[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":571},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,12,50,2716,[13,33,45,57,69,81,91,103,115,127,139,151,163,174,186,198,210,222,230,242,254,266,276,288,300,312,323,333,341,353,361,369,380,389,399,411,423,435,443,452,460,468,480,492,504,514,523,535,547,559],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":29,"analysis":32},964765,1,"单选题","以下哪一项不是水幕系统开启报警阀组的控制方式？（ ）",[19,23,25,28],{"key":20,"text":21,"correct":22},"A","自动控制方式",false,{"key":24,"text":21,"correct":22},"B",{"key":26,"text":27,"correct":22},"C","手动应急操作方式",{"key":29,"text":30,"correct":31},"D","机械应急操作方式",true,"",{"id":34,"libraryId":5,"type":15,"typeLabel":16,"stem":35,"options":36,"answer":24,"analysis":32},964766,"关于消防设备末端配电装置的工作原理的说法不正确的是（ ）。",[37,39,41,43],{"key":20,"text":38,"correct":22},"双电源自动切换装置包括自投自复和自投不自复两种功能",{"key":24,"text":40,"correct":31},"对三相四线电网供电的两路电源的三相电压相互检测",{"key":26,"text":42,"correct":22},"当任一相发生过压、欠压（包括缺相），即自动从异常电源切换到正常电源",{"key":29,"text":44,"correct":22},"用于电网一发电系统的产品还能发出发电和卸载信号",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":24,"analysis":32},964767,"消防设备末端配电装置自投不自复的工作方式说法错误的是（ ）。",[49,51,53,55],{"key":20,"text":50,"correct":22},"正常时主电源断路器供电",{"key":24,"text":52,"correct":31},"当主电源失电时，控制装置使主电源断路器闭合，备用电源断路器断开，备用电源供电",{"key":26,"text":54,"correct":22},"当主电源恢复供电时，控制装置维持备用电源断路器供电",{"key":29,"text":56,"correct":22},"转换时间可调整（0-120s）",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":24,"analysis":32},964768,"消防设备末端配电装置的工作方式不包括：（ ）。",[61,63,65,67],{"key":20,"text":62,"correct":22},"自投自复",{"key":24,"text":64,"correct":31},"自投不自复",{"key":26,"text":66,"correct":22},"互为备用",{"key":29,"text":68,"correct":22},"不自投自复",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":24,"analysis":32},964769,"消防设备末端配电装置互为备用的工作方式说法不正确的是（ ）。",[73,75,77,79],{"key":20,"text":74,"correct":22},"平时双路电源不分主、备用电源供电",{"key":24,"text":76,"correct":31},"当正在使用的电源（A电源）失电时，控制装置使该故障电源（A电源）断路器断开，闭合另一路电源（B电源）断路器，确保临时供电",{"key":26,"text":78,"correct":22},"即故障电源（A电源）恢复正常时，也不必釆取转换恢复（A电源）供电",{"key":29,"text":80,"correct":22},"仅在用电源（B电源）发生失电时，控制装置再将供电电源转换至（A电源）供电",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":32},964770,"消防设备末端配电装置电网-发电机的工作方式说法不正确的是（ ）。",[85,86,88,90],{"key":20,"text":50,"correct":22},{"key":24,"text":87,"correct":31},"当主电源失电时，控制装置发出指令（无源常开接点），启动发电机发电，主电源断路器立即断开，备用电源断路器闭合",{"key":26,"text":89,"correct":22},"当主电源恢复供电时，控制装置发出指令，停止发电机发电，经延时后使备用电源断路器断开，主电源断路器闭合，恢复主电源断路器供电",{"key":29,"text":56,"correct":22},{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":26,"analysis":32},964771,"消防设备末端配电装置的功能不包括（ ）。",[95,97,99,101],{"key":20,"text":96,"correct":22},"过压保护",{"key":24,"text":98,"correct":22},"欠压保护",{"key":26,"text":100,"correct":31},"断电保护",{"key":29,"text":102,"correct":22},"复位按钮功能",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":26,"analysis":32},964772,"双电源自动切换装置适用于交流（ ）的两路电源（主电源和备用电源或发电电源），当一路电源发生故障时实现电源之间的自动切换，以保证供电的可靠性和安全性。",[107,109,111,113],{"key":20,"text":108,"correct":22},"30Hz、200V",{"key":24,"text":110,"correct":22},"30Hz、400V",{"key":26,"text":112,"correct":31},"50Hz、400V",{"key":29,"text":114,"correct":22},"50Hz、200V",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":26,"analysis":32},964773,"当消防设备电源发生（ ）故障时，消防设备电源状态监控器不发出故障声、光信号。",[119,121,123,125],{"key":20,"text":120,"correct":22},"断电",{"key":24,"text":122,"correct":22},"过负荷",{"key":26,"text":124,"correct":31},"过流",{"key":29,"text":126,"correct":22},"缺相",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":24,"analysis":32},964774,"当消防设备电源发生断电、过压、欠压、过流、缺相、错相等故障时，消防设备电源状态监控器的状态不准确的是（ ）。",[131,133,135,137],{"key":20,"text":132,"correct":22},"及时发出故障声、光信号",{"key":24,"text":134,"correct":31},"及时发出故障声、光及报警信号",{"key":26,"text":136,"correct":22},"显示并记录故障时间",{"key":29,"text":138,"correct":22},"显示并记录故障的部位、类型",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":29,"analysis":32},964775,"下面哪项不是消防设备电源状态监控器的组成部分（ ）。",[143,145,147,149],{"key":20,"text":144,"correct":22},"工作状态指示灯",{"key":24,"text":146,"correct":22},"液晶显示屏",{"key":26,"text":148,"correct":22},"操作键盘",{"key":29,"text":150,"correct":31},"稳压装置",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":26,"analysis":32},964776,"不符合消防设备电源状态监控器的主电源和备用电源转换功能要求的是：（ ）。",[155,157,159,161],{"key":20,"text":156,"correct":22},"主电源应釆用220V、50Hz电源并设置过流保护措施",{"key":24,"text":158,"correct":22},"电源输入端应设接线端子",{"key":26,"text":160,"correct":31},"当交流电网供电电压变动幅度在额定电压220V的80%-10%范围内，频率偏差不超过标准颗率50Hz的±1%时，监控器应能正常工作",{"key":29,"text":162,"correct":22},"监控器的电源部分应具有主电源和备用电源转换功能，并应有主、备电源工作状态指示",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":29,"analysis":32},964777,"消防设备电源状态监控器的主电源和备用电源转换功能不正确的有：（ ）。",[167,168,170,172],{"key":20,"text":162,"correct":22},{"key":24,"text":169,"correct":22},"当主电源断电时，能自动转换到备用电源；当主电源恢复时，能自动转换到主电源；",{"key":26,"text":171,"correct":22},"主、备电源的转换不应影响监控器的正常工作",{"key":29,"text":173,"correct":31},"监控器的备用电源在放电至终止电压条件下充电12h所获得的容量应能提供监控器在正常监视状态下至少工作8h",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":29,"analysis":32},964778,"给监控器自身备用电源充电的充电器与备用电源间连接线的断路、短路时，监控器应能在（ ）s内发出故障声、光信号。",[178,180,182,184],{"key":20,"text":179,"correct":22},"10",{"key":24,"text":181,"correct":22},"30",{"key":26,"text":183,"correct":22},"50",{"key":29,"text":185,"correct":31},"100",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":26,"analysis":32},964779,"被监控电源电压值大于额定电压的（ ）%或小于额定电压的85%时，监控器应能在100s内发出故障声、光信号。",[190,192,194,196],{"key":20,"text":191,"correct":22},"80",{"key":24,"text":193,"correct":22},"85",{"key":26,"text":195,"correct":31},"110",{"key":29,"text":197,"correct":22},"115",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":24,"analysis":32},964780,"被监控电源发生缺相、错相、过载等供电异常现象时，监控器应能在100s内发出故障声、光信号。请问这是消防设备电源状态监控器的哪项功能？（ ）",[202,204,206,208],{"key":20,"text":203,"correct":22},"自检",{"key":24,"text":205,"correct":31},"故障报警",{"key":26,"text":207,"correct":22},"信息显示",{"key":29,"text":209,"correct":22},"历史事件记录",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":32},964781,"交流单相电压传感器和交流单相电压\u002F电流传感器可用于监测供电电源为（ ）的消防设备。如各种报警设备、电源配电箱、应急照明回路等。",[214,216,218,220],{"key":20,"text":215,"correct":22},"AC200V",{"key":24,"text":217,"correct":31},"AC220V",{"key":26,"text":219,"correct":22},"AC380V",{"key":29,"text":221,"correct":22},"AC400V",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":26,"analysis":32},964782,"交流三相电压\u002F电流传感器可用于监测供电电源为（ ）的消防设备，如风机、泵类设备、交流三相电源配电箱等。",[226,227,228,229],{"key":20,"text":215,"correct":22},{"key":24,"text":217,"correct":22},{"key":26,"text":219,"correct":31},{"key":29,"text":221,"correct":22},{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":26,"analysis":32},964783,"电流通过导体产生的热量，与电流强度的（ ）、导体的电阻及通电时间成正比。",[234,236,238,240],{"key":20,"text":235,"correct":22},"三次方",{"key":24,"text":237,"correct":22},"—次方",{"key":26,"text":239,"correct":31},"平方",{"key":29,"text":241,"correct":22},"四次方",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":20,"analysis":32},964784,"把几个电子元件的一端连在一起，另一端也连在一起，然后把两端接入电路的方式称为（ ）。",[246,248,250,252],{"key":20,"text":247,"correct":31},"并联",{"key":24,"text":249,"correct":22},"串郑",{"key":26,"text":251,"correct":22},"串并联",{"key":29,"text":253,"correct":22},"混联",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":24,"analysis":32},964785,"建筑高度88m的宾馆，其消防控制室、消防水泵房、消防电梯间、防排烟风机房等的供电，应在最末一级配电箱处设置（ ）装置。",[258,260,262,264],{"key":20,"text":259,"correct":22},"手动切换",{"key":24,"text":261,"correct":31},"自动切换",{"key":26,"text":263,"correct":22},"自动或手动切换",{"key":29,"text":265,"correct":22},"自动和手动切换",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":26,"analysis":32},964786,"一类高层建筑应釆用自动启动的应急发电机组，启动时间不应大于（ ）s。",[270,271,273,274],{"key":20,"text":179,"correct":22},{"key":24,"text":272,"correct":22},"15",{"key":26,"text":181,"correct":31},{"key":29,"text":275,"correct":22},"60",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":24,"analysis":32},964787,"下列有关安全使用家用电器的说法中，错误的是（ ）。",[280,282,284,286],{"key":20,"text":281,"correct":22},"电冰箱及电视机等电器不要短时间内连续切断、接通电源",{"key":24,"text":283,"correct":31},"为节约空间，可以在电冰箱后面塞放可燃物",{"key":26,"text":285,"correct":22},"室外天线或共用天线的避雷器要有良好的接地，雷雨天气时尽量不要使用室外天线",{"key":29,"text":287,"correct":22},"电热毯第一次使用或长期搁置后再使用，应在有人监视的情况下先通电一段时",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":29,"analysis":32},964788,"下列关于空调器具电气防火要求及技术措施，错误的是（ ）。",[292,294,296,298],{"key":20,"text":293,"correct":22},"空调器具应单独供电，电源线应设置短路、过载保护",{"key":24,"text":295,"correct":22},"空调不要靠近窗帘、门帘等悬挂物，以免卷入电机而使电机发热起火",{"key":26,"text":297,"correct":22},"由于空调不具备防雷功能，雷雨天气时，最好不要使用空调",{"key":29,"text":299,"correct":31},"空调电源插头的容量应大于插座的容量且匹配",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":32},964789,"电气防火要求及技术措施中规定节日彩灯连接线路应釆用绝缘铜导线，导线截面和应满足载流量要求，且不应小于（ ），灯头线不应小于1.0mm。",[304,306,308,310],{"key":20,"text":305,"correct":31},"2.5",{"key":24,"text":307,"correct":22},"2.0",{"key":26,"text":309,"correct":22},"1.5",{"key":29,"text":311,"correct":22},"1.0",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":20,"analysis":32},964790,"在潮湿场所中，插座应釆用密封型并带保护地线触头的保护型插座，安装高度不低于（ ）m。",[316,317,319,321],{"key":20,"text":309,"correct":31},{"key":24,"text":318,"correct":22},"1.8",{"key":26,"text":320,"correct":22},"2.1",{"key":29,"text":322,"correct":22},"2.4",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":26,"analysis":32},964791,"消防用电设备供电线路当线路暗敷设时，要对所穿金属导管或难燃性刚性塑料导管进行保护，并要敷设在不燃烧结构内，保护层厚度不要小于（ ）mm。",[327,328,330,331],{"key":20,"text":179,"correct":22},{"key":24,"text":329,"correct":22},"20",{"key":26,"text":181,"correct":31},{"key":29,"text":332,"correct":22},"40",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":26,"analysis":32},964792,"消防用电设备供配电系统启动装置要求，当消防用电负荷为一级时，应设置自功启动装置，并在主电源断电后（ ）s内供电；当消防负荷为二级且釆用自动启动方式有困难时，可釆用手动启动装置。",[337,338,339,340],{"key":20,"text":179,"correct":22},{"key":24,"text":329,"correct":22},{"key":26,"text":181,"correct":31},{"key":29,"text":332,"correct":22},{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":26,"analysis":32},964793,"以低频交流电源逐台驱动消防水泵的自动巡检，每台消防水泵低速转动的时间不应少于（ ）min。",[345,347,349,351],{"key":20,"text":346,"correct":22},"0.5",{"key":24,"text":348,"correct":22},"l",{"key":26,"text":350,"correct":31},"2",{"key":29,"text":352,"correct":22},"3",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":26,"analysis":32},964794,"一级负荷供电的建筑，当釆用自备发电设备作备用电源时，自备发电设备应设置自动和手动启动装置，且自动启动方式应能在（ ）s内供电。",[357,358,359,360],{"key":20,"text":179,"correct":22},{"key":24,"text":329,"correct":22},{"key":26,"text":181,"correct":31},{"key":29,"text":275,"correct":22},{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":26,"analysis":32},964795,"消防用电设备的配电线路暗敷时，应穿管并应敷设在不燃烧体结构内且保护层厚度不应小于（ ）mm。",[365,366,367,368],{"key":20,"text":179,"correct":22},{"key":24,"text":329,"correct":22},{"key":26,"text":181,"correct":31},{"key":29,"text":332,"correct":22},{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":29,"analysis":32},964796,"消防水泵出水管上应设置压力表，压力表的最大量程不应低于水泵额定工作压力的2倍，且不应低于（ ）MPA。",[373,374,376,378],{"key":20,"text":346,"correct":22},{"key":24,"text":375,"correct":22},"0.8",{"key":26,"text":377,"correct":22},"1",{"key":29,"text":379,"correct":31},"1.6",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":26,"analysis":32},964797,"以自动或手动方式启动消防水泵时，消防水泵应在（ ）s内投入正常运行。",[384,385,386,387],{"key":20,"text":272,"correct":22},{"key":24,"text":329,"correct":22},{"key":26,"text":181,"correct":31},{"key":29,"text":388,"correct":22},"45",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":29,"analysis":32},964798,"柴油机消防水泵的供油箱应根据火灾延续时间确定，且油箱最小有效容积应按1.5L\u002FkW配置，油箱内储存的燃料不应小于（ ）%的储量。",[393,395,396,398],{"key":20,"text":394,"correct":22},"90",{"key":24,"text":191,"correct":22},{"key":26,"text":397,"correct":22},"70",{"key":29,"text":183,"correct":31},{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":20,"analysis":32},964799,"根据《建筑设计防火规范》（GB50016）规定：一类高层民用建筑应按（ ）负荷要求供电。",[403,405,407,409],{"key":20,"text":404,"correct":31},"一级",{"key":24,"text":406,"correct":22},"二级",{"key":26,"text":408,"correct":22},"三级",{"key":29,"text":410,"correct":22},"四级",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":24,"analysis":32},964800,"消防用电设备应釆用（ ）的供电回路，其配电设备应设有明显标志。",[415,417,419,421],{"key":20,"text":416,"correct":22},"共用",{"key":24,"text":418,"correct":31},"专用",{"key":26,"text":420,"correct":22},"自用",{"key":29,"text":422,"correct":22},"混用",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":29,"analysis":32},964801,"自动喷水灭火系统中利用有压气体作为严密性检测的是（ ）。",[427,429,431,433],{"key":20,"text":428,"correct":22},"干式系统",{"key":24,"text":430,"correct":22},"湿式系统",{"key":26,"text":432,"correct":22},"预作用系统",{"key":29,"text":434,"correct":31},"干式系统和预作用系统",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":24,"analysis":32},964802,"排烟口的设置宜使烟流方向与人员疏散方向相反，排烟口与附近安全出口相邻边缘之间的水平距离不应小于（ ）m。",[439,440,441,442],{"key":20,"text":311,"correct":22},{"key":24,"text":309,"correct":31},{"key":26,"text":318,"correct":22},{"key":29,"text":307,"correct":22},{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":24,"analysis":32},964803,"机械排烟系统使用金属管道时，管道设计风速不应大于（ ）m\u002Fs。",[447,448,449,451],{"key":20,"text":272,"correct":22},{"key":24,"text":329,"correct":31},{"key":26,"text":450,"correct":22},"25",{"key":29,"text":181,"correct":22},{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":26,"analysis":32},964804,"排烟风机应满足280℃时连续工作（ ）min的要求，排烟风机应与风机入口处的排烟防火阀连锁，当该阀关闭时，排烟风机应能停止运转。",[456,457,458,459],{"key":20,"text":179,"correct":22},{"key":24,"text":329,"correct":22},{"key":26,"text":181,"correct":31},{"key":29,"text":275,"correct":22},{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":29,"analysis":32},964805,"建筑高度超过100m的住宅，其排烟系统应竖向分段独立设置，且每段高度不应超过（ ）m。",[464,465,466,467],{"key":20,"text":183,"correct":22},{"key":24,"text":191,"correct":22},{"key":26,"text":394,"correct":22},{"key":29,"text":185,"correct":31},{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":29,"analysis":32},964806,"不能够抑制火灾蔓延的消防设施是（ ）。",[472,474,476,478],{"key":20,"text":473,"correct":22},"防火门",{"key":24,"text":475,"correct":22},"防火卷帘",{"key":26,"text":477,"correct":22},"防排烟控制装置",{"key":29,"text":479,"correct":31},"声光警报装置",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":24,"analysis":32},964807,"下列情况通风、空气调节系统的风管道不需要设70℃防火阀的是（ ）。",[484,486,488,490],{"key":20,"text":485,"correct":22},"穿越通风、空气调节机房及重要的或火灾危险性大的房间隔墙和楼板处。",{"key":24,"text":487,"correct":31},"管道穿越防烟分区处。",{"key":26,"text":489,"correct":22},"穿越变形缝处的两侧。",{"key":29,"text":491,"correct":22},"管道穿越防火分区处。",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":20,"analysis":32},964808,"建筑加压送风口的设置要求是（ ）。",[496,498,500,502],{"key":20,"text":497,"correct":31},"楼梯间宜每隔2至3层设一个送风口；前室的送风口应每层设1个",{"key":24,"text":499,"correct":22},"楼梯间宜每层设一个送风口；前室的送风口应每层设1个",{"key":26,"text":501,"correct":22},"楼梯间宜每隔2至3层设一个送风口；前室的送风口应每隔2至3层设1",{"key":29,"text":503,"correct":22},"楼梯间宜每隔1至2层设一个送风口；前室的送风口应每隔1层设1个",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":29,"analysis":32},964809,"在防火阀两侧各（ ）mm范围内的风管及其绝热材料应釆用不燃材料。",[508,509,510,512],{"key":20,"text":191,"correct":22},{"key":24,"text":185,"correct":22},{"key":26,"text":511,"correct":22},"150",{"key":29,"text":513,"correct":31},"200",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":20,"analysis":32},964810,"设在项棚上的机械排烟口，距附近安全出口沿走道方向相邻边缘之间的最小水平距离不应小于（ ）m。",[518,519,520,521],{"key":20,"text":309,"correct":31},{"key":24,"text":350,"correct":22},{"key":26,"text":352,"correct":22},{"key":29,"text":522,"correct":22},"4",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":20,"analysis":32},964811,"板式排烟口打开后无法联动启动排烟风机的原因不可能是（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":31},"排烟风机控制柜处在“自动”状态",{"key":24,"text":530,"correct":22},"执行机构及风机控制箱内的联动线存在松动、脱落现象",{"key":26,"text":532,"correct":22},"执行机构上常开触点在排烟口打开时不能转换为常闭",{"key":29,"text":534,"correct":22},"消防联动线路断路",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":29,"analysis":32},964812,"正压送风机在运行中，各个正压送风口没有风出来的原因不可能是（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"风机出风口是否有阀门关闭",{"key":24,"text":542,"correct":22},"风机是否反转",{"key":26,"text":544,"correct":22},"风井是否被异物封堵",{"key":29,"text":546,"correct":31},"风道内壁不光滑",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":20,"analysis":32},964813,"防烟分区的挡烟垂壁，应釆用（ ）装修材料。",[551,553,555,557],{"key":20,"text":552,"correct":31},"A级",{"key":24,"text":554,"correct":22},"B1级",{"key":26,"text":556,"correct":22},"B2级",{"key":29,"text":558,"correct":22},"B3级",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":20,"analysis":32},964814,"设在项棚上的排烟口，距可燃构件或可燃物的距离不应小于（ ）。",[563,565,567,569],{"key":20,"text":564,"correct":31},"l.00m",{"key":24,"text":566,"correct":22},"1.50m",{"key":26,"text":568,"correct":22},"2.00m",{"key":29,"text":570,"correct":22},"2.50m",[572,575,578,581,584,587],{"id":15,"name":573,"category":7,"favorite":574},"领导干部任职前廉政法规知识测试题",92,{"id":576,"name":577,"category":7,"favorite":15},595,"建筑结构与设备",{"id":579,"name":580,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":582,"name":583,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":585,"name":586,"category":7,"favorite":8},534,"BIM工程师",{"id":588,"name":586,"category":7,"favorite":8},535]