[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-17":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":580},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,17,50,2716,[13,34,46,58,70,82,94,106,116,128,140,152,162,172,184,194,203,215,225,237,249,261,273,281,291,303,311,323,335,344,353,365,377,389,401,413,425,437,449,461,473,484,496,508,520,532,540,552,560,572],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},965019,1,"单选题","关于灭火器结构检查的表述，不属于合格判定标定标准的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","灭火器开启机构灵活、性能可靠，可倒置开启和使用",true,{"key":24,"text":25,"correct":26},"B","提把和压把无机械损伤，表面不得有毛刺、锐边等影响操作的缺陷",false,{"key":28,"text":29,"correct":26},"C","灭火器头（阀门）外观完好、无破损",{"key":31,"text":32,"correct":26},"D","安装有保险装置，保险装置的铅封（塑料带、线封）完好无损","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},965020,"MFT50中的50表示（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"批号",{"key":24,"text":41,"correct":22},"重量为50公斤",{"key":28,"text":43,"correct":26},"体积为50升",{"key":31,"text":45,"correct":26},"长度为50米",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},965021,"灭火器配置场所的危险等级可分为（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"严重危险级、中危险级",{"key":24,"text":53,"correct":26},"重危险级、轻危险级、安全级",{"key":28,"text":55,"correct":22},"严重危险级、中危险级、轻危险级",{"key":31,"text":57,"correct":26},"仓库危险级、严重危险级、中危险级、轻危险级",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},965022,"灭火器存在一定情形将予以报废，灭火器报废后，建筑使用管理单位按照等效替代的原则对灭火器进行更换。水基型灭火器出厂期满（ ）年予以报废。",[62,64,66,68],{"key":20,"text":63,"correct":22},"6",{"key":24,"text":65,"correct":26},"8",{"key":28,"text":67,"correct":26},"10",{"key":31,"text":69,"correct":26},"12",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},965023,"建筑灭火器检查（测）是在规定期限内根据消防技术标准对灭火器配置和外观进行的全面检查。候车（机、船）室、歌舞娛乐放映游艺等人员密集的公共场所以及堆场、罐区、石油化工装置区、加油站、锅炉房、地下室等场所配置的灭火器每（ ）月检查1次。",[74,76,78,80],{"key":20,"text":75,"correct":22},"0.5",{"key":24,"text":77,"correct":26},"1",{"key":28,"text":79,"correct":26},"1.5",{"key":31,"text":81,"correct":26},"2",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},965024,"按照相关消防设计规范要求对建筑物进行灭火配置验收，项目缺陷划分为严重缺陷项 A、重缺陷项B和轻缺陷项C。下列灭火器配置验收合格的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"A=0，B=1，C=4",{"key":24,"text":89,"correct":22},"A=0，B=1，C=3",{"key":28,"text":91,"correct":26},"A=0，B=2，C=2",{"key":31,"text":93,"correct":26},"A=0，B=2，C=3",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},965025,"A类火灾配置场所中严重危险级手提式灭火器最大保护距离（m）是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"9",{"key":24,"text":101,"correct":22},"15",{"key":28,"text":103,"correct":26},"20",{"key":31,"text":105,"correct":26},"25",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},965026,"设有室内消火栓系统和灭火系统的建筑，其灭火器配置设计计算的修正系数取值是（ ）。",[110,111,113,114],{"key":20,"text":75,"correct":22},{"key":24,"text":112,"correct":26},"0.7",{"key":28,"text":77,"correct":26},{"key":31,"text":115,"correct":26},"1.3",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":28,"analysis":33},965027,"按照国家标准《火灾分类》GB\u002FT4968-2008的规定。下列物质发生火灾属于A类火灾的是（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":26},"氢气",{"key":24,"text":123,"correct":26},"丁二烯",{"key":28,"text":125,"correct":22},"纸盒",{"key":31,"text":127,"correct":26},"氨气",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":28,"analysis":33},965028,"按照国家标准《火灾分类》GB\u002FT4968-2008的规定，下列特质发生火灾属于A类火灾的是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":26},"乙烷",{"key":24,"text":135,"correct":26},"水煤气",{"key":28,"text":137,"correct":22},"赤磷",{"key":31,"text":139,"correct":26},"变压器",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":31,"analysis":33},965029,"某建筑灭火器配置验收时。存在以下问题：①灭火器被遮挡：②灭火器箱箱门开启不灵活；③灭火器箱的箱体正面和灭火器设置点附近的墙面上没有设置指示灭火器位位置的标志：④有视线降碍的灭火器配置点。没有在其酲目部位设置指示灭火器位置的发光标识。请问灭火器配置验收判断结果为（ ）。",[144,146,148,150],{"key":20,"text":145,"correct":26},"A=0，B=0，C=4，验收合格",{"key":24,"text":147,"correct":26},"A=0，B=1，C=3，验收合格",{"key":28,"text":149,"correct":26},"A=0，B=2，C=2，验收合格",{"key":31,"text":151,"correct":22},"验收不合格",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":20,"analysis":33},965030,"灭火器充装置（ ）时。应配有喷射软管，其长度不小于400mm。",[156,158,160,161],{"key":20,"text":157,"correct":22},"＞3kg（L）",{"key":24,"text":159,"correct":26},"＞5kg（L）",{"key":28,"text":157,"correct":26},{"key":31,"text":159,"correct":26},{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":24,"analysis":33},965031,"手提式灭火器宜设置在灭火器箱内或挂钩、托架上，其顶部离地面高度不宜大于（ ）m。",[166,167,168,170],{"key":20,"text":81,"correct":26},{"key":24,"text":79,"correct":22},{"key":28,"text":169,"correct":26},"1.1",{"key":31,"text":171,"correct":26},"0.9",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":31,"analysis":33},965032,"下列不属于目前常用灭火器的主要类型的是（ ）。",[176,178,180,182],{"key":20,"text":177,"correct":26},"水基型灭火器",{"key":24,"text":179,"correct":26},"干粉灭火器",{"key":28,"text":181,"correct":26},"二氧化碳灭火器",{"key":31,"text":183,"correct":22},"化学泡沫灭火剂",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":24,"analysis":33},965033,"手提式、推车式干粉灭火器、洁净气体灭火器、二氧化碳灭火器首次维修以后每满（ ）年，建筑使用管理单位需要向灭火器维修企业送修。",[188,189,190,192],{"key":20,"text":77,"correct":26},{"key":24,"text":81,"correct":22},{"key":28,"text":191,"correct":26},"3",{"key":31,"text":193,"correct":26},"4",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":20,"analysis":33},965034,"灭火器结构检查中主要检查灭火器结构以及保险机构、器头（阀门）、压力指示器、喷射软管及喷嘴、推车式灭火器推行机构等装配质量。下列灭火器结构检查不属于判定合格标准的是（ ）。",[198,199,200,202],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"key":28,"text":201,"correct":26},"灭火器器头（阀门）外观完好、无破损",{"key":31,"text":32,"correct":26},{"id":204,"libraryId":5,"type":15,"typeLabel":16,"stem":205,"options":206,"answer":28,"analysis":33},965035,"灭火器维修合格证外围边框为（ ）实线。",[207,209,211,213],{"key":20,"text":208,"correct":26},"白色",{"key":24,"text":210,"correct":26},"黑色",{"key":28,"text":212,"correct":22},"红色",{"key":31,"text":214,"correct":26},"绿色",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":28,"analysis":33},965036,"建筑灭火器检查中，要求灭火器压力表盘指示器指示在（ ）区域。",[219,220,222,223],{"key":20,"text":212,"correct":26},{"key":24,"text":221,"correct":26},"黄色",{"key":28,"text":214,"correct":22},{"key":31,"text":224,"correct":26},"蓝色",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":31,"analysis":33},965037,"下列对灭火器箱体结构及箱门（盖）开启性能检查中，错误的是（ ）。",[229,231,233,235],{"key":20,"text":230,"correct":26},"翻盖式灭火器箱正面的上挡板在箱盖打开后能够翻转下落",{"key":24,"text":232,"correct":26},"开门式灭火器箱箱门设有箱门关紧装置。且无锁具",{"key":28,"text":234,"correct":26},"灭火器箱箱门、箱盖开启操作轻便灵活，无卡阻",{"key":31,"text":236,"correct":22},"箱门开启角度不小于160°，箱盖开启角度不小于100°",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":31,"analysis":33},965038,"七氟丙烷灭火剂主要依靠氟（ ）灭火。",[241,243,245,247],{"key":20,"text":242,"correct":26},"降低温度",{"key":24,"text":244,"correct":26},"降低氧浓度",{"key":28,"text":246,"correct":26},"稀释可燃物",{"key":31,"text":248,"correct":22},"破坏和抑制链式反应",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":28,"analysis":33},965039,"送修灭火器时。一次送修数量不得超过计算单元配置灭火器总数量的（ ）。",[253,255,257,259],{"key":20,"text":254,"correct":26},"1\u002F2",{"key":24,"text":256,"correct":26},"1\u002F3",{"key":28,"text":258,"correct":22},"1\u002F4",{"key":31,"text":260,"correct":26},"1\u002F5",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":33},965040,"木材、棉花火灾是（ ）火灾。",[265,267,269,271],{"key":20,"text":266,"correct":22},"A类",{"key":24,"text":268,"correct":26},"B类",{"key":28,"text":270,"correct":26},"C类",{"key":31,"text":272,"correct":26},"D类",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":24,"analysis":33},965041,"沥青火灾是（ ）火灾。",[277,278,279,280],{"key":20,"text":266,"correct":26},{"key":24,"text":268,"correct":22},{"key":28,"text":270,"correct":26},{"key":31,"text":272,"correct":26},{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":28,"analysis":33},965042,"干粉灭火剂灭火的主要机理是（ ）。",[285,286,287,289],{"key":20,"text":244,"correct":26},{"key":24,"text":242,"correct":26},{"key":28,"text":288,"correct":22},"抑制链式反应和降低氧浓度",{"key":31,"text":290,"correct":26},"降低氧浓度和降低温度",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":24,"analysis":33},965043,"C类火灾是指（ ）。",[295,297,299,301],{"key":20,"text":296,"correct":26},"固体火灾",{"key":24,"text":298,"correct":22},"气体火灾",{"key":28,"text":300,"correct":26},"液体火灾",{"key":31,"text":302,"correct":26},"金属火灾",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":28,"analysis":33},965044,"在 B、C类火灾场所灭火器的最低配置基准。轻危险级单位灭火级别最大保护面积（ ）。",[307,308,309,310],{"key":20,"text":77,"correct":26},{"key":24,"text":75,"correct":26},{"key":28,"text":79,"correct":22},{"key":31,"text":81,"correct":26},{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":31,"analysis":33},965045,"厨房火灾场所配置（ ）灭火器是错误的。",[315,317,319,321],{"key":20,"text":316,"correct":26},"泡沫",{"key":24,"text":318,"correct":26},"磷酸铵盐干粉",{"key":28,"text":320,"correct":26},"碳酸氢钠干粉",{"key":31,"text":322,"correct":22},"抗溶性",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":31,"analysis":33},965046,"灭火器挂钩、托架安装后。应能够承受（ ）的手提式灭火器（当手提式灭火器质量小于45kg时，按45kg计）的静荷戟，承载5分祌后，不出现松动、脱落、断裂和明显变形等现象。",[327,329,331,333],{"key":20,"text":328,"correct":26},"2倍",{"key":24,"text":330,"correct":26},"3倍",{"key":28,"text":332,"correct":26},"4倍",{"key":31,"text":334,"correct":22},"5倍",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":28,"analysis":33},965047,"按照国家标准《建筑灭火器配置设计规范》（GB501402005）的规定，对于一住宅楼层灭火器配置单元面积400m2，需要至少配置（ ）具灭火器。",[339,340,341,342],{"key":20,"text":81,"correct":26},{"key":24,"text":191,"correct":26},{"key":28,"text":193,"correct":22},{"key":31,"text":343,"correct":26},"5",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":31,"analysis":33},965048,"D类火灾是指（ ）。",[348,350,351,352],{"key":20,"text":349,"correct":26},"固休火灾",{"key":24,"text":298,"correct":26},{"key":28,"text":300,"correct":26},{"key":31,"text":302,"correct":22},{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":24,"analysis":33},965049,"在灭火器配置计算中计算单元保护面积表述错误的是（ ）。",[357,359,361,363],{"key":20,"text":358,"correct":26},"建筑物按照其建筑面积确定",{"key":24,"text":360,"correct":22},"建筑物按照其占地面积确定",{"key":28,"text":362,"correct":26},"可燃物露天堆场应按堆垛的占地面积确定",{"key":31,"text":364,"correct":26},"甲乙丙液体储罐区，可燃气体储罐区应按储罐的占地面积确定。",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":20,"analysis":33},965050,"相线与相线、相线与零线（或地线）在某一点由于绝缘损坏等原因造成相碰或相接，引起电气回路中电流突然堆增大的现象，称为（ ）。",[369,371,373,375],{"key":20,"text":370,"correct":22},"短路",{"key":24,"text":372,"correct":26},"接触不良",{"key":28,"text":374,"correct":26},"过载",{"key":31,"text":376,"correct":26},"漏电",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":31,"analysis":33},965051,"MTT20表示（ ）。",[381,383,385,387],{"key":20,"text":382,"correct":26},"20L推车式水型灭火器",{"key":24,"text":384,"correct":26},"20L推车式泡沫灭火器",{"key":28,"text":386,"correct":26},"20KG推车式磷酸铵盐灭火器",{"key":31,"text":388,"correct":22},"20KG推车式二氧化碳灭火器",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":20,"analysis":33},965052,"MS\u002FQ3表示（ ）。",[393,395,397,399],{"key":20,"text":394,"correct":22},"3L手提式水型灭火器",{"key":24,"text":396,"correct":26},"3L手提式泡沫灭火器",{"key":28,"text":398,"correct":26},"3KG手提式碳酸氢钠灭火器",{"key":31,"text":400,"correct":26},"3KG手提式二氧化碳灭火器",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":28,"analysis":33},965053,"MF\u002FABC6表示（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":26},"6L手提式水型灭火器",{"key":24,"text":408,"correct":26},"6L手提式泡沫灭火器",{"key":28,"text":410,"correct":22},"6KG手提式磷酸铵盐灭火器",{"key":31,"text":412,"correct":26},"6KG手提式二氧化碳灭火器",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":33},965054,"检测发现，消防电话总机显示“插孔故障”，该插孔与总机无法通信，可能是什么原因？（ ）。",[417,419,421,423],{"key":20,"text":418,"correct":26},"该分机与电话总机线路断开",{"key":24,"text":420,"correct":22},"该插孔与电话总机线路断开",{"key":28,"text":422,"correct":26},"电话系统总干线短路、断路",{"key":31,"text":424,"correct":26},"某个电话分机或电话插孔损坏，端子短路导致整条线路短路",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":20,"analysis":33},965055,"电气火灾监控系统线路釆用（ ）与电气火灾监控探测器连接，釆用树形总线形式布线。",[429,431,433,435],{"key":20,"text":430,"correct":22},"通信总线",{"key":24,"text":432,"correct":26},"通信支线",{"key":28,"text":434,"correct":26},"通用线路",{"key":31,"text":436,"correct":26},"专用线路",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":28,"analysis":33},965056,"电气火灾监控系统常见故障原因不包括：（ ）。",[441,443,445,447],{"key":20,"text":442,"correct":26},"设备自身故障",{"key":24,"text":444,"correct":26},"电气火灾监控系统通信线路故障",{"key":28,"text":446,"correct":22},"模块故障",{"key":31,"text":448,"correct":26},"系统部分回路故障",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":31,"analysis":33},965057,"下面哪项不是电气火灾监控系统设备故障的原因？（ ）",[453,455,457,459],{"key":20,"text":454,"correct":26},"监控设备未开启",{"key":24,"text":456,"correct":26},"监控设备损坏",{"key":28,"text":458,"correct":26},"探测器损坏",{"key":31,"text":460,"correct":22},"监控设备线路未连接",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":31,"analysis":33},965058,"对于电气火灾监控系统设备故障的描述不正确的是（ ）。",[465,467,469,471],{"key":20,"text":466,"correct":26},"监控设备未开启，可重新开机",{"key":24,"text":468,"correct":26},"监控设备损坏，应更换",{"key":28,"text":470,"correct":26},"探测器损坏，应更换探测器",{"key":31,"text":472,"correct":22},"监控设备未保养，应定期检测",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":31,"analysis":33},965059,"电气火灾监控系统线路故障的原因不包括（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":26},"监控设备与探测器线路未连接",{"key":24,"text":480,"correct":26},"探测总线短路",{"key":28,"text":482,"correct":26},"探测总线断路",{"key":31,"text":454,"correct":22},{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":31,"analysis":33},965060,"对于电气火灾监控系统线路故障的处理不正确的是？（ ）",[488,490,492,494],{"key":20,"text":489,"correct":26},"线路重新连接，进行测试",{"key":24,"text":491,"correct":26},"检查线路，排除短路后重新进行测试",{"key":28,"text":493,"correct":26},"检查线路，排除断路后重新进行测试",{"key":31,"text":495,"correct":22},"检查线路，排除接地后重新进行测试",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":28,"analysis":33},965061,"应急照明集中电源持续应急时间不达标的原因是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":26},"系统与主板接线不良",{"key":24,"text":503,"correct":26},"集中电源损坏",{"key":28,"text":505,"correct":22},"蓄电池（组）容量不足",{"key":31,"text":507,"correct":26},"控制器主板损坏",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":28,"analysis":33},965062,"控制器显示“应急照明配电箱故障”的原因是（ ）。",[512,514,516,518],{"key":20,"text":513,"correct":26},"主板损坏",{"key":24,"text":515,"correct":26},"输出回路断路、短路",{"key":28,"text":517,"correct":22},"应急照明配电箱损坏",{"key":31,"text":519,"correct":26},"主电源熔丝烧断",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":20,"analysis":33},965063,"检测发现，配电箱主控板损坏，是什么故障？（ ）",[524,526,528,530],{"key":20,"text":525,"correct":22},"应急照明配电箱不能控制灯具应急启动、标志灯指示状态改变",{"key":24,"text":527,"correct":26},"应急照明配电箱输出回路故障",{"key":28,"text":529,"correct":26},"控制器显示“应急照明配电箱故障”",{"key":31,"text":531,"correct":26},"应急照明配电箱显示“主电故障”",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":28,"analysis":33},965064,"应急照明配电箱损坏是起什么故障？（ ）",[536,537,538,539],{"key":20,"text":525,"correct":26},{"key":24,"text":527,"correct":26},{"key":28,"text":529,"correct":22},{"key":31,"text":531,"correct":26},{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":31,"analysis":33},965065,"若蓄电池容量不足，检测时会报出什么故障？（ ）",[544,546,548,550],{"key":20,"text":545,"correct":26},"灯具面板、灯罩有明显机械损伤",{"key":24,"text":547,"correct":26},"灯具光源不能应急点亮",{"key":28,"text":549,"correct":26},"标志灯标识信息不完整",{"key":31,"text":551,"correct":22},"自带电源型灯具持续应急时间不满足要求",{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":31,"analysis":33},965066,"若消防应急灯具损坏，检测时不会报哪项故障？（ ）",[556,557,558,559],{"key":20,"text":545,"correct":26},{"key":24,"text":547,"correct":26},{"key":28,"text":549,"correct":26},{"key":31,"text":551,"correct":22},{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":20,"analysis":33},965067,"集中电源或应急照明配电箱输出端子接线不良，消防应急照明和疏散指示系统会报什么故障？（ ）",[564,566,568,570],{"key":20,"text":565,"correct":22},"控制器显示集中电源或应急照明配电箱配接的多个“灯具故障”",{"key":24,"text":567,"correct":26},"应急照明控制器不能自动控制系统设备应急启动、标志灯指示状态改变",{"key":28,"text":569,"correct":26},"控制器显示“集中电源或应急照明配电箱故障”",{"key":31,"text":571,"correct":26},"控制器显示某一“灯具故障”",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":24,"analysis":33},965068,"应急照明控制器与火灾报警控制器、输出模块间通信线路断路，消防应急照明和疏散指示系统会报什么故障？（ ）",[576,577,578,579],{"key":20,"text":565,"correct":26},{"key":24,"text":567,"correct":22},{"key":28,"text":569,"correct":26},{"key":31,"text":571,"correct":26},[581,584,587,590,593,596],{"id":15,"name":582,"category":7,"favorite":583},"领导干部任职前廉政法规知识测试题",92,{"id":585,"name":586,"category":7,"favorite":15},595,"建筑结构与设备",{"id":588,"name":589,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":591,"name":592,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":594,"name":595,"category":7,"favorite":8},534,"BIM工程师",{"id":597,"name":595,"category":7,"favorite":8},535]