[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-22":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":640},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,22,50,2716,[13,35,47,60,72,84,96,109,121,134,146,157,169,181,193,204,214,226,238,250,262,274,286,298,310,322,334,350,365,380,394,408,418,427,436,450,465,474,488,502,517,530,543,557,569,581,593,605,616,628],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},965271,2,"多选题","关于控制中心报警系统的说法正确的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","具有两个及两个以上消防控制室时应设置控制中心报警系统并确定主消防控制室和分消防控制室",true,{"key":24,"text":25,"correct":22},"B","起集中监控功能的火灾报警控制器设置在主消防控制室内，具有火灾自动报警和消防联动控制功能",{"key":27,"text":28,"correct":22},"C","集中型火灾报警控制器设置在分消防控制室内，也具有火灾自动报警和消防联动控制功能",{"key":30,"text":31,"correct":32},"D","集中型火灾报警控制器不能独立进行火灾自动探测报警和消防联动控制",false,"ABC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":33,"analysis":34},965272,"对于主、分消防控制室之间火灾报警控制器的通信功能说法正确的是（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":22},"主消防控制室内的消防设备应能显示各分消防控制室内消防设备的状态信息",{"key":24,"text":42,"correct":22},"各分消防控制室内的控制和显示装置之间可以互相传输、显示状态信息",{"key":27,"text":44,"correct":22},"主消防控制室内的消防设备可对分消防控制室内的消防设备及其控制的消防系统和设备进行控制",{"key":30,"text":46,"correct":32},"各分消防控制室内的控制和显示装置可以互相控制",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":59,"analysis":34},965273,"火灾报警控制器之间通常釆用RS485、CAN等通信方式进行联网，联网方式有以下几种：（ ）",[51,53,55,57],{"key":20,"text":52,"correct":32},"三角型联网拓扑",{"key":24,"text":54,"correct":22},"总线型联网拓扑",{"key":27,"text":56,"correct":22},"环型联网拓扑",{"key":30,"text":58,"correct":22},"星型联网拓扑","BCD",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":33,"analysis":34},965274,"消防设备电源监控系统由（ ）等部分或全部设备组成。",[64,66,68,70],{"key":20,"text":65,"correct":22},"消防设备电源状态监控器",{"key":24,"text":67,"correct":22},"电压传感器",{"key":27,"text":69,"correct":22},"电流传感器",{"key":30,"text":71,"correct":32},"电量传感器",{"id":73,"libraryId":5,"type":15,"typeLabel":16,"stem":74,"options":75,"answer":33,"analysis":34},965275,"下列符合消防设备电源监控系统的工作原理的是（ ）。",[76,78,80,82],{"key":20,"text":77,"correct":22},"系统通过电压传感器、电流传感器、电压\u002F电流传感器实时监视消防设备的电源状态",{"key":24,"text":79,"correct":22},"当监视到消防设备电源发生断电、过压、欠压、过流、缺相、错相等故障时，实时将故障信息上传至消防设备电源状态监控器",{"key":27,"text":81,"correct":22},"由监控器发出故障警报，显示故障类型和位置",{"key":30,"text":83,"correct":32},"同时将故障报警信息上传给消防控制室图形显示装置，提示消防控制室对故障进行及时处理",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":95,"analysis":34},965276,"当消防设备电源监控系统监视到消防设备电源发生断电、过压、欠压、过流、缺相、错相等故障时，以下说法正确的是（ ）。",[88,90,91,93],{"key":20,"text":89,"correct":22},"实时将故障信息上传至消防设备电源状态监控器",{"key":24,"text":81,"correct":22},{"key":27,"text":92,"correct":32},"同时将故障报警信息上传给消防远程监控系统",{"key":30,"text":94,"correct":22},"提示消防设施操作员对故障进行及时处理","ABD",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":108,"analysis":34},965277,"关于消防设备电源状态监控器的描述正确的有（ ）。",[100,102,104,106],{"key":20,"text":101,"correct":22},"消防设备电源状态监控器是消防设备电源监控系统的核心设备",{"key":24,"text":103,"correct":32},"仅为监控器自身提供稳定的工作电源",{"key":27,"text":105,"correct":22},"通过传感器实时监控消防设备电源的状态",{"key":30,"text":107,"correct":22},"当消防设备电源发生断电、过压、欠压、过流、缺相、错相等故障时，及时发出故障声、光信号，显示并记录故障的部位、类型和时间","ACD",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":95,"analysis":34},965278,"消防设备电源状态监控器工作状态指示灯颜色对应正确的是（ ）。",[113,115,117,119],{"key":20,"text":114,"correct":22},"消音-绿色",{"key":24,"text":116,"correct":22},"故障-黄色",{"key":27,"text":118,"correct":32},"屏蔽-绿色",{"key":30,"text":120,"correct":22},"通讯故障-黄色",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":133,"analysis":34},965279,"消防设备电源状态监控器工作状态指示灯亮绿色时，可能是什么状态？（ ）。",[125,127,129,131],{"key":20,"text":126,"correct":22},"主电工作",{"key":24,"text":128,"correct":22},"备电工作",{"key":27,"text":130,"correct":32},"主电故障",{"key":30,"text":132,"correct":32},"备电故障","AB",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":108,"analysis":34},965280,"哪些状态时消防设备电源状态监控器工作状态指示灯亮黄色？（ ）。",[138,140,142,144],{"key":20,"text":139,"correct":22},"屏蔽",{"key":24,"text":141,"correct":32},"消音",{"key":27,"text":143,"correct":22},"欠压",{"key":30,"text":145,"correct":22},"缺相",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":59,"analysis":34},965282,"当电气火灾监控设备有监控报警信号、故障报警信号、屏蔽信号输入时，应向消防控制室图形显示装置发送输入信号的类别、名称、部位、位置、时间、工作状态（正常工作状态、火灾报警状态、屏蔽状态以及故障状态（ ）等信息。",[150,152,154,156],{"key":20,"text":151,"correct":32},"火灾报警",{"key":24,"text":153,"correct":22},"监控报警",{"key":27,"text":155,"correct":22},"故障报警",{"key":30,"text":139,"correct":22},{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":108,"analysis":34},965283,"当电气火灾监控设备有监控报警信号、故障报警信号、屏蔽信号输入时，应向消防控制室图形显示装置发送输入信号的（ ）等信息。",[161,163,165,167],{"key":20,"text":162,"correct":22},"类别",{"key":24,"text":164,"correct":32},"过程",{"key":27,"text":166,"correct":22},"位置",{"key":30,"text":168,"correct":22},"工作状态",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":133,"analysis":34},965284,"（ ）属于火灾预警系统。",[173,175,177,179],{"key":20,"text":174,"correct":22},"电气火灾监控系统",{"key":24,"text":176,"correct":22},"可燃气体探测报警系统",{"key":27,"text":178,"correct":32},"消防泡灭火系统",{"key":30,"text":180,"correct":32},"自动喷水灭火系统",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":33,"analysis":34},965285,"可燃气体报警控制器与消防控制室图形显示装置应釆用专用线路连接，一般釆用（ ）等通信接口。",[185,187,189,191],{"key":20,"text":186,"correct":22},"RS232",{"key":24,"text":188,"correct":22},"CAN",{"key":27,"text":190,"correct":22},"以太网",{"key":30,"text":192,"correct":32},"并口",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":33,"analysis":34},965286,"电气火灾监控设备与消防控制室图形显示装置应釆用专用线路连接，一般釆用（ ）等通信接口。通信接口应具有防脱落措施。",[197,199,201,202],{"key":20,"text":198,"correct":22},"USB",{"key":24,"text":200,"correct":22},"LAN\u002FWAN",{"key":27,"text":190,"correct":22},{"key":30,"text":203,"correct":32},"RS483",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":213,"analysis":34},965287,"火灾报警控制器之间通常釆用（ ）等通信方式进行联网。",[208,209,211,212],{"key":20,"text":203,"correct":32},{"key":24,"text":210,"correct":22},"R5485",{"key":27,"text":188,"correct":22},{"key":30,"text":190,"correct":32},"BC",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":33,"analysis":34},965288,"关于火灾报警控制器之间几种联网方式的说法正确的有（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"总线型联网拓扑布线要求简单、扩充容易、增删不影响其他工作",{"key":24,"text":221,"correct":22},"环型联网拓扑简化了路径选择的控制、控制软件简单",{"key":27,"text":223,"correct":22},"星型联网拓扑易于维护、安全性高、系统可靠性高",{"key":30,"text":225,"correct":32},"星型联网拓扑维护难、分支节点故障查找难",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":237,"analysis":34},965289,"关于火灾报警控制器之间几种联网方式的优缺点描述正确的有（ ）。",[230,232,234,235],{"key":20,"text":231,"correct":32},"环型联网拓扑布线要求简单、扩充容易、增删不影响其他工作",{"key":24,"text":233,"correct":32},"总线型联网拓扑简化了路径选择的控制、控制软件简单",{"key":27,"text":223,"correct":22},{"key":30,"text":236,"correct":22},"总线型联网拓扑维护难、分支节点故障查找难","CD",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":249,"analysis":34},965290,"关于火灾报警控制器之间几种联网方式的优缺点说法正确的有（ ）。",[242,244,246,247],{"key":20,"text":243,"correct":22},"星型联网拓扑安装维护工作量大、中央节点负担重、分布处理能力低",{"key":24,"text":245,"correct":32},"总线型联网拓扑不便扩充、维护难",{"key":27,"text":223,"correct":22},{"key":30,"text":248,"correct":32},"环型联网拓扑维护难、分支节点故障查找难","AC",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":33,"analysis":34},965291,"消防设备电源监控系统是用于监控消防设备电源工作状态，在电源发生（ ）等故障时能发出报警信号的监控系统。",[254,256,258,260],{"key":20,"text":255,"correct":22},"断电",{"key":24,"text":257,"correct":22},"过压",{"key":27,"text":259,"correct":22},"过流",{"key":30,"text":261,"correct":32},"短路",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":133,"analysis":34},965292,"关于消防设备电源状态监控器工作状态指示灯的说法正确的有（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"系统交流电源故障时，黄色主电故障指示灯点亮",{"key":24,"text":269,"correct":22},"系统备用电源故障时，黄色备电故障指示灯点亮",{"key":27,"text":271,"correct":32},"监控器由交流电源供电时，黄色备电故障指示灯点亮",{"key":30,"text":273,"correct":32},"监控器由备用电源供电时，黄色主电故障指示灯点亮",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":33,"analysis":34},965293,"监控器检测到哪些故障时，黄色故障指示灯点亮？（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":22},"总线设备离线",{"key":24,"text":281,"correct":22},"通讯故障",{"key":27,"text":283,"correct":22},"本身故障",{"key":30,"text":285,"correct":32},"互感器故障",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":95,"analysis":34},965294,"火灾报警控制器在只接收到火警信息后，在液晶显示屏会显示哪些信息，下列哪些说法是正确的。（ ）",[290,292,294,296],{"key":20,"text":291,"correct":22},"报警设备位置信息",{"key":24,"text":293,"correct":22},"火警信息",{"key":27,"text":295,"correct":32},"做障信息",{"key":30,"text":297,"correct":22},"火灾报警时间",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":108,"analysis":34},965295,"火灾报警控制器接收到火灾报警信号后，下列哪些说法是正确的。（ ）",[302,304,306,308],{"key":20,"text":303,"correct":22},"发出声、光报警信号；",{"key":24,"text":305,"correct":32},"广播控制器启动；",{"key":27,"text":307,"correct":22},"火警指示灯应点亮；",{"key":30,"text":309,"correct":22},"火灾探测器部位，记录火灾报警时间",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":213,"analysis":34},965296,"不同品牌、不同厂家的产品，其火灾报警控制器程序的编程方法各不相同。一般可分为（ ）",[314,316,318,320],{"key":20,"text":315,"correct":32},"与逻辑编程",{"key":24,"text":317,"correct":22},"现场编程",{"key":27,"text":319,"correct":22},"后台编程",{"key":30,"text":321,"correct":32},"或一逻辑编程",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":95,"analysis":34},965297,"火灾报警控制器按监控区域分可分为（ ）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"集中型",{"key":24,"text":329,"correct":22},"区域型",{"key":27,"text":331,"correct":32},"集中区域型",{"key":30,"text":333,"correct":22},"控制中心报警系统",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":349,"analysis":34},965298,"防排烟系统中建筑消防设施运行状态信息包括：（ ）",[338,340,342,344,346],{"key":20,"text":339,"correct":22},"系统的手动、自动工作状态；",{"key":24,"text":341,"correct":22},"防烟排烟风机电源的工作状态；",{"key":27,"text":343,"correct":22},"风机、电动防火阀、电动排烟防火阀、常闭送风口、排烟阀的正常工作状态和动作状态；",{"key":30,"text":345,"correct":32},"楼梯间、前室及合用前室的余压信息；",{"key":347,"text":348,"correct":22},"E","电动排烟窗、电动挡烟垂壁的正常工作状态和动作状态。","ABCE",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":364,"analysis":34},965299,"消火栓系统中建筑消防设施运行状态信息包括：（ ）",[354,356,358,360,362],{"key":20,"text":355,"correct":22},"消防水泵电源的工作状态；",{"key":24,"text":357,"correct":22},"消防水泵的启、停状态和故障状态；",{"key":27,"text":359,"correct":22},"消防水箱（池）水位、管网压力报瞥信息；",{"key":30,"text":361,"correct":22},"消火栓按钮的报警信息；",{"key":347,"text":363,"correct":32},"消防泵的手动、自动状态。","ABCD",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":379,"analysis":34},965300,"预作用系统由（ ）等组成。",[369,371,373,375,377],{"key":20,"text":370,"correct":32},"开式喷头",{"key":24,"text":372,"correct":22},"供水设施",{"key":27,"text":374,"correct":22},"预作用阀组",{"key":30,"text":376,"correct":22},"充气设备",{"key":347,"text":378,"correct":22},"火灾探测器","BCDE",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":95,"analysis":34},965301,"按下火灾报警控制器上的“自检”键，控制器上所有（ ）均应能全部进入自检状态，自检完成后，应能自动退出自检状态。",[384,386,388,390,392],{"key":20,"text":385,"correct":22},"指示灯",{"key":24,"text":387,"correct":22},"报警声",{"key":27,"text":389,"correct":32},"消防应急广播",{"key":30,"text":391,"correct":22},"液晶显示器",{"key":347,"text":393,"correct":32},"图形显示装置",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":33,"analysis":34},965302,"气体灭火装置启动及喷放各阶段的联动控制及系统的反馈信号，应反馈至消防联动控制器。系统的联动反馈信号应包括下列内容（ ）。",[398,400,402,404,406],{"key":20,"text":399,"correct":22},"气体灭火控制器直接连接的火灾探测器的报警信号；",{"key":24,"text":401,"correct":22},"选择阀的动作信号；",{"key":27,"text":403,"correct":22},"压力开关的动作信号；",{"key":30,"text":405,"correct":32},"管网压力信号；",{"key":347,"text":407,"correct":32},"系统的启停信号。",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":417,"analysis":34},965303,"点型感烟火灾探测器的安装，就符合的要求有：（ ）。 A.在宽度小于3m的内走道顶栅上，点型感烟探测器相距不应超过10m B.探测器周围水平距离0.5m内，不应有遮挡物 C.探测器至空调送风口最近边的水平距离，不应小于0.5m D.探测器需倾斜安装时，倾斜角不应大于45°",[412,413,414,415,416],{"key":20,"text":20,"correct":32},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":22},{"key":347,"text":347,"correct":32},"BD",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":249,"analysis":34},965304,"不宜选用点型离子感烟探测器的场所是：（ ）。 A.气流速度大于5m\u002Fs B.有电气火灾危险的 C.有大量粉尘、水雾滞留的 D.高海拔地区",[422,423,424,425,426],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":32},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":32},{"key":347,"text":347,"correct":32},{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":33,"analysis":34},965305,"下列关于报警阀组件共性要求检测内容及要求说法中正确的是（ ）。 A.检查报警阀组外观标志，标识清晰、内容详实，符合产品生产技术标准要求，并注明系统名称和保护区域，压力表显示符合设定值 B.系统控制阀以及报警管路控制阀全部开启，并用锁具固定手轮，具有明显的启闭标志 C.报警阀组的相关组件灵敏可靠 D.报警阀组充气装置外观标志，标识清晰，工作正常",[431,432,433,434,435],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":32},{"key":347,"text":347,"correct":32},{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":364,"analysis":34},965306,"（ ）的控制设备当釆用总线编码模块控制时，还应在消防控制室设置手动直接控制装置。",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"消防水泵",{"key":24,"text":443,"correct":22},"正压送风机",{"key":27,"text":445,"correct":22},"排烟风机",{"key":30,"text":447,"correct":22},"补风机",{"key":347,"text":449,"correct":32},"防火卷帘",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":464,"analysis":34},965307,"火灾报警与消防联动控制系统的布线不宜选择（ ）。",[454,456,458,460,462],{"key":20,"text":455,"correct":32},"铜芯电缆",{"key":24,"text":457,"correct":22},"铝芯电缆",{"key":27,"text":459,"correct":32},"铜芯绝缘电线",{"key":30,"text":461,"correct":22},"铝芯绝缘电线",{"key":347,"text":463,"correct":22},"同轴电缆","BDE",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":249,"analysis":34},965308,"火灾报警与消防联动控制系统的布线可选择（ ）。",[469,470,471,472,473],{"key":20,"text":455,"correct":22},{"key":24,"text":457,"correct":32},{"key":27,"text":459,"correct":22},{"key":30,"text":461,"correct":32},{"key":347,"text":463,"correct":32},{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":349,"analysis":34},965309,"火灾自动报警系统安装布线时，当线槽敷设时，应在下列部位设置吊点或支点：（ ）。",[478,480,482,484,486],{"key":20,"text":479,"correct":22},"线槽始端、终端及接头处；",{"key":24,"text":481,"correct":22},"距接线盒0.2m处；",{"key":27,"text":483,"correct":22},"线槽转角或分支处；",{"key":30,"text":485,"correct":32},"直线段不大于2m处。",{"key":347,"text":487,"correct":22},"直线段不大于3m处。",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":364,"analysis":34},965310,"消防产品，是指专门用于（ ）的产品。",[492,494,496,498,500],{"key":20,"text":493,"correct":22},"火灾预防",{"key":24,"text":495,"correct":22},"灭火救援",{"key":27,"text":497,"correct":22},"火灾防护",{"key":30,"text":499,"correct":22},"火灾避难、逃生",{"key":347,"text":501,"correct":32},"维护公共安全",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":516,"analysis":34},965311,"故障电弧探测器的设置位置及安装应符合下列要求：（ ）。",[506,508,510,512,514],{"key":20,"text":507,"correct":32},"应以设置在低压配电系统首端为基本原则，宜设置在第一级配电箱（柜）的出线端，在供电线路泄露电流大于500mA时，宜在下一级配电柜（箱）设置；",{"key":24,"text":509,"correct":32},"应设置在电缆接头、端子、重点发热部件等部位；",{"key":27,"text":511,"correct":32},"保护对象为1000V及以下的配电线路，应釆用接触式布置；",{"key":30,"text":513,"correct":22},"探测器的额定工作电流应与被探测线路的工作电流相匹配，其保护线路的长度不宜大于100m；",{"key":347,"text":515,"correct":22},"探测器应可靠固定，防止松动或位移。","DE",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":379,"analysis":34},965312,"测温式电气火灾监控探测器的传感器设置位置及安装应符合下列要求：（ ）。",[521,522,524,526,528],{"key":20,"text":507,"correct":32},{"key":24,"text":523,"correct":22},"测温式电气火灾监控探测器应设置在电缆接头、端子、重点发热部件等部位；",{"key":27,"text":525,"correct":22},"保护对象为1000V及以下的配电线路，测温式电气火灾监控探测器应釆用接触式布置；",{"key":30,"text":527,"correct":22},"光栅光纤测温式电气火灾监控探测器应直接设置在保护对象的表面；",{"key":347,"text":529,"correct":22},"探测器以及传感器应可靠固定，防止松动或位移。",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":364,"analysis":34},965313,"剩余电流式电气火灾监控探测器的传感器设置位置及安装应符合下列要求：（ ）。",[534,535,537,539,541],{"key":20,"text":507,"correct":22},{"key":24,"text":536,"correct":22},"剩余电流式电气火灾监控探测器报警值应与探测电气线路相适宜，报警值宜为300mA-500mA；",{"key":27,"text":538,"correct":22},"配电回路的相线和中性线应按同一正方向均匀穿过剩余电流传感器；",{"key":30,"text":540,"correct":22},"保护地线（PE线）不得穿过剩余电流传感器；",{"key":347,"text":542,"correct":32},"应设置在电缆接头、端子、重点发热部件等部位。",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":364,"analysis":34},965314,"消防电梯的设置应符合下列要求：（ ）。",[547,549,551,553,555],{"key":20,"text":548,"correct":22},"消防电梯轿厢内应设专用电话，通话应正常。",{"key":24,"text":550,"correct":22},"应在首层设供消防队员专用的操作按钮，用透明罩保护。",{"key":27,"text":552,"correct":22},"消防电梯的井底应设排水设施，排水量不应小于10L\u002FS。",{"key":30,"text":554,"correct":22},"消防电梯轿厢内装修应釆用不燃材料。",{"key":347,"text":556,"correct":32},"消防电梯轿厢内应设置火灾探测器",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":95,"analysis":34},965315,"点型火灾探测器的保护半径与建筑物的（ ）有关。",[561,563,565,567],{"key":20,"text":562,"correct":22},"地面面积",{"key":24,"text":564,"correct":22},"房间高度",{"key":27,"text":566,"correct":32},"装修材料",{"key":30,"text":568,"correct":22},"屋顶坡度",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":417,"analysis":34},965316,"下列说法哪些是正确的（ ）。",[573,575,577,579],{"key":20,"text":574,"correct":32},"火灾自动报警系统应设置火灾声光警报器，并应在确认火灾后启动火灾防火分区内的所有火灾声光警报器",{"key":24,"text":576,"correct":22},"消防联动控制器应具有发出联动控制信号强制所有电梯停于首层或电梯转换层的功能",{"key":27,"text":578,"correct":32},"在疏散通道上设置的防火卷帘的任一侧距卷帘纵深0.5-5m内应设置不少于2只专门用于联动防火卷帘的感烟火灾探测器",{"key":30,"text":580,"correct":22},"排烟风机入口处的总管上设置的280℃排烟防火阀在关闭后应直接联动控制风机停止",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":133,"analysis":34},965317,"报警区域可根据（ ）划分。",[585,587,589,591],{"key":20,"text":586,"correct":22},"防火分区",{"key":24,"text":588,"correct":22},"防烟分区",{"key":27,"text":590,"correct":32},"楼层",{"key":30,"text":592,"correct":32},"建筑面积",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":33,"analysis":34},965318,"根据《火灾自动报警系统施工及验收规范》，火灾探测器（含可燃气体探测器）和手动火灾报警按钮，应按下列哪些要求进行模拟火灾响应（可燃气体报警）和故障信号检验。（ ）",[597,599,601,603],{"key":20,"text":598,"correct":22},"实际安装数量在100只以下者，抽验20只（每个回路都应抽验）",{"key":24,"text":600,"correct":22},"实际安装数量超过100只，每个回路按实际安装数量10%-20%的比例抽检，但抽检总数不应少于20只",{"key":27,"text":602,"correct":22},"被检查的火灾探测器的类别、型号、适用场所、安装高度、保护半径、保护面积和探测器的间距等均应符合设计要求",{"key":30,"text":604,"correct":32},"各装置的安装位置、型号、数量、类别及安装质量应符合设计要求",{"id":606,"libraryId":5,"type":15,"typeLabel":16,"stem":607,"options":608,"answer":108,"analysis":34},965319,"火灾自动报警系统由火灾探测触发装置、火灾报警装置、火灾警报装置以及具有其他辅助功能的装置组成，按其应用范围可分为：（ ）。",[609,611,613,615],{"key":20,"text":610,"correct":22},"区域报警系统",{"key":24,"text":612,"correct":32},"城市报警系统",{"key":27,"text":614,"correct":22},"集中报警系统",{"key":30,"text":333,"correct":22},{"id":617,"libraryId":5,"type":15,"typeLabel":16,"stem":618,"options":619,"answer":95,"analysis":34},965320,"下列系统中，属于闭式系统的有：（ ）。",[620,622,624,626],{"key":20,"text":621,"correct":22},"湿式自动喷水灭火系统",{"key":24,"text":623,"correct":22},"干式自动喷水灭火系统",{"key":27,"text":625,"correct":32},"水幕系统",{"key":30,"text":627,"correct":22},"作用自动喷水灭火系统",{"id":629,"libraryId":5,"type":15,"typeLabel":16,"stem":630,"options":631,"answer":133,"analysis":34},965321,"火灾探测器的选择，下列哪些是正确的（ ）。",[632,634,636,638],{"key":20,"text":633,"correct":22},"对火灾初期有阴燃阶段，产生大量的烟和少量的热，很少或没有火焰辐射的场所，应选择感烟探测器",{"key":24,"text":635,"correct":22},"对火灾发展迅速，可产生大量热、烟和火焰辐射的场所，可选择感温探测器、感烟探测器、火焰探测器或其组合",{"key":27,"text":637,"correct":32},"对火灾发展迅速，有强烈的火焰辐射和少量的烟、热的场所，应选择感烟探测器",{"key":30,"text":639,"correct":32},"对使用、生产或聚集可燃气体可燃蒸汽的场所，应选择感温探测器",[641,645,648,651,654,657],{"id":642,"name":643,"category":7,"favorite":644},1,"领导干部任职前廉政法规知识测试题",92,{"id":646,"name":647,"category":7,"favorite":642},595,"建筑结构与设备",{"id":649,"name":650,"category":7,"favorite":642},715,"招标采购专业知识与法律法规",{"id":652,"name":653,"category":7,"favorite":642},848,"市政方向-通用基础",{"id":655,"name":656,"category":7,"favorite":8},534,"BIM工程师",{"id":658,"name":656,"category":7,"favorite":8},535]