[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-19":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":600},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,19,50,2716,[13,34,42,54,66,78,90,102,114,126,138,150,162,174,186,196,208,220,232,244,256,268,280,292,304,316,327,339,351,363,375,387,399,411,423,434,446,458,470,482,494,506,518,530,542,554,562,572,584,592],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},965120,1,"单选题","室内净空高度小于6米的多层厂房的消火栓栓口动压，不应小于（ ）MPa。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","0.07",false,{"key":24,"text":25,"correct":22},"B","0.15",{"key":27,"text":28,"correct":29},"C","0.25",true,{"key":31,"text":32,"correct":22},"D","0.35","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},965121,"高层民用建筑的消火栓栓口动压，不应小于（ ）MPa。",[38,39,40,41],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":22},{"key":27,"text":28,"correct":22},{"key":31,"text":32,"correct":29},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":24,"analysis":33},965122,"室内消火栓系统消火栓栓口动压力不应大于（ ）MPa，但当大于（ ）MPa时应设置减压装置。",[46,48,50,52],{"key":20,"text":47,"correct":22},"0.5，0.5",{"key":24,"text":49,"correct":29},"0.5，0.7",{"key":27,"text":51,"correct":22},"0.7，0.5",{"key":31,"text":53,"correct":22},"0.7，0.7",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":27,"analysis":33},965123,"消防水泵的（ ）是指满足所服务的各种水灭火系统最不利点处水灭火设施的压力要求。",[58,60,62,64],{"key":20,"text":59,"correct":22},"秒流量",{"key":24,"text":61,"correct":22},"小时流量",{"key":27,"text":63,"correct":29},"场程",{"key":31,"text":65,"correct":22},"转速",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":20,"analysis":33},965124,"在泵房内，（ ）自动联动控制喷淋泵的启动，",[70,72,74,76],{"key":20,"text":71,"correct":29},"压力开关",{"key":24,"text":73,"correct":22},"水流指示器",{"key":27,"text":75,"correct":22},"信号阀",{"key":31,"text":77,"correct":22},"消火栓按钮",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":24,"analysis":33},965125,"功率放大器外接的喇叭间歇发声，声音很小。排查方法为检查功放（ ）输出外接的喇叭功率总数是否超标或内部是否短路。",[82,84,86,88],{"key":20,"text":83,"correct":22},"100V",{"key":24,"text":85,"correct":29},"120V",{"key":27,"text":87,"correct":22},"150V",{"key":31,"text":89,"correct":22},"220V",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":27,"analysis":33},965126,"功率放大器开机备电故障灯壳，检查备电电池组电压不能低于（ ）。",[94,96,98,100],{"key":20,"text":95,"correct":22},"15V",{"key":24,"text":97,"correct":22},"18V",{"key":27,"text":99,"correct":29},"20V",{"key":31,"text":101,"correct":22},"24V",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":27,"analysis":33},965127,"消防电梯的载重量不应小于（ ）kg。",[106,108,110,112],{"key":20,"text":107,"correct":22},"500",{"key":24,"text":109,"correct":22},"700",{"key":27,"text":111,"correct":29},"800",{"key":31,"text":113,"correct":22},"1000",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":24,"analysis":33},965128,"当备用电池组输出电压降到一定数值时，控制器发出电池欠压报警，当低于（ ）V时，控制器自动关机，以防电池过放而损坏。",[118,120,122,124],{"key":20,"text":119,"correct":22},"15",{"key":24,"text":121,"correct":29},"20",{"key":27,"text":123,"correct":22},"24",{"key":31,"text":125,"correct":22},"36",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":31,"analysis":33},965129,"对于压力式比例混合装置、平衡式比例混合装置、机械泵入式比例混合装置的安装质量，以下哪项不属于检查范围？（ ）",[130,132,134,136],{"key":20,"text":131,"correct":22},"检查比例混合装置的外观",{"key":24,"text":133,"correct":22},"检查泡沬液储罐的检修空间是否满足要求",{"key":27,"text":135,"correct":22},"检查比例混合装置的安装方向",{"key":31,"text":137,"correct":29},"检查发泡倍数",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":31,"analysis":33},965130,"中倍数、高倍数泡沫产生器的安装质量检查不包括（ ）。",[142,144,146,148],{"key":20,"text":143,"correct":22},"检查泡沫产生器的外观",{"key":24,"text":145,"correct":22},"检查泡沫产生器的型号",{"key":27,"text":147,"correct":22},"检查泡沫产生器的进气情况",{"key":31,"text":149,"correct":29},"检查泡沫产生器的密封玻璃",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":20,"analysis":33},965131,"对于泡沫产生装置的安装质量检查符合要求的有（ ）。",[154,156,158,160],{"key":20,"text":155,"correct":29},"低倍数泡沫产生器安装间距偏差不宜大于100mm",{"key":24,"text":157,"correct":22},"中倍数、高倍数泡沫产生器在进气端0.5m范围内不应有遮挡物",{"key":27,"text":159,"correct":22},"中倍数、高倍数泡沫产生器在发泡网出口3.0m范围内，不应有影响泡沫喷放的障碍物",{"key":31,"text":161,"correct":22},"中倍数、高倍数泡沫产生器其位置应位于泡沫淹没深度以下",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":27,"analysis":33},965132,"气体灭火系统手动启动\u002F停止按钮、手动\u002F自动转换装置的安装不符合要求的是：（ ）",[166,168,170,172],{"key":20,"text":167,"correct":22},"手动启动\u002F停止按钮、手动\u002F自动转换装置应安装在明显和便于操作的部位",{"key":24,"text":169,"correct":22},"当安装在墙上时，其底边距地（楼）面高度宜为1.3?1.5m",{"key":27,"text":171,"correct":29},"放气指示灯一般安装在防护区疏散门外左右便于观察的地方",{"key":31,"text":173,"correct":22},"放气指示灯应安装牢固；连接导线应留有不小于150mm的余量，且在其端部应有明显标志",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":20,"analysis":33},965133,"拉索式机械驱动装置的安装不符合规定的是：（ ）。",[178,180,182,184],{"key":20,"text":179,"correct":29},"拉索应采用经内外防腐处理的钢管防护",{"key":24,"text":181,"correct":22},"拉索转弯处应采用专用导向滑轮",{"key":27,"text":183,"correct":22},"拉索末端拉手应设在专用的保护盒内",{"key":31,"text":185,"correct":22},"拉索套管和保护盒应固定牢靠",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":27,"analysis":33},965134,"安装重力式机械驱动装置时，应保证重物在下落行程中无阻挡，其下落行程应保证驱动所需距离，且不得小于（ ）mm。",[190,191,192,194],{"key":20,"text":119,"correct":22},{"key":24,"text":121,"correct":22},{"key":27,"text":193,"correct":29},"25",{"key":31,"text":195,"correct":22},"30",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":31,"analysis":33},965135,"气体灭火系统启动装置的安装不符合要求的有：（ ）。",[200,202,204,206],{"key":20,"text":201,"correct":22},"安装重力式机械驱动装置时，应保证重物在下落行程中无阻挡，其下落行程应保证驱动所需距离，且不得小于25mm",{"key":24,"text":203,"correct":22},"电磁驱动装置驱动器的电气连接线应沿固定灭火剂储存容器的支、框架或墙面固定",{"key":27,"text":205,"correct":22},"拉索式机械驱动装置的拉索除必要外露部分外，应采用经内外防腐处理的钢管防护",{"key":31,"text":207,"correct":29},"拉索式机械驱动装置的拉索末端拉手应设在明显和便于操作的部位",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":31,"analysis":33},965136,"气动驱动装置的安装不符合规定的是：（ ）",[212,214,216,218],{"key":20,"text":213,"correct":22},"驱动气瓶的支、框架或箱体应固定牢靠，并做防腐处理",{"key":24,"text":215,"correct":22},"驱动气瓶上应有标明驱动介质名称、对应防护区或保护对象名称或编号的永久性标志",{"key":27,"text":217,"correct":22},"气动驱动装置的管道安装后应做气压严密性试验，并合格。",{"key":31,"text":219,"correct":29},"气动驱动装置的管道安装后应做水压严密性试验，并合格。",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":27,"analysis":33},965137,"气动驱动装置的管道安装不符合管道布置设计要求的是：（ ）",[224,226,228,230],{"key":20,"text":225,"correct":22},"竖直管道应在其始端和终端设防晃支架或采用管卡固定",{"key":24,"text":227,"correct":22},"水平管道应采用管卡固定",{"key":27,"text":229,"correct":29},"管卡的间距不宜大于0.5m",{"key":31,"text":231,"correct":22},"转弯处应增设1个管卡",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":24,"analysis":33},965138,"关于气体灭火系统启动装置气压强度试验和气密性试验的说法不符合要求的是（ ）。",[236,238,240,242],{"key":20,"text":237,"correct":22},"气压强度试验时，应逐步缓慢增加压力，当压力升至试验压力的50%时，如未发现异状或泄漏，继续按试验压力的10%逐级升压，每级稳压3min，直至试验压力。保压检查管道各处无变形、无泄漏为合格。",{"key":24,"text":239,"correct":29},"进行气密性试验时，应以不大于0.5MPa\u002Fs的升压速率缓慢升压至试验压力，关断试验气源5min内压力下降不超过试验压力的10%为合格。",{"key":27,"text":241,"correct":22},"气压强度试验和气密性试验必须来取有效的安全措施",{"key":31,"text":243,"correct":22},"气动管道试验时应采取防止误喷射的措施",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":24,"analysis":33},965139,"灭火剂储存装置的安装要求不包括：（ ）",[248,250,252,254],{"key":20,"text":249,"correct":22},"储存装置的安装位置应符合设计文件的要求",{"key":24,"text":251,"correct":29},"灭火剂储存装置安装后，泄压装置的泄压方向应朝向操作面",{"key":27,"text":253,"correct":22},"低压二氧化碳灭火系统的安全阀应通过专用的泄压管接到室外",{"key":31,"text":255,"correct":22},"储存装置上压力计、液位计、称重显示装置的安装位置应便于人员观察和操作",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":24,"analysis":33},965140,"下面不符合灭火剂储存装置的安装要求的有：（ ）",[260,262,264,266],{"key":20,"text":261,"correct":22},"储存容器的支、框架应固定牢靠，并应做防腐处理。",{"key":24,"text":263,"correct":29},"储存容器宜涂黑色油漆，正面应标明设计规定的灭火剂名称和储存容器的编号。",{"key":27,"text":265,"correct":22},"安装集流管前应检查内腔，确保清洁。",{"key":31,"text":267,"correct":22},"集流管上的泄压装置的泄压方向不应朝向操作面。",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":31,"analysis":33},965141,"灭火剂输送管道的气密性试验不符合规定的是（ ）。",[272,274,276,278],{"key":20,"text":273,"correct":22},"对灭火剂输送管道，应取水压强度试验压力的2\u002F3",{"key":24,"text":275,"correct":22},"对气动管道，应取驱动气体储存压力",{"key":27,"text":277,"correct":22},"进行气密牲试验时，应以不大于0.5MPa\u002Fs的升压速率缓慢升压至试验压力，关断试验气源3min内压力降不超过试验压力的10%为合格。",{"key":31,"text":279,"correct":29},"试验时，应逐步缓慢增加压力，当压力升至试验压力的50%时，如未发现异状或泄露，继续按试验压力的10%逐级升压，每级升压3min，直至试验压力。保压检查管道各处无变形、无泄漏为合格。",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":27,"analysis":33},965142,"对于灭火剂输送管道油漆涂覆不符合规定的有（ ）。",[284,286,288,290],{"key":20,"text":285,"correct":22},"灭火剂输送管道的外表面宜徐红色油漆",{"key":24,"text":287,"correct":22},"在吊顶内、活动地板下等隐蔽场所内的管道，可涂红色油漆色环",{"key":27,"text":289,"correct":29},"色环宽度不应小于500mm",{"key":31,"text":291,"correct":22},"每个防护区或保护对象的色环宽度应一致，间距应均匀",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":31,"analysis":33},965143,"气体灭火系统喷嘴的安装不符合要求的是（ ）。",[296,298,300,302],{"key":20,"text":297,"correct":22},"安装喷嘴吋，应按设计要求逐个核对其型号、规格及喷孔方向。",{"key":24,"text":299,"correct":22},"安装在吊顶下的不带装饰罩的喷嘴，其连接管管端螺纹不应露出吊顶",{"key":27,"text":301,"correct":22},"安装在吊顶下的带装饰罩的喷嘴，其装饰罩应紧贴吊顶",{"key":31,"text":303,"correct":29},"安装在吊顶下的带装饰罩的喷嘴，其连接管管端螺纹不应露出吊顶",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":20,"analysis":33},965144,"消防炮的安装与施工不符合要求的有：（ ）",[308,310,312,314],{"key":20,"text":309,"correct":29},"消防炮安装应符合设计要求，且应在供水管线系统试压、冲洗合格前进行。",{"key":24,"text":311,"correct":22},"消防炮安装前应确定基座上供灭火剂的立管固定可靠。",{"key":27,"text":313,"correct":22},"消防炮回转范围应与防护区相对应",{"key":31,"text":315,"correct":22},"消防炮安装后，应检查确认在其设计规定的水平和俯仰回转范围内不与周围的构件碰撞",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":27,"analysis":33},965145,"下列消防炮的安装与施工不符合要求的有：（ ）",[320,322,324,326],{"key":20,"text":321,"correct":22},"与消防炮连接的电、液、气管线应安装牢固，且不得干涉回转机构。",{"key":24,"text":323,"correct":22},"消防炮安装应符合设计要求，且应在供水管线系统试压、冲洗合格后进行。",{"key":27,"text":325,"correct":29},"消防炮回转范围应与回转机构相对应",{"key":31,"text":315,"correct":22},{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":27,"analysis":33},965146,"对于泡沬比例混合装置与泡沫液罐的安装与施工不符合要求的是：（ ）",[331,333,335,337],{"key":20,"text":332,"correct":22},"泡沬液罐的安装位置和高度应符合设计要求。",{"key":24,"text":334,"correct":22},"常压泡沬液罐的现场制作、安装和防腐应符合设计要求。",{"key":27,"text":336,"correct":29},"压力式泡沫液罐安装时，支架应与基础牢固固定，且不应拆卸和损坏配管、附件；罐的安全阀出口应朝向操作面。",{"key":31,"text":338,"correct":22},"设在室外的泡沬液罐的安装应符合设计要求，并应根据环境条件采取防晒、防冻、防腐等措施。",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":33},965147,"固定消防炮灭火系统泡抹比例混合装置与泡沫液罐的安装与施工不符合要求的是：（ ）",[343,345,347,349],{"key":20,"text":344,"correct":22},"压力式比例混合装置应整体安装，与管道连接处的安装应严密。",{"key":24,"text":346,"correct":29},"泡沫比例混合装置的标注方向应与液流方向相反。",{"key":27,"text":348,"correct":22},"平衡式泡沫比例混合装置的安装应符合设计和产品要求。",{"key":31,"text":350,"correct":22},"常压泡沫液罐的现场制作、安装和防腐应符合设计要求。",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":20,"analysis":33},965148,"以下干粉罐与氮气瓶组的安装与施工不符合要求的是：（ ）",[355,357,359,361],{"key":20,"text":356,"correct":29},"安装在室外时，干粉罐和氮气瓶组应根据环境条件设置防晒、防雨、防腐等防护设施。",{"key":24,"text":358,"correct":22},"干粉罐和氮气瓶组的安装位置和高度应符合设计要求。",{"key":27,"text":360,"correct":22},"干粉罐和氮气瓶组中需现场制作的连接管道应采取防腐处理措施。",{"key":31,"text":362,"correct":22},"干粉罐和氮气瓶组的支架应固定牢固，且应采取防腐处理措施。",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":31,"analysis":33},965149,"以下消防炮塔的安装与施工不符合要求的是：（ ）",[367,369,371,373],{"key":20,"text":368,"correct":22},"安装消防炮塔的地面基座应稳固，钢筋混凝土基座施工后应有足够的养护时间",{"key":24,"text":370,"correct":22},"消防炮塔与地面基座的连接应固定可靠",{"key":27,"text":372,"correct":22},"消防炮塔安装后应采取相应的防腐措施",{"key":31,"text":374,"correct":29},"消防炮塔不需做防雷接地",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":20,"analysis":33},965150,"不符合固定消防炮灭火系统手动启动功能验收要求的是：（ ）",[379,381,383,385],{"key":20,"text":380,"correct":29},"使系统电源处于接通状态，各控制装置的操作按钮处于自动状态",{"key":24,"text":382,"correct":22},"逐个按下各消防泵组的手动操作启、停按钮，观察消防泵组的动作及反馈信号情况是否正常",{"key":27,"text":384,"correct":22},"逐个按下各电控阀门的手动操作启、停按钮，观察阀门的启、闭动作及反馈信号情况是否正常",{"key":31,"text":386,"correct":22},"用手动按钮或手持式无线遥控发射装置逐个操控相对应的消防炮做俯仰和水平回转动作，观察各消防炮的动作及反馈信号是否正常",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":31,"analysis":33},965151,"下列哪项不符合固定消防炮灭火系统消防泵组功能验收要求：（ ）",[391,393,395,397],{"key":20,"text":392,"correct":22},"按系统设计要求，启动消防泵组，观察该消防泵组及相关设备动作是否正常，若正常，消防泵组在设计负荷下，连续运转不应小于2h",{"key":24,"text":394,"correct":22},"接通控制装置电源，并使消防泵组控制装置处于自动状态，人工启动一台消防泵组，观察该消防泵组及相关设备动作是否正常",{"key":27,"text":396,"correct":22},"模拟消防泵组故障，使之停泵，此时，备用消防泵组应能自动投入运行",{"key":31,"text":398,"correct":29},"备用消防泵组在设计负荷下，连续运转不应小于2h",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":20,"analysis":33},965152,"下面不符合固定消防炮灭火系统联动控制功能验收要求的是：（ ）",[403,405,407,409],{"key":20,"text":404,"correct":29},"对设计的联动控制单元进行抽查",{"key":24,"text":406,"correct":22},"接通系统电源，使待检联动控制单元的被控设备均处于自动状态，按下对应的联动启动按钮，该单元应能按设计要求自动启动消防泵组",{"key":27,"text":408,"correct":22},"打开阀门等相关设备，直至消防炮喷射灭火剂（或水幕保护系统出水）",{"key":31,"text":410,"correct":22},"该单元设备的动作与信号反馈应符合设计要求",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":27,"analysis":33},965153,"以下不符合固定消防炮灭火系统喷射功能验收试验条件要求的有（ ）：",[415,417,419,421],{"key":20,"text":416,"correct":22},"水炮和水幕保系统采用消防水进行喷射",{"key":24,"text":418,"correct":22},"泡抹炮系统的比例混合装置及泡沫液的规格应符合设计要求",{"key":27,"text":420,"correct":29},"消防泵组供水达到设计供水压力",{"key":31,"text":422,"correct":22},"干粉炮系统的干粉型号、规格、储量和氮气瓶组的规格、压力应符合系统设计要求",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":31,"analysis":33},965154,"气体灭火系统气压强度试验不符合规定的是：（ ）",[427,429,431,432],{"key":20,"text":428,"correct":22},"试验前，必须用加压介质进行预试验，预试验压力宜为0.2MPa",{"key":24,"text":430,"correct":22},"试验时，应逐步缓慢增加压力，当压力升至试验压力的50%时，如未发现异状或泄漏，继续按试验压力的10%逐级升压，每级稳压3min，直至试验压力。保压检查管道各处无变形、无泄漏为合格",{"key":27,"text":275,"correct":22},{"key":31,"text":433,"correct":29},"试验时，应以不大于0.5MPa\u002Fs的升压速率缓慢升压至试验压力，关断试验气源3min内压力下降不超过试验压力的10%为合格",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":20,"analysis":33},965155,"液态水具有压缩性和膨胀性，通常状况下。二者的特性为（ ）。",[438,440,442,444],{"key":20,"text":439,"correct":29},"压缩性小，膨胀性小",{"key":24,"text":441,"correct":22},"压缩性小，膨胀性大",{"key":27,"text":443,"correct":22},"压缩性大，膨胀性小",{"key":31,"text":445,"correct":22},"压缩性大，膨胀性大",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":31,"analysis":33},965156,"消防水泵的扬程是指满足所服务的水灭火系统最不利点处（ ）要求。",[450,452,454,456],{"key":20,"text":451,"correct":22},"流量",{"key":24,"text":453,"correct":22},"流速",{"key":27,"text":455,"correct":22},"静水压力",{"key":31,"text":457,"correct":29},"工作压力",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":24,"analysis":33},965157,"柜门应常闭，柜体不得有变形，油漆不得有脱落，门应能启闭自如，基础应高出地面（ ）。每周至少用拧干的湿抹布擦净柜体。",[462,464,466,468],{"key":20,"text":463,"correct":22},"100mm",{"key":24,"text":465,"correct":29},"150mm",{"key":27,"text":467,"correct":22},"200mm",{"key":31,"text":469,"correct":22},"250mm",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":31,"analysis":33},965158,"对于稳压泵的维护保养，手动启动稳圧泵（ ）min，观察泵体及电动机的发热情况；当设置有气压水罐时，稳压泵启泵次数不大于（ ）次\u002Fh。",[474,476,478,480],{"key":20,"text":475,"correct":22},"5，10",{"key":24,"text":477,"correct":22},"5，15",{"key":27,"text":479,"correct":22},"10，10",{"key":31,"text":481,"correct":29},"10，15",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":27,"analysis":33},965159,"（ ）应对柴油机消防水泵的启动电池的电量进行检测，（ ）应检查储油箱的储油量，（ ）应手动启动柴油机消防水泵运行一次。",[486,488,490,492],{"key":20,"text":487,"correct":22},"每日，每日，每日",{"key":24,"text":489,"correct":22},"每日，每周，每周",{"key":27,"text":491,"correct":29},"每日，每周，每月",{"key":31,"text":493,"correct":22},"每日，每月，每月",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":31,"analysis":33},965160,"消防水泵维修保养时。电动泵运行时间不少于（ ）min，柴油泵启动不少于（ ）min，并观察水泵出水压力是否符合要求。",[498,500,502,504],{"key":20,"text":499,"correct":22},"8min；25min",{"key":24,"text":501,"correct":22},"8min；30min",{"key":27,"text":503,"correct":22},"10min；25min",{"key":31,"text":505,"correct":29},"10min；30min",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":27,"analysis":33},965161,"轴流深井泵安装在消防池等消防水源上时，其第一个水泵叶轮底部应低于消防水池的最低有效水位线，且淹没深度应根据水力条件经计算确定，并应满足消防水池等消防水源有效储水量或有效水位能全部被利用的要求；当水泵额定流量大于（ ）时，应根据水泵性能确定淹没深度，并应满足水泵气蚀余量的要求。",[510,512,514,516],{"key":20,"text":511,"correct":22},"100L\u002Fs",{"key":24,"text":513,"correct":22},"110L\u002Fs",{"key":27,"text":515,"correct":29},"125L\u002Fs",{"key":31,"text":517,"correct":22},"140L\u002Fs",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":24,"analysis":33},965162,"水泵机组基础的顶面标高，无隔振安装时应高出泵房地面不小于（ ）m；有隔振安装时可高出泵房地面不小于（ ）m。",[522,524,526,528],{"key":20,"text":523,"correct":22},"0.05，0.05",{"key":24,"text":525,"correct":29},"0.10，0.05",{"key":27,"text":527,"correct":22},"0.05，0.10",{"key":31,"text":529,"correct":22},"0.10，0.10",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":20,"analysis":33},965163,"稳压泵维护保养要求错误的是（ ）。",[534,536,538,540],{"key":20,"text":535,"correct":29},"稳压设备房内应有良好的通风散热条件；室温不应低于4℃",{"key":24,"text":537,"correct":22},"气压罐外表面油漆完好，无机械性损伤，附件齐全完好",{"key":27,"text":539,"correct":22},"稳压泵外表面完好，无机械性损伤。水泵动力部分与水泵连接牢固",{"key":31,"text":541,"correct":22},"设在室外的稳压泵防水、防雨措施完好",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":27,"analysis":33},965164,"每（ ）应对气压水罐的压力和有效容积等进行一次检测。",[546,548,550,552],{"key":20,"text":547,"correct":22},"日",{"key":24,"text":549,"correct":22},"周",{"key":27,"text":551,"correct":29},"月",{"key":31,"text":553,"correct":22},"季",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":27,"analysis":33},965165,"根据相关规定。单位每（ ）应手动启动稳压泵运转一次，并应检查供电电源的情况。",[558,559,560,561],{"key":20,"text":547,"correct":22},{"key":24,"text":549,"correct":22},{"key":27,"text":551,"correct":29},{"key":31,"text":553,"correct":22},{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":31,"analysis":33},965166,"根据规定，消防设施维保人员应每（ ）进行消防系统联动测试。",[566,567,568,570],{"key":20,"text":551,"correct":22},{"key":24,"text":553,"correct":22},{"key":27,"text":569,"correct":22},"半年",{"key":31,"text":571,"correct":29},"年",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":20,"analysis":33},965167,"每（ ）检查电器控制部分；每（ ）检查泵组的密封情况。",[576,578,580,582],{"key":20,"text":577,"correct":29},"日，日",{"key":24,"text":579,"correct":22},"周，周",{"key":27,"text":581,"correct":22},"月，月",{"key":31,"text":583,"correct":22},"周，月",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":27,"analysis":33},965168,"每（ ）测试压力开关直接启泵功能，消火栓按钮联动启泵功能。",[588,589,590,591],{"key":20,"text":549,"correct":22},{"key":24,"text":551,"correct":22},{"key":27,"text":553,"correct":29},{"key":31,"text":569,"correct":22},{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":24,"analysis":33},965169,"每（ ）检查泵房、散热通风设施、百叶窗，保证泵房有良好的散热条件。",[596,597,598,599],{"key":20,"text":547,"correct":22},{"key":24,"text":549,"correct":29},{"key":27,"text":551,"correct":22},{"key":31,"text":553,"correct":22},[601,604,607,610,613,616],{"id":15,"name":602,"category":7,"favorite":603},"领导干部任职前廉政法规知识测试题",92,{"id":605,"name":606,"category":7,"favorite":15},595,"建筑结构与设备",{"id":608,"name":609,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":611,"name":612,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":614,"name":615,"category":7,"favorite":8},534,"BIM工程师",{"id":617,"name":615,"category":7,"favorite":8},535]