[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-20":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":601},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,20,50,2716,[13,34,46,58,66,78,90,102,114,126,138,149,160,172,184,196,206,218,230,242,254,266,278,290,302,314,326,338,350,362,374,386,398,410,422,434,446,458,470,481,491,502,513,522,532,544,555,567,577,589],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},965170,1,"单选题","电动机反转可能引起的结果正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","系统不出水",false,{"key":24,"text":25,"correct":26},"B","能出水，但出水压力变小",true,{"key":28,"text":29,"correct":22},"C","反向打水",{"key":31,"text":32,"correct":22},"D","都不对","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},965171,"消防水泵不能现场手动启动的原因不正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"控制柜未在自动状态",{"key":24,"text":41,"correct":22},"空气开关未合闸",{"key":28,"text":43,"correct":26},"进水阀门关闭",{"key":31,"text":45,"correct":22},"电源缺相",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},965172,"消防水泵吸水管口当采用旋流防止器时，在消防水池最低有效水位下的淹没深度不应小于（ ）mm。",[50,52,54,56],{"key":20,"text":51,"correct":26},"200",{"key":24,"text":53,"correct":22},"400",{"key":28,"text":55,"correct":22},"600",{"key":31,"text":57,"correct":22},"800",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},965173,"消防水泵吸水管喇叭口在消防水池最低有效水位下的淹没深度不应小于（ ）mm，当采用旋流防止器时，淹没深度不应小于200mm。",[62,63,64,65],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":22},{"key":28,"text":55,"correct":26},{"key":31,"text":57,"correct":22},{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":24,"analysis":33},965174,"当消防水泵吸水口处无吸水井时，吸水口处应设置（ ）。",[70,72,74,76],{"key":20,"text":71,"correct":22},"底阀",{"key":24,"text":73,"correct":26},"旋流防止器",{"key":28,"text":75,"correct":22},"止回阀",{"key":31,"text":77,"correct":22},"倒流防止器",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":28,"analysis":33},965175,"气压水罐的调节容积应根据稳压泵启泵次数不大于（ ）次\u002Fh计算确定。",[82,84,86,88],{"key":20,"text":83,"correct":22},"5",{"key":24,"text":85,"correct":22},"10",{"key":28,"text":87,"correct":26},"15",{"key":31,"text":89,"correct":22},"20",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":28,"analysis":33},965176,"稳压泵的下限启泵压力应大于自动启动消防泵的低压压力开关的压力值（ ）Mpa。",[94,96,98,100],{"key":20,"text":95,"correct":22},"0.05-1.0",{"key":24,"text":97,"correct":22},"0.05-1.5",{"key":28,"text":99,"correct":26},"0.07-0.1",{"key":31,"text":101,"correct":22},"0.07-1.5",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":20,"analysis":33},965177,"消防给水系统管网的正常泄漏量应根据管道材质、接口形式等确定，当没有管网泄漏量数据时，稳压泵的设计流量宜按消防给水设计流量的1%-3%计，且不宜小于（ ）L\u002Fs。",[106,108,110,112],{"key":20,"text":107,"correct":26},"1",{"key":24,"text":109,"correct":22},"2",{"key":28,"text":111,"correct":22},"3",{"key":31,"text":113,"correct":22},"4",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":31,"analysis":33},965178,"当采用电动机驱动的消防水泵时，应选择电动机（ ）的消防水泵。",[118,120,122,124],{"key":20,"text":119,"correct":22},"湿式安装",{"key":24,"text":121,"correct":22},"立式安装",{"key":28,"text":123,"correct":22},"整体安装",{"key":31,"text":125,"correct":26},"干式安装",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":28,"analysis":33},965179,"消防水泵按在系统中的作用分可分为（ ）。",[130,132,134,136],{"key":20,"text":131,"correct":22},"消防泵",{"key":24,"text":133,"correct":22},"水幕泵",{"key":28,"text":135,"correct":26},"传输泵",{"key":31,"text":137,"correct":22},"喷淋泵",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":33},965180,"消防水泵按传动轴位置分可分为（ ）。",[142,144,146,148],{"key":20,"text":143,"correct":22},"电动泵",{"key":24,"text":145,"correct":26},"立式泵",{"key":28,"text":147,"correct":22},"汽油机泵",{"key":31,"text":137,"correct":22},{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":31,"analysis":33},965181,"消防水泵按供水分区分可分为（ ）。",[153,154,156,158],{"key":20,"text":131,"correct":22},{"key":24,"text":155,"correct":22},"卧式泵",{"key":28,"text":157,"correct":22},"轴流泵",{"key":31,"text":159,"correct":26},"中区泵",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":24,"analysis":33},965182,"消防水泵按所服务的系统分可分为（ ）。",[164,166,168,170],{"key":20,"text":165,"correct":22},"工作泵",{"key":24,"text":167,"correct":26},"消火栓泵",{"key":28,"text":169,"correct":22},"单出口消防泵",{"key":31,"text":171,"correct":22},"单级泵",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":31,"analysis":33},965183,"如果闭式泡沬-水喷淋系统仅测试联动控制功能，使用（ ）。",[176,178,180,182],{"key":20,"text":177,"correct":22},"末端试水装置",{"key":24,"text":179,"correct":22},"楼层试水阀",{"key":28,"text":181,"correct":22},"报警阀",{"key":31,"text":183,"correct":26},"泡沬液试验阀",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":20,"analysis":33},965184,"对于泡沫-水喷淋系统联动控制功能测试的描述不正确的是（ ）。",[188,190,192,194],{"key":20,"text":189,"correct":26},"打开泡沫液试验阀，压力开关应动作",{"key":24,"text":191,"correct":22},"压力水经延迟器进入报警管路，水力警铃应报警，压力开关应动作，并启动消防水泵",{"key":28,"text":193,"correct":22},"同时报警管路一部分水进入压力释放阀",{"key":31,"text":195,"correct":22},"压力释放阀动作后，泡沫液控制阀自动开启，向系统供给泡沫液，系统试验阀随即有泡沫混合液流出",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":28,"analysis":33},965185,"闭式泡沫-水喷淋系统要求，在系统流量为（ ）L\u002Fs至最大流量区间内，系统的混合比应满足设计要求。",[200,201,203,205],{"key":20,"text":113,"correct":22},{"key":24,"text":202,"correct":22},"6",{"key":28,"text":204,"correct":26},"8",{"key":31,"text":85,"correct":22},{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":20,"analysis":33},965186,"全淹没高倍数泡沫灭火系统和自动控制的固定式局部应用系统的启动方式分为自动控制、手动控制和机械应急手动控制三种。联动控制功能测试主要针对（ ）启动方式。",[210,212,214,216],{"key":20,"text":211,"correct":26},"自动控制",{"key":24,"text":213,"correct":22},"手动控制",{"key":28,"text":215,"correct":22},"机械应急手动控制",{"key":31,"text":217,"correct":22},"机械控制",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":31,"analysis":33},965187,"关于泡沫喷雾系统联动控制功能测试的测试内容说法不正确的是（ ）。",[222,224,226,228],{"key":20,"text":223,"correct":22},"首先将泡沫喷雾系统控制盘的控制方式置于“自动”位置",{"key":24,"text":225,"correct":22},"模拟首个火灾探测器的报警信号，当泡沫喷雾系统控制盘接收到第一个火警信号后，控制盘立即发出声、光警报",{"key":28,"text":227,"correct":22},"模拟第二个火灾报警信号，系统控制盘在接收到第二个火灾探测器的火灾信号后，应发出联动指令，经过延时（根据需要预先设定）后自动打开电磁型驱动装置及保护区对应的分区控制阀",{"key":31,"text":229,"correct":26},"模拟第二个火灾报警信号，系统控制盘在接收到第二个火灾探测器的火灾信号后，应发出联动指令，经过延时（根据需要预先设定）后启动泡沬消防水泵、比例混合装置、分区阀及相关自动控制阀门，向防护区内喷洒泡沫灭火",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":20,"analysis":33},965188,"下列选顶中，气体灭火系统气体灭火控制器的安装不符合要求的是：（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":26},"在墙上安装时，其底边距地（楼）面高度宜为1.2?1.4m，其靠近门轴的侧面距墙不应小于0.5m，正面操作距离不应小于1.2m；",{"key":24,"text":237,"correct":22},"气体灭火控制落地安装时，其底边宜高出地（楼）面0.1-0.2m",{"key":28,"text":239,"correct":22},"控制器应安装牢固，不应倾斜",{"key":31,"text":241,"correct":22},"安装在轻质墙上时，应采取加固措施",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":28,"analysis":33},965189,"对于灭火剂输送管道水压强度试验的说法不正确的是（ ）。",[246,248,250,252],{"key":20,"text":247,"correct":22},"对高压二氧化碳灭火系统，试验压力应取15.0MPa",{"key":24,"text":249,"correct":22},"对低压二氧化碳灭火系统，试验压力应取4.0MPa",{"key":28,"text":251,"correct":26},"进行水压强度试验时，以不大于0.5MPa\u002Fs的升压速率缓慢升压至试验压力。保压l0min，检查管道各处无渗漏，无变形为合格",{"key":31,"text":253,"correct":22},"当水压强度试验条件不具备时，可采用气压强度试验代替。",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":31,"analysis":33},965190,"气体灭火系统的气体灭火控制器的安装不符合要求的是：（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":22},"控制器的主电源应有明显的永久性标志，并应直接与消防电源连接，严禁使用电源插头。控制器与其外接备用电源之间应直接连接",{"key":24,"text":261,"correct":22},"控制器的接地应牢固，幷有明显的永久性标志",{"key":28,"text":263,"correct":22},"气体灭火控制器在墙上安装时，其底边距地（楼）面高度宜为1.3?1.5m，其靠近门轴的侧面距墙不应小于0.5m，正面操作距离不应小于1.2m",{"key":31,"text":265,"correct":26},"气体灭火控制器落地安装时，其底边宜高出地（楼）面0.3?0.5m",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":31,"analysis":33},965191,"引入控制器的电缆或导线，不符合要求的是：（ ）",[270,272,274,276],{"key":20,"text":271,"correct":22},"配线应整齐，不宜交叉，并应固定牢靠",{"key":24,"text":273,"correct":22},"电缆芯线和所配导线的端部，均应标明编号，并与图样一致",{"key":28,"text":275,"correct":22},"字迹应清晰且不易褪色；端子板的每个接线端，接线不得超过2根",{"key":31,"text":277,"correct":26},"电缆芯和导线，应留有不小于300mm的余量",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":28,"analysis":33},965192,"以下不符合灭火剂储存装置安装要求的是：（ ）",[282,284,286,288],{"key":20,"text":283,"correct":22},"集流管外表面宜涂红色油漆",{"key":24,"text":285,"correct":22},"集流管应固定在支、框架上。支、框架应固定牢靠，并做防腐处理",{"key":28,"text":287,"correct":26},"连接储存容器与集流管间的单向阀的流向指示箭头应指向空气流动方向",{"key":31,"text":289,"correct":22},"集流管上的泄压装置的泄压方向不应朝向操作面",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":31,"analysis":33},965193,"灭火剂输送管道采用螺纹连接时，下面不符合规定的有：（ ）",[294,296,298,300],{"key":20,"text":295,"correct":22},"管材宜采用机械切割",{"key":24,"text":297,"correct":22},"螺纹不得有缺纹、断纹等现象",{"key":28,"text":299,"correct":22},"螺纹连接的密封材料应均匀附着在管道的螺纹部分，拧紧螺纹时，不得将填料挤入管道内",{"key":31,"text":301,"correct":26},"安装后的螺纹根部应无外露螺纹",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":24,"analysis":33},965194,"灭火剂输送管道采用法兰连接时下列不符合规定的是：（ ）",[306,308,310,312],{"key":20,"text":307,"correct":22},"拧紧后，凸出螺母的长度不应大于螺杆直径的1\u002F2且保证有不少于2条外露螺纹",{"key":24,"text":309,"correct":26},"安装后的螺纹根部应有2-3条外露螺纹",{"key":28,"text":311,"correct":22},"衬垫不得凸入管内，其外边缘宜接近螺栓，不得放双垫或偏垫",{"key":31,"text":313,"correct":22},"连接法兰的螺栓，直径和长度应符合标准",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":28,"analysis":33},965195,"灭火剂输送管道连接不符合规定的是：（ ）",[318,320,322,324],{"key":20,"text":319,"correct":22},"当水平管道改变方向时，应增设防晃支架。",{"key":24,"text":321,"correct":22},"管道末端应采用防晃支架固定，支架与末端喷喷间的距离不应大于500mm",{"key":28,"text":323,"correct":26},"公称直径小于50mm的主干管道，垂直方向和水平方向至少应各安装1个防晃支架",{"key":31,"text":325,"correct":22},"当穿过建筑物楼层时，每层应设1个防晃支架。",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":31,"analysis":33},965196,"灭火剂输送管道水压强度试验压力取值不符合规定的是：（ ）",[330,332,334,336],{"key":20,"text":331,"correct":22},"对高压二氧化碳灭火系统，应取15.0MPa",{"key":24,"text":333,"correct":22},"对低压二氧化碳灭火系统，应取4.0MPa",{"key":28,"text":335,"correct":22},"对IG541混合气体灭火系统，应取13.0MPa",{"key":31,"text":337,"correct":26},"对卤代烷1301灭火系统和七氟丙烷灭火系统，应取15.0MPa",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":24,"analysis":33},965197,"灭火剂输送管道气压强度试验压力取值不符合规定的是：（ ）",[342,344,346,348],{"key":20,"text":343,"correct":22},"二氧化碳灭火系统取80%水压强度试验压力",{"key":24,"text":345,"correct":26},"卤代烷1301灭火系统和七氟丙烷灭火系统，应取15.0MPa",{"key":28,"text":347,"correct":22},"IG 541混合气体灭火系统取10.5MPa",{"key":31,"text":349,"correct":22},"卤代烷1301灭火系统和七氟丙烷灭火系统取1.15倍最大工作压力",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":24,"analysis":33},965198,"关于灭火剂输送管道气压强度试验，下列不符合规定的是：（ ）",[354,356,358,360],{"key":20,"text":355,"correct":22},"试验前，必须用加压介质进行预试验，预试验压力宜为0.2MPa",{"key":24,"text":357,"correct":26},"试验时，以不大于0.5MPa\u002Fs的升压速率缓慢升压至试验压力。保压5min，检查管道各处无渗漏，无变形为合格。",{"key":28,"text":359,"correct":22},"试验时，应逐步缓慢増加压力，当压力升至试验压力的50%时，如未发现异状或泄露，继续按试验压力的10%逐级升压，每级升压3min，直至试验压力。",{"key":31,"text":361,"correct":22},"保压检查管道各处无变形、无泄漏为合格。",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":24,"analysis":33},965199,"关于灭火剂输送管道强度试验和气密性试验的说法不符合要求的是（ ）。",[366,368,370,372],{"key":20,"text":367,"correct":22},"灭火剂输送管道经水压强度试验合格后还应进行气密性试验",{"key":24,"text":369,"correct":26},"灭火剂输送管道经气压强度试照合格且在试验后未拆卸过的管道还应进行气密性试脸",{"key":28,"text":371,"correct":22},"气压强度试验和气密性试验必须采取有效的安全措施",{"key":31,"text":373,"correct":22},"加压介质可采用空气或氮气",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":20,"analysis":33},965200,"灭火剂输送管道的吹扫不符合规定的是（ ）。",[378,380,382,384],{"key":20,"text":379,"correct":26},"灭火剂输送管道在气密性试验合格后，或水压强度试验前，应进行吹扫。",{"key":24,"text":381,"correct":22},"吹扫管道可采用压缩空气或氨气",{"key":28,"text":383,"correct":22},"吹扫时，管道末端的气体流速不应小于20m\u002Fs",{"key":31,"text":385,"correct":22},"采用白布检查，直至无铁锈、尘土、水渍及其他异物出现",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":28,"analysis":33},965202,"固定消防炮灭火系统喷射功能试验结果不符合要求的是：（ ）",[390,392,394,396],{"key":20,"text":391,"correct":22},"水炮、水幕、泡沬炮的实际工作压力不应小于相应的设计工作压力。",{"key":24,"text":393,"correct":22},"水炮、泡沫炮、干粉炮的水平、俯仰回转角应符合设计要求，带直流喷雾转换功能的消防水炮的喷雾角应符合设计要求",{"key":28,"text":395,"correct":26},"保护水幕喷头的喷射角度应符合设计要求",{"key":31,"text":397,"correct":22},"泡沫炮系统的泡抹比例、混合装置提供的混合液的混合比应符合设计要求",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":24,"analysis":33},965203,"以下哪项是电气火灾监控系统监控设备接地要求：（ ）",[402,404,406,408],{"key":20,"text":403,"correct":22},"设备的主电源应有明显的永久性标识，并应直接与消防电源连接",{"key":24,"text":405,"correct":26},"设备的接地应牢固，并有明显的永久性标识",{"key":28,"text":407,"correct":22},"设备的主电源严禁使用电源插头与消防电源连接",{"key":31,"text":409,"correct":22},"电源安装应符合产品使用说明书的要求",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":31,"analysis":33},965204,"以下哪项不符合电气火灾监控系统监控探测器安装要求？（ ）",[414,416,418,420],{"key":20,"text":415,"correct":22},"在探测器周围应适当留出更换和标定的空间",{"key":24,"text":417,"correct":22},"剩余电流式探测器负载侧的中性线不应与其他回路共用，且不应重复接地",{"key":28,"text":419,"correct":22},"测温式探测器应采用产品配套固定装置固定在保护对象上",{"key":31,"text":421,"correct":26},"线缆应留有不小于150mm的余量",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":31,"analysis":33},965205,"以下哪项不符合电气火灾监控系统传感器安装要求？（ ）",[426,428,430,432],{"key":20,"text":427,"correct":22},"传感器与裸带电导体应保证安全距离，金属外壳的传感器应有安全接地；",{"key":24,"text":429,"correct":22},"传感器应独立支承或固定，安装牢固，并应采取防潮、防腐蚀等措施；",{"key":28,"text":431,"correct":22},"传感器输出回路的连接线，应使用截面积不小于1.0mm2的双绞铜芯导线，并应留有不小于150mm的余量，其端部应有明显标识；",{"key":31,"text":433,"correct":26},"传感器的安装可以破坏被监控线路的完整性，可以增加线路接点。",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":28,"analysis":33},965206,"电气火灾监控设备报警功能检测不符合要求的是（ ）。",[438,440,442,444],{"key":20,"text":439,"correct":22},"监控设备与现场部件之间的连线断路时，监控设备应在100s内显示故障部件的地址注释信息",{"key":24,"text":441,"correct":22},"监控设备与现场部件之间的连线短路时，监控设备应在100s内显示故障部件的地址注释信息",{"key":28,"text":443,"correct":26},"探测器发出报警信号后，监控设备应在100s内发出监控报警声、光信号，并记录报警时间，监控设备应显示发出报警信号部件的地址注释信息",{"key":31,"text":445,"correct":22},"监控设备应能手动消除报警声信号",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":28,"analysis":33},965207,"关于电气火灾监控设备报警功能不符合要求的有：（ ）",[450,452,454,456],{"key":20,"text":451,"correct":22},"监控设备应能对指示灯、显示器和音响器件进行功能自检",{"key":24,"text":453,"correct":22},"监控设备应根据不同的使用对象设置不同的操作级别",{"key":28,"text":455,"correct":26},"监控设备应能自动消除报警声信号",{"key":31,"text":457,"correct":22},"监控设备的连接、探测器的监测区域恢复正常，监控设备应能对监控设备的报警状态复位，消除监控设备的声、光报警信号",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":31,"analysis":33},965208,"不符合剩余流式电气火灾监控探测器监控报警功能要求的是（ ）。",[462,464,466,468],{"key":20,"text":463,"correct":22},"探测器监测区域的剩余电流达到报警设定值时，探测器的报警确认灯应在30s内点亮并保持；",{"key":24,"text":465,"correct":22},"监控设备应发出监控报警声、光信号，并记录报警时间；",{"key":28,"text":467,"correct":22},"监控设备应显示发出报警信号部件的地址注释信息。",{"key":31,"text":469,"correct":26},"探测器监测区域的温度达到报警设定值时，探测器的报警确认灯应在40s内点亮并保持；",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":28,"analysis":33},965209,"不符合电气火灾监控系统监控设备安装要求的是：（ ）",[474,476,478,480],{"key":20,"text":475,"correct":22},"设备应安装牢固，不应倾斜",{"key":24,"text":477,"correct":22},"落地安装时：设备底边宜高出地（楼）面0.1-0.2m",{"key":28,"text":479,"correct":26},"采用壁挂方式安装时；其主显示屏高度宜为1.3-1.5m，其靠近门轴的侧面距墙不应小于0.5m，正面操作距离不应小于1.2m",{"key":31,"text":241,"correct":22},{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":24,"analysis":33},965210,"下列不符合电气火灾监控系统监控设备的安装要求的是：（ ）",[485,486,488,490],{"key":20,"text":475,"correct":22},{"key":24,"text":487,"correct":26},"落地安装时：设备底边宜高出地（楼）面0.2-0.3m",{"key":28,"text":489,"correct":22},"采用壁挂方式安装时；其主显示屏高度宜为1.5-1.8m，其靠近门轴的侧面距墙不应小于0.5m，正面操作距离不应小于1.2m",{"key":31,"text":241,"correct":22},{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":28,"analysis":33},965211,"以下不符合电气火灾监控系统监控设备引入线缆要求的是：（ ）",[495,496,498,500],{"key":20,"text":271,"correct":22},{"key":24,"text":497,"correct":22},"线缆芯线的端部，均应标明编号，并与图样一致，字迹应清晰且不易褪色",{"key":28,"text":499,"correct":26},"端子板的每个接线端，接线不得超过1根",{"key":31,"text":501,"correct":22},"线缆应留有不小于200mm的余量",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":31,"analysis":33},965212,"下面不符合电气火灾监控系统监控设备引入线缆要求的是：（ ）",[506,508,510,512],{"key":20,"text":507,"correct":22},"线缆穿管、槽盒后，应将管口、槽口封堵",{"key":24,"text":509,"correct":22},"线缆应绑扎成束",{"key":28,"text":511,"correct":22},"端子板的每个接线端，接线不得超2根",{"key":31,"text":421,"correct":26},{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":20,"analysis":33},965213,"不符合测温式电气火灾监控探测器监控报警功能要求的是（ ）。",[517,518,519,520],{"key":20,"text":463,"correct":26},{"key":24,"text":465,"correct":22},{"key":28,"text":467,"correct":22},{"key":31,"text":521,"correct":22},"探测器监测区域的温度达到报警设定值时，探测器的报警确认灯应在40s内点亮幷保持；",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":24,"analysis":33},965214,"不符合电气火灾监控系统故障电弧探测器监控报警功能要求的有（ ）。",[526,528,530,531],{"key":20,"text":527,"correct":22},"探测器监测区域单位时间故障电弧的数量未达到报警设定値时，探测器的报警确认灯不应点亮；",{"key":24,"text":529,"correct":26},"探测器监测区域单位时间故障电孤的数量达到报警设定值时，探测器的报警确认灯应在40s内点亮并保抟；",{"key":28,"text":465,"correct":22},{"key":31,"text":467,"correct":22},{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":24,"analysis":33},965215,"（ ）属于遇水放出易燃气体的物质。",[536,538,540,542],{"key":20,"text":537,"correct":22},"黄磷",{"key":24,"text":539,"correct":26},"金属钠",{"key":28,"text":541,"correct":22},"三氯化钛",{"key":31,"text":543,"correct":22},"氯酸铵",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":24,"analysis":33},965216,"按储存物品的火灾危险性分类，以下固体中（ ）属于乙类危险物品。",[548,549,551,553],{"key":20,"text":537,"correct":22},{"key":24,"text":550,"correct":26},"硫磺",{"key":28,"text":552,"correct":22},"面粉",{"key":31,"text":554,"correct":22},"纸张",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":24,"analysis":33},965217,"下列（ ）是不具有腐蚀毒害性的气体。",[559,561,563,565],{"key":20,"text":560,"correct":22},"氢气",{"key":24,"text":562,"correct":26},"氧气",{"key":28,"text":564,"correct":22},"氨气",{"key":31,"text":566,"correct":22},"硫化氢",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":20,"analysis":33},965218,"对于Ⅰ级易燃气体，其爆炸下限小于（ ）%。",[571,572,574,576],{"key":20,"text":85,"correct":26},{"key":24,"text":573,"correct":22},"12",{"key":28,"text":575,"correct":22},"13",{"key":31,"text":87,"correct":22},{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":24,"analysis":33},965219,"有些自燃物品起火时不能用水或泡沫扑救。是因为它具有的（ ）危险特性。",[581,583,585,587],{"key":20,"text":582,"correct":22},"遇空气自燃性",{"key":24,"text":584,"correct":26},"遇湿易燃易爆性",{"key":28,"text":586,"correct":22},"积热自燃性",{"key":31,"text":588,"correct":22},"以上都不对",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":31,"analysis":33},965220,"（ ）是生产和储存火灾危险性为甲类的液体。",[593,595,597,599],{"key":20,"text":594,"correct":22},"柴油",{"key":24,"text":596,"correct":22},"润滑油",{"key":28,"text":598,"correct":22},"煤油",{"key":31,"text":600,"correct":26},"汽油",[602,605,608,611,614,617],{"id":15,"name":603,"category":7,"favorite":604},"领导干部任职前廉政法规知识测试题",92,{"id":606,"name":607,"category":7,"favorite":15},595,"建筑结构与设备",{"id":609,"name":610,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":612,"name":613,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":615,"name":616,"category":7,"favorite":8},534,"BIM工程师",{"id":618,"name":616,"category":7,"favorite":8},535]