[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-18":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":576},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,18,50,2716,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,261,270,282,293,305,317,329,341,353,364,376,384,392,402,414,426,434,442,450,458,466,474,482,494,506,518,530,542,553,565],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},965069,1,"单选题","控制器与集中电源或应急照明配电箱间通信线路断路、短路或接线不良，消防应急照明和疏散指示系统会报什么故障？（ ）",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","控制器显示集中电源或应急照明配电箱配接的多个“灯具故障”",false,{"key":24,"text":25,"correct":22},"B","应急照明控制器不能自动控制系统设备应急启动、标志灯指示状态改変",{"key":27,"text":28,"correct":29},"C","控制器显示“集中电源或应急照明配电箱故障”",true,{"key":31,"text":32,"correct":22},"D","控制器显示某一“灯具故障”","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},965070,"当采样管道采用毛细管布置方式时，毛细管长度不宜超过（ ）m。",[38,40,42,44],{"key":20,"text":39,"correct":22},"1",{"key":24,"text":41,"correct":22},"2",{"key":27,"text":43,"correct":29},"4",{"key":31,"text":45,"correct":22},"6",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},965071,"采样孔需要现场加工时，应采用（ ）打孔工具。",[50,52,54,56],{"key":20,"text":51,"correct":22},"专业",{"key":24,"text":53,"correct":29},"专用",{"key":27,"text":55,"correct":22},"通用",{"key":31,"text":57,"correct":22},"专门",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},965072,"吸气式感烟火灾探测器采样管路的安装要求说法正确的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"采样管宜牢固安装在过梁、支架等建筑结构上；",{"key":24,"text":65,"correct":22},"采样孔不应正对气流方向；",{"key":27,"text":67,"correct":22},"当采样管道采用垂直布置方式时，毛细管长度不宜超过4m；",{"key":31,"text":69,"correct":29},"采样管和采样孔应设置明显的火灾探测器标识；",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},965073,"下面哪项不是火焰探测器和图像型火灾探测器安装位置的要求？（ ）",[74,76,78,80],{"key":20,"text":75,"correct":22},"安装位置应保证其视场角覆盖探测区域",{"key":24,"text":77,"correct":22},"应避免光源直接照射在探测器的探测窗口上",{"key":27,"text":79,"correct":22},"探测器的探测视角内不应存在遮挡物",{"key":31,"text":81,"correct":29},"在室外或交通隧道内安装时，应采取防尘、防水措施",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},965074,"关于吸气式感烟火灾探测器的说法不正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"吸气式感烟火灾探测器的操作可靠性取决于烟雾传感器的功能可靠性和系统的持续空气供给",{"key":24,"text":89,"correct":22},"若风机发生故障、探测器吸气管路发生破漏或堵塞等现象，导致探测器吸气流量大于正常吸气流量的150%或小于正常吸气流量的50%时，探测器应在100s内发出故障信号",{"key":27,"text":91,"correct":29},"若探测器在任一采样孔获取的火灾烟霎参数符合报警条件时，探测器应在100s内发出火灾报警信号",{"key":31,"text":93,"correct":22},"吸气式感烟火灾探测器可以监测到防护区域内微小的烟雾浓度变化，实现早期火灾探测报警功能。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},965075,"若吸气式感烟火灾探测器在任一采样孔获取的乂灾烟雾参数符合报警条件时，探测器应在（ ）s内发出火灾报警信号。",[98,100,102,104],{"key":20,"text":99,"correct":22},"80",{"key":24,"text":101,"correct":22},"100",{"key":27,"text":103,"correct":29},"120",{"key":31,"text":105,"correct":22},"140",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":27,"analysis":33},965076,"火焰探测器是通过（ ），检测火焰的特定波长及闪烁频率，将火焰辐射能量转化为电流或电压信号而达到探测火灾的目的。",[110,112,114,116],{"key":20,"text":111,"correct":22},"采集空气样本",{"key":24,"text":113,"correct":22},"采集视频图像",{"key":27,"text":115,"correct":29},"感应火焰辐射的电磁波",{"key":31,"text":117,"correct":22},"采集烟雾样本",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},965077,"为了避免环境可见光引起的误报，火焰探测器通常选择探测（ ）的红外光或紫外光。",[122,124,126,128],{"key":20,"text":123,"correct":22},"可见光波长",{"key":24,"text":125,"correct":29},"非可见光波长",{"key":27,"text":127,"correct":22},"特定波长",{"key":31,"text":129,"correct":22},"设计波长",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},965078,"火焰的闪烁频率为（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"0.5Hz-10Hz",{"key":24,"text":137,"correct":29},"0.5Hz-20Hz",{"key":27,"text":139,"correct":22},"1Hz-10Hz",{"key":31,"text":141,"correct":22},"1Hz-20Hz",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":27,"analysis":33},965079,"下面火焰探测器的说法不正确的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"火焰探测器是通过感应火焰辐射的电磁波，检测火焰的特定波长及闪烁频率，将火焰辐射能量转化为电流或电压信号而达到探测火灾的目的。",{"key":24,"text":149,"correct":22},"火焰的闪烁频率为0.5Hz-20Hz",{"key":27,"text":151,"correct":29},"热物体、电灯等辐射出的紫外线、红外线有闪烁特征",{"key":31,"text":153,"correct":22},"为了避免环境可见光引起的误报，火焰探测器通常选择探测非可见光波长的红外光或紫外光",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},965080,"以下哪项可测试火焰探测器的（ ）故障报警信号？",[158,160,162,164],{"key":20,"text":159,"correct":29},"使用纸张等物品完全遮挡火焰探测器探测窗口",{"key":24,"text":161,"correct":22},"将打火机产生的火焰置于探测器正前方lm左右",{"key":27,"text":163,"correct":22},"将蜡烛产生的火焰置于探测器上方lm左右",{"key":31,"text":165,"correct":22},"将酒精灯等产生的火焰置于探测器正前方3m左右",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":31,"analysis":33},965081,"下面哪项不是吸气式感烟火灾探测器的检测内容：（ ）",[170,172,174,176],{"key":20,"text":171,"correct":22},"探测器灵敏度",{"key":24,"text":173,"correct":22},"采样管安装",{"key":27,"text":175,"correct":22},"采样孔设置",{"key":31,"text":177,"correct":29},"安装过程",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":27,"analysis":33},965082,"天棚高度大于（ ）m的场所，探测器应设为最高灵敏度。",[182,184,186,188],{"key":20,"text":183,"correct":22},"14",{"key":24,"text":185,"correct":22},"15",{"key":27,"text":187,"correct":29},"16",{"key":31,"text":189,"correct":22},"17",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},965083,"天棚高度大于16m的场所，探测器应设为最高灵敏度，并保证至少有（ ）采样孔低于16m；非高灵敏度的吸气式感烟火灾探测器不宜安装在天棚高度大于16m的场所。",[194,196,198,200],{"key":20,"text":195,"correct":22},"—个",{"key":24,"text":197,"correct":29},"两个",{"key":27,"text":199,"correct":22},"三个",{"key":31,"text":201,"correct":22},"五个",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":27,"analysis":33},965084,"对吸气式感烟火灾探测器进行检测时，采样孔设置不符合要求的是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"在大空间场所安装时，每个采样孔的保护面积、保护半径应符合点型感烟火灾探测器的保护面积、保护半径的要求",{"key":24,"text":209,"correct":22},"采样孔的直径应根据采样管的长度及敷设方式、采样孔的数量等因素确定，并应符合设计文件和产品使用说明书的要求",{"key":27,"text":211,"correct":29},"当采样管道布置形式为垂直采样时，每3℃温差间隔或2m间隔（取最小者）应设置一个采样孔",{"key":31,"text":213,"correct":22},"采样孔需要现场加工时，应采用专用打孔工具",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":27,"analysis":33},965085,"若探测器在（ ）采样孔获取的火灾烟雾参数符合报警条件时，探测器应在120s内发出火灾报警信号。",[218,220,222,224],{"key":20,"text":219,"correct":22},"独立",{"key":24,"text":221,"correct":22},"不同",{"key":27,"text":223,"correct":29},"任一",{"key":31,"text":225,"correct":22},"同一区域",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":31,"analysis":33},965086,"吸气式感烟火灾探测器可以监测到（ ）内微小的烟雾浓度变化，实现早期火灾探测报警功能。",[230,232,234,236],{"key":20,"text":231,"correct":22},"防火分区",{"key":24,"text":233,"correct":22},"防烟分区",{"key":27,"text":235,"correct":22},"报警区域",{"key":31,"text":237,"correct":29},"防护区域",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":31,"analysis":33},965087,"哪些物质不能用来向采样孔施加烟气以检测吸气式感烟火灾探测器的火灾报警功能？（ ）",[242,244,246,248],{"key":20,"text":243,"correct":22},"加烟器",{"key":24,"text":245,"correct":22},"香烟",{"key":27,"text":247,"correct":22},"棉绳",{"key":31,"text":249,"correct":29},"酒精",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":31,"analysis":33},965088,"图像型火灾探测器从发生火灾到发出火灾报警信号的响应时间不应大于（ ）s。",[254,256,258,259],{"key":20,"text":255,"correct":22},"5",{"key":24,"text":257,"correct":22},"10",{"key":27,"text":185,"correct":22},{"key":31,"text":260,"correct":29},"20",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":27,"analysis":33},965089,"消防水泵的时间继电器设置错误或损坏。正确设置转换时间或更换时间继电器，对于一个30KW的时间继电器大约需要（ ）s。",[265,267,268,269],{"key":20,"text":266,"correct":22},"8",{"key":24,"text":257,"correct":22},{"key":27,"text":185,"correct":29},{"key":31,"text":260,"correct":22},{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":33},965090,"检查消防水泵电源自动切换功能，应符合以下规定：双路电源可手动及自动切换时，自动切换时间不应大于（ ）；当一路电源与内燃机动力切换时，切换时间不应大于（ ）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"2s；10s",{"key":24,"text":277,"correct":29},"2s；15s",{"key":27,"text":279,"correct":22},"3s；10s",{"key":31,"text":281,"correct":22},"3s；15s",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":24,"analysis":33},965091,"工频启动消防水泵时，当配用电机功率不大于132KW时，从接通电路到水泵达到额定转速的时间不宜大于（ ）s。",[286,287,289,291],{"key":20,"text":260,"correct":22},{"key":24,"text":288,"correct":29},"30",{"key":27,"text":290,"correct":22},"40",{"key":31,"text":292,"correct":22},"55",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":31,"analysis":33},965092,"消防水泵应保证在火灾发生后规定的时间内正常工作，从接到启泵信号到水泵正常启动时间不应大于（ ）；当控制柜内的控制线路发生故降，采用手动机械启泵时，应确保消防水泵在报警（ ）内正常工作",[297,299,301,303],{"key":20,"text":298,"correct":22},"1min；3min",{"key":24,"text":300,"correct":22},"1min；4min",{"key":27,"text":302,"correct":22},"2min；4min",{"key":31,"text":304,"correct":29},"2min；5min",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":27,"analysis":33},965093,"消防水泵控制柜设置在独立的控制室时，其防护等级不应低于（ ）；与消防水泵设置在同一空间时。其防护等级不应低于（ ）；控制柜的上下进出线口时。不应破坏控制柜的防护等级。",[309,311,313,315],{"key":20,"text":310,"correct":22},"IP20；IP35",{"key":24,"text":312,"correct":22},"IP30；IP45",{"key":27,"text":314,"correct":29},"IP30；IP55",{"key":31,"text":316,"correct":22},"IP40；IP55",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":27,"analysis":33},965094,"稳压泵的设计压力应保持系统最不利点处水灭火设施的在准工作状态时的压力大于该处的静水压，且增加值不应小于（ ）MPa。",[321,323,325,327],{"key":20,"text":322,"correct":22},"0.05",{"key":24,"text":324,"correct":22},"O.1O",{"key":27,"text":326,"correct":29},"0.15",{"key":31,"text":328,"correct":22},"0.3",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":27,"analysis":33},965095,"柴油机消防水泵应具备连续工作的性能，试验运行时间不应小于（ ）。",[333,335,337,339],{"key":20,"text":334,"correct":22},"6h",{"key":24,"text":336,"correct":22},"12h",{"key":27,"text":338,"correct":29},"24h",{"key":31,"text":340,"correct":22},"36h",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":20,"analysis":33},965096,"下列消防水泵的说法，正确的是（ ）。",[345,347,349,351],{"key":20,"text":346,"correct":29},"水泵驱动器宜采用电动机或柴油机直接传动；消防水泵不应采用双电动机或基于柴油机等组成的双动力驱动水泵。",{"key":24,"text":348,"correct":22},"当采用电动机驱动的消防水泵时。应选择电动机湿式安装的消防水泵。",{"key":27,"text":350,"correct":22},"宜采用潜水泵直接放置在水中进行吸水的方式。",{"key":31,"text":352,"correct":22},"电机干式安装维修时困难，有时要排空消防水池才能维修，造成消防给水的可靠性降低",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":27,"analysis":33},965097,"控制柜柜门应常闭，柜体不得有变形。油漆不得有脱落，门应能启闭自如，基础应高出地面（ ）mm。",[357,359,360,362],{"key":20,"text":358,"correct":22},"50",{"key":24,"text":101,"correct":22},{"key":27,"text":361,"correct":29},"150",{"key":31,"text":363,"correct":22},"200",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":24,"analysis":33},965098,"每（ ）检查消防控制柜电器控制部分，要求控制部分完好。",[368,370,372,374],{"key":20,"text":369,"correct":22},"日",{"key":24,"text":371,"correct":29},"周",{"key":27,"text":373,"correct":22},"月",{"key":31,"text":375,"correct":22},"季",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":27,"analysis":33},965099,"每（ ）检查水泵控制柜面板上面的指示，应清晰易辨。",[380,381,382,383],{"key":20,"text":369,"correct":22},{"key":24,"text":371,"correct":22},{"key":27,"text":373,"correct":29},{"key":31,"text":375,"correct":22},{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":20,"analysis":33},965100,"每（ ）应对稳压泵的停泵启泵压力和启泵次数等进行检查和记录运行情况。",[388,389,390,391],{"key":20,"text":369,"correct":29},{"key":24,"text":371,"correct":22},{"key":27,"text":373,"correct":22},{"key":31,"text":375,"correct":22},{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":24,"analysis":33},965101,"为保证泵房有良好的运行环境，消防水泵房应设计相应的采暖、通风设施，通风量宜按（ ）次\u002Fh。",[396,398,399,401],{"key":20,"text":397,"correct":22},"3",{"key":24,"text":45,"correct":29},{"key":27,"text":400,"correct":22},"12",{"key":31,"text":185,"correct":22},{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":27,"analysis":33},965103,"以下维护保养要求描述错误的是（ ）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"检查消防水泵，确保水泵各组成部分正常",{"key":24,"text":409,"correct":22},"各阀门均处于正常工作状态，确保进出水管能正常工作",{"key":27,"text":411,"correct":29},"检查供电情况，要求电源接通，电流正常",{"key":31,"text":413,"correct":22},"确保柴油引擎各组成部分能够正常工作",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":27,"analysis":33},965104,"为保证泵房有良好的运行环境，严寒、寒冷等冬季结冰地区采暖温度不应低于（ ）℃，但当无人值守时不应低于（ ）℃。",[418,420,422,424],{"key":20,"text":419,"correct":22},"21，4",{"key":24,"text":421,"correct":22},"11，4",{"key":27,"text":423,"correct":29},"10，5",{"key":31,"text":425,"correct":22},"5，0",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":27,"analysis":33},965105,"每（ ）应手动启动柴油机消防水泵运行一次。",[430,431,432,433],{"key":20,"text":369,"correct":22},{"key":24,"text":371,"correct":22},{"key":27,"text":373,"correct":29},{"key":31,"text":375,"correct":22},{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":24,"analysis":33},965106,"每（ ）应检查柴油机泵储油箱的储油量。",[438,439,440,441],{"key":20,"text":369,"correct":22},{"key":24,"text":371,"correct":29},{"key":27,"text":373,"correct":22},{"key":31,"text":375,"correct":22},{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":20,"analysis":33},965107,"每（ ）应对柴油机消防水泵的启动电池的电量进行检测。",[446,447,448,449],{"key":20,"text":369,"correct":29},{"key":24,"text":371,"correct":22},{"key":27,"text":373,"correct":22},{"key":31,"text":375,"correct":22},{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":31,"analysis":33},965108,"每（ ）应对消防水泵的出流量和压力进行一次试验。",[454,455,456,457],{"key":20,"text":369,"correct":22},{"key":24,"text":371,"correct":22},{"key":27,"text":373,"correct":22},{"key":31,"text":375,"correct":29},{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":24,"analysis":33},965109,"每（ ）应模拟消防水泵自动控制的条件自动启动消防水泵运转一次。",[462,463,464,465],{"key":20,"text":369,"correct":22},{"key":24,"text":371,"correct":29},{"key":27,"text":373,"correct":22},{"key":31,"text":375,"correct":22},{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":27,"analysis":33},965110,"每（ ）应手动启动消防水泵运转一次，并应检查供电电源的情况。",[470,471,472,473],{"key":20,"text":369,"correct":22},{"key":24,"text":371,"correct":22},{"key":27,"text":373,"correct":29},{"key":31,"text":375,"correct":22},{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":31,"analysis":33},965111,"消防水泵应保证在火灾发生后规定的时间内正常工作，当控制柜内的控制线路发生故障，需采用手动机械启泵时，应确保消防水泵在报警（ ）min内正常工作。",[478,479,480,481],{"key":20,"text":41,"correct":22},{"key":24,"text":397,"correct":22},{"key":27,"text":43,"correct":22},{"key":31,"text":255,"correct":29},{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":27,"analysis":33},965112,"消防水泵控制柜与消防水泵设置在同一空间时，其防护等级不应低于（ ）。",[486,488,490,492],{"key":20,"text":487,"correct":22},"IP35",{"key":24,"text":489,"correct":22},"IP45",{"key":27,"text":491,"correct":29},"IP55",{"key":31,"text":493,"correct":22},"IP65",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":24,"analysis":33},965113,"气压水罐安装时其四周要设检修通道，其宽度不宜小于（ ）m，消防气压给水设备顶部至楼板或梁底的距离不宜小于（ ）m。",[498,500,502,504],{"key":20,"text":499,"correct":22},"0.6，0.6",{"key":24,"text":501,"correct":29},"0.7，0.6",{"key":27,"text":503,"correct":22},"0.7，0.7",{"key":31,"text":505,"correct":22},"0.8，0.6",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":31,"analysis":33},965114,"消防水泵出水管上应设置圧力表，压力表的直径不应小于（ ）mm，并采用直径不小于（ ）mm的缓冲管与消防水泵进出口管相接。并应设置关断阀门。",[510,512,514,516],{"key":20,"text":511,"correct":22},"60，3",{"key":24,"text":513,"correct":22},"60，5",{"key":27,"text":515,"correct":22},"100，4",{"key":31,"text":517,"correct":29},"100，6",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":24,"analysis":33},965115,"每台消防水泵出水管上应设置（ ）的试水管。",[522,524,526,528],{"key":20,"text":523,"correct":22},"DN50",{"key":24,"text":525,"correct":29},"DN65",{"key":27,"text":527,"correct":22},"DN80",{"key":31,"text":529,"correct":22},"DN100",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":20,"analysis":33},965116,"消防水泵吸水管可设置管道过滤器，管道过滤器的过水面积应大于管道过水面积的（ ）倍，且孔径不宜小于（ ）mm。",[534,536,538,540],{"key":20,"text":535,"correct":29},"4，3",{"key":24,"text":537,"correct":22},"3，3",{"key":27,"text":539,"correct":22},"3，4",{"key":31,"text":541,"correct":22},"4，4",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":27,"analysis":33},965117,"当消防水泵吸水管管径超过DN（ ）时。宜设置电动阀门。",[546,547,549,551],{"key":20,"text":363,"correct":22},{"key":24,"text":548,"correct":22},"250",{"key":27,"text":550,"correct":29},"300",{"key":31,"text":552,"correct":22},"350",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":20,"analysis":33},965118,"稳压泵的（ ）不应小于消防给水系统管网的正常泄漏量和系统自动启动流量。",[557,559,561,563],{"key":20,"text":558,"correct":29},"设计流量",{"key":24,"text":560,"correct":22},"额定流量",{"key":27,"text":562,"correct":22},"最大流量",{"key":31,"text":564,"correct":22},"最小流量",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":24,"analysis":33},965119,"室内净空高度超过7m的多层民用建筑等场所的消火栓栓口动压。不应小于（ ）MPa。",[569,570,572,574],{"key":20,"text":326,"correct":22},{"key":24,"text":571,"correct":29},"0.25",{"key":27,"text":573,"correct":22},"0.35",{"key":31,"text":575,"correct":22},"0.45",[577,580,583,586,589,592],{"id":15,"name":578,"category":7,"favorite":579},"领导干部任职前廉政法规知识测试题",92,{"id":581,"name":582,"category":7,"favorite":15},595,"建筑结构与设备",{"id":584,"name":585,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":587,"name":588,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":590,"name":591,"category":7,"favorite":8},534,"BIM工程师",{"id":593,"name":591,"category":7,"favorite":8},535]