[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-25":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":666},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,25,50,2716,[13,35,48,61,73,86,99,111,123,136,148,160,172,184,196,208,220,236,248,260,272,284,296,306,319,331,343,355,367,379,391,406,421,436,450,464,479,493,507,520,535,550,564,579,593,607,619,631,642,654],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},965427,2,"多选题","下面哪些场所适合使用局部应用方式开式细水雾灭火系统？（ ）",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","计算机房",false,{"key":24,"text":25,"correct":26},"B","油浸变压器",true,{"key":28,"text":29,"correct":22},"C","燃气轮机",{"key":31,"text":32,"correct":26},"D","燃气轮机的轴承","BD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},965428,"开式细水雾灭火系统的工作原理（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":22},"当系统的火灾探测器发现火灾后，自动或手动打开雨淋控制阀组",{"key":24,"text":42,"correct":26},"同时发出火灾报警信号给报警控制器",{"key":28,"text":44,"correct":26},"并启动细水雾消防水泵",{"key":31,"text":46,"correct":26},"通过供水管网到达细水雾喷头，细水雾喷头喷水灭火","BCD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},965429,"对预作用式细水雾灭火系统准工作状态的描述正确的有（ ）。",[52,54,56,58],{"key":20,"text":53,"correct":26},"由稳压设施维持预作用阀组入口前管道内充水的压力",{"key":24,"text":55,"correct":26},"预作用报警阀后的管道内平时无水",{"key":28,"text":57,"correct":26},"预作用报警阀后的管道内平时可充以有压气体",{"key":31,"text":59,"correct":22},"预作用报警阀前后管道内压力一致","ABC",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":60,"analysis":34},965430,"预作用式细水雾灭火系统的工作原理说法正确的是：（ ）",[65,67,69,71],{"key":20,"text":66,"correct":26},"发生火灾时，与喷头一起安装在同一保护区的火灾探测器首先发出火灾报警信号",{"key":24,"text":68,"correct":26},"报警控制器确认后，在声光报警的同时即自动启动预作用阀组的驱动装置",{"key":28,"text":70,"correct":26},"将预作用控制阀打开，开始配水管道排气充水的预作用过程",{"key":31,"text":72,"correct":22},"使系统在开式喷头动作前转换成湿式系统，并能在开式喷头开启后立即喷水",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":85,"analysis":34},965431,"预作用式细水雾灭火系统准工作状态时，由（ ）等稳压设施维持预作用阀组入口前管道内充水的压力。",[77,79,81,83],{"key":20,"text":78,"correct":26},"消防水箱",{"key":24,"text":80,"correct":26},"稳压泵",{"key":28,"text":82,"correct":22},"转输水箱",{"key":31,"text":84,"correct":26},"气压给水设备","ABD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},965432,"对湿式细水雾灭火系统的工作原理的说法正确的有（ ）。",[90,92,94,96],{"key":20,"text":91,"correct":26},"发生火灾时，在火灾温度的作用下，闭式喷头的热敏元件动作，喷头开启并开始喷水",{"key":24,"text":93,"correct":22},"此时，管网中的水由静止变为流动，流量开关动作送出电信号，在报警控制器上显示所有区域喷水的信息",{"key":28,"text":95,"correct":26},"由于持续喷水泄压造成管网水压下降，压力开关动作并输出启动供水泵的信号",{"key":31,"text":97,"correct":26},"供水泵投入运行后，完成系统的启动过程，实施灭火","ACD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":85,"analysis":34},965433,"自动控制方式下，当两个或两类探测器同时发出火警信号时，（ ）。",[103,105,107,109],{"key":20,"text":104,"correct":26},"细水雾灭火控制盘发出火灾声、光警报信号，通知有火灾发生",{"key":24,"text":106,"correct":26},"有关人员应撤离现场，并发出联动指令，关闭风机、防火阀等联动设备",{"key":28,"text":108,"correct":22},"同时发出灭火指令，启动细水雾水泵",{"key":31,"text":110,"correct":26},"火灾报警控制器联动控制细水雾灭火控制盘打开区域控制电磁阀，释放灭火剂（水），实施灭火",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":85,"analysis":34},965434,"关于开式及预作用细水雾灭火系统手动控制方式的说法正确的是（ ）。",[115,117,119,121],{"key":20,"text":116,"correct":26},"将火灾报警控制器或灭火控制盘上的控制方式设为“手动”状态时，火灾报警控制器或细水雾灭火控制盘处于手动控制状态",{"key":24,"text":118,"correct":26},"当火灾探测器发出火警信号时，火灾报警控制器即发出火灾声、光报警信号，而不联动启动细水雾灭火系统",{"key":28,"text":120,"correct":22},"如需启动灭火系统，可立即按下保护区外的手动控制盒或控制器操作面板上的“紧急启动”按钮",{"key":31,"text":122,"correct":26},"将火灾报警控制器和细水雾灭火控制盘的“手动”状态转换为“自动”状态可可启动灭火装置",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":135,"analysis":34},965435,"开式及预作用细水雾灭火系统处于手动控制状态下，当发生火灾时，火灾报警控制系统未能及时发现火灾，如何启动灭火装置灭火（ ）。",[127,129,131,133],{"key":20,"text":128,"correct":22},"先经消防值班人员确认",{"key":24,"text":130,"correct":26},"由消防操作人员水喷雾灭火控制盘操作面板上的“按下启动”按钮",{"key":28,"text":132,"correct":26},"由消防操作人员操作保护区外的手动控制盒上的“启动按下”按钮",{"key":31,"text":134,"correct":22},"操作保护区外的手动控制盒上的“紧急开启”按钮","BC",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":60,"analysis":34},965436,"对于细水雾开式或预作用式灭火系统的应急机械启动工作方式描述正确的是（ ）。",[140,142,144,146],{"key":20,"text":141,"correct":26},"手动关闭联动设备并切断电源",{"key":24,"text":143,"correct":26},"启动细水雾消防水泵，手动打开对应区域分区控制阀",{"key":28,"text":145,"correct":26},"细水雾控制阀开启后，若为开式灭火系统，细水雾灭火系统管网开始充水，实施灭火",{"key":31,"text":147,"correct":22},"若为湿式灭火系统，细水雾灭火系统管网开始充水，待闭式细水雾洒水喷头玻璃球爆破后即可实施灭火",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":135,"analysis":34},965437,"干粉灭火系统按照干粉灭火剂充压方式的不同，分为（ ）干粉灭火系统。",[152,154,156,158],{"key":20,"text":153,"correct":22},"常压型",{"key":24,"text":155,"correct":26},"储气瓶型",{"key":28,"text":157,"correct":26},"储压型",{"key":31,"text":159,"correct":22},"高压型",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":135,"analysis":34},965438,"储气瓶型干粉灭火系统由两部分组成：（ ）。",[164,166,168,170],{"key":20,"text":165,"correct":22},"干粉存储设备部分",{"key":24,"text":167,"correct":26},"干粉灭火设备部分",{"key":28,"text":169,"correct":26},"火灾自动报警及联动控制部分",{"key":31,"text":171,"correct":22},"消防控制柜",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":60,"analysis":34},965439,"储气瓶型干粉灭火系统的干粉灭火设备部分由（ ）等构成。",[176,178,180,182],{"key":20,"text":177,"correct":26},"干粉储罐及其配件",{"key":24,"text":179,"correct":26},"驱动气体瓶组",{"key":28,"text":181,"correct":26},"安全泄放装置",{"key":31,"text":183,"correct":22},"干粉喷洒器",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":195,"analysis":34},965440,"储气瓶型干粉灭火系统的火灾自动报警及联动控制部分由（ ）等组成。",[188,190,192,193],{"key":20,"text":189,"correct":26},"火灾探测器",{"key":24,"text":191,"correct":26},"火灾报警控制器",{"key":28,"text":181,"correct":22},{"key":31,"text":194,"correct":22},"干粉喷放器","AB",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":98,"analysis":34},965442,"关于储气瓶型干粉灭火系统的动作顺序正确的是（ ）。",[200,202,204,206],{"key":20,"text":201,"correct":26},"启动机构-储气瓶-减压器-干粉储",{"key":24,"text":203,"correct":22},"干粉储罐-选择阀-出口总阀门—输粉管",{"key":28,"text":205,"correct":26},"出口总阀门-选择阀-输粉管-干粉枪或干粉泡",{"key":31,"text":207,"correct":26},"出口总阀门-选择阀-输粉管-固定喷嘴",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":60,"analysis":34},965443,"柜式灭火装置主要由（ ）等组成。",[212,214,216,218],{"key":20,"text":213,"correct":26},"柜体",{"key":24,"text":215,"correct":26},"干粉储罐",{"key":28,"text":217,"correct":26},"输粉管道",{"key":31,"text":219,"correct":22},"干粉报警控制器",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":235,"analysis":34},965445,"下列关于预作用系统功能测试检测要求正确的是（ ）。",[224,226,228,230,232],{"key":20,"text":225,"correct":22},"报警阀组动作后，测试水水力警铃声强，不得低于60dB",{"key":24,"text":227,"correct":22},"开启末端试水装置，火灾报警控制器确认火灾lmin后，其出水压力不低于0.05MPa",{"key":28,"text":229,"correct":26},"模拟火灾探测报警，火灾报警控制器确认火灾后，自动启动预作用装置（雨淋报警阀）、排气阀入口电动阀以及消防水泵；水流指示器、压力开关动作",{"key":31,"text":231,"correct":26},"消防控制设备准确显示电磁阀、电动阀、水流指示器以及消防水泵动作信号，反馈信号准确",{"key":233,"text":234,"correct":22},"E","检查报警阀组外观标志，标识清晰、内容详实，符合产品生产技术标准要求，并注明系统名称和保护区域，压力表显示符合设定值","CD",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":85,"analysis":34},965446,"柴油机消防泵组手动启动式包括（ ）。",[240,242,244,246],{"key":20,"text":241,"correct":26},"控制柜上的手动启动",{"key":24,"text":243,"correct":26},"柴油机仪表箱上的手动启动",{"key":28,"text":245,"correct":22},"传动装置上的手动启动",{"key":31,"text":247,"correct":26},"柴油机上的手动启动",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":47,"analysis":34},965447,"下面哪些是柴油机消防泵控制柜的基本要求？（ ）。",[252,254,256,258],{"key":20,"text":253,"correct":22},"控制柜具有可见且能指示控制柜处于手动控制状态的开关",{"key":24,"text":255,"correct":26},"控制柜具有可接收远程启动信号和就地启动按钮启动消防泵的功能",{"key":28,"text":257,"correct":26},"压力记录，故障\u002F报警信息记录",{"key":31,"text":259,"correct":26},"运行、故障\u002F报警反馈输出信号",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":60,"analysis":34},965448,"关于消防水泵应急启动的说法正确的是：（ ）。",[264,266,268,270],{"key":20,"text":265,"correct":26},"在火灾等紧急情况下，当消防水泵控制柜的控制线路发生故障而供电正常时使用",{"key":24,"text":267,"correct":26},"操作设置在消防水泵控制柜上的强制机械应急手柄",{"key":28,"text":269,"correct":26},"直接使主回路交流接触器吸合",{"key":31,"text":271,"correct":22},"手动启动消防水泵",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":60,"analysis":34},965449,"关于机械应急启动装置的说法正确的是（ ）。",[276,278,280,282],{"key":20,"text":277,"correct":26},"机械应急启动装置必须通过消防水泵控制柜的接触器实现",{"key":24,"text":279,"correct":26},"低压机械应急启动装置是在接触器上加装机械装置",{"key":28,"text":281,"correct":26},"高压机械应急启动装置由弹簧蓄能组成",{"key":31,"text":283,"correct":22},"一般消防上常用的为高压机械应急启动装置",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":235,"analysis":34},965450,"高压机械应急启动装置由弹簧蓄能组成，所需的电源是（ ）或（ ）。",[288,290,292,294],{"key":20,"text":289,"correct":22},"380",{"key":24,"text":291,"correct":22},"1000",{"key":28,"text":293,"correct":26},"6000",{"key":31,"text":295,"correct":26},"10000",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":47,"analysis":34},965451,"下面关于机械应急启动装置的描述正确的是（ ）。",[300,302,303,305],{"key":20,"text":301,"correct":22},"高压机械应急启动装置所需的电源是6000V",{"key":24,"text":277,"correct":26},{"key":28,"text":304,"correct":26},"低压机械应急启动装置所需的电源是380V",{"key":31,"text":281,"correct":26},{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":318,"analysis":34},965452,"消防水泵机械应急启动装置主要由（ ）组成。",[310,312,314,316],{"key":20,"text":311,"correct":26},"接触器单元",{"key":24,"text":313,"correct":22},"机械装置",{"key":28,"text":315,"correct":26},"机械运动单元",{"key":31,"text":317,"correct":22},"弹簧蓄能","AC",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":47,"analysis":34},965453,"消防水泵机械应急启动装置的接触器单元内包括（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"电动装置",{"key":24,"text":326,"correct":26},"弹性部件",{"key":28,"text":328,"correct":26},"动触头",{"key":31,"text":330,"correct":26},"静触头",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":195,"analysis":34},965454,"接触器单元工作原理是（ ）。",[335,337,339,341],{"key":20,"text":336,"correct":26},"在电磁装置的供电电源未接通时，弹性部件的作用力使动触头脱离静触头，消防水泵电动机的供电主回路被断开",{"key":24,"text":338,"correct":26},"在电磁装置的供电电源接通时，电磁装置产生电磁力，克服弹性部件的作用力，使动触头接通静触头，消防水泵电动机的供电主回路被接通",{"key":28,"text":340,"correct":22},"人工向手柄施加作用力，该作用力通过拉索传递给运动部件，运动部件带动机械臂运动",{"key":31,"text":342,"correct":22},"手动闭锁后，接触器的动触头接通静触头",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":60,"analysis":34},965455,"拉锁型机械运动单元的工作原理：（ ）。",[347,349,351,353],{"key":20,"text":348,"correct":26},"人工向手柄施加作用力",{"key":24,"text":350,"correct":26},"该作用力通过拉索传递给运动部件，",{"key":28,"text":352,"correct":26},"运动部件带动机械臂运动，使接触器的每一相动触头都能平衡可靠地",{"key":31,"text":354,"correct":22},"同时接通动触头，可有效地防止缺相接通产生的有害电弧",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":47,"analysis":34},965456,"湿式报警阀组安装应符合下列（ ）规定。",[359,361,363,365],{"key":20,"text":360,"correct":22},"报警阀组的安装应在供水管网试压、冲洗合格前进行",{"key":24,"text":362,"correct":26},"安装时应先安装水源控制阀、报警阀，然后进行报警阀辅助管道的连接，水源控制阀、报警阀与配水干管的连接，应使水流方向一致。",{"key":28,"text":364,"correct":26},"报警阀组安装的位置应符合设计要求；当设计无要求时，报警阀组应安装在便于操作的明显位置，距室内地面高度宜为1.2m；两侧与墙的距离不应小于0.5m；正面与墙的距离不应小于1.2m；报警阀组凸出部位之间的距离不应小于0.5m。",{"key":31,"text":366,"correct":26},"安装报警阀组的室内地面应有排水设施。",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":85,"analysis":34},965457,"雨淋报警阀不能进入伺应状态的故障原因包括（ ）。",[371,373,375,377],{"key":20,"text":372,"correct":26},"复位装置存在问题。",{"key":24,"text":374,"correct":26},"未按照安装调试说明书将报警阀组调试到伺应状态（隔膜室控制阀、复位球阀未关闭）",{"key":28,"text":376,"correct":22},"电磁阀故障",{"key":31,"text":378,"correct":26},"消防用水水质存在问题，杂质堵塞了隔膜室管道上的过滤器。",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":60,"analysis":34},965458,"水流指示器的检查要求（ ）。",[383,385,387,389],{"key":20,"text":384,"correct":26},"水流指示器的外观应完好，无明显碰伤，无漏水现象；",{"key":24,"text":386,"correct":26},"水流指示器的所在的位置应便于操作；",{"key":28,"text":388,"correct":26},"水流指示器动作时，报警控制器应正确显示其监管（反馈）信息。",{"key":31,"text":390,"correct":22},"水流指示器动作时，启动喷淋泵。",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":405,"analysis":34},965459,"末端放水的外观应完好，组件（ ）应齐全。",[395,397,399,401,403],{"key":20,"text":396,"correct":26},"截止阀",{"key":24,"text":398,"correct":26},"压力表",{"key":28,"text":400,"correct":22},"排气阀",{"key":31,"text":402,"correct":26},"试水接头",{"key":233,"text":404,"correct":26},"排水水漏斗","ABDE",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":420,"analysis":34},965460,"对于火灾探测器控制的雨淋报警阀组，试验前关闭报警阀系统侧的控制阀，在同一防护区内模拟2类不同的火灾探测报警信号，查看火灾报警控制器火灾报警、确认以及联动指令发出情况，逐一检查（ ）等动作情况。",[410,412,414,416,418],{"key":20,"text":411,"correct":26},"报警阀",{"key":24,"text":413,"correct":26},"电磁阀",{"key":28,"text":415,"correct":26},"压力开关",{"key":31,"text":417,"correct":22},"信号阀",{"key":233,"text":419,"correct":26},"消防水泵","ABCE",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":435,"analysis":34},965461,"干式报警阀系统侧气压不足，引起系统侧有水溢出，不能维持准工作状态；正确的处理方法是（ ）。",[425,427,429,431,433],{"key":20,"text":426,"correct":26},"检查空压机工作是否正常，能否正常供压；检查压力表（气压）是否正常；",{"key":24,"text":428,"correct":22},"关闭主控制阀",{"key":28,"text":430,"correct":26},"检查复位阀是否复位；",{"key":31,"text":432,"correct":26},"打开干式报警阀前盖，清理内部脏物，并复位；",{"key":233,"text":434,"correct":26},"报警测试阀是否关闭严密；","ACDE",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":405,"analysis":34},965462,"下列关于干式报警阀维护保养程序说法中正确的是（ ）。",[440,442,444,446,448],{"key":20,"text":441,"correct":26},"每年至少进行一次报警阀正确运行验证试验（即火灾时报警阀的正常开启）",{"key":24,"text":443,"correct":26},"水流报警季度试验",{"key":28,"text":445,"correct":22},"每月自动排水阀检查",{"key":31,"text":447,"correct":26},"每周应对水压表进行检查，确保系统维持正常的水压。",{"key":233,"text":449,"correct":26},"每周应对气压表进行检查，确保系统维持正常的气压。",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":420,"analysis":34},965463,"关于湿式报警阀误报警处理说法中正确的是（ ）。",[454,456,458,460,462],{"key":20,"text":455,"correct":26},"发现误报警时，可检查整个管网是否漏水，检查延迟器溢出孔是否堵塞或排水不畅。打开泄放试验阀可排空系统内积水或检验供水管网是否堵塞。",{"key":24,"text":457,"correct":26},"检查湿式报警阀阀瓣组件与阀座之间是否密封不严，使大量的水进入延时器。",{"key":28,"text":459,"correct":26},"检查管网中的喷头是否因意外原因导致将释放机构启动。",{"key":31,"text":461,"correct":22},"关闭控制阀。",{"key":233,"text":463,"correct":26},"查出误报警原因后，应及时处理，以确保系统任何时候都处于良好的准工作状态。",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":478,"analysis":34},965464,"下列系统中，（ ）属于闭式自动喷水灭火系统。",[468,470,472,474,476],{"key":20,"text":469,"correct":26},"湿式自动喷水灭火系统",{"key":24,"text":471,"correct":26},"干式自动喷水灭火系统",{"key":28,"text":473,"correct":22},"雨淋系统",{"key":31,"text":475,"correct":22},"水幕系统",{"key":233,"text":477,"correct":26},"预作用自动喷水灭火系统","ABE",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":420,"analysis":34},965465,"末端试水装置的作用是（ ）。",[483,485,487,489,491],{"key":20,"text":484,"correct":26},"测试相关系统最不利点处喷头的工作压力",{"key":24,"text":486,"correct":26},"测试相关系统配水管道是否畅通",{"key":28,"text":488,"correct":26},"测试相关系统的工况是否正常",{"key":31,"text":490,"correct":22},"直接启动相关系统的消防水泵",{"key":233,"text":492,"correct":26},"测试相关系统的管道充水时间",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":318,"analysis":34},965466,"干式喷水灭火系统适用的环境温度为（ ）。",[497,499,501,503,505],{"key":20,"text":498,"correct":26},"低于4℃",{"key":24,"text":500,"correct":22},"高于4℃",{"key":28,"text":502,"correct":26},"高于70℃",{"key":31,"text":504,"correct":22},"低于70℃",{"key":233,"text":506,"correct":22},"不限",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":60,"analysis":34},965467,"自动喷水灭火系统中的闭式喷头具有（ ）作用。",[511,513,515,517,519],{"key":20,"text":512,"correct":26},"定温探测器",{"key":24,"text":514,"correct":26},"定温阀",{"key":28,"text":516,"correct":26},"布水器",{"key":31,"text":518,"correct":22},"警报器",{"key":233,"text":415,"correct":22},{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":534,"analysis":34},965468,"湿式报警阀组的作用是（ ）。",[524,526,528,530,532],{"key":20,"text":525,"correct":26},"接通或关断水流",{"key":24,"text":527,"correct":26},"发出声响警报",{"key":28,"text":529,"correct":26},"防止管网水倒流",{"key":31,"text":531,"correct":26},"启动消防水泵",{"key":233,"text":533,"correct":22},"喷水","ABCD",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":549,"analysis":34},965469,"自动喷水灭火系统的水压试验时，下列描述错误的是（ ）。",[539,541,543,545,547],{"key":20,"text":540,"correct":26},"水压强度试验的测试点设在系统管网的最高点",{"key":24,"text":542,"correct":22},"环境温度不应低于5℃，当低于5℃时，釆取防冻措施",{"key":28,"text":544,"correct":22},"管网注水时，将管网内的空气排净，缓慢升压",{"key":31,"text":546,"correct":26},"水压严密性试验在水压强度试验和管网冲洗前进行",{"key":233,"text":548,"correct":22},"达到试验压力后，稳压24h，管网无泄漏","AD",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":405,"analysis":34},965470,"干式报警阀组除按照报警阀组安装的共性要求进行安装、技术检测外，还需符合（ ）要求。",[554,556,558,560,562],{"key":20,"text":555,"correct":26},"安装完成后，向报警阀气室注入高度为50-100mm的清水",{"key":24,"text":557,"correct":26},"不可安装在冰冻的场所",{"key":28,"text":559,"correct":22},"安全排气阀安装在气源与报警阀组之间，靠近气源一侧",{"key":31,"text":561,"correct":26},"加速器安装在靠近报警阀的位置，设有防止水流进入加速器的措施",{"key":233,"text":563,"correct":26},"报警阀充水一侧和充气一侧、空气压缩机的气泵和储气罐以及加速排气装置等部位分别安装压力表",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":578,"analysis":34},965471,"干式系统与预作用系统的不同之处在于（ ）。",[568,570,572,574,576],{"key":20,"text":569,"correct":26},"靠喷头破裂启动系统",{"key":24,"text":571,"correct":22},"平时配水管道一定充有有压气体",{"key":28,"text":573,"correct":26},"利用管道内的有压气体启动系统",{"key":31,"text":575,"correct":22},"闭式喷头动作后立即喷水",{"key":233,"text":577,"correct":26},"闭式喷头动作后不能立即喷水","ACE",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":478,"analysis":34},965472,"预作用喷水灭火系统（ ）。",[583,585,587,589,591],{"key":20,"text":584,"correct":26},"预作用报警阀到管网末端充以有压气体",{"key":24,"text":586,"correct":26},"釆用闭式喷头",{"key":28,"text":588,"correct":22},"釆用开式喷头",{"key":31,"text":590,"correct":22},"喷头动作后才排气充水",{"key":233,"text":592,"correct":26},"火灾自动报警装置报警后立即排气充水",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":405,"analysis":34},965473,"报警阀组可分为（ ）。",[597,599,601,603,605],{"key":20,"text":598,"correct":26},"湿式报警阀组",{"key":24,"text":600,"correct":26},"干式报警阀组",{"key":28,"text":602,"correct":22},"水幕报警阀组",{"key":31,"text":604,"correct":26},"雨淋报警阀组",{"key":233,"text":606,"correct":26},"预作用报警装置",{"id":608,"libraryId":5,"type":15,"typeLabel":16,"stem":609,"options":610,"answer":60,"analysis":34},965474,"消防干粉泡灭火系统工作原理：（ ）",[611,613,615,617],{"key":20,"text":612,"correct":26},"火灾发生时，开启氮气瓶组",{"key":24,"text":614,"correct":26},"其内的高压氮气经过减压阀减压后进入干粉储罐，其中一部分氮气被送入储罐项部与干粉灭火剂混合，另一部分氮气被送人储罐底部对干粉灭火剂进行松散。",{"key":28,"text":616,"correct":26},"随着系统压力的建立，混合有高压气体的干粉灭火剂和聚在干粉泡阀门处",{"key":31,"text":618,"correct":22},"当管路压力达到峰值时，开启干粉泡阀门，固、气两相态的干粉灭火剂通过消防干粉泡高速射向火源，切割火焰、破坏燃烧链",{"id":620,"libraryId":5,"type":15,"typeLabel":16,"stem":621,"options":622,"answer":60,"analysis":34},965475,"固定消防泡灭火系统按喷射介质可分为（ ）。",[623,625,627,629],{"key":20,"text":624,"correct":26},"消防水泡灭火系统",{"key":24,"text":626,"correct":26},"消防泡沫泡灭火系统",{"key":28,"text":628,"correct":26},"消防干粉泡灭火系统",{"key":31,"text":630,"correct":22},"消防气体泡灭火系统",{"id":632,"libraryId":5,"type":15,"typeLabel":16,"stem":633,"options":634,"answer":135,"analysis":34},965476,"固定消防泡灭火系统按控制和操作方式可分为（ ）。",[635,637,639,641],{"key":20,"text":636,"correct":22},"自动消防泡灭火系统",{"key":24,"text":638,"correct":26},"远控消防泡灭火系统",{"key":28,"text":640,"correct":26},"手动消防泡灭火系统",{"key":31,"text":624,"correct":22},{"id":643,"libraryId":5,"type":15,"typeLabel":16,"stem":644,"options":645,"answer":135,"analysis":34},965477,"远控消防泡的驱动方式主要有（ ）等。",[646,648,650,652],{"key":20,"text":647,"correct":22},"温控",{"key":24,"text":649,"correct":26},"电控",{"key":28,"text":651,"correct":26},"液控",{"key":31,"text":653,"correct":22},"气控",{"id":655,"libraryId":5,"type":15,"typeLabel":16,"stem":656,"options":657,"answer":135,"analysis":34},965478,"消防泡沫泡灭火系统适用于（ ）火灾的扑救。",[658,660,662,664],{"key":20,"text":659,"correct":22},"一般固体可燃物",{"key":24,"text":661,"correct":26},"甲、乙，丙类液体",{"key":28,"text":663,"correct":26},"固体可燃物",{"key":31,"text":665,"correct":22},"可燃气体",[667,671,674,677,680,683],{"id":668,"name":669,"category":7,"favorite":670},1,"领导干部任职前廉政法规知识测试题",92,{"id":672,"name":673,"category":7,"favorite":668},595,"建筑结构与设备",{"id":675,"name":676,"category":7,"favorite":668},715,"招标采购专业知识与法律法规",{"id":678,"name":679,"category":7,"favorite":668},848,"市政方向-通用基础",{"id":681,"name":682,"category":7,"favorite":8},534,"BIM工程师",{"id":684,"name":682,"category":7,"favorite":8},535]