[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":601},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,11,50,2716,[13,34,46,58,70,82,94,106,118,129,141,153,165,177,189,201,213,225,234,243,254,266,278,290,298,310,319,331,342,354,366,378,386,398,410,422,433,445,457,469,481,493,505,517,529,541,553,565,577,589],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},964714,1,"单选题","公称直径小于200mm的雨淋阀调试时，自动和手动方式启动的雨淋阀应在（ ）s内启动。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","90",false,{"key":24,"text":25,"correct":22},"B","60",{"key":27,"text":28,"correct":29},"C","15",true,{"key":31,"text":32,"correct":22},"D","5","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},964715,"闭式系统的喷头，其公称动作温度宜高于环境最高温度（ ）摄氏度。",[38,40,42,44],{"key":20,"text":39,"correct":22},"10",{"key":24,"text":41,"correct":22},"20",{"key":27,"text":43,"correct":29},"30",{"key":31,"text":45,"correct":22},"40",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},964716,"开式洒水喷头或水幕喷头、雨淋报警阀组以及水流报警装置（水流指示器或压力开关）等组成，用于挡烟阻火和冷却分隔物的喷水系统是（ ）系统。",[50,52,54,56],{"key":20,"text":51,"correct":22},"雨淋",{"key":24,"text":53,"correct":22},"闭式",{"key":27,"text":55,"correct":29},"水幕",{"key":31,"text":57,"correct":22},"泡沫",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},964717,"自动喷水灭火系统最不利点喷头最低工作压力不应小于（ ）MPa。配水管道的工作压力不应大于（ ）MPa。",[62,64,66,68],{"key":20,"text":63,"correct":29},"O.l，1.2",{"key":24,"text":65,"correct":22},"0.5，1.0",{"key":27,"text":67,"correct":22},"0.05，1.2",{"key":31,"text":69,"correct":22},"0.05，1.0",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},964718,"水力警铃的工作压力不应小于（ ）MPa。",[74,76,78,80],{"key":20,"text":75,"correct":22},"0.03",{"key":24,"text":77,"correct":29},"0.05",{"key":27,"text":79,"correct":22},"0.08",{"key":31,"text":81,"correct":22},"0.1",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},964719,"下列不属于洒水喷头按安装方式分类的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":29},"闭式喷头",{"key":24,"text":89,"correct":22},"下垂型喷头",{"key":27,"text":91,"correct":22},"直立型喷头",{"key":31,"text":93,"correct":22},"吊项隐藏型喷头",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},964720,"湿式系统适合在环境温度不低于（ ）并不高于（ ）的环境中使用。",[98,100,102,104],{"key":20,"text":99,"correct":22},"5℃，60℃",{"key":24,"text":101,"correct":22},"5℃，70℃",{"key":27,"text":103,"correct":22},"4℃，60℃",{"key":31,"text":105,"correct":29},"4℃，70℃",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},964721,"下列属于自动喷水灭火开式系统的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"湿式系统",{"key":24,"text":113,"correct":29},"雨淋系统",{"key":27,"text":115,"correct":22},"干式系统",{"key":31,"text":117,"correct":22},"预作用系统",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},964722,"自动喷水灭火系统等自动水灭火系统应根据喷头灭火需求压力确定；如湿式系统应保证最不利点喷头静压不小于（ ）Mpa。",[122,123,125,127],{"key":20,"text":81,"correct":29},{"key":24,"text":124,"correct":22},"0.15O",{"key":27,"text":126,"correct":22},"0.3",{"key":31,"text":128,"correct":22},"0.5",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":31,"analysis":33},964723,"自动喷水灭火系统施工，安装前检查喷头的型号、规格、使用场所应符合设计要求。应检查全数的（ ）。",[133,135,137,139],{"key":20,"text":134,"correct":22},"10%",{"key":24,"text":136,"correct":22},"20%",{"key":27,"text":138,"correct":22},"50%",{"key":31,"text":140,"correct":29},"100%",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":27,"analysis":33},964724,"对预作用自动喷水灭火系统应用范围描述错误的是（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"用于严禁管道漏水",{"key":24,"text":148,"correct":22},"用于严禁系统误喷",{"key":27,"text":150,"correct":29},"替代湿式系统",{"key":31,"text":152,"correct":22},"替代干式系统",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":31,"analysis":33},964725,"干式报警阀维护保养程序（ ）应对水压表进行检査，确保系统维持正常的水压。",[157,159,161,163],{"key":20,"text":158,"correct":22},"一季",{"key":24,"text":160,"correct":22},"一月",{"key":27,"text":162,"correct":22},"半月",{"key":31,"text":164,"correct":29},"一周",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":27,"analysis":33},964726,"湿式报警阀的水力警铃，（ ）应检查一次警铃转动是否正常。",[169,171,173,175],{"key":20,"text":170,"correct":22},"每日",{"key":24,"text":172,"correct":22},"每周",{"key":27,"text":174,"correct":29},"每半月",{"key":31,"text":176,"correct":22},"每月",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":24,"analysis":33},964727,"自动喷水灭火系统的湿式报警阀调试时，在试水装置处放水，带延迟器的水力警铃应在（ ）内发出报警铃声。",[181,183,185,187],{"key":20,"text":182,"correct":22},"5-60s",{"key":24,"text":184,"correct":29},"5-90s",{"key":27,"text":186,"correct":22},"10-30s",{"key":31,"text":188,"correct":22},"20-60s",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":24,"analysis":33},964728,"自动喷水灭火系统由洒水喷头、（ ）、水流报警装置等组件以及管道、供水设施组成。",[193,195,197,199],{"key":20,"text":194,"correct":22},"自救卷盘",{"key":24,"text":196,"correct":29},"报警阀组",{"key":27,"text":198,"correct":22},"手动触发按钮",{"key":31,"text":200,"correct":22},"启泵按钮",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":27,"analysis":33},964729,"关于水锤消除器的使用注意点，正确的有（ ）。",[205,207,209,211],{"key":20,"text":206,"correct":22},"阀体上的压力表，安装前显示管道压力，安装后显示阀体气室压力",{"key":24,"text":208,"correct":22},"安装前请确认，水锤消除器气室压力不得低于管道压力",{"key":27,"text":210,"correct":29},"若管道内水压力较低，或水锤消除器气室压力较低，皆可打开水锤消除器上方注气栓加入气压或释放气压",{"key":31,"text":212,"correct":22},"水锤消除器气室压力，维持于管道压力50%、60%时水锤消除器效果较佳。",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":24,"analysis":33},964730,"预作用喷水灭火系统自动联动触发信号是预设逻辑的（ ），由消防联动控制器按照预设逻辑完成自动灭火的控制。",[217,219,221,223],{"key":20,"text":218,"correct":22},"压力开关信号",{"key":24,"text":220,"correct":29},"火灾触发信号",{"key":27,"text":222,"correct":22},"水流指示器信号",{"key":31,"text":224,"correct":22},"信号阀动作信号",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":24,"analysis":33},964731,"泡沫泵站与保护对象的距离不宜小于30m，且应满足在泡沫消防泵启动后，将泡沫混合液或泡沫输送到最远保护对象的时间不宜大于（ ）min。",[229,230,232,233],{"key":20,"text":43,"correct":22},{"key":24,"text":231,"correct":29},"50",{"key":27,"text":39,"correct":22},{"key":31,"text":28,"correct":22},{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":27,"analysis":33},964732,"泡沫喷淋系统与泡沫-水喷淋系统控制应具备自动、手动和应急机械启动功能，在自动控制状态下，系统的响应时间不应大于（ ）s。",[238,239,241,242],{"key":20,"text":43,"correct":22},{"key":24,"text":240,"correct":22},"45",{"key":27,"text":25,"correct":29},{"key":31,"text":21,"correct":22},{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":24,"analysis":33},964733,"局部应用式中倍数泡沫灭火系统适用于（ ）m2以内的液体流淌火灾。",[247,248,250,252],{"key":20,"text":231,"correct":22},{"key":24,"text":249,"correct":29},"100",{"key":27,"text":251,"correct":22},"150",{"key":31,"text":253,"correct":22},"200",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":24,"analysis":33},964734,"（ ）分为局部应用式、移动式两种类型。",[258,260,262,264],{"key":20,"text":259,"correct":22},"低倍数泡沫灭火系统",{"key":24,"text":261,"correct":29},"中倍数泡沫灭火系统",{"key":27,"text":263,"correct":22},"高倍数泡沫灭火系统",{"key":31,"text":265,"correct":22},"泡沫泡灭火系统",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":31,"analysis":33},964735,"固定消防泡灭火系统按喷射介质分类不包括（ ）。",[270,272,274,276],{"key":20,"text":271,"correct":22},"消防水泡灭火系统",{"key":24,"text":273,"correct":22},"消防泡沫泡灭火系统",{"key":27,"text":275,"correct":22},"消防干粉泡灭火系统",{"key":31,"text":277,"correct":29},"消防气体泡灭火系统",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":20,"analysis":33},964736,"消防水泡灭火系统适用于（ ）火灾的扑救。",[282,284,286,288],{"key":20,"text":283,"correct":29},"一般固体可燃物",{"key":24,"text":285,"correct":22},"甲、乙，丙类液体",{"key":27,"text":287,"correct":22},"固体可燃物",{"key":31,"text":289,"correct":22},"可燃气体",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":31,"analysis":33},964737,"消防干粉泡灭火系统适用于（ ）火灾的扑敉。",[294,295,296,297],{"key":20,"text":283,"correct":22},{"key":24,"text":285,"correct":22},{"key":27,"text":287,"correct":22},{"key":31,"text":289,"correct":29},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":31,"analysis":33},964738,"消防水泡灭火系统不能用于哪些场所？（ ）",[302,304,306,308],{"key":20,"text":303,"correct":22},"石化企业",{"key":24,"text":305,"correct":22},"飞机维修库",{"key":27,"text":307,"correct":22},"输油码头",{"key":31,"text":309,"correct":29},"飞机库",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":33},964739,"消防泡沫泡灭火系统不适用于哪些场所？（ ）",[314,315,316,317],{"key":20,"text":303,"correct":22},{"key":24,"text":305,"correct":29},{"key":27,"text":309,"correct":22},{"key":31,"text":318,"correct":22},"仓库",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":31,"analysis":33},964740,"对于充液传动管启动水喷雾灭火系统的说法不正确的是（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"充液传动管内的介质一般为压力水",{"key":24,"text":326,"correct":22},"这种方式适用于不结冰的场所",{"key":27,"text":328,"correct":22},"充液传动管的末端或最高点应安装自动排气阀",{"key":31,"text":330,"correct":29},"适用于北方寒冷地区",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":31,"analysis":33},964741,"对于充气传动管启动水喷雾灭火系统的说法不正确的是（ ）。",[335,337,339,341],{"key":20,"text":336,"correct":22},"充气传动管内的介质一般是压缩空气，由空压机或其他气源保持充气传动管内平时的气压",{"key":24,"text":338,"correct":22},"这种方式适用于所有场所",{"key":27,"text":340,"correct":22},"但在北方寒冷地区，应在充气传动管的最低点设置冷凝器和气水分离器，保证充气传动管不会被冷凝水结冰堵寒",{"key":31,"text":328,"correct":29},{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":24,"analysis":33},964742,"固定式水喷雾灭火系统组成部分不包括（ ）。",[346,348,350,352],{"key":20,"text":347,"correct":22},"火灾自动报警系统",{"key":24,"text":349,"correct":29},"雨淋阀组",{"key":27,"text":351,"correct":22},"固定管道",{"key":31,"text":353,"correct":22},"水雾喷头",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":31,"analysis":33},964743,"关于泡沫-水喷雾联用系统的说法不正确的是（ ）。",[358,360,362,364],{"key":20,"text":359,"correct":22},"在水喷雾系统的雨淋报警阀前连接泡沫储罐和泡沫比例混合器",{"key":24,"text":361,"correct":22},"再与火灾报警控制系统、雨淋报警阀、水雾喷头组成的一个完整的系统",{"key":27,"text":363,"correct":22},"在火灾发生时，先喷泡沫灭火，再喷水雾冷却或灭火",{"key":31,"text":365,"correct":29},"在火灾发生时，先喷水雾灭火，再喷泡沫冷却或灭火",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":27,"analysis":33},964744,"电动启动水喷雾灭火系统不是通过（ ）火灾探测器探测火灾的。",[370,372,374,376],{"key":20,"text":371,"correct":22},"感温",{"key":24,"text":373,"correct":22},"感烟",{"key":27,"text":375,"correct":29},"传动管",{"key":31,"text":377,"correct":22},"缆式",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":27,"analysis":33},964745,"水（气）传动管启动水喷雾灭火系统以（ ）作为火灾探测系统。",[382,383,384,385],{"key":20,"text":371,"correct":22},{"key":24,"text":373,"correct":22},{"key":27,"text":375,"correct":29},{"key":31,"text":377,"correct":22},{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":27,"analysis":33},964746,"关于水（气）传动管启动水喷雾灭火系统工作原理说法不正确的是（ ）。",[390,392,394,396],{"key":20,"text":391,"correct":22},"传动管内充满压缩空气或压力水",{"key":24,"text":393,"correct":22},"当传动管上的闭式洒水喷头受火灾高温影响动作后，传动管内的压力迅速下降，打开封闭的雨淋报警阀",{"key":27,"text":395,"correct":29},"传动管的火灾报警信号通过报警阀传到火灾报警控制器和水泵控制柜，直接启动水泵或同时由报警控制器启动水泵",{"key":31,"text":397,"correct":22},"通过雨淋报警阀、管网将水送到水雾喷头，水雾喷头开始喷水灭火",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":27,"analysis":33},964747,"电动启动情况下，当只有一种探测器发出火警信号时，下面哪一项描述不正确？（ ）",[402,404,406,408],{"key":20,"text":403,"correct":22},"水喷雾灭火控制盘即发出火灾声、光警报信号，通知有异常情况发生",{"key":24,"text":405,"correct":22},"不启动灭火装置释放灭火剂",{"key":27,"text":407,"correct":29},"发出联动指令，关闭风机、防火阀等联动设备",{"key":31,"text":409,"correct":22},"如确需启动水喷雾灭火系统灭火时，在水喷雾灭火控制盘面板按下“紧急启动”按钮，即可启动灭火装置",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":24,"analysis":33},964748,"预作用式细水雾灭火系统准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持（ ）充水的压力，预作用报警阀后的管道内平时无水或充以有压气体。",[414,416,418,420],{"key":20,"text":415,"correct":22},"管道内",{"key":24,"text":417,"correct":29},"预作用阀组入口前管道内",{"key":27,"text":419,"correct":22},"预作用阀组出口前管道内",{"key":31,"text":421,"correct":22},"预作用报警阀后的管道内",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":20,"analysis":33},964749,"湿式细水雾灭火系统在准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持（ ）充水的压力。",[426,427,429,431],{"key":20,"text":415,"correct":29},{"key":24,"text":428,"correct":22},"细水雾控制阀组入口前管道内",{"key":27,"text":430,"correct":22},"细水雾控制阀组出口前管道内",{"key":31,"text":432,"correct":22},"细水雾控制报警阀后的管道内",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":24,"analysis":33},964750,"对湿式细水雾灭火系统的工作原理的说法不正确的是（ ）。",[437,439,441,443],{"key":20,"text":438,"correct":22},"发生火灾时，在火灾温度的作用下，闭式喷头的热敏元件动作，喷头开启并开始喷水",{"key":24,"text":440,"correct":29},"此时，管网中的水由静止变为流动，流量开关动作送出电信号，在报警控制器上显示所有区域喷水的信息",{"key":27,"text":442,"correct":22},"由于持续喷水泄压造成管网水压下降，压力开关动作并输出启动供水泵的信号",{"key":31,"text":444,"correct":22},"供水泵投入运行后，完成系统的启动过程，实施灭火",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":31,"analysis":33},964751,"自动控制方式下，当只有一种探测器发出火警信号时，下面哪项不正确？（ ）",[449,451,453,455],{"key":20,"text":450,"correct":22},"细水雾灭火控制装置即发出声、光火警信号通知有异常情况发生",{"key":24,"text":452,"correct":22},"而不启动灭火装置释放细水雾",{"key":27,"text":454,"correct":22},"如确需启动细水雾灭火系统灭火时，在细水雾灭火控制盘面板操作按下“启动”按钮即可启动灭火装置释放细水雾，实施灭火",{"key":31,"text":456,"correct":29},"启动灭火装置后，有一段时间延时",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":27,"analysis":33},964752,"自动控制方式下，当两个或两类探测器同时发出火警信号时，下面哪项说法不正确？（ ）",[461,463,465,467],{"key":20,"text":462,"correct":22},"细水雾灭火控制盘发出火灾声、光警报信号，通知有火灾发",{"key":24,"text":464,"correct":22},"有关人员应撤离现场，并发出联动指令，关闭风机、防火阀等联动设备",{"key":27,"text":466,"correct":29},"同时发出灭火指令，启动细水雾水泵",{"key":31,"text":468,"correct":22},"火灾报警控制器联动控制细水雾灭火控制盘打开区域控制电磁阀，释放灭火剂（水），实施灭火",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":27,"analysis":33},964753,"无论灭火控制盘是处于“自动”还是“手动”状态，按下任何（ ）按钮，都可启动细水雾灭火系统，释放灭火剂，实施灭火。",[473,475,477,479],{"key":20,"text":474,"correct":22},"按下启动",{"key":24,"text":476,"correct":22},"启动按下",{"key":27,"text":478,"correct":29},"紧急启动",{"key":31,"text":480,"correct":22},"立即启动",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":31,"analysis":33},964754,"对于细水雾开式或预作用式灭火系统的应急机械启动工作方式描述不正确的是（ ）。",[485,487,489,491],{"key":20,"text":486,"correct":22},"手动关闭联动设备并切断电源",{"key":24,"text":488,"correct":22},"启动细水雾消防水泵，手动打开对应区域分区控制阀",{"key":27,"text":490,"correct":22},"细水雾控制阀开启后，若为开式灭火系统，细水雾灭火系统管网开始充水，实施灭火",{"key":31,"text":492,"correct":29},"若为湿式灭火系统，细水雾灭火系统管网开始充水，待闭式细水雾洒水喷头玻璃球爆破后即可实施灭火",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":24,"analysis":33},964755,"下面哪一项不是储气瓶型干粉灭火系统的干粉灭火设备部分的构成部分（ ）。",[497,499,501,503],{"key":20,"text":498,"correct":22},"干粉储罐及其配件",{"key":24,"text":500,"correct":29},"输水管道",{"key":27,"text":502,"correct":22},"安全泄放装置",{"key":31,"text":504,"correct":22},"干粉喷放器",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":24,"analysis":33},964757,"关于储气瓶型干粉灭火系统的动作顺序不正确的是（ ）。",[509,511,513,515],{"key":20,"text":510,"correct":22},"启动机构储气瓶-减压器子粉储罐",{"key":24,"text":512,"correct":29},"干粉储罐-选择阀-出口总阀门-输粉管",{"key":27,"text":514,"correct":22},"出口总阀门-选择阀-输粉管-子粉枪或干粉泡",{"key":31,"text":516,"correct":22},"出口总阀门-选择阀-输粉管-固定喷嘴",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":31,"analysis":33},964758,"柜式灭火装置的组成部分不包括（ ）。",[521,523,525,527],{"key":20,"text":522,"correct":22},"柜体",{"key":24,"text":524,"correct":22},"干粉储罐",{"key":27,"text":526,"correct":22},"输粉管道",{"key":31,"text":528,"correct":29},"干粉报警控制器",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":27,"analysis":33},964759,"当要求双电源或为了进一步提高可靠性时，消防给水设备经常釆用由（ ）驱动的消防泵组。",[533,535,537,539],{"key":20,"text":534,"correct":22},"燃油机",{"key":24,"text":536,"correct":22},"电动机",{"key":27,"text":538,"correct":29},"柴油机",{"key":31,"text":540,"correct":22},"汽油机",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":27,"analysis":33},964760,"柴油机消防泵组不是由（ ）组成。",[545,547,549,551],{"key":20,"text":546,"correct":22},"柴油机消防泵控制柜",{"key":24,"text":548,"correct":22},"消防泵",{"key":27,"text":550,"correct":29},"消防专用电动机",{"key":31,"text":552,"correct":22},"燃油箱",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":20,"analysis":33},964761,"下面哪个部件不是柴油机消防泵组的组成部分（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":29},"传送装置",{"key":24,"text":560,"correct":22},"仪器仪表",{"key":27,"text":562,"correct":22},"热交换冷却系统",{"key":31,"text":564,"correct":22},"蓄电池",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":20,"analysis":33},964762,"下面哪一项不是水幕系统的组成部分？（ ）",[569,571,573,575],{"key":20,"text":570,"correct":29},"闭式洒水喷头",{"key":24,"text":572,"correct":22},"雨淋报警阀组",{"key":27,"text":574,"correct":22},"水流报警装置",{"key":31,"text":576,"correct":22},"供水设施",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":27,"analysis":33},964763,"关于水幕系统的手动控制方式说法错误的是（ ）。",[581,583,585,587],{"key":20,"text":582,"correct":22},"水幕系统相关控制阀组和消防泵控制箱（柜）的启动、停止按钮是用专用线路直接连接至设置在消防控制室内的消防联动控制器的手动控制盘",{"key":24,"text":584,"correct":22},"消防控制盘能够直接手动控制消防泵的启动、停止及水幕系统相关控制阀组的开启",{"key":27,"text":586,"correct":29},"水幕系统开启后，需有权限的管理人员确认才能停止",{"key":31,"text":588,"correct":22},"当已确认有水幕系统需要启动时，可通过在设备间操作对应水幕系统雨淋报警阀组的应急启动阀门使水幕系统启动、停止",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":24,"analysis":33},964764,"当自动控制的水幕系统用于防火卷帘的保护时（防护冷却水幕系统），以下说法错误的是（ ）。",[593,595,597,599],{"key":20,"text":594,"correct":22},"应由防火卷帘下落到楼板面的动作信号与本报警区域内任一火灾探测器或手动火灾报警按钮的报警信号组成“与”逻辑作为水幕阀组启动的联动触发信号",{"key":24,"text":596,"correct":29},"应由防火卷帘下落到楼板面的动作信号与同一防火分区两个不同的火灾探测器或手动火灾报警按钮的报警信号组成“与”逻辑作为水幕阀组启动的联动触发信号",{"key":27,"text":598,"correct":22},"应由消防联动控制器联动控制水幕系统相关控制阀组的启动",{"key":31,"text":600,"correct":22},"雨淋报警阀开启，压力开关动作，连锁启动水幕消防泵",[602,605,608,611,614,617],{"id":15,"name":603,"category":7,"favorite":604},"领导干部任职前廉政法规知识测试题",92,{"id":606,"name":607,"category":7,"favorite":15},595,"建筑结构与设备",{"id":609,"name":610,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":612,"name":613,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":615,"name":616,"category":7,"favorite":8},534,"BIM工程师",{"id":618,"name":616,"category":7,"favorite":8},535]