[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":577},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,15,50,2716,[13,34,46,57,68,80,91,100,112,124,136,148,160,168,180,191,203,215,227,239,251,263,274,286,298,310,321,332,344,356,365,376,386,397,407,419,430,439,448,458,470,482,491,500,512,521,529,541,553,565],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},964917,1,"单选题","单台消防水泵的最小额定流量不应小于（ ）L\u002Fs。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","10",true,{"key":24,"text":25,"correct":26},"B","15",false,{"key":28,"text":29,"correct":26},"C","20",{"key":31,"text":32,"correct":26},"D","25","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},964918,"当室内消火栓动压力大于（ ）MPa时必须设置减压装置。",[38,40,42,44],{"key":20,"text":39,"correct":26},"0.2",{"key":24,"text":41,"correct":26},"0.4",{"key":28,"text":43,"correct":26},"0.5",{"key":31,"text":45,"correct":22},"0.7",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},964919,"消防水池应设置取水口（井），且吸水高度不应大于（ ）m。",[50,51,53,55],{"key":20,"text":21,"correct":26},{"key":24,"text":52,"correct":26},"8",{"key":28,"text":54,"correct":26},"7",{"key":31,"text":56,"correct":22},"6",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":28,"analysis":33},964920,"控制盘备用电源容量应满足正常监视状态下连续工作（ ）h，其间应保证系统可靠启动。",[61,62,64,66],{"key":20,"text":52,"correct":26},{"key":24,"text":63,"correct":26},"12",{"key":28,"text":65,"correct":22},"24",{"key":31,"text":67,"correct":26},"48",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":20,"analysis":33},964921,"稳压设备的管路上应设置安全阀，其开启压力不大于最高的工作压力的（ ）倍。",[72,74,76,78],{"key":20,"text":73,"correct":22},"1.1",{"key":24,"text":75,"correct":26},"1.5",{"key":28,"text":77,"correct":26},"2",{"key":31,"text":79,"correct":26},"2.2",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":20,"analysis":33},964922,"气压给水设备的安全阀应能在规定的开启压力下动作，开启压力不得大于设备最高工作压力的（ ）倍。",[84,86,87,89],{"key":20,"text":85,"correct":22},"1.05",{"key":24,"text":73,"correct":26},{"key":28,"text":88,"correct":26},"1.2",{"key":31,"text":90,"correct":26},"1.25",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":28,"analysis":33},964923,"不论是自灌式或吸水式的消防泵，在吸水口处一般都加设喇叭口，喇叭口直径为吸水管直径的（ ）倍。",[95,96,97,98],{"key":20,"text":88,"correct":26},{"key":24,"text":75,"correct":26},{"key":28,"text":77,"correct":22},{"key":31,"text":99,"correct":26},"3",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":20,"analysis":33},964924,"不论是自灌式或吸水式的消防泵，吸水管进水口在水池最低水位时应有不小于（ ）的淹没深度，以避免在水泵工作时，吸水管水面产生漩涡，使水泵吸入空气。",[104,106,108,110],{"key":20,"text":105,"correct":22},"0.3m",{"key":24,"text":107,"correct":26},"0.5m",{"key":28,"text":109,"correct":26},"0.6mm",{"key":31,"text":111,"correct":26},"0.7mm",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":31,"analysis":33},964925,"消防对讲电话单路通话断开的排查方法是（ ）",[116,118,120,122],{"key":20,"text":117,"correct":26},"脱开外部线路，故障仍然存在，需更换电话总机",{"key":24,"text":119,"correct":26},"脱开外部线路故障恢复，需分段检查外接总线找出故障点",{"key":28,"text":121,"correct":26},"测试消防电话分机与主机间相互呼叫与通话，呼叫铃声和通话语音应清晰",{"key":31,"text":123,"correct":22},"用一个51K电阻接在输出端子T+T-上，如果故障消除，说明外部线路出现问题，需分段检查外接线路找出故障点",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":28,"analysis":33},964926,"故障功能检查：改变任意一路采样管的气流，使探测器处于故障状态，探测器或其控制装置应在（ ）s内发出故障信号。",[128,130,132,134],{"key":20,"text":129,"correct":26},"30",{"key":24,"text":131,"correct":26},"60",{"key":28,"text":133,"correct":22},"100",{"key":31,"text":135,"correct":26},"120",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":20,"analysis":33},964927,"在卷门机电源发生故障时，应能在控制器的控制下由控制器供电电源启动速放控制装置，实现防火卷帘自重下降，并可在中限位置使防火卷帘停止并延时，延时结束后再次启动速放控制装置，在防火卷帘到达下限位置时停止速放控制装置。在卷门机电源和控制器主电源都处于故障状态时，控制器应能够在（ ）的支持下完成上述功能。 A.蓄电池 B.备用电源",[140,142,144,146],{"key":20,"text":141,"correct":22},"双电源",{"key":24,"text":143,"correct":26},"发电机",{"key":28,"text":145,"correct":26},"?",{"key":31,"text":147,"correct":26},"不会",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":20,"analysis":33},964928,"报警控制器蓄电池单节电池电压一般低于（ ）V即为欠压，如果充电几小时后仍然不能升到（ ）V，证明电池损坏。",[152,154,156,158],{"key":20,"text":153,"correct":22},"10；12",{"key":24,"text":155,"correct":26},"8；12",{"key":28,"text":157,"correct":26},"8；10",{"key":31,"text":159,"correct":26},"9；12",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":28,"analysis":33},964929,"消防水池进水管应根据有效容积和补水时间确定，补水时间不宜大于（ ）h。",[164,165,166,167],{"key":20,"text":29,"correct":26},{"key":24,"text":129,"correct":26},{"key":28,"text":67,"correct":22},{"key":31,"text":131,"correct":26},{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":31,"analysis":33},964931,"下面哪一项不是泡沬比例混合装置无法形成或不能按比例形成泡沫混合液的原因（ ）。",[172,174,176,178],{"key":20,"text":173,"correct":26},"泡沫液因储存环境不符合要求，失效变质",{"key":24,"text":175,"correct":26},"装置相关阀门、管道连接件密封失效，发生泄漏，而导致装置无法正常工作",{"key":28,"text":177,"correct":26},"消防水因含有较多杂质，运行中将水轮机损坏",{"key":31,"text":179,"correct":22},"装置中的安全阀故陷、损坏，导致装置无法正常工作",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":20,"analysis":33},964932,"下列那一项不是泡沫产生装置无法发泡或发泡不正常的原因（ ）。",[184,185,187,189],{"key":20,"text":173,"correct":22},{"key":24,"text":186,"correct":26},"泡沫产生装置吸气口被杂物堵塞，导致发泡不正常",{"key":28,"text":188,"correct":26},"外浮顶储罐泡沫导流累喷射口被杂物堵塞，导致泡沬无法正常喷射",{"key":31,"text":190,"correct":26},"低倍数泡沬产生器密封玻璃密封不严或损坏，导致储罐内可燃液体蒸气外泄",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":20,"analysis":33},964933,"对于泡沬产生装置无法发泡或发泡不正常的解决方案不正确的是（ ）。",[195,197,199,201],{"key":20,"text":196,"correct":22},"更换已损坏的胶囊",{"key":24,"text":198,"correct":26},"定期检査吸气口及清理杂物",{"key":28,"text":200,"correct":26},"定期检査喷射口及清理杂物",{"key":31,"text":202,"correct":26},"更换密封玻璃，并重新进行密封性能试验，试验合格后方可安装",{"id":204,"libraryId":5,"type":15,"typeLabel":16,"stem":205,"options":206,"answer":31,"analysis":33},964934,"下面哪一项不能排除雨淋自动喷水灭火系统自动滴水阀长期渗漏的故障（ ）。",[207,209,211,213],{"key":20,"text":208,"correct":26},"清除阀瓣与阀瓣座之间的杂物",{"key":24,"text":210,"correct":26},"更换橡胶密封件",{"key":28,"text":212,"correct":26},"开启放水控制阀，排除系统侧管道内的余水",{"key":31,"text":214,"correct":22},"检査管道过滤器，清除滤网上的杂质或者更换过滤器",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":31,"analysis":33},964935,"下面哪项不是灭火控制系统常见的问题？（ ）",[219,221,223,225],{"key":20,"text":220,"correct":26},"灭火系统设置条件发生变化",{"key":24,"text":222,"correct":26},"压力容器没有定期检测",{"key":28,"text":224,"correct":26},"灭火剂质量问题",{"key":31,"text":226,"correct":22},"线路连接问题",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":31,"analysis":33},964936,"某单位使用气体灭火系统，对于气体灭火系统的描述不正确的是（ ）。",[231,233,235,237],{"key":20,"text":232,"correct":26},"低压二氧化碳灭火剂储存容器应按要求进行定期检测",{"key":24,"text":234,"correct":26},"灭火剂质量无法通过测压或称重发现同题时，可通过抽样送检或现场快速检测确定",{"key":28,"text":236,"correct":26},"灭火剂储瓶内的虹吸管（引升管）如果破损或腐蚀，将直接影响液化的气体灭火剂喷放，造成灭火失败",{"key":31,"text":238,"correct":22},"防护区域功能发生变化，不宜设置气体灭火系统的，不需变更系统设计",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":28,"analysis":33},964937,"以下哪项不能排除自动跟踪定位射流灭火系统灭火装置射流打不准目标的故障？（ ）",[243,245,247,249],{"key":20,"text":244,"correct":26},"检查探测装置是否存在故障",{"key":24,"text":246,"correct":26},"检查探测装置参数设置是否正确",{"key":28,"text":248,"correct":22},"检查供水管网和灭火装置流道是否有异物堵塞",{"key":31,"text":250,"correct":26},"维修或更换故障部件",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":24,"analysis":33},964938,"喷洒型自动射流灭火装置射流但不旋转，应检查灭火装置（ ）是否存在故障，维修或更换故障部件。",[255,257,259,261],{"key":20,"text":256,"correct":26},"阀门",{"key":24,"text":258,"correct":22},"旋转机构",{"key":28,"text":260,"correct":26},"信号处理器",{"key":31,"text":262,"correct":26},"动作机构",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":31,"analysis":33},964939,"检测发现，自动跟踪定位射流灭火系统控制灭火装置上下动作，左右不动作或左右动作、上下不动作，以下描述不正确的是（ ）。",[267,269,271,272],{"key":20,"text":268,"correct":26},"先检查信号处理器是否存在故障",{"key":24,"text":270,"correct":26},"再检查灭火装置动作机构等是否存在故障",{"key":28,"text":250,"correct":26},{"key":31,"text":273,"correct":22},"先检查现场控制箱通信是否存在故障",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":31,"analysis":33},964940,"下面哪项不是自动跟踪定位射流灭火系统的常见故障？（ ）",[278,280,282,284],{"key":20,"text":279,"correct":26},"消防控制室远程手动操作灭火装置上、下、左、右、直流\u002F喷雾不动作",{"key":24,"text":281,"correct":26},"现场控制箱操作灭火装置上、下、左、右、直流\u002F喷雾不动作",{"key":28,"text":283,"correct":26},"控制灭火装置上下动作，左右不动作",{"key":31,"text":285,"correct":22},"火灾报警控制器不报警",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":24,"analysis":33},964941,"下面哪项是固定消防炮灭火系统控制装置中控制主机的常见故障？（ ）",[290,292,294,296],{"key":20,"text":291,"correct":26},"钥匙锁发生故障或密码锁失灵，无法解锁",{"key":24,"text":293,"correct":22},"主机瘫痪",{"key":28,"text":295,"correct":26},"无法远程启动消防水泵",{"key":31,"text":297,"correct":26},"无法打开和关闭控制阀",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":31,"analysis":33},964942,"对于固定消防炮灭火系统控制主机无法打开和关闭控制阀的维修，说法不正确的是？（ ）",[302,304,306,308],{"key":20,"text":303,"correct":26},"检查控制主机、控制阀及电源是否存在故障",{"key":24,"text":305,"correct":26},"检查系统电气电路是否存在故障",{"key":28,"text":307,"correct":26},"排除线路故障",{"key":31,"text":309,"correct":22},"检查控制主机是否存在故障",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":31,"analysis":33},964943,"泡沫比例混合装置无法形成或不能按比例形成泡沫混合液的原因不包括（ ）。",[314,316,318,319],{"key":20,"text":315,"correct":26},"装置中的胶囊因老化承压降低，系统运行时胶囊发生破裂",{"key":24,"text":317,"correct":26},"装置中的平衡阀故障、损坏，导致装置无法正常工作",{"key":28,"text":177,"correct":26},{"key":31,"text":320,"correct":22},"系统管路冲洗不到位",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":28,"analysis":33},964944,"对于泡沬比例混合装置无法形成或不能按比例形成泡沫混合液的维修不正确的是（ ）。",[325,326,328,330],{"key":20,"text":196,"correct":26},{"key":24,"text":327,"correct":26},"检查平衡阀，更换损坏部件，必要时更换整个平衡阀",{"key":28,"text":329,"correct":22},"定期检查吸气口及清理杂物",{"key":31,"text":331,"correct":26},"检查损坏的水轮机，更换损坏的部件，必要时更换整个水轮机",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":28,"analysis":33},964945,"泡沬比例混合装置无法形成或不能按比例形成泡沫混合液，下面哪项不是正确的处理方法（ ）。",[336,338,340,342],{"key":20,"text":337,"correct":26},"检查泄漏部位，确保密封良好，必要时更换泄漏部件",{"key":24,"text":339,"correct":26},"检査平衡阀，更换损坏部件，必要时更换整个平衡阀",{"key":28,"text":341,"correct":22},"检査损坏的压缩机，更换损坏的部件，必要时更换整个压缩机",{"key":31,"text":343,"correct":26},"更换已变质的泡沬液",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":24,"analysis":33},964946,"系统管路冲洗不到位，导致末端水雾喷头堵塞，会造成什么故障（ ）。",[348,350,352,354],{"key":20,"text":349,"correct":26},"泡沬产生装置无法发泡或发泡不正常",{"key":24,"text":351,"correct":22},"泡沬喷雾灭火装置不能正常工作",{"key":28,"text":353,"correct":26},"泡沬比例混合装置无法形成泡沬混合液",{"key":31,"text":355,"correct":26},"泡沫比例混合装置不能按比例形成泡沫混合液",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":31,"analysis":33},964947,"检测发现，自动跟踪定位射流灭火系统灭火装置上、下、左、右、直流\u002F喷雾动作卡阻、迟缓，需要如何排除故障（ ）。",[360,361,362,363],{"key":20,"text":268,"correct":26},{"key":24,"text":270,"correct":26},{"key":28,"text":250,"correct":26},{"key":31,"text":364,"correct":22},"检查灭火装置动作机构，维修或更换故障部件",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":24,"analysis":33},964948,"检测发现，自动跟踪定位射流灭火系统灭火装置无法自动扫描以下处理不正确的是（ ）。",[369,371,373,375],{"key":20,"text":370,"correct":26},"先检查系统控制主机参数设置是否错误",{"key":24,"text":372,"correct":22},"先检查信号处理器是否存在故障，再检查灭火装置动作机构等是否存在故障",{"key":28,"text":374,"correct":26},"再检查信号处理器、灭火装置是否存在故障",{"key":31,"text":250,"correct":26},{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":31,"analysis":33},964949,"检测发现，现场控制箱操作灭火装置上、下、左、右、直流\u002F喷雾不动作，以下描述不正确的是（ ）。",[380,382,384,385],{"key":20,"text":381,"correct":26},"先检查远程通信是否存在故障",{"key":24,"text":383,"correct":26},"再逐步检查控制主机，信号处理器、灭火装置动作机构等是否存在故障",{"key":28,"text":250,"correct":26},{"key":31,"text":273,"correct":22},{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":20,"analysis":33},964950,"当固定消防炮灭火系统无线遥控器出现（ ）故障时，检查电池电量是否过低，检查按键面板是否存在故障。更换电池，维修按键面板。",[390,392,394,396],{"key":20,"text":391,"correct":22},"遥控器按键无反应或反应不灵敏",{"key":24,"text":393,"correct":26},"无法选择消防炮",{"key":28,"text":395,"correct":26},"无法控制消防炮动作",{"key":31,"text":297,"correct":26},{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":31,"analysis":33},964951,"当固定消防炮灭火系统现场控制箱出现（ ）故障时，应维修设备或更换面板。",[401,403,404,406],{"key":20,"text":402,"correct":26},"现场和远程状态无法切换",{"key":24,"text":297,"correct":26},{"key":28,"text":405,"correct":26},"无法启动消防水泵",{"key":31,"text":291,"correct":22},{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":31,"analysis":33},964952,"关于固定消防炮灭火系统控制装置的说法不正确的是（ ）。",[411,413,415,417],{"key":20,"text":412,"correct":26},"无法打开和关闭控制阀：检查控制主机、控制阀及电源是否存在故障，维修或更换故障部件，再检查系统电气电路是否存在故障，排除线路故障；",{"key":24,"text":414,"correct":26},"无法控制消防炮动作：检查控制主机是否存在故障，维修或更换损坏设备；再检查系统电气线路是否存在故障，排除线路故障；",{"key":28,"text":416,"correct":26},"无法操作及控制：检查通信是否正常，再对线路进行检查，维修故障；",{"key":31,"text":418,"correct":22},"无法远程启动消防水泵：检查通信是否正常，再对线路进行检查，维修故障",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":28,"analysis":33},964953,"对于固定消防炮灭火系统控制装置的描述不正确的是（ ）。",[423,425,427,429],{"key":20,"text":424,"correct":26},"主机瘫痪：检查系统供电及主机硬件，维修或更换损坏设备",{"key":24,"text":426,"correct":26},"无法操作及控制；检查通信是否正常，再对线路进行检查，维修故障",{"key":28,"text":428,"correct":22},"无法控制消防炮动作：检查控制主机、控制阀及电源是否存在故障，维修或更换故障部件，再检查系统电气电路是否存在故障，排除线路故障；",{"key":31,"text":412,"correct":26},{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":28,"analysis":33},964954,"固定消防炮灭火系统现场控制箱不会出现什么故障？（ ）",[434,435,436,438],{"key":20,"text":402,"correct":26},{"key":24,"text":297,"correct":26},{"key":28,"text":437,"correct":22},"无法实现主、备泵自动切换",{"key":31,"text":291,"correct":26},{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":24,"analysis":33},964956,"灭火器存在一定情形将予以报废，灭火器报废后，建筑使用管理单位按照等效替代的原则对灭火器进行更换，干粉灭火器、洁净气体灭火器出厂期满（ ）年予以报废。",[443,444,445,447],{"key":20,"text":56,"correct":26},{"key":24,"text":21,"correct":22},{"key":28,"text":446,"correct":26},"11",{"key":31,"text":63,"correct":26},{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":24,"analysis":33},964957,"灭火器维修是指为确保灭火器安全使用和有效灭进行的检查、再充装和必要的部件更换等工作。有一灭火器配置单元配置灭火器16具，送修灭火器时，一次送修数量不得超过（ ）具。",[452,453,455,457],{"key":20,"text":99,"correct":26},{"key":24,"text":454,"correct":22},"4",{"key":28,"text":456,"correct":26},"5",{"key":31,"text":56,"correct":26},{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":20,"analysis":33},964958,"灭火器维修是指为确保灭火器安全使用和有效灭火而对灭火器进行的检查、再充装和必要的部件更换等工作。对于手提式、推车式水基型灭火器出厂期满（ ）年。首次维修以后每满（ ）年，建筑使用管理单位需要分批次向灭火器维修企业送修。",[462,464,466,468],{"key":20,"text":463,"correct":22},"3；1",{"key":24,"text":465,"correct":26},"4；2",{"key":28,"text":467,"correct":26},"5；3",{"key":31,"text":469,"correct":26},"6；4",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":24,"analysis":33},964959,"灭火器配置验收的合格判定标准中要求同一配置单元配置的不同类型的灭火器，其灭火剂类型要求不属于（ ）的灭火剂。",[474,476,478,480],{"key":20,"text":475,"correct":26},"相容",{"key":24,"text":477,"correct":22},"不相容",{"key":28,"text":479,"correct":26},"互补",{"key":31,"text":481,"correct":26},"互通",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":24,"analysis":33},964960,"手提式灭火器设置在灭火器箱内或者挂钩、托架上、环境干燥、洁净的场所可直接将其放置在地面上，其安装设置按照经消防设计审核、备案抽查合格的消防设计文件和安装说明实施。其中对灭火器挂钩、托架等附件安装后。要求能够承受（ ）倍的手提式灭火器的静载荷，承载5min后，不出现松动、脱落、断裂和明显变形等现象。",[486,487,488,489],{"key":20,"text":99,"correct":26},{"key":24,"text":456,"correct":22},{"key":28,"text":54,"correct":26},{"key":31,"text":490,"correct":26},"9",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":28,"analysis":33},964961,"手提式灭火器嵌墙式灭火器箱的安装离度，按照手提式灭火器顶部与地面距离不大于（ ）m。底部与地面距离不小于0.08m的要求确定。",[495,496,498,499],{"key":20,"text":43,"correct":26},{"key":24,"text":497,"correct":26},"1",{"key":28,"text":75,"correct":22},{"key":31,"text":77,"correct":26},{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":28,"analysis":33},964962,"建筑灭火器检查中，要求灭火器压力表盘指示器要求指示在区域（ ）。",[504,506,508,510],{"key":20,"text":505,"correct":26},"红区",{"key":24,"text":507,"correct":26},"黄区",{"key":28,"text":509,"correct":22},"绿色",{"key":31,"text":511,"correct":26},"蓝色",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":31,"analysis":33},964963,"B、C类火灾配置场所中中危险级推车式灭火器最大保护距离（m）是（ ）。",[516,517,518,520],{"key":20,"text":63,"correct":26},{"key":24,"text":25,"correct":26},{"key":28,"text":519,"correct":26},"18",{"key":31,"text":65,"correct":22},{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":28,"analysis":33},964964,"B、C类火灾配置场所灭火器的配置基准中，轻危险级单位灭火级别最大保护面积（m2\u002F B）是（ ）。",[525,526,527,528],{"key":20,"text":497,"correct":26},{"key":24,"text":43,"correct":26},{"key":28,"text":75,"correct":22},{"key":31,"text":77,"correct":26},{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":31,"analysis":33},964965,"下列场所描述属于民用建筑灭火器配置场所中的轻危险等级的是（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":26},"火灾危险性较大，可燃物较多，起火后蔓延较迅速，扑救较难的场所",{"key":24,"text":536,"correct":26},"火灾危险性较小，可燃物较少，起火后蔓延较缓慢，扑救较易的场所。",{"key":28,"text":538,"correct":26},"使用性质较重要，人员较密集，用电用火较多，可燃物较多，起火后蔓延较迅速，扑救较难的场所。",{"key":31,"text":540,"correct":22},"使用性质一般，人员不密集，用电用火较少，可燃物较少。起火后蔓延较缓慢，扑救较易的场所。",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":28,"analysis":33},964966,"按照国家标准《火灾分类》GB\u002FT4968-2008的规定，下列物质发生火灾属于C类火灾的是（ ）。",[545,547,549,551],{"key":20,"text":546,"correct":26},"棉",{"key":24,"text":548,"correct":26},"乙醇",{"key":28,"text":550,"correct":22},"甲烷",{"key":31,"text":552,"correct":26},"变压器",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":20,"analysis":33},964967,"按照国家标准（火灾分类》GB\u002FT4968-2008的规定。下列物质发生属于B类火灾的是（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":22},"氨气",{"key":24,"text":560,"correct":26},"沥青",{"key":28,"text":562,"correct":26},"秫秸",{"key":31,"text":564,"correct":26},"金属钾",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":31,"analysis":33},964968,"按照国家标准《火灾分类》GB\u002FT4968-2008的规定，下列物质发生火灾属于D类火灾的是（ ）。",[569,571,573,575],{"key":20,"text":570,"correct":26},"木材",{"key":24,"text":572,"correct":26},"环氧乙烷",{"key":28,"text":574,"correct":26},"绸布",{"key":31,"text":576,"correct":22},"铝粉",[578,581,584,587,590,593],{"id":15,"name":579,"category":7,"favorite":580},"领导干部任职前廉政法规知识测试题",92,{"id":582,"name":583,"category":7,"favorite":15},595,"建筑结构与设备",{"id":585,"name":586,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":588,"name":589,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":591,"name":592,"category":7,"favorite":8},534,"BIM工程师",{"id":594,"name":592,"category":7,"favorite":8},535]