24,"text":25,"correct":22},"B","消防泡沫泡灭火系统是以泡沫混合液作为灭火介质，以消防泡作为喷射设备的灭火系统",{"key":27,"text":28,"correct":29},"C","消防干粉泡灭火系统是以干粉作为灭火介质，以消防泡作为喷射设备的灭火系统",false,{"key":31,"text":32,"correct":22},"D","消防干粉泡灭火系统是以干粉作为灭火介质，以消防干粉泡作为喷射设备的灭火系统","ABD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},965480,"消防水泡灭火系统可用于哪些场所？（ ）",[39,41,43,45],{"key":20,"text":40,"correct":22},"石化企业",{"key":24,"text":42,"correct":22},"飞机维修库",{"key":27,"text":44,"correct":22},"输油码头",{"key":31,"text":46,"correct":29},"飞机库","ABC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":57,"analysis":34},965481,"消防泡沫泡灭火系统适用于哪些场所？（ ）",[52,53,54,55],{"key":20,"text":40,"correct":22},{"key":24,"text":42,"correct":29},{"key":27,"text":46,"correct":22},{"key":31,"text":56,"correct":22},"仓库","ACD",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":47,"analysis":34},965482,"消防水泡灭火系统工作原理为：（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"火灾发生时，开启消防泵组及管路阀门",{"key":24,"text":65,"correct":22},"消防水经消防泵加压获得的静压能，在消防泡喷喷处转换为动能",{"key":27,"text":67,"correct":22},"高速水流由喷嘴射向火源",{"key":31,"text":69,"correct":29},"能够隔绝空气使其窒息",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":47,"analysis":34},965483,"消防泡沫泡灭火系统工作原理：（ ）。",[74,75,77,79],{"key":20,"text":63,"correct":22},{"key":24,"text":76,"correct":22},"消防压力水流经泡沫混合装置时按照一定的比例与泡沫原液混合，形成泡沫混合液，并在消防泡喷嘴处以高速射流喷出",{"key":27,"text":78,"correct":22},"泡沫混合液射流在消防泡喷嘴处及空中卷吸入空气，与空气混合、发泡形成空气泡沫液",{"key":31,"text":80,"correct":29},"空气泡沫液被投射到火源根部灭火",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":33,"analysis":34},965484,"电动启动水喷雾灭火系统是通过（ ）火灾探测器探测火灾的。",[85,87,89,91],{"key":20,"text":86,"correct":22},"感温",{"key":24,"text":88,"correct":22},"感烟",{"key":27,"text":90,"correct":29},"线型",{"key":31,"text":92,"correct":22},"缆式",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":105,"analysis":34},965485,"传动管启动水喷雾灭火系统一般适用于（ ）。",[97,99,101,103],{"key":20,"text":98,"correct":22},"防爆场所",{"key":24,"text":100,"correct":22},"不适合安装普通火灾探测系统的场所",{"key":27,"text":102,"correct":29},"所有场所",{"key":31,"text":104,"correct":29},"北方寒冷场所","AB",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":57,"analysis":34},965486,"电动启动的电动控制部分由（ ）等设备组成。",[110,112,114,116],{"key":20,"text":111,"correct":22},"火灾报警控制器",{"key":24,"text":113,"correct":29},"灭火控制盘",{"key":27,"text":115,"correct":22},"输出输入模块",{"key":31,"text":117,"correct":22},"火灾探测器",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":33,"analysis":34},965487,"电动启动情况下，当只有一种探测器发出火警信号时（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"水喷雾灭火控制盘即发出火灾声、光警报信号，通知有异常情况发生",{"key":24,"text":125,"correct":22},"不启动灭火装置释放灭火剂",{"key":27,"text":127,"correct":29},"发出联动指令，关闭风机、防火阀等联动设备",{"key":31,"text":129,"correct":22},"如确需启动水喷雾灭火系统灭火时，在水喷雾灭火控制盘面板按下“紧急启动”按钮，即可启动灭火装置",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":47,"analysis":34},965488,"电动启动情况下，当两个或两类探测器同时发出火警信号时（ ）。",[134,136,138,139],{"key":20,"text":135,"correct":22},"水喷雾灭火控制器发出火灾声、光警报信号，通知有火灾发生",{"key":24,"text":137,"correct":22},"有关人员应撤离现场",{"key":27,"text":127,"correct":22},{"key":31,"text":140,"correct":29},"同时发出灭火指令，启动水泵释放灭火剂（水），实施灭火",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":153,"analysis":34},965489,"电动启动情况下，如处于延时阶段不需要启动灭火系统，可操作（ ），即可终止控制灭火指令的发出。",[145,147,149,151],{"key":20,"text":146,"correct":22},"保护区外的手动控制盒上的“紧急停止”按钮",{"key":24,"text":148,"correct":29},"保护区内的手动控制盒上的“紧急停止”按钮",{"key":27,"text":150,"correct":22},"灭火控制盘控制操作面板上的“紧急中断”按钮",{"key":31,"text":152,"correct":29},"灭火控制盘控制操作面板上的“紧急停止”按钮","AC",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":33,"analysis":34},965490,"按照传动管启动原理，火灾发生时，（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"传动管上的闭式洒水喷水开启",{"key":24,"text":161,"correct":22},"雨淋报警阀开启",{"key":27,"text":163,"correct":29},"经过一段延时后，即发出灭火指令",{"key":31,"text":165,"correct":22},"水雾喷水开始喷水灭火",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":47,"analysis":34},965491,"关于水喷雾灭火系统手动控制方式的说法正确的是（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"当火灾探测器发出火警信号时，火灾报警控制器即发出火灾声、光报警信号，但不会启动水喷雾灭火系统",{"key":24,"text":173,"correct":22},"如需启动灭火系统，需经消防值班人员确认后，可按下保护区外或控制器操作面板上的“紧急启动”按钮",{"key":27,"text":175,"correct":22},"或将火灾报警控制器和水喷雾灭火控制盘的“手动”状态转换为“自动”状态",{"key":31,"text":177,"correct":29},"经过一段延时后，即可启动水喷雾灭火系统，释放灭火剂，实施灭火",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":105,"analysis":34},965492,"（ ）时，用应急机械启动控制方式启动水喷雾灭火系统。",[182,184,186,188],{"key":20,"text":183,"correct":22},"水喷雾灭火控制器失效",{"key":24,"text":185,"correct":22},"急需紧急启动水喷雾灭火系统",{"key":27,"text":187,"correct":29},"消防值班人员确认有火灾时",{"key":31,"text":189,"correct":29},"经过一段延时后",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":57,"analysis":34},965493,"细水雾灭火系统由（ ）等组成。",[194,196,198,200],{"key":20,"text":195,"correct":22},"加压供水设备（泵组或瓶组）",{"key":24,"text":197,"correct":29},"雨淋控制阀组",{"key":27,"text":199,"correct":22},"细水雾喷头必",{"key":31,"text":201,"correct":22},"系统管网",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":105,"analysis":34},965494,"柜式灭火装置的工作原理是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"当启动机构接收到控制盘的启动信号后动作，通过启动机构开启干粉储存容器的容器阀",{"key":24,"text":209,"correct":22},"容器内的驱动气体驱动干粉灭火剂从容器阀喷出，进而喷向保护空间",{"key":27,"text":211,"correct":29},"罐中干粉灭火剂疏松形成便于流动的粉气混合物，同时使干粉储罐内的压力很快升高",{"key":31,"text":213,"correct":29},"干粉灭火剂被气体输送，经过总阀门、选择阀、输粉管输送到喷放组件，把干粉灭火剂喷向保护对象，实施灭火。",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":33,"analysis":34},965495,"以下哪些是储压型干粉灭火系统的组成部件（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"干粉储罐及其配件",{"key":24,"text":221,"correct":22},"安全泄放装置",{"key":27,"text":223,"correct":29},"干粉控制器",{"key":31,"text":111,"correct":22},{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":47,"analysis":34},965496,"储压型干粉灭火系统的工作原理：（ ）。",[229,231,233,235],{"key":20,"text":230,"correct":22},"当启动机构接收到控制盘的启动信号后动作",{"key":24,"text":232,"correct":22},"通过启动机构开启干粉储存容器的容器阀",{"key":27,"text":234,"correct":22},"容器内的驱动气体驱动干粉灭火剂从容器阀喷出",{"key":31,"text":236,"correct":29},"进而通过选择阀喷向保护空间或者着火对象",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":249,"analysis":34},965497,"关于柴油发电机组的描述正确的是（ ）。",[241,243,245,247],{"key":20,"text":242,"correct":29},"当柴油发电机组兼做其他重要设备的备用电源时，要考虑同时使用情况",{"key":24,"text":244,"correct":29},"柴油发电机组的容量应满足两种消防设备同时运行时的容量要求",{"key":27,"text":246,"correct":22},"当柴油发电机组兼做其他重要设备的备用电源时，还应考虑备用电源的容量",{"key":31,"text":248,"correct":22},"应急发电机组有柴油发电机组和燃气轮机发电机组两种","CD",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":33,"analysis":34},965498,"水幕系统处于准工作状态时，由（ ）等稳压设施维持管道内充水的压力。",[254,256,258,260],{"key":20,"text":255,"correct":22},"消防水箱",{"key":24,"text":257,"correct":22},"稳压泵",{"key":27,"text":259,"correct":29},"消防转输水泵",{"key":31,"text":261,"correct":22},"气压给水设备",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":47,"analysis":34},965499,"关于水幕系统的工作原理正确的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"发生火灾时，由火灾自动报警系统联动开启雨淋报警阀组和供水泵，向系统管网和喷头供水。",{"key":24,"text":269,"correct":22},"防火分隔水幕系统利用密集喷洒形成的水墙或多层水帘，可封堵防火分区处的孔洞，阻挡火灾和烟气的蔓延，因此适用于局部防火分隔处",{"key":27,"text":271,"correct":22},"防护冷却水幕系统利用喷水在物体表面形成的水膜，控制防火分区处分隔物的温度",{"key":31,"text":273,"correct":29},"防护冷却水幕系统使分隔物的完整性和稳定性免遭火灾破坏",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":47,"analysis":34},965500,"水幕系统同时具备三种开启报警阀组的控制方式：（ ）。",[278,280,281,283],{"key":20,"text":279,"correct":22},"自动控制方式",{"key":24,"text":279,"correct":22},{"key":27,"text":282,"correct":22},"手动应急操作方式",{"key":31,"text":284,"correct":29},"机械应急操作方式",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":153,"analysis":34},965501,"当自动控制的水幕系统用于防火卷帘的保护时（防护冷却水幕系统），应由（ ）组成“与”逻辑作为水幕阀组启动的联动触发信号，并应由消防联动控制器联动控制水幕系统相关控制阀组的启动，雨淋报警阀开启，压力开关动作，连锁启动水幕消防泵。",[289,291,293,295],{"key":20,"text":290,"correct":22},"防火卷帘下落到楼板面的动作信号与本报警区域内任一火灾探测器的报警信号",{"key":24,"text":292,"correct":29},"防火卷帘下落到1.8m的动作信号与本报警区域内任一火灾探测器的报警信",{"key":27,"text":294,"correct":22},"防火卷帘下落到楼板面的动作信号与本报警区域内任一手动火灾报警按钮的报警信号",{"key":31,"text":296,"correct":29},"防火卷帘下落到1.8m的动作信号与本报警区域内不同火灾探测器的报警信号",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":105,"analysis":34},965502,"关于水幕系统的手动控制方式说法正确的是（ ）。",[301,303,305,307],{"key":20,"text":302,"correct":22},"水幕系统相关控制阀组和消防泵控制箱（柜）的启动、停止按钮是用专用线路直接连接至设置在消防控制室内的消防联动控制器的手动控制盘",{"key":24,"text":304,"correct":22},"消防控制盘能够直接手动控制消防泵的启动、停止及水幕系统相关控制阀组的开启",{"key":27,"text":306,"correct":29},"水幕系统开启后，需有权限的管理人员确认才能停止",{"key":31,"text":308,"correct":29},"应由该报警区域内任一火灾探测器的火灾报警信号作为水幕阀组启动的联动触发信号",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":47,"analysis":34},965503,"（ ）等的供电，应在其配电线路的最末一级配电箱处设置自动切换装置。",[313,315,317,319],{"key":20,"text":314,"correct":22},"消防控制室",{"key":24,"text":316,"correct":22},"消防水泵房",{"key":27,"text":318,"correct":22},"防烟和排烟风机房",{"key":31,"text":320,"correct":29},"电梯",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":249,"analysis":34},965504,"对消防设备末端配电装置的手动一自动转换功能说法正确的是（ ）。",[325,327,329,331],{"key":20,"text":326,"correct":29},"当控制装置设复位按钮时，如果电源回路出现过载或短路故障，断路器断开后，不可立即操作断路器闭合",{"key":24,"text":328,"correct":29},"只有排除故障，并按复位按钮后，方能闭合断开的断路器",{"key":27,"text":330,"correct":22},"当控制装置设有手动-自动转换按键时，操作按键处于手动状态时，在控制装置面板上，可手动控制主电源断路器、备用电源断路器的分、合",{"key":31,"text":332,"correct":22},"操作按键处于自动状态时，控制装置根据监测电源工作状态，可控制主电源和备用电源之间进行自动转换、恢复",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":345,"analysis":34},965505,"双电源自动切换装置适用于交流（ ）Hz、（ ）V的两路电源（主电源和备用电源或发电电源），当一路电源发生故障时实现电源之间的自动切换，以保证供电的可靠性和安全性。",[337,339,341,343],{"key":20,"text":338,"correct":22},"50",{"key":24,"text":340,"correct":29},"100",{"key":27,"text":342,"correct":29},"200",{"key":31,"text":344,"correct":22},"400","AD",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":47,"analysis":34},965506,"当消防设备电源发生（ ）等故障时，消防设备电源状态监控器能及时发出故障声、光信号，显示并记录故障的部位、类型和时间。",[350,352,354,356],{"key":20,"text":351,"correct":22},"断电",{"key":24,"text":353,"correct":22},"过负荷",{"key":27,"text":355,"correct":22},"过流",{"key":31,"text":357,"correct":29},"缺相",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":47,"analysis":34},965507,"消防设备电源状态监控器通常由（ ）等部分组成。",[362,364,366,368],{"key":20,"text":363,"correct":22},"工作状态指示灯",{"key":24,"text":365,"correct":22},"液晶显示屏",{"key":27,"text":367,"correct":22},"操作键盘",{"key":31,"text":369,"correct":29},"备用电源",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":47,"analysis":34},965508,"以下关于消防设备电源状态监控器各部分功能的说法正确的有（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"工作状态指示灯用于指示监控器的工作状态",{"key":24,"text":377,"correct":22},"液晶显示屏用于显示监控器的运行和报警信息",{"key":27,"text":379,"correct":22},"操作键盘用于对监控器进行操作",{"key":31,"text":381,"correct":29},"打印机用于消防控制制日常办公",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":394,"analysis":34},965509,"操作键盘用于对监控器进行操作。按照各按键的功能来划分，可以分为（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":29},"状态显示类按键",{"key":24,"text":389,"correct":22},"特殊功能类按键",{"key":27,"text":391,"correct":22},"设置功能类按键",{"key":31,"text":393,"correct":22},"字符键","BCD",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":33,"analysis":34},965510,"以下关于消防设备电源状态监控器的描述正确的有（ ）。",[399,401,403,405],{"key":20,"text":400,"correct":22},"打印机釆用的是正面换纸方式的热敏打印机，方便用户更换打印纸。",{"key":24,"text":402,"correct":22},"当主电源断电时，能自动转换到备用电源；当主电源恢复时，能自动转换到主电源。",{"key":27,"text":404,"correct":29},"备用电源满电状态下，能提供监控器在正常监视状态下至少工作12h",{"key":31,"text":406,"correct":22},"回路板用于巡检、釆集、分析、处理与本回路连接的消防设备电源监控传感器的工作状态和消防设备电源状态。",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":33,"analysis":34},965511,"消防设备电源状态监控器的基本功能包括（ ）等。",[411,413,415,417],{"key":20,"text":412,"correct":22},"主电源和备用电源转换功能",{"key":24,"text":414,"correct":22},"故障报警功能",{"key":27,"text":416,"correct":29},"信息报警功能",{"key":31,"text":418,"correct":22},"历史事件记录功能",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":47,"analysis":34},965512,"以下哪些是消防设备电源状态监控器的基本功能（ ）。",[423,425,427,429],{"key":20,"text":424,"correct":22},"消音功能",{"key":24,"text":426,"correct":22},"自检功能",{"key":27,"text":428,"correct":22},"复位功能",{"key":31,"text":430,"correct":29},"信息记录功能",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":105,"analysis":34},965513,"电压、电流、电压\u002F电流传感器是消防设备电源监控系统的基本组件，用于（ ）。",[435,437,439,441],{"key":20,"text":436,"correct":22},"实时釆集消防设备电源状态",{"key":24,"text":438,"correct":22},"将电源状态上传给消防设备电源状态监控器",{"key":27,"text":440,"correct":29},"为电源监控系统提供稳定的电源",{"key":31,"text":442,"correct":29},"监视消防设备的工作状态",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":345,"analysis":34},965514,"下面哪些是常见的传感器（ ）。",[447,449,451,453],{"key":20,"text":448,"correct":22},"交流单相电压传感器",{"key":24,"text":450,"correct":29},"交流双相电压\u002F电流传感器",{"key":27,"text":452,"correct":29},"交流四相电压传感器",{"key":31,"text":454,"correct":22},"交流三相电压\u002F电流传感器",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":105,"analysis":34},965515,"（ ）能够釆集四路被监测设备电源的电压值。",[459,460,462,464],{"key":20,"text":448,"correct":22},{"key":24,"text":461,"correct":22},"交流单相电压\u002F电流传感器",{"key":27,"text":463,"correct":29},"交流三相电压传感器",{"key":31,"text":454,"correct":29},{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":105,"analysis":34},965516,"（ ）可用于监测供电电源为AC220V的消防设备。",[469,470,471,472],{"key":20,"text":448,"correct":22},{"key":24,"text":461,"correct":22},{"key":27,"text":463,"correct":29},{"key":31,"text":454,"correct":29},{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":47,"analysis":34},965517,"交流单相电压传感器和交流单相电压\u002F电流传感器可用于监测供电电源为AC220V的消防设备。如（ ）等。",[477,479,481,483],{"key":20,"text":478,"correct":22},"报警设备",{"key":24,"text":480,"correct":22},"电源配电箱",{"key":27,"text":482,"correct":22},"应急照明回路",{"key":31,"text":484,"correct":29},"消防水泵",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":33,"analysis":34},965518,"交流三相电压\u002F电流传感器可用于监测供电电源为AC380V的消防设备，如（ ）等。",[489,491,493,495],{"key":20,"text":490,"correct":22},"风机",{"key":24,"text":492,"correct":22},"泵类设备",{"key":27,"text":494,"correct":29},"交流单相电源配电箱",{"key":31,"text":496,"correct":22},"交流三相电源配电箱",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":394,"analysis":34},965519,"下列表述，属于消防电梯设置要求的是：（ ）。",[501,503,505,507],{"key":20,"text":502,"correct":29},"电梯载重量不应小于600kg",{"key":24,"text":504,"correct":22},"行驶速度从首层到顶层的运行时间不应超过60s",{"key":27,"text":506,"correct":22},"电梯轿厢内应设专用电话",{"key":31,"text":508,"correct":22},"在首层消防电梯入口处应设供消防队员专用的操作按钮",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":521,"analysis":34},965520,"下列建筑物、储罐（区）和堆场的消防用电应按二级负荷供电（ ）。 A.室外消防用水量大于25L\u002FS的厂房（仓库）",[513,515,517,519],{"key":20,"text":514,"correct":29},"室外消防用水量大于35L\u002FS的可燃材料堆场、可燃气体储罐（区）和甲、乙类液体储罐（区），粮食仓库及粮食筒仓",{"key":24,"text":516,"correct":22},"座位数超过2000个的体育馆",{"key":27,"text":518,"correct":29},"任一层建筑面积大于3000㎡的商店和展览建筑",{"key":31,"text":520,"correct":22},"省（市）级及以上的广播电视、电信和财贸金融建筑，室外消防用水量大于15L\u002FS的其他公共建筑。","BD",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":537,"analysis":34},965521,"下列场所的消防用电应按一级负荷供电（ ）。",[526,528,530,532,534],{"key":20,"text":527,"correct":22},"建筑高度大于50m的乙、丙类生产厂房和丙类物品库房",{"key":24,"text":529,"correct":22},"一类高层民用建筑",{"key":27,"text":531,"correct":29},"重要公共建筑",{"key":31,"text":533,"correct":22},"一级大型石油化工厂",{"key":535,"text":536,"correct":22},"E","大型钢铁联合企业，大型物资仓库等。","ABDE",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":394,"analysis":34},965522,"自备发电机燃油储备要求在燃油来源及运输不便时，可在建筑物主体外设（ ）h贮油设施。",[542,544,546,547,549],{"key":20,"text":543,"correct":29},"35",{"key":24,"text":545,"correct":22},"45",{"key":27,"text":338,"correct":22},{"key":31,"text":548,"correct":22},"60",{"key":535,"text":550,"correct":29},"65",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":565,"analysis":34},965523,"消防用电设备与适宜备用电源种类一览表中应急发电机组不适宜系统使用的是（ ）。",[555,557,559,561,563],{"key":20,"text":556,"correct":22},"消防联动控制系统",{"key":24,"text":558,"correct":29},"干粉灭火系统",{"key":27,"text":560,"correct":29},"消防电梯",{"key":31,"text":562,"correct":22},"火灾自动报警系统",{"key":535,"text":564,"correct":22},"消防应急照明和疏散指示系统","ADE",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":105,"analysis":34},965524,"消防水泵主要由泵壳、泵轴、（ ）等组成。",[570,572,574,576],{"key":20,"text":571,"correct":22},"叶轮",{"key":24,"text":573,"correct":22},"密封",{"key":27,"text":575,"correct":29},"泵体",{"key":31,"text":577,"correct":29},"控制柜",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":394,"analysis":34},965525,"消防水泵不能现场手动启动的原因是（ ）。",[582,584,586,588],{"key":20,"text":583,"correct":29},"控制柜电流表损坏",{"key":24,"text":585,"correct":22},"电动机定子绕组匝间短路",{"key":27,"text":587,"correct":22},"填料密封过紧",{"key":31,"text":589,"correct":22},"控制柜二次回路开路",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":57,"analysis":34},965526,"消防电源是指在火灾时能保证消防用电设备继续正常运行的独立电源，其设置的基本要求有：耐火性、（ ）。",[594,596,598,600],{"key":20,"text":595,"correct":22},"安全性",{"key":24,"text":597,"correct":29},"独特性",{"key":27,"text":599,"correct":22},"经济性",{"key":31,"text":601,"correct":22},"科学性",{"id":603,"libraryId":5,"type":15,"typeLabel":16,"stem":604,"options":605,"answer":47,"analysis":34},965527,"对于电气火灾监控系统报警测试方法说法错误的是：（ ）。",[606,608,610,612],{"key":20,"text":607,"correct":22},"釆用剩余电流发生器模拟产生剩余电流，使探测器达到报警条件，进入报警状态",{"key":24,"text":609,"correct":22},"釆用可调温式热风机或者其他可控温度的加温设备给探测器的感温元件加温，使探测器达到报警条件，进入报警状态。",{"key":27,"text":611,"correct":22},"釆用故障电弧模拟发生装置产生故障电弧，使探测器达到报警条件，进入报警状态。",{"key":31,"text":613,"correct":29},"剩余电流发生器通常用于系统生产或验收模拟时测试电气火灾监控探测器灵敏度及报警功能，电流固定，不可调节。",{"id":615,"libraryId":5,"type":15,"typeLabel":16,"stem":616,"options":617,"answer":249,"analysis":34},965528,"电气火灾监控系统的报警功能描述正确的有（ ）。",[618,620,622,624],{"key":20,"text":619,"correct":29},"当被保护线路剩余电流达到报警设定值时，剩余电流式电气火灾监控探测器应40s内发出报警信号。",{"key":24,"text":621,"correct":29},"当被监视部位温度达到报警设定值时，测温式电气火灾监控探测器应在30s内发出报警信号。",{"key":27,"text":623,"correct":22},"当被探测线路在1s内发生14个及以上半周期的故障电弧时，故障电弧探测器应在30s内发出报警信号。",{"key":31,"text":625,"correct":22},"电气火灾监控设备应能接收来自探测器的报警信号，并在10s内发出声、光报警信号，指示报警部位，显示报警时间。",[627,631,634,637,640,643],{"id":628,"name":629,"category":7,"favorite":630},1,"领导干部任职前廉政法规知识测试题",92,{"id":632,"name":633,"category":7,"favorite":628},595,"建筑结构与设备",{"id":635,"name":636,"category":7,"favorite":628},715,"招标采购专业知识与法律法规",{"id":638,"name":639,"category":7,"favorite":628},848,"市政方向-通用基础",{"id":641,"name":642,"category":7,"favorite":8},534,"BIM工程师",{"id":644,"name":642,"category":7,"favorite":8},535]