[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":566},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,14,50,2716,[13,34,44,55,67,79,90,99,109,121,133,145,157,169,178,187,199,211,222,234,246,258,270,282,294,306,318,330,342,354,366,375,384,393,405,413,421,433,445,454,462,474,485,496,505,513,523,535,544,556],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},964866,1,"单选题","民用建筑机械加压送风口的风速不宜大于（ ）m\u002Fs。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","5",false,{"key":24,"text":25,"correct":26},"B","6",true,{"key":28,"text":29,"correct":22},"C","7",{"key":31,"text":32,"correct":22},"D","8","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},964867,"民用建筑机械排烟口的风速不宜大于（ ）m\u002Fs",[38,39,40,42],{"key":20,"text":29,"correct":22},{"key":24,"text":32,"correct":22},{"key":28,"text":41,"correct":22},"9",{"key":31,"text":43,"correct":26},"10",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":24,"analysis":33},964868,"安装在吊项内的排烟管道，其隔热层应釆用不燃烧材料，并应与可燃物保持不小于（ ）cm的距离。",[48,49,51,53],{"key":20,"text":43,"correct":22},{"key":24,"text":50,"correct":26},"15",{"key":28,"text":52,"correct":22},"20",{"key":31,"text":54,"correct":22},"30",{"id":56,"libraryId":5,"type":15,"typeLabel":16,"stem":57,"options":58,"answer":20,"analysis":33},964869,"通风、空调系统管道上的防火阀，易熔片动作温度为（ ）℃。",[59,61,63,65],{"key":20,"text":60,"correct":26},"70",{"key":24,"text":62,"correct":22},"280",{"key":28,"text":64,"correct":22},"105",{"key":31,"text":66,"correct":22},"68",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":20,"analysis":33},964870,"建筑的排烟窗应设置在排烟区域的（ ），并应有方便开启的装置。",[71,73,75,77],{"key":20,"text":72,"correct":26},"上部",{"key":24,"text":74,"correct":22},"中部",{"key":28,"text":76,"correct":22},"下部",{"key":31,"text":78,"correct":22},"底部",{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":24,"analysis":33},964871,"当排烟风机及系统中设置有软接头时，该软接头应能在（ ）℃的环境条件下连续工作不少于30min。排烟风机和用于排烟补风的送风风机宜设置在通风机房内。",[83,85,86,88],{"key":20,"text":84,"correct":22},"250",{"key":24,"text":62,"correct":26},{"key":28,"text":87,"correct":22},"200",{"key":31,"text":89,"correct":22},"300",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":20,"analysis":33},964872,"机械加压送风防烟系统和排烟补风系统的室外进风口宜布置在室外排烟口的下方，且高差不宜小于3.0m；当水平布置时，水平距离不宜小于（ ）m。",[94,95,96,97],{"key":20,"text":43,"correct":26},{"key":24,"text":50,"correct":22},{"key":28,"text":52,"correct":22},{"key":31,"text":98,"correct":22},"25",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":28,"analysis":33},964873,"需设置机械排烟设施且室内净高小于等于6.0m的场所应划分防烟分区；每个防烟分区的建筑面积不宜超过（ ）m2，防烟分区不应跨越防火分区。",[103,104,105,107],{"key":20,"text":87,"correct":22},{"key":24,"text":89,"correct":22},{"key":28,"text":106,"correct":26},"500",{"key":31,"text":108,"correct":22},"1000",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":20,"analysis":33},964874,"机械加压送风防烟系统中送风口的风速不宜大于（ ）m\u002Fs。",[113,115,117,119],{"key":20,"text":114,"correct":26},"7.0",{"key":24,"text":116,"correct":22},"8.0",{"key":28,"text":118,"correct":22},"9.0",{"key":31,"text":120,"correct":22},"10.0",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":20,"analysis":33},964875,"排烟风机的全压应满足排烟系统最不利环路的要求。其排烟量应考虑（ ）的漏风量。",[125,127,129,131],{"key":20,"text":126,"correct":26},"10%-20%",{"key":24,"text":128,"correct":22},"10%-30%",{"key":28,"text":130,"correct":22},"20%-30%",{"key":31,"text":132,"correct":22},"30%-40%",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":28,"analysis":33},964876,"建筑机械加压送风和机械排烟的风道釆用金属风道时，其风速（ ）",[137,139,141,143],{"key":20,"text":138,"correct":22},"不应小于20m\u002Fs",{"key":24,"text":140,"correct":22},"不应小于15m\u002Fs",{"key":28,"text":142,"correct":26},"不应大于20m\u002Fs",{"key":31,"text":144,"correct":22},"不应大于15m\u002Fs",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":31,"analysis":33},964877,"建筑的防烟设施可分为机械加压送风的防烟设施和（ ）。",[149,151,153,155],{"key":20,"text":150,"correct":22},"机械排烟设施",{"key":24,"text":152,"correct":22},"排烟风机",{"key":28,"text":154,"correct":22},"防火排烟阀",{"key":31,"text":156,"correct":26},"可开启外窗的自然排烟设施",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":24,"analysis":33},964878,"排烟方式分为（ ）方式或自然排烟方式。",[161,163,165,167],{"key":20,"text":162,"correct":22},"机械送风",{"key":24,"text":164,"correct":26},"机械排烟",{"key":28,"text":166,"correct":22},"机械加压送风",{"key":31,"text":168,"correct":22},"自然通风",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":28,"analysis":33},964879,"防烟方式分为（ ）方式或自然通风方式。",[173,175,176,177],{"key":20,"text":174,"correct":22},"自然排烟",{"key":24,"text":164,"correct":22},{"key":28,"text":166,"correct":26},{"key":31,"text":162,"correct":22},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},964880,"防烟分区内，排烟口距最远点的水平距离不应超过（ ）m。",[182,183,184,185],{"key":20,"text":50,"correct":22},{"key":24,"text":52,"correct":22},{"key":28,"text":54,"correct":26},{"key":31,"text":186,"correct":22},"40",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":28,"analysis":33},964881,"防烟楼梯间风压的余压值应（ ）前室和合用前室的余压。",[191,193,195,197],{"key":20,"text":192,"correct":22},"小于",{"key":24,"text":194,"correct":22},"等于",{"key":28,"text":196,"correct":26},"大于",{"key":31,"text":198,"correct":22},"不小于",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":20,"analysis":33},964882,"通风、空气调节系统的风管道穿越通风、空气调节机房隔墙或楼板处应设（ ）。",[203,205,207,209],{"key":20,"text":204,"correct":26},"排烟防火阀",{"key":24,"text":206,"correct":22},"防火阀",{"key":28,"text":208,"correct":22},"独立的支吊架",{"key":31,"text":210,"correct":22},"防止回流措施",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":33},964883,"如火灾报警控制器采用铅酸蓄电池，每（ ）个月应进行一次蓄电池充放电测试。",[215,217,219,220],{"key":20,"text":216,"correct":22},"1",{"key":24,"text":218,"correct":26},"3",{"key":28,"text":25,"correct":22},{"key":31,"text":221,"correct":22},"12",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":24,"analysis":33},964885,"蓄电池充放电测试的方法错误的是：（ ）。",[226,228,230,232],{"key":20,"text":227,"correct":22},"对控制器进行模拟火警、联动等功能测试。控制器仍能工作30min",{"key":24,"text":229,"correct":26},"对蓄电池充电12h后关闭主电开关，使用备用电源供电",{"key":28,"text":231,"correct":22},"控制器连接百实负载的情况下。正常工作8h",{"key":31,"text":233,"correct":22},"关闭控制器主电开关，使用备用电源工作。直至蓄电池放电至终止电压",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":31,"analysis":33},964886,"对于蓄电池充放电测试的说法错误的是（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":22},"如控制器蓄电池充放电测试能够满足要求，则说明蓄电池容量正常",{"key":24,"text":241,"correct":22},"如控制器蓄电池充放电测试不能满足要求，则需要更换蓄电池",{"key":28,"text":243,"correct":22},"在进行蓄电池充放电测试过程中，备用电源不能满足正常工作要求时，应能通过声光提示备电欠压",{"key":31,"text":245,"correct":26},"备电欠压声光提示可能消音",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":31,"analysis":33},964887,"干粉灭火系统集流管等组件的检查内容不包括：（ ）",[250,252,254,256],{"key":20,"text":251,"correct":22},"检查集流管、驱动气体管道和减压阀的连接部位有无位移、松动",{"key":24,"text":253,"correct":22},"检查高压连接胶管有无变形、裂纹及老化",{"key":28,"text":255,"correct":22},"检查安全防护装置的泄压方向是否正常",{"key":31,"text":257,"correct":26},"检查安全阀、进气阀、出口阀等是否动作炅活",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":28,"analysis":33},964888,"对于干粉储存容器的检查说法不正确的是：（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"检查干粉储存容器的位置与固定方式是否正常",{"key":24,"text":265,"correct":22},"检查干粉罐的附属件是否正常工作",{"key":28,"text":267,"correct":26},"如干粉储罐的使用年限超过6年或发现干粉储罐有明显的腐蚀点，应进行水圧强度试验",{"key":31,"text":269,"correct":22},"检查安全阀、进气阀、出口阀等是否动作灵活",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":31,"analysis":33},964889,"干粉灭火系统联动设备的检查内容不正确的是：（ ）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"检查灭火控制器及手动\u002F自动转换开关是否正常",{"key":24,"text":277,"correct":22},"检查手动启动、停止按钮，喷放指示灯及声光报警装置等相关设备的设置是否正常",{"key":28,"text":279,"correct":22},"每年进行电气控制回路检查",{"key":31,"text":281,"correct":26},"检查启动气瓶组的手动\u002F自动启动是否正常。",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":28,"analysis":33},964890,"干粉灭火系统管道的检查说法不正确的有（ ）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"检查干粉管路有无位移、损坏、腐蚀现象。油漆颜色是否正常，以免出现泄漏面影响系统的喷射性能",{"key":24,"text":289,"correct":22},"干粉输送管严禁进水和进入污物，发现有积水应放出，并将管内用干燥空气吹干",{"key":28,"text":291,"correct":26},"局部应用系统管网至少每年对管网进行一次吹扫，吹扫后应给喷嘴戴好防尘帽",{"key":31,"text":293,"correct":22},"全淹没系统管网至少每两年对管网进行一次吹扫，吹扫后应给喷嘴戴好防尘帽",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":31,"analysis":33},964891,"干粉灭火系统喷头的检查不正确的是（ ）。",[298,300,302,304],{"key":20,"text":299,"correct":22},"检查喷嘴安装位置和方向是否正确",{"key":24,"text":301,"correct":22},"检查喷嘴的密封盖是否密封良好",{"key":28,"text":303,"correct":22},"如果系统附有干粉卷车，要检查卷筒转动是否灵活",{"key":31,"text":305,"correct":26},"操作干粉喷枪，检查动作是否灵活",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":28,"analysis":33},964892,"柴油发电机充放电装置检查维护内容不包括（ ）。",[310,312,314,316],{"key":20,"text":311,"correct":22},"检查外观、按钮及标识应完好并清晰",{"key":24,"text":313,"correct":22},"检查散热口应无异物和遮挡",{"key":28,"text":315,"correct":26},"检查油管及接头处有无漏油现象",{"key":31,"text":317,"correct":22},"检查内部的接线及配套附件应完好，无断路、脱落",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},964893,"柴油发电机组排气系统的检查维护内容错误的是（ ）。",[322,324,326,328],{"key":20,"text":323,"correct":22},"排气管内及出口处应无杂物和遮挡，如有应及时进行清理",{"key":24,"text":325,"correct":26},"机组如发现故障，影响系统正常使用，检查人员应拆下维修",{"key":28,"text":327,"correct":22},"外接排气管应固定牢固，如有松动或产生振动，应及时紧固",{"key":31,"text":329,"correct":22},"外接排气管与机组柴油机增压器之间的柔性连接管应无破损且连接紧固",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":28,"analysis":33},964894,"电气火灾监控设备内部检查及吹扫要求不包括（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":22},"检查控制器接线口的封堵是否完好",{"key":24,"text":337,"correct":22},"检查各接线的绝缘护套是否有显的龟裂、破损",{"key":28,"text":339,"correct":26},"检查控器的音响和显示器件是否完好",{"key":31,"text":341,"correct":22},"检查电路板和组件是否有松动",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":24,"analysis":33},964895,"关于电气火灾监控设备的保养说法不正确的是（ ）。",[346,348,350,352],{"key":20,"text":347,"correct":22},"表面清洁时，用吸尘器清洁控制器的操作面板，控制开关，机箱表面；用微湿的软布擦拭控制器机箱",{"key":24,"text":349,"correct":26},"设备报警功能测试要求：使探测器发出报警信号，检查探测器的报警确认灯点亮情况及控制器的显示情况",{"key":28,"text":351,"correct":22},"检查控制器的打印纸是否缺失，如缺失应予以更换",{"key":31,"text":353,"correct":22},"进行控制器的主备电源切换检查，对于不能满足备电持续工作时间的蓄电池予以更换",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":24,"analysis":33},964896,"电气火灾监控系统日常保养项目不包括（ ），",[358,360,362,364],{"key":20,"text":359,"correct":22},"设备外观",{"key":24,"text":361,"correct":26},"接地测试",{"key":28,"text":363,"correct":22},"内部检查及吹扫",{"key":31,"text":365,"correct":22},"报警功能测试",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":28,"analysis":33},964897,"剩余电流式电气火灾监控探测器、测温式电气火灾监控探测器、故障电弧探测保养项目不包括（ ），",[370,371,373,374],{"key":20,"text":359,"correct":22},{"key":24,"text":372,"correct":22},"运行环境",{"key":28,"text":363,"correct":26},{"key":31,"text":365,"correct":22},{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":28,"analysis":33},964898,"可燃气体报警控制器内部检查及吹扫要求不包括（ ）。",[379,380,381,383],{"key":20,"text":335,"correct":22},{"key":24,"text":337,"correct":22},{"key":28,"text":382,"correct":26},"检查控制器的音响和显示器件是否完好",{"key":31,"text":341,"correct":22},{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":24,"analysis":33},964899,"关于可燃气体报警控制器的保养说法不正确的是（ ）。",[388,390,391,392],{"key":20,"text":389,"correct":22},"表面清洁时，用吸尘器吸除控制器的操作面板，控制开关，机箱的灰尘，用微湿的软布擦拭控制器机箱",{"key":24,"text":349,"correct":26},{"key":28,"text":351,"correct":22},{"key":31,"text":353,"correct":22},{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":31,"analysis":33},964900,"可燃气体探测器设备外观保养要求不包括（ ）。",[397,399,401,403],{"key":20,"text":398,"correct":22},"检查部件是否安装牢固，对松动部位进行紧固",{"key":24,"text":400,"correct":22},"检查部件的外观是否存在明显的机械损伤",{"key":28,"text":402,"correct":22},"检查部件的运行指示灯是否显示正常",{"key":31,"text":404,"correct":26},"操作控制器声光自检按键（钮）检查控器的音响和显示器件是否完好",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":24,"analysis":33},964901,"消防设备电源状态监控器日常保养项目不包括（ ）。",[409,410,411,412],{"key":20,"text":359,"correct":22},{"key":24,"text":361,"correct":26},{"key":28,"text":363,"correct":22},{"key":31,"text":365,"correct":22},{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":28,"analysis":33},964902,"电压、电流、电压\u002F电流传感器保养项目不包括（ ）。",[417,418,419,420],{"key":20,"text":359,"correct":22},{"key":24,"text":372,"correct":22},{"key":28,"text":363,"correct":26},{"key":31,"text":365,"correct":22},{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":33},964903,"电压、电流、电压\u002F电流传感器运行环境保养要求（ ）。",[425,427,429,431],{"key":20,"text":426,"correct":26},"清除传感器周围的可燃物、杂物",{"key":24,"text":428,"correct":22},"清除传感器与互感器或其他设备之间的遮挡物",{"key":28,"text":430,"correct":22},"检查传感器周围是否有漏水、渗水现象",{"key":31,"text":432,"correct":22},"检查传感器的显示是否正常",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":24,"analysis":33},964904,"电压、电流、电压\u002F电流传感器设备外观保养要求不包括（ ）。",[437,439,441,443],{"key":20,"text":438,"correct":22},"检查传感器是否安装牢固，对松动部位进行紧固",{"key":24,"text":440,"correct":26},"检查传感器的外观是否存在明显的机械损伤",{"key":28,"text":442,"correct":22},"检查传感器的运行指示灯是否显示正常",{"key":31,"text":444,"correct":22},"操作监控器声光自检按键（钮），检查控器的音响和显示器件是否完好",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":28,"analysis":33},964905,"防火门门磁开关、电动闭门器保养项目不包括（ ）。",[449,450,451,452],{"key":20,"text":359,"correct":22},{"key":24,"text":372,"correct":22},{"key":28,"text":363,"correct":26},{"key":31,"text":453,"correct":22},"反馈功能测试",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":31,"analysis":33},964906,"防火门门磁开关、电动闭门器设备外观保养要求不包括：（ ）",[458,459,460,461],{"key":20,"text":398,"correct":22},{"key":24,"text":400,"correct":22},{"key":28,"text":402,"correct":22},{"key":31,"text":444,"correct":26},{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":31,"analysis":33},964907,"柴油发电机组进气系统的检查维护内容不正确的是（ ）。",[466,468,470,472],{"key":20,"text":467,"correct":22},"柴油机进气口应布置在空气流通的地方",{"key":24,"text":469,"correct":22},"柴油机进气管内径应不小于200mm",{"key":28,"text":471,"correct":22},"柴油机的进气管弯头应采用大圆弧过渡",{"key":31,"text":473,"correct":26},"空滤器到柴油机减压器的连接管路密封应良好，不得有任何缝隙和泄漏现象",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":31,"analysis":33},964908,"柴油发电机充放电装置检查维护内容说法不正确的是（ ）。",[478,480,482,483],{"key":20,"text":479,"correct":22},"测试的充电功能应正常",{"key":24,"text":481,"correct":22},"检查接地保护应完好",{"key":28,"text":313,"correct":22},{"key":31,"text":484,"correct":26},"检查控制线路是否顺畅",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":28,"analysis":33},964909,"柴油发电机燃油供给系统的检查维护内容不正确的是（ ）。",[489,491,493,494],{"key":20,"text":490,"correct":22},"检查燃油箱盖上的通气孔是否畅通，若孔中有污物应清除干净",{"key":24,"text":492,"correct":22},"检查加入的柴油的标号是否符合要求，油量是否充足",{"key":28,"text":311,"correct":26},{"key":31,"text":495,"correct":22},"检查油管及接头处有无漏油现象，发现问题及时处理解决",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":31,"analysis":33},964910,"剩余电流式电气火灾监控探测器、测温式电气火灾监控探测器、故障电弧探测器设备外观保养要求不包括（ ）。",[500,501,502,503],{"key":20,"text":398,"correct":22},{"key":24,"text":400,"correct":22},{"key":28,"text":402,"correct":22},{"key":31,"text":504,"correct":26},"操作控制器声光自检按键（钮），检查控器的音响和显示器件是否完好",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":28,"analysis":33},964911,"可燃气体探测器保养项目不包括（ ）。",[509,510,511,512],{"key":20,"text":359,"correct":22},{"key":24,"text":372,"correct":22},{"key":28,"text":363,"correct":26},{"key":31,"text":365,"correct":22},{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":28,"analysis":33},964912,"防火门监控器内部检查及收扫要求不包括（ ）。",[517,519,521,522],{"key":20,"text":518,"correct":22},"检查监控器接线口的封堵是否完好",{"key":24,"text":520,"correct":22},"检查各接线的绝缘护套是否有明显的龟裂、破损",{"key":28,"text":339,"correct":26},{"key":31,"text":341,"correct":22},{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":24,"analysis":33},964913,"关于防火门监控器的保养说法不正确的是（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":22},"表面清洁时，用吸尘器清洁控制器的操作面板，控制开关，机箱表面：用微湿的软布擦拭控制器机箱",{"key":24,"text":530,"correct":26},"设备启动、反馈功能测试要求：使探测器发出报警信号，检查探测器的报警确认灯点亮情况及控制器的显示情况",{"key":28,"text":532,"correct":22},"检查监控器的打印纸足否缺失，如缺失应予以更换",{"key":31,"text":534,"correct":22},"进行监控器的主备电源切换检查，对于不能满足备电持续工作时间的蓄电池予以更换",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":24,"analysis":33},964914,"防火门监控器日常保养项目不包括（ ）。",[539,540,541,542],{"key":20,"text":359,"correct":22},{"key":24,"text":361,"correct":26},{"key":28,"text":363,"correct":22},{"key":31,"text":543,"correct":22},"启动、反馈功能测试",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":31,"analysis":33},964915,"现场设备故障应及时维修，若因特殊原因不能及时排除的故障，也可先将其（ ），待故障排除后再将其恢复。",[548,550,552,554],{"key":20,"text":549,"correct":22},"复位",{"key":24,"text":551,"correct":22},"消音",{"key":28,"text":553,"correct":22},"摘除",{"key":31,"text":555,"correct":26},"屏蔽",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":31,"analysis":33},964916,"消防水泵房内的消防水泵重量大于（ ）t时应设置电动起重设备。",[560,562,563,565],{"key":20,"text":561,"correct":22},"0.5",{"key":24,"text":216,"correct":22},{"key":28,"text":564,"correct":22},"2",{"key":31,"text":218,"correct":26},[567,570,573,576,579,582],{"id":15,"name":568,"category":7,"favorite":569},"领导干部任职前廉政法规知识测试题",92,{"id":571,"name":572,"category":7,"favorite":15},595,"建筑结构与设备",{"id":574,"name":575,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":577,"name":578,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":580,"name":581,"category":7,"favorite":8},534,"BIM工程师",{"id":583,"name":581,"category":7,"favorite":8},535]