[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":599},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,13,50,2716,[13,34,46,58,67,79,88,100,110,122,134,143,155,167,176,188,196,208,220,232,244,256,268,280,292,304,316,328,340,352,364,376,388,400,412,424,436,448,460,472,484,496,508,520,532,544,556,566,578,590],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},964815,1,"单选题","汽车库内无直接通向室外的汽车疏散出口的防火分区，当设置机械排烟系统时，应同时设置进风系统，且送风量不宜小于排烟量的（ ）%。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","100",false,{"key":24,"text":25,"correct":22},"B","30",{"key":27,"text":28,"correct":29},"C","50",true,{"key":31,"text":32,"correct":22},"D","80","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},964816,"机械排烟系统担负两个或两个以上防烟分区时，单位排烟量不应小于（ ）m3\u002Fh.m2。",[38,40,42,44],{"key":20,"text":39,"correct":29},"120",{"key":24,"text":41,"correct":22},"150",{"key":27,"text":43,"correct":22},"180",{"key":31,"text":45,"correct":22},"200",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},964817,"防烟楼梯间的加压送风口宜每隔（ ）层设置一个。",[50,52,54,56],{"key":20,"text":51,"correct":22},"每层",{"key":24,"text":53,"correct":29},"2-3",{"key":27,"text":55,"correct":22},"3-4",{"key":31,"text":57,"correct":22},"4-5",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},964818,"机械排烟系统担负一个防烟分区时，单位排烟量不应小于（ ）m3\u002Fh.m2。",[62,64,65,66],{"key":20,"text":63,"correct":29},"60",{"key":24,"text":32,"correct":22},{"key":27,"text":39,"correct":22},{"key":31,"text":41,"correct":22},{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":24,"analysis":33},964819,"活动挡烟垂壁的手动操作按钮应固定安装在便于操作、明显可见处，距楼地面（ ）之间。",[71,73,75,77],{"key":20,"text":72,"correct":22},"1.0m-1.3m",{"key":24,"text":74,"correct":29},"1.3m-1.5m",{"key":27,"text":76,"correct":22},"1.2m-1.5m",{"key":31,"text":78,"correct":22},"l.lm-1.3m",{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":20,"analysis":33},964820,"由两块或两块以上的挡烟垂帘组成的连续性挡烟垂壁，各块之间不应有缝隙，搭接宽度不应小于（ ）mm。",[83,84,85,86],{"key":20,"text":21,"correct":29},{"key":24,"text":41,"correct":22},{"key":27,"text":45,"correct":22},{"key":31,"text":87,"correct":22},"300",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":31,"analysis":33},964821,"固定式挡烟垂壁可釆用隔墙、楼板下不小于（ ）mm的梁或吊项下凸出不小于（ ）mm的不燃烧体。",[92,94,96,98],{"key":20,"text":93,"correct":22},"200；200",{"key":24,"text":95,"correct":22},"300；300",{"key":27,"text":97,"correct":22},"400；400",{"key":31,"text":99,"correct":29},"500；500",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":31,"analysis":33},964822,"排烟防火阀是安装在机械排烟系统的管道上，平时呈开启状态，火灾时当排烟管道内温度达到（ ）℃时关闭，并在一定时间内能满足漏烟量和耐烟完整性要求，起隔烟阻火作用的阀门。",[104,106,107,108],{"key":20,"text":105,"correct":22},"70",{"key":24,"text":41,"correct":22},{"key":27,"text":43,"correct":22},{"key":31,"text":109,"correct":29},"280",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":31,"analysis":33},964823,"下列关于排烟量的选取的说法错误的是（ ）。",[114,116,118,120],{"key":20,"text":115,"correct":22},"当排烟风机担负多个防烟分区时，其风量应按最大一个防烟分区的排烟量、风管（风道）的漏风量及其他未开启排烟阀（口）的漏风量之和计算",{"key":24,"text":117,"correct":22},"对于人防工程，担负一个或两个防烟分区排烟时，应按该部分总面积每平方米不小于60m3\u002Fh计算，但排烟风机的最小排烟风量不应小于7200m3\u002Fh",{"key":27,"text":119,"correct":22},"当公共建筑中庭周围场所设有机械排烟时，中庭的排烟量可按周围场所中最大排烟量的2倍数值计算，且不应小于10700m3\u002Fh",{"key":31,"text":121,"correct":29},"当公共建筑室内与走道或回廊均需设置排烟时其走道或回廊的机械排烟量可按50m3\u002F（h.m2）",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":24,"analysis":33},964824,"补风系统应直接从室外引入空气，补风量不应小于排烟量的（ ）。",[126,128,130,132],{"key":20,"text":127,"correct":22},"30%",{"key":24,"text":129,"correct":29},"50%",{"key":27,"text":131,"correct":22},"80%",{"key":31,"text":133,"correct":22},"100%",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":20,"analysis":33},964825,"根据《建筑设计防火规范》（GB50016）规定，公共建筑中，面积超过（ ）m2，且经常有人停留的地上无窗房间或设固定窗的房间应设置机械排烟设施。",[138,139,140,141],{"key":20,"text":21,"correct":29},{"key":24,"text":45,"correct":22},{"key":27,"text":87,"correct":22},{"key":31,"text":142,"correct":22},"500",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":20,"analysis":33},964826,"每个防烟分区内必须设置排烟口，排烟口应设置在项棚或墙面的（ ）。",[147,149,151,153],{"key":20,"text":148,"correct":29},"上部",{"key":24,"text":150,"correct":22},"中部",{"key":27,"text":152,"correct":22},"下部",{"key":31,"text":154,"correct":22},"里面",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":20,"analysis":33},964827,"机械加压送风系统送风口的风速不宜大于（ ）m\u002Fs。",[159,161,163,165],{"key":20,"text":160,"correct":29},"7",{"key":24,"text":162,"correct":22},"15",{"key":27,"text":164,"correct":22},"20",{"key":31,"text":166,"correct":22},"25",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":31,"analysis":33},964828,"机械加压送风口设置高度为送风口底边离地（ ）mm。",[171,172,173,174],{"key":20,"text":21,"correct":22},{"key":24,"text":45,"correct":22},{"key":27,"text":109,"correct":22},{"key":31,"text":175,"correct":29},"300-600",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":31,"analysis":33},964829,"（ ）对所安装全部防烟排烟系统进行一次联动试验和性能检测，其联动功能和性能参数应符合原设计要求。",[180,182,184,186],{"key":20,"text":181,"correct":22},"每周",{"key":24,"text":183,"correct":22},"每月",{"key":27,"text":185,"correct":22},"每季",{"key":31,"text":187,"correct":29},"每年",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":27,"analysis":33},964830,"当烟道内烟气温度达到（ ）℃时，温度熔断器动作，排烟防火阀自动关闭；温度熔断器更换后，可手动复位。",[192,193,194,195],{"key":20,"text":43,"correct":22},{"key":24,"text":45,"correct":22},{"key":27,"text":109,"correct":29},{"key":31,"text":87,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":20,"analysis":33},964831,"排烟口应设在顶棚上或靠近顶棚的墙面上，且与附近安全出口沿走道方向相邻边缘之间的最小水平距离不应小于（ ）m。",[200,202,204,206],{"key":20,"text":201,"correct":29},"1",{"key":24,"text":203,"correct":22},"1.5",{"key":27,"text":205,"correct":22},"2",{"key":31,"text":207,"correct":22},"3",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":24,"analysis":33},964833,"防烟楼梯间内机械加压送风防烟系统的余压值应为（ ）。",[212,214,216,218],{"key":20,"text":213,"correct":22},"25-30PA",{"key":24,"text":215,"correct":29},"40-50PA",{"key":27,"text":217,"correct":22},"25-40PA",{"key":31,"text":219,"correct":22},"30-40Pa",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":31,"analysis":33},964834,"关于柴油发电机组的说法正确的是（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":22},"应急发电机组有柴油发电机组和燃气轮机发电机组",{"key":24,"text":227,"correct":22},"柴油发电机组的容量应满足整个建筑物内所有消防设备同时运行时的容量要求",{"key":27,"text":229,"correct":22},"当柴油发电机组兼做其他重要设备的备用电源时，还应考虑备用电源的容量",{"key":31,"text":231,"correct":29},"柴油发电机组兼做其他重要设备的备用电源时，要考虑主备电源同时使用的情况",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":27,"analysis":33},964835,"柴油发电机组是一种小型发电设备，是指以（ ）等为燃料，以柴油机为原动机带动发电机发电的动力机械。",[236,238,240,242],{"key":20,"text":237,"correct":22},"汽油",{"key":24,"text":239,"correct":22},"重油",{"key":27,"text":241,"correct":29},"柴油",{"key":31,"text":243,"correct":22},"润滑油",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":27,"analysis":33},964836,"选用轻柴油时，应根据地区气温与季节选用不同牌号（即不同凝点）。下列轻柴油选用错误的是（ ）。",[248,250,252,254],{"key":20,"text":249,"correct":22},"为了保证发动机燃料系统在低温下正常供油，柴油的凝点应比使用地区的最低气温低4-6℃",{"key":24,"text":251,"correct":22},"10号轻柴油适用于有预热设备的高速柴油机",{"key":27,"text":253,"correct":29},"风险率为10%的最低气温值表示最低温度低于该温度的概率为0.01",{"key":31,"text":255,"correct":22},"风险率为10%的最低气温值表示最低温度低于该温度的可能性不超过1\u002F10",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":20,"analysis":33},964837,"消防设备末端配电装置自投自复的工作方式说法不正确的是（ ）。",[260,262,264,266],{"key":20,"text":261,"correct":29},"正常时备用电源断路器供电",{"key":24,"text":263,"correct":22},"当主电源失电时，控制装置使主电源断路器断开，备用电源断路器闭合，备用电源供电",{"key":27,"text":265,"correct":22},"当主电源恢复供电时，控制装置使备用电源断路器断开，主电源断路器闭合，恢复主电源断路器供电",{"key":31,"text":267,"correct":22},"转换时间可调整（0-120s）",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":27,"analysis":33},964838,"以下哪项不是消防设备末端配电装置的功能（ ）。",[272,274,276,278],{"key":20,"text":273,"correct":22},"复位按钮功能",{"key":24,"text":275,"correct":22},"手动-自动转换功能",{"key":27,"text":277,"correct":29},"双备功能",{"key":31,"text":279,"correct":22},"电气互锁功能",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":20,"analysis":33},964839,"关于消防设备末端配电装置的功能的说法不正确的是（ ）。",[284,286,288,290],{"key":20,"text":285,"correct":29},"主电源断路器和备用电源断路器要有电气互锁功能，保证同时有两台断路器闭合",{"key":24,"text":287,"correct":22},"断相保护：当电源任一相断相时，实现转换。",{"key":27,"text":289,"correct":22},"过压保护：当电源电压大于115%Ue（额定工作电压）时，实现转换。",{"key":31,"text":291,"correct":22},"双分功能：设置双分按键，按下双分按键，将主电源、备用电源全部切断。",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":20,"analysis":33},964840,"操作键盘用于对监控器进行操作。按照各按键的功能来划分，不正确的是（ ）。",[296,298,300,302],{"key":20,"text":297,"correct":29},"状态显示类按键",{"key":24,"text":299,"correct":22},"特殊功能类按键",{"key":27,"text":301,"correct":22},"设置功能类按键",{"key":31,"text":303,"correct":22},"字符键",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":27,"analysis":33},964841,"以下关于消防设备电源状态监控器的描述不正确的是（ ）。",[308,310,312,314],{"key":20,"text":309,"correct":22},"打印机釆用的是正面换纸方式的热敏打印机，方便用户更换打印纸。",{"key":24,"text":311,"correct":22},"当主电源断电时，能自动转换到备用电源；当主电源恢复时，能自动转换到主电源。",{"key":27,"text":313,"correct":29},"备用电源满电状态下，能提供监控器在正常监视状态下至少工作12h",{"key":31,"text":315,"correct":22},"回路板用于巡检、釆集、分析、处理与本回路连接的消防设备电源监控传感器的工作状态和消防设备电源状态。",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":31,"analysis":33},964842,"以下哪项不是消防设备电源状态监控器的基本功能？（ ）",[320,322,324,326],{"key":20,"text":321,"correct":22},"消音功能",{"key":24,"text":323,"correct":22},"自检功能",{"key":27,"text":325,"correct":22},"复位功能",{"key":31,"text":327,"correct":29},"信息记录功能",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":31,"analysis":33},964843,"当釆用公用显示器时，消防设备电源状态监控器的信息显示功能不正确的是（ ）。",[332,334,336,338],{"key":20,"text":333,"correct":22},"应优先显示电源中断供电故障信息",{"key":24,"text":335,"correct":22},"其他故障信息的显示不应影响电源中断供电故障信息的显示",{"key":27,"text":337,"correct":22},"电源中断供电故障信息不应与其他信息交替显示",{"key":31,"text":339,"correct":29},"应设循环查询按钮",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":27,"analysis":33},964844,"消防设备电源状态监控器釆用字母（符）_数字显示时，下面说法错误的是：（ ）。",[344,346,348,350],{"key":20,"text":345,"correct":22},"被中断供电故障信息覆盖的其他信息等应手动可查",{"key":24,"text":347,"correct":22},"监控器如具有显示被监控电源的电压值或电流值的功能",{"key":27,"text":349,"correct":29},"显示误差不应大于3%",{"key":31,"text":351,"correct":22},"应能显示当前中断供电的消防设备总数",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":31,"analysis":33},964845,"关于消防设备电源状态监控器的历史事件记录功能不正确的是：（ ）。",[356,358,360,362],{"key":20,"text":357,"correct":22},"监控器应至少能记录999条相关故障信息",{"key":24,"text":359,"correct":22},"记录的相关故障信息可通过监控器或其他辅助设备查询。",{"key":27,"text":361,"correct":22},"故障信息在监控器断电后保持14天",{"key":31,"text":363,"correct":29},"记录信息可循环查询",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":24,"analysis":33},964846,"消防设备电源状态监控器有自检、消音、复位功能，关于这些功能说法错误的是（ ）",[368,370,372,374],{"key":20,"text":369,"correct":22},"监控器应具有手动检查其音响器件、面板所有指示灯和显示器的功能",{"key":24,"text":371,"correct":29},"监控器的自检时间超过3min或不能自动停止自检时，不应影响非自检部位的正常工作",{"key":27,"text":373,"correct":22},"监控器在故障排除后，故障信号可自动或手动复位",{"key":31,"text":375,"correct":22},"监控器的故障声信号应能手动消除，再有故障信号输入时，应能再启动",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":24,"analysis":33},964847,"消防用电设备的配电线路可以明敷的电缆为：（ ）。",[380,382,384,386],{"key":20,"text":381,"correct":22},"阻燃耐火电缆",{"key":24,"text":383,"correct":29},"矿物绝缘电缆",{"key":27,"text":385,"correct":22},"低烟无卤阻燃电缆",{"key":31,"text":387,"correct":22},"低烟无卤耐火电缆",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":27,"analysis":33},964848,"消防用电设备与适宜备用电源种类一览表中消防应急电源不适宜（ ）系统使用。",[392,394,396,398],{"key":20,"text":393,"correct":22},"自动喷水灭火系统",{"key":24,"text":395,"correct":22},"干粉灭火系统",{"key":27,"text":397,"correct":29},"消防电梯",{"key":31,"text":399,"correct":22},"火灾自动报警系统",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":20,"analysis":33},964849,"一类高层民用建筑的供电负荷等级应为（ ）级。",[404,406,408,410],{"key":20,"text":405,"correct":29},"—",{"key":24,"text":407,"correct":22},"二",{"key":27,"text":409,"correct":22},"三",{"key":31,"text":411,"correct":22},"四",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":27,"analysis":33},964850,"下列不需要一级负荷供电的是（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":22},"大型钢铁联合企业",{"key":24,"text":419,"correct":22},"建筑高度大于50m的乙类生产厂房",{"key":27,"text":421,"correct":29},"乙类液体储罐（区）",{"key":31,"text":423,"correct":22},"大型物资仓库",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":24,"analysis":33},964851,"消防负苘是指消防用电设备，根据供电可靠性及中断供电所造成的损失或影响的程度可分为（ ）。",[428,430,432,434],{"key":20,"text":429,"correct":22},"—级负荷和二级负荷",{"key":24,"text":431,"correct":29},"一级负荷、二级负荷和三级负荷",{"key":27,"text":433,"correct":22},"一级负荷、二级负荷、三级负荷和四级负荷",{"key":31,"text":435,"correct":22},"项级负荷、一级负荷和二级负荷",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":24,"analysis":33},964852,"双路电源可手动及自动切换时，自动切换时间不应大于（ ）s；当一路电源与内燃机动力切换时，切换时间不应大于（ ）s。",[440,442,444,446],{"key":20,"text":441,"correct":22},"1，10",{"key":24,"text":443,"correct":29},"2，15",{"key":27,"text":445,"correct":22},"3，20",{"key":31,"text":447,"correct":22},"4，30",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":24,"analysis":33},964853,"消防控制室、消防水泵、消防电梯、防排烟风机房等的供电，应在最末一级配电箱处设置（ ）装置。",[452,454,456,458],{"key":20,"text":453,"correct":22},"手动切换",{"key":24,"text":455,"correct":29},"自动切换",{"key":27,"text":457,"correct":22},"自动或手动切换",{"key":31,"text":459,"correct":22},"自动和手动切换",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":24,"analysis":33},964854,"手动切断消防主电源，闭合备用消防电源，观察（ ）的投入及指示灯的显示，看消防电源是否符合要求。",[464,466,468,470],{"key":20,"text":465,"correct":22},"应急照明",{"key":24,"text":467,"correct":29},"备用消防电源",{"key":27,"text":469,"correct":22},"事故广播",{"key":31,"text":471,"correct":22},"消防水泵",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":20,"analysis":33},964855,"消防设备应急电源输出功率应大于火灾自动报警及联动控制系统全负荷功率的（ ），蓄电池组的容量应保证火灾自动报警及联动控制系统在火灾状态同时工作负荷条件下连续工作（ ）以上。",[476,478,480,482],{"key":20,"text":477,"correct":29},"120%，3h",{"key":24,"text":479,"correct":22},"150%，3h",{"key":27,"text":481,"correct":22},"130%，2h",{"key":31,"text":483,"correct":22},"110%，2h",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":31,"analysis":33},964856,"应急发电机组的容量应满足整个建筑物内（ ）消防设备同时运行时的容量要求。",[488,490,492,494],{"key":20,"text":489,"correct":22},"1\u002F5",{"key":24,"text":491,"correct":22},"1\u002F3",{"key":27,"text":493,"correct":22},"1\u002F2",{"key":31,"text":495,"correct":29},"所有",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":27,"analysis":33},964857,"消防用电设备及消防电梯等的供电，应在其配电线路的最末一级配电箱处（ ）切换。",[500,502,504,506],{"key":20,"text":501,"correct":22},"手动",{"key":24,"text":503,"correct":22},"电动",{"key":27,"text":505,"correct":29},"自动",{"key":31,"text":507,"correct":22},"机械",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":33},964858,"一级负荷应由（ ）电源供电，当一个电源发生故障时，另一个电源应不致同时受到损坏。",[512,514,516,518],{"key":20,"text":513,"correct":22},"一个",{"key":24,"text":515,"correct":29},"两个",{"key":27,"text":517,"correct":22},"三个",{"key":31,"text":519,"correct":22},"四个",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":20,"analysis":33},964859,"关于柴油发电机组的手动启动操作错误的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":29},"如第一次启动失败，应立即尝试进行第二次启动。",{"key":24,"text":527,"correct":22},"如第一次启动失败，应待控制屏警报消除、机组恢复正常停车状态后方可进行第二次启动。",{"key":27,"text":529,"correct":22},"启动后，若机器运转声音异常，说明启动不成功。",{"key":31,"text":531,"correct":22},"启动后，若机器运转声音正常、冷却水泵运转指示灯亮及电路仪表指示正常，则说明启动成功。",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},964860,"关于电气火灾监控系统的报警功能，以下说法错误的是（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":29},"电气火灾监控设备应能接收来自探测器的报警信号，并在30s内发出声、光报警信号，指示报警部位，显示报警时间。",{"key":24,"text":539,"correct":22},"当被探测线路在1s内发生14个及以上半周期的故障电弧时，故障电弧探测器应在30s内发出报警信号。",{"key":27,"text":541,"correct":22},"当被监视部位温度达到报警设定值时，测温式电气火灾监控探测器应在40s内发出报警信号。",{"key":31,"text":543,"correct":22},"当被保护线路剩余电流达到报警设定值时，剩余电流式电气火灾监控探测器应30s内发出报警信号。",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":27,"analysis":33},964861,"对于电气火灾监控系统报警测试方法描述不正确的是（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":22},"釆用剩余电流发生器模拟产生剩余电流，使探测器达到报警条件，进入报警状态",{"key":24,"text":551,"correct":22},"釆用可调温式热风机或者其他可控温度的加温设备给探测器的感温元件加温，使探测器达到报警条件，进入报警状态。",{"key":27,"text":553,"correct":29},"釆用故障电弧模拟发生装置产生剩余电流，使探测器达到报警条件，进入报警状态。",{"key":31,"text":555,"correct":22},"剩余电流发生器通常用于系统生产或验收模拟时测试电气火灾监控探测器灵敏度及报警功能，具有0-1000mA电流调节功能。",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":31,"analysis":33},964862,"机械加压送风管道、排烟管道和补风管道，釆用金属管道时，风速不宜大于（ ）m\u002Fs。",[560,562,563,565],{"key":20,"text":561,"correct":22},"10",{"key":24,"text":162,"correct":22},{"key":27,"text":564,"correct":22},"18",{"key":31,"text":164,"correct":29},{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":24,"analysis":33},964863,"下列关于机械排烟系统要求错误的是（ ）。",[570,572,574,576],{"key":20,"text":571,"correct":22},"排烟管道必须釆用不燃材料制作。",{"key":24,"text":573,"correct":29},"安装在吊项内的排烟管道，其隔热层应釆用不燃烧材料制作，并应与可燃物保持不小于100mm的距离。",{"key":27,"text":575,"correct":22},"设置机械排烟的地下室，应同时设置送风系统，且送风量不宜小于排烟量的50%。",{"key":31,"text":577,"correct":22},"排烟支管上应设有当烟气温度超过280℃时能自行关闭的排烟防火阀。",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":20,"analysis":33},964864,"大型商场中央空调系统的送、回风管穿过机房的隔墙和楼板处，均应按规定设置（ ）。",[582,584,586,588],{"key":20,"text":583,"correct":29},"防火阀",{"key":24,"text":585,"correct":22},"排烟防火阀",{"key":27,"text":587,"correct":22},"防回流措施",{"key":31,"text":589,"correct":22},"防火隔板",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":31,"analysis":33},964865,"在检查排烟阀的关闭可靠性时，使排烟阀处于关闭状态，对于具有几种不同启闭方式的排烟防火阀，每种启闭方式均应进行（ ）次操作。",[594,595,597,598],{"key":20,"text":205,"correct":22},{"key":24,"text":596,"correct":22},"5",{"key":27,"text":160,"correct":22},{"key":31,"text":561,"correct":29},[600,603,606,609,612,615],{"id":15,"name":601,"category":7,"favorite":602},"领导干部任职前廉政法规知识测试题",92,{"id":604,"name":605,"category":7,"favorite":15},595,"建筑结构与设备",{"id":607,"name":608,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":610,"name":611,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":613,"name":614,"category":7,"favorite":8},534,"BIM工程师",{"id":616,"name":614,"category":7,"favorite":8},535]