[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-701-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":565},{"id":5,"name":6,"category":7,"favorite":8},701,"高级技能","建筑工程",0,1,50,2716,[13,33,45,57,69,81,93,105,117,129,139,151,159,169,180,191,203,211,223,232,244,255,267,278,287,295,307,315,326,334,342,352,361,373,383,395,407,419,431,443,454,466,478,490,502,510,522,533,541,553],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":23,"analysis":32},964211,"单选题","主消防控制室的集中火灾报警控制器通过直接手动控制单元连接到共用消防设备，这种方式可通过集中火灾报警控制器的（ ）按键实现手动控制。",[18,22,26,29],{"key":19,"text":20,"correct":21},"A","手动控制",false,{"key":23,"text":24,"correct":25},"B","直接手动控制单元",true,{"key":27,"text":28,"correct":21},"C","自动控制",{"key":30,"text":31,"correct":21},"D","应急控制","",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":27,"analysis":32},964212,"集中火灾报警控制器不能查询区域火灾报警控制器或分消防控制室内控制器上传的（ ）等实时信息。",[37,39,41,43],{"key":19,"text":38,"correct":21},"火警",{"key":23,"text":40,"correct":21},"联动",{"key":27,"text":42,"correct":25},"监视",{"key":30,"text":44,"correct":21},"故障",{"id":46,"libraryId":5,"type":9,"typeLabel":15,"stem":47,"options":48,"answer":19,"analysis":32},964213,"集中火灾报警控制器可查询区域火灾报警控制器或分消防控制室内控制器上传的火警、联动、监管、故障、屏蔽等（ ）信息。",[49,51,53,55],{"key":19,"text":50,"correct":25},"实时",{"key":23,"text":52,"correct":21},"定时",{"key":27,"text":54,"correct":21},"循环",{"key":30,"text":56,"correct":21},"状态",{"id":58,"libraryId":5,"type":9,"typeLabel":15,"stem":59,"options":60,"answer":23,"analysis":32},964214,"集中火灾报警控制器当前报警信息显示的说法不正确的是（ ）。",[61,63,65,67],{"key":19,"text":62,"correct":21},"高等级的状态信息优先显示",{"key":23,"text":64,"correct":25},"低等级状态信息和高等级状态信息循环显示",{"key":27,"text":66,"correct":21},"当集中火灾报警控制器处于某一高等级状态显示时，应能通过手动操作查询其他低等级状态信息",{"key":30,"text":68,"correct":21},"各状态信息不应交替显示",{"id":70,"libraryId":5,"type":9,"typeLabel":15,"stem":71,"options":72,"answer":30,"analysis":32},964215,"集中火灾报警控制器上每条报警信息的显示内容说法不正确的是（ ）。",[73,75,77,79],{"key":19,"text":74,"correct":21},"在集中火灾报警控制器上通过查看每条报警信息的“控制器号”“回路号”和“设备编码”内容，可以确定具体的报警点位",{"key":23,"text":76,"correct":21},"如果“控制器号”部分带有“网络”字样则是区域火灾报警控制器上传的信息",{"key":27,"text":78,"correct":21},"如果“控制器号”部分带有“本机”字样则是集中火灾报警控制器配接部件的报警信息。",{"key":30,"text":80,"correct":25},"如果“控制器号”部分带有“网络”字样则是集中火灾报警控制器配接部件的报警信息。",{"id":82,"libraryId":5,"type":9,"typeLabel":15,"stem":83,"options":84,"answer":27,"analysis":32},964216,"对于水泵等（ ）的重要消防设备，可釆用对共用消防设备直接手动控制和对共用消防设备跨区控制的方式实现。",[85,87,89,91],{"key":19,"text":86,"correct":21},"主消防控制室",{"key":23,"text":88,"correct":21},"分消防控制室",{"key":27,"text":90,"correct":25},"主消防控制室和分消防控制室共用",{"key":30,"text":92,"correct":21},"主消防控制室和分消防控制室各自",{"id":94,"libraryId":5,"type":9,"typeLabel":15,"stem":95,"options":96,"answer":23,"analysis":32},964217,"当发生故障时，传输设备应在（ ）内发出与火灾报警和手动报警有明显区别的本机故障声、光信号，并指示出类型，本机故障声信号应能手动消除，再有故障发生时，应能再启动；本机故障光信号应保持至故障排除。",[97,99,101,103],{"key":19,"text":98,"correct":21},"60",{"key":23,"text":100,"correct":25},"100",{"key":27,"text":102,"correct":21},"20",{"key":30,"text":104,"correct":21},"30",{"id":106,"libraryId":5,"type":9,"typeLabel":15,"stem":107,"options":108,"answer":27,"analysis":32},964218,"火灾报警传输设备也称用户信息传输装置（简称传输设备或传输装置），设置在联网用户端，通过公用通信网或专用通信网等报警传输网络，与（ ）进行信息传输。",[109,111,113,115],{"key":19,"text":110,"correct":21},"火灾报警控制器（联动型）",{"key":23,"text":112,"correct":21},"火灾报警传输设备",{"key":27,"text":114,"correct":25},"城市消防远程监控中心",{"key":30,"text":116,"correct":21},"消防控制室图形显示装置",{"id":118,"libraryId":5,"type":9,"typeLabel":15,"stem":119,"options":120,"answer":19,"analysis":32},964219,"关于火灾报警传输设备的信息的接收与传输功能描述正确的有（ ）。",[121,123,125,127],{"key":19,"text":122,"correct":25},"火灾报警传输设备应能接收来自火灾报警控制器的火灾报警、监管报警、故障报警和屏蔽信息，并发出指示相应状态的光信号。",{"key":23,"text":124,"correct":21},"传输设备应在30s内将来自火灾报警控制器的信息传送给消防远程监控中心。",{"key":27,"text":126,"correct":21},"在处理和传输各类报警信息或屏蔽信息时，传输设备对应状态指示灯应常亮",{"key":30,"text":128,"correct":21},"在得到监控中心的正确接收确认后，传输设备对应状态指示灯应闪亮并在确认后或火灾探测报警系统复位后保持5min",{"id":130,"libraryId":5,"type":9,"typeLabel":15,"stem":131,"options":132,"answer":23,"analysis":32},964220,"传输设备应在（ ）s内将来自火灾报警控制器的信息传送给消防远程监控中心。",[133,135,137,138],{"key":19,"text":134,"correct":21},"5",{"key":23,"text":136,"correct":25},"10",{"key":27,"text":102,"correct":21},{"key":30,"text":104,"correct":21},{"id":140,"libraryId":5,"type":9,"typeLabel":15,"stem":141,"options":142,"answer":27,"analysis":32},964221,"关于火灾报警传输设备的信息的接收与传输功能说法不正确的是（ ）。",[143,145,147,149],{"key":19,"text":144,"correct":21},"传输设备在传输监管、故障、屏蔽或自检信息期间，如火灾报警控制器发出火灾报警信息，传输设备应能优先接收并传输火灾报警信息。",{"key":23,"text":146,"correct":21},"传输设备应在10s内将来自火灾报警控制器的信息传送给消防远程监控中心",{"key":27,"text":148,"correct":25},"在得到监控中心的正确接收确认后，传输设备对应状态指示灯应常亮并在确认后或火灾探测报警系统复位后保持3min",{"key":30,"text":150,"correct":21},"当信息传送失败时应发出声、光信号",{"id":152,"libraryId":5,"type":9,"typeLabel":15,"stem":153,"options":154,"answer":23,"analysis":32},964222,"传输设备应设手动报警按键（钮），当手动报警按键（钮）动作时，应发出指示手动报警状态的光信号，并在（ ）s内将手动报警信息传送给监控中心。",[155,156,157,158],{"key":19,"text":134,"correct":21},{"key":23,"text":136,"correct":25},{"key":27,"text":102,"correct":21},{"key":30,"text":104,"correct":21},{"id":160,"libraryId":5,"type":9,"typeLabel":15,"stem":161,"options":162,"answer":23,"analysis":32},964223,"消防联动控制器接收到火灾报警信号后，应在（ ）s内发出启动信号。",[163,165,167,168],{"key":19,"text":164,"correct":21},"1",{"key":23,"text":166,"correct":25},"3",{"key":27,"text":134,"correct":21},{"key":30,"text":136,"correct":21},{"id":170,"libraryId":5,"type":9,"typeLabel":15,"stem":171,"options":172,"answer":27,"analysis":32},964224,"消防控制室应能集中控制、显示和管理建筑内所有消防设施包括火灾报警与消防联动控制设施设备的状态信息，并能将状态信息通过网络传输到（ ）。",[173,175,177,178],{"key":19,"text":174,"correct":21},"状态监视中心",{"key":23,"text":176,"correct":21},"应急指挥中心",{"key":27,"text":114,"correct":25},{"key":30,"text":179,"correct":21},"信息中心",{"id":181,"libraryId":5,"type":9,"typeLabel":15,"stem":182,"options":183,"answer":30,"analysis":32},964225,"消防控制室是建筑消防系统的信息中心、控制中心、日常运行管理中心和各自动消防系统运行状态监视中心，也是建筑发生火和日常火灾演练时的（ ）。",[184,186,188,190],{"key":19,"text":185,"correct":21},"信息交互中心",{"key":23,"text":187,"correct":21},"控制中心",{"key":27,"text":189,"correct":21},"数据中心",{"key":30,"text":176,"correct":25},{"id":192,"libraryId":5,"type":9,"typeLabel":15,"stem":193,"options":194,"answer":23,"analysis":32},964226,"消防控制室图形显示装置与火灾报警控制器、消防联动控制器、电气火灾监控器、可燃气体报警控制器等消防设备之间，应釆用（ ）连接。",[195,197,199,201],{"key":19,"text":196,"correct":21},"专门线路",{"key":23,"text":198,"correct":25},"专用线路",{"key":27,"text":200,"correct":21},"指定线路",{"key":30,"text":202,"correct":21},"通用线路",{"id":204,"libraryId":5,"type":9,"typeLabel":15,"stem":205,"options":206,"answer":30,"analysis":32},964227,"消防控制室图形显示装置在与控制器及其他消防设备（设施）之间不能正常通信时，应在（ ）s内发出与火灾报警信号有明显区别的故障声、光信号，故障声信号应能手动消除，故障光信号应保持至故障排除。",[207,208,209,210],{"key":19,"text":136,"correct":21},{"key":23,"text":104,"correct":21},{"key":27,"text":98,"correct":21},{"key":30,"text":100,"correct":25},{"id":212,"libraryId":5,"type":9,"typeLabel":15,"stem":213,"options":214,"answer":27,"analysis":32},964228,"消防控制室图形显示装置与火灾报警控制器的通信故障报警功能说法不正确的有（ ）。",[215,217,219,221],{"key":19,"text":216,"correct":21},"消防控制室图形显示装置应能监视并显示与各类控制器通信的工作状态",{"key":23,"text":218,"correct":21},"消防控制室图形显示装置在与控制器及其他消防设备（设施）之间不能正常通信时，应在100s内发出与火灾报警信号有明显区别的故障声、光信号",{"key":27,"text":220,"correct":25},"故障光信号应能手动消除，故障声信号应保持至故障排除",{"key":30,"text":222,"correct":21},"消防控制室图形显示装置与控制器的信息应同步，且在通信中断又恢复后，应能重新接收并正确显示",{"id":224,"libraryId":5,"type":9,"typeLabel":15,"stem":225,"options":226,"answer":23,"analysis":32},964229,"火灾报警控制器通过串口RS232、RS485、RS422以及并口等数据传输接口向（ ）传输相关报警信息。",[227,228,229,230],{"key":19,"text":110,"correct":21},{"key":23,"text":112,"correct":25},{"key":27,"text":116,"correct":21},{"key":30,"text":231,"correct":21},"消防联动控制器",{"id":233,"libraryId":5,"type":9,"typeLabel":15,"stem":234,"options":235,"answer":30,"analysis":32},964230,"消防控制室图形显示装置与火灾报警控制器的信息接收与状态显示功能说法不正确的是（ ）。",[236,238,240,242],{"key":19,"text":237,"correct":21},"当有火灾报警信号、监管报警信号、屏蔽信号、故障信号输入时，火灾报警控制器应向消防控制室图形显示装置发送输入信号的类别、名称、部位、位置、时间、工作状态等信息",{"key":23,"text":239,"correct":21},"消防控制室图形显示装置在火灾报警信号、反馈信号输入10s内显示相应状态信息",{"key":27,"text":241,"correct":21},"在其他信号输入100s内显示相应状态信息。",{"key":30,"text":243,"correct":25},"在信息传输过程中，火灾报警信息应和其他信息轮流传输",{"id":245,"libraryId":5,"type":9,"typeLabel":15,"stem":246,"options":247,"answer":23,"analysis":32},964231,"传输设备在传输监管、故障、屏蔽或自检信息期间，如火灾报警控制器发出火灾报警信息，传输设备应能（ ）接收并传输火灾报警信息。",[248,250,252,253],{"key":19,"text":249,"correct":21},"依次",{"key":23,"text":251,"correct":25},"优先",{"key":27,"text":54,"correct":21},{"key":30,"text":254,"correct":21},"同时",{"id":256,"libraryId":5,"type":9,"typeLabel":15,"stem":257,"options":258,"answer":30,"analysis":32},964232,"关于火灾报警传输设备的手动报警功能说法不正确的是（ ）。",[259,261,263,265],{"key":19,"text":260,"correct":21},"传输设备在传输火灾报警、监管、故障、屏蔽或自检信息期间，应能优先进行手动报警操作和手动报警信息传输。",{"key":23,"text":262,"correct":21},"传输设备在手动报警操作并传输信息时，手动报警指示灯应闪亮",{"key":27,"text":264,"correct":21},"在得到监控中心的正确接收确认后，手动报警指示灯应常亮并保持60s。当信息传送失败时应发出声、光信号。",{"key":30,"text":266,"correct":25},"传输设备应设手动报警按键（钮），当手动报警按键（钮）动作时，应发出指示手动报警状态的光信号，并在305内将手动报警信息传送给监控中心。",{"id":268,"libraryId":5,"type":9,"typeLabel":15,"stem":269,"options":270,"answer":19,"analysis":32},964233,"关于火灾报警传输设备的手动报警功能描述不正确的是（ ）。",[271,273,275,277],{"key":19,"text":272,"correct":25},"传输设备应设手动报警按键（钮），当手动报警按键（钮）动作时，应发出指示手动报警状态的声、光信号，并在10s内将手动报警信息传送给监控中心。",{"key":23,"text":274,"correct":21},"传输设备在手动报警操作并传输信息时，手动报警指示灯应闪亮，在得到监控中心的正确接收确认后，该指示灯应常亮并保持60s。",{"key":27,"text":276,"correct":21},"当信息传送失败时传输设备应发出声、光信号。",{"key":30,"text":260,"correct":21},{"id":279,"libraryId":5,"type":9,"typeLabel":15,"stem":280,"options":281,"answer":19,"analysis":32},964234,"消防控制室图形显示装置在可燃气体报警信号输入（ ）s内显示相应状态信息，在其他信号输入100s内显示相应状态信息。",[282,283,284,286],{"key":19,"text":136,"correct":25},{"key":23,"text":104,"correct":21},{"key":27,"text":285,"correct":21},"50",{"key":30,"text":100,"correct":21},{"id":288,"libraryId":5,"type":9,"typeLabel":15,"stem":289,"options":290,"answer":30,"analysis":32},964235,"消防控制室图形显示装置在可燃气体报警信号输入10s内显示相应状态信息，在其他信号输入（ ）s内显示相应状态信息。",[291,292,293,294],{"key":19,"text":136,"correct":21},{"key":23,"text":104,"correct":21},{"key":27,"text":285,"correct":21},{"key":30,"text":100,"correct":25},{"id":296,"libraryId":5,"type":9,"typeLabel":15,"stem":297,"options":298,"answer":30,"analysis":32},964236,"可燃气体报警控制器与消防控制室图形显示装置的信息传输功能说法不正确的是（ ）。",[299,301,303,305],{"key":19,"text":300,"correct":21},"消防控制室图形显示装置在接收到可燃气体探测报警系统的可燃气体报警信号后，10s内将报警信息按规定的通信协议格式传送给监控中。",{"key":23,"text":302,"correct":21},"消防控制室图形显示装置应能接收监控中心的查询指令并能按规定的通信协议格式和规定的内容将相应信息传送到监控中心。",{"key":27,"text":304,"correct":21},"在信息传输过程中，可燃气体报警信息应主动传输，且优先于其他信息。",{"key":30,"text":306,"correct":25},"消防控制室图形显示装置通过公用网络将规定的内容将相应信息传送到监控中心。",{"id":308,"libraryId":5,"type":9,"typeLabel":15,"stem":309,"options":310,"answer":19,"analysis":32},964237,"消防控制室图形显示装置在接收到可燃气体探测报警系统的可燃气体报警信号后，（ ）s内将报警信息按规定的通信协议格式传送给监控中心。",[311,312,313,314],{"key":19,"text":136,"correct":25},{"key":23,"text":104,"correct":21},{"key":27,"text":285,"correct":21},{"key":30,"text":100,"correct":21},{"id":316,"libraryId":5,"type":9,"typeLabel":15,"stem":317,"options":318,"answer":27,"analysis":32},964238,"电气火灾监控设备与消防控制室图形显示装置的通信故障报警功能说法不正确的有（ ）。",[319,321,323,324],{"key":19,"text":320,"correct":21},"消防控制室图形显示装置应能监视并显示与电气火灾监控设备通信的工作状态",{"key":23,"text":322,"correct":21},"消防控制室图形显示装置在与电气火灾监控设备之间不能正常通信时，应在100s内发出与火灾报警信号有明显区别的故障声、光信号",{"key":27,"text":220,"correct":25},{"key":30,"text":325,"correct":21},"消防控制室图形显示装置与电气火灾监控设备之间的信息应同步，且在通信中断又恢复后，应能重新接收并正确显示",{"id":327,"libraryId":5,"type":9,"typeLabel":15,"stem":328,"options":329,"answer":30,"analysis":32},964239,"消防控制室图形显示装置在与电气火灾监控设备之间不能正常通信时，应在（ ）s内发出与火灾报警信号有明显区别的故障声、光信号，故障声信号应能手动消除，故障光信号应保持至故障排除。",[330,331,332,333],{"key":19,"text":136,"correct":21},{"key":23,"text":104,"correct":21},{"key":27,"text":98,"correct":21},{"key":30,"text":100,"correct":25},{"id":335,"libraryId":5,"type":9,"typeLabel":15,"stem":336,"options":337,"answer":19,"analysis":32},964240,"消防控制室图形显示装置在接收到系统的监控报警信号后，（ ）s内将报警信息按规定的通信协议格式传送给监控中心。",[338,339,340,341],{"key":19,"text":136,"correct":25},{"key":23,"text":104,"correct":21},{"key":27,"text":285,"correct":21},{"key":30,"text":100,"correct":21},{"id":343,"libraryId":5,"type":9,"typeLabel":15,"stem":344,"options":345,"answer":27,"analysis":32},964241,"可燃气体探测报警系统能够在保护区域内泄漏可燃气体的浓度低于（ ）%爆炸下限（LEL）的条件下报警，从而预防由于可燃气体泄漏引发的火灾和爆炸事故的发生。",[346,348,349,351],{"key":19,"text":347,"correct":21},"15",{"key":23,"text":102,"correct":21},{"key":27,"text":350,"correct":25},"25",{"key":30,"text":104,"correct":21},{"id":353,"libraryId":5,"type":9,"typeLabel":15,"stem":354,"options":355,"answer":23,"analysis":32},964242,"可燃气体报警控制器与消防控制室图形显示装置应釆用（ ）连接，一般釆用RS232、RS485、CAN、以太网、US B、LAN\u002FWAN等通信接口。",[356,358,359,360],{"key":19,"text":357,"correct":21},"公用线路",{"key":23,"text":198,"correct":25},{"key":27,"text":196,"correct":21},{"key":30,"text":200,"correct":21},{"id":362,"libraryId":5,"type":9,"typeLabel":15,"stem":363,"options":364,"answer":30,"analysis":32},964243,"以下不属于区域报警系统必须设置的组件是（ ）。",[365,367,369,371],{"key":19,"text":366,"correct":21},"火灾探测器",{"key":23,"text":368,"correct":21},"手动报警按钮",{"key":27,"text":370,"correct":21},"火灾声光警报器",{"key":30,"text":372,"correct":25},"消防图形显示装置",{"id":374,"libraryId":5,"type":9,"typeLabel":15,"stem":375,"options":376,"answer":27,"analysis":32},964244,"以下属于集中报警系统但不属于区域报警系统特有的组件的是（ ）。",[377,378,379,381],{"key":19,"text":366,"correct":21},{"key":23,"text":368,"correct":21},{"key":27,"text":380,"correct":25},"消防应急广播",{"key":30,"text":382,"correct":21},"火灾报警控制器",{"id":384,"libraryId":5,"type":9,"typeLabel":15,"stem":385,"options":386,"answer":30,"analysis":32},964245,"某商业综合体建筑，其办公区、酒店区、商业区分别设置消防控制室，并将办公区的消防控制室作为主消防控制室其他两个作为分消防控制室。下列关于各分消防控制室内的消防设施之间的关系的说法，正确的是（ ）。",[387,389,391,393],{"key":19,"text":388,"correct":21},"不可以互相传输、显示状态消息，不应互相控制",{"key":23,"text":390,"correct":21},"不可以互相传输、显示状态信息，但应互相控制",{"key":27,"text":392,"correct":21},"可以互相传输、显示状态信息，也应互相控制",{"key":30,"text":394,"correct":25},"可以互相传输、显示状态信息，但不应互相控制",{"id":396,"libraryId":5,"type":9,"typeLabel":15,"stem":397,"options":398,"answer":30,"analysis":32},964246,"关于控制中心报警系统的说法，不符合规范要求的是（ ）。",[399,401,403,405],{"key":19,"text":400,"correct":21},"控制中心报警系统至少包含两个集中报警系统",{"key":23,"text":402,"correct":21},"控制中心报警系统具备消防联动控制功能",{"key":27,"text":404,"correct":21},"控制中心报警系统至少设置一个消防主控制室",{"key":30,"text":406,"correct":25},"控制中心报警系统各分消防控制室之间可以相互传输信息并控制重要设备。",{"id":408,"libraryId":5,"type":9,"typeLabel":15,"stem":409,"options":410,"answer":19,"analysis":32},964247,"火灾报警控制器之间通常釆用RS485、CAN等通信方式进行联网，联网方式不包括：（ ）。",[411,413,415,417],{"key":19,"text":412,"correct":25},"方型联网拓扑",{"key":23,"text":414,"correct":21},"总线型联网拓扑",{"key":27,"text":416,"correct":21},"环型联网拓扑",{"key":30,"text":418,"correct":21},"星型联网拓扑",{"id":420,"libraryId":5,"type":9,"typeLabel":15,"stem":421,"options":422,"answer":19,"analysis":32},964248,"关于火灾报警控制器之间总线型联网拓扑方式的优点是（ ）。",[423,425,427,429],{"key":19,"text":424,"correct":25},"布线要求简单、扩充容易、增删不影响其他工作",{"key":23,"text":426,"correct":21},"简化了路径选择的控制、控制软件简单",{"key":27,"text":428,"correct":21},"易于维护、安全性高、系统可靠性高",{"key":30,"text":430,"correct":21},"维护难、分支节点故障查找难",{"id":432,"libraryId":5,"type":9,"typeLabel":15,"stem":433,"options":434,"answer":30,"analysis":32},964249,"关于火灾报警控制器之间几种联网方式的说法不正确的是（ ）。",[435,437,439,441],{"key":19,"text":436,"correct":21},"总线型联网拓扑布线要求简单、扩充容易、增删不影响其他工作",{"key":23,"text":438,"correct":21},"环型联网拓扑简化了路径选择的控制、控制软件简单",{"key":27,"text":440,"correct":21},"星型联网拓扑易于维护、安全性高、系统可靠性高",{"key":30,"text":442,"correct":25},"星型联网拓扑维护难、分支节点故障查找难",{"id":444,"libraryId":5,"type":9,"typeLabel":15,"stem":445,"options":446,"answer":23,"analysis":32},964250,"关于火灾报警控制器之间几种联网方式的优缺点说法不正确的是（ ）。",[447,449,451,452],{"key":19,"text":448,"correct":21},"星型联网拓扑安装维护工作量大、中央节点负担重、分布处理能力低",{"key":23,"text":450,"correct":25},"总线型联网拓扑不便扩充、维护难",{"key":27,"text":440,"correct":21},{"key":30,"text":453,"correct":21},"总线型联网拓扑维护难、分支节点故障查找难",{"id":455,"libraryId":5,"type":9,"typeLabel":15,"stem":456,"options":457,"answer":19,"analysis":32},964251,"消防设备电源监控系统是用于监控消防设备（ ）工作状态，在电源发生断电、过压、欠压、过流、缺相等故障时能发出报警信号的监控系统。",[458,460,462,464],{"key":19,"text":459,"correct":25},"电源",{"key":23,"text":461,"correct":21},"电流",{"key":27,"text":463,"correct":21},"电压",{"key":30,"text":465,"correct":21},"火灾",{"id":467,"libraryId":5,"type":9,"typeLabel":15,"stem":468,"options":469,"answer":30,"analysis":32},964252,"下列不符合消防设备电源监控系统的工作原理的是（ ）。",[470,472,474,476],{"key":19,"text":471,"correct":21},"系统通过电压传感器、电流传感器、电压\u002F电流传感器实时监视消防设备的电源状态",{"key":23,"text":473,"correct":21},"当监视到消防设备电源发生断电、过压、欠压、过流、缺相、错相等故障时，实时将故障信息上传至消防设备电源状态监控器",{"key":27,"text":475,"correct":21},"由监控器发出故障警报，显示故障类型和位置",{"key":30,"text":477,"correct":25},"同时将故障报警信息上传给消防控制室图形显示装置，提示消防控制室对故障进行及时处理",{"id":479,"libraryId":5,"type":9,"typeLabel":15,"stem":480,"options":481,"answer":30,"analysis":32},964253,"关于消防设备电源状态监控器工作状态指示灯的说法不正确的是（ ）。",[482,484,486,488],{"key":19,"text":483,"correct":21},"系统交流电源故障时，黄色主电故障指示灯点亮",{"key":23,"text":485,"correct":21},"系统备用电源故障时，黄色备电故障指示灯点亮",{"key":27,"text":487,"correct":21},"监控器由交流电源供电时，绿色主电工作指示灯点亮",{"key":30,"text":489,"correct":25},"监控器由备用电源供电时，黄色主电故障指示灯点亮",{"id":491,"libraryId":5,"type":9,"typeLabel":15,"stem":492,"options":493,"answer":30,"analysis":32},964254,"当黄色故障指示灯点亮时，不可能是什么故障？（ ）。",[494,496,498,500],{"key":19,"text":495,"correct":21},"总线设备离线",{"key":23,"text":497,"correct":21},"通讯故障",{"key":27,"text":499,"correct":21},"本身故障",{"key":30,"text":501,"correct":25},"互感器故障",{"id":503,"libraryId":5,"type":9,"typeLabel":15,"stem":504,"options":505,"answer":19,"analysis":32},964255,"在处理和传输各类报警信息或屏蔽信息时，传输设备对应状态指示灯应闪亮，在得到监控中心的正确接收确认后，该指示灯应常亮并在确认后或火灾探测报警系统复位后保持（ ）min。",[506,507,508,509],{"key":19,"text":134,"correct":25},{"key":23,"text":136,"correct":21},{"key":27,"text":102,"correct":21},{"key":30,"text":104,"correct":21},{"id":511,"libraryId":5,"type":9,"typeLabel":15,"stem":512,"options":513,"answer":27,"analysis":32},964256,"火灾报警控制器与消防联动控制器的通信功能说法不正确的是（ ）。",[514,516,518,520],{"key":19,"text":515,"correct":21},"消防联动控制器应能接收来自相关火灾报警控制器的火灾报警信号，显示报警区域，发出火灾报警声、光信号",{"key":23,"text":517,"correct":21},"报警声信号应能手动消除",{"key":27,"text":519,"correct":25},"报警声信号应保持至消防联动控制器复位",{"key":30,"text":521,"correct":21},"消防联动控制器接收到火灾报警信号后，应在35内发出启动信号",{"id":523,"libraryId":5,"type":9,"typeLabel":15,"stem":524,"options":525,"answer":30,"analysis":32},964257,"关于火灾报警控制器与消防联动控制器的通信功能的描述不正确的是（ ）。",[526,528,530,531],{"key":19,"text":527,"correct":21},"当消防联动控制器与火灾报警控制器之间的连接线发生断路、短路和影响功能的接地时，消防联动控制器应发出故障报警信号并指示出故障类型。",{"key":23,"text":529,"correct":21},"火灾报警控制器（联动型）应能接收来自火灾探测器及其他火灾报警触发器件的火灾报警信号，指示火灾发生部位和发生时间，并将火灾报警部位信息发送给消防联动控制设备",{"key":27,"text":515,"correct":21},{"key":30,"text":532,"correct":25},"消防联动控制器接收到火灾报警信号后，应在5s内发出启动信号",{"id":534,"libraryId":5,"type":9,"typeLabel":15,"stem":535,"options":536,"answer":19,"analysis":32},964258,"消防控制室图形显示装置在火灾报警信号、反馈信号输入（ ）s内显示相应状态信息，在其他信号输入100s内显示相应状态信息。",[537,538,539,540],{"key":19,"text":136,"correct":25},{"key":23,"text":104,"correct":21},{"key":27,"text":285,"correct":21},{"key":30,"text":100,"correct":21},{"id":542,"libraryId":5,"type":9,"typeLabel":15,"stem":543,"options":544,"answer":30,"analysis":32},964259,"火灾报警控制器同消防控制室图形显示装置的通信接口不包括（ ）。",[545,547,549,551],{"key":19,"text":546,"correct":21},"RS422总线接口",{"key":23,"text":548,"correct":21},"CAN总线接口",{"key":27,"text":550,"correct":21},"RJ45以太网接口",{"key":30,"text":552,"correct":25},"并口",{"id":554,"libraryId":5,"type":9,"typeLabel":15,"stem":555,"options":556,"answer":30,"analysis":32},964260,"使用传输设备的手动报警功能不适合哪种情况？（ ）。",[557,559,561,563],{"key":19,"text":558,"correct":21},"接收到人工报火警时（非手动报警按钮动作信号）",{"key":23,"text":560,"correct":21},"确认火灾后",{"key":27,"text":562,"correct":21},"传输设备自动传输釆集到的火灾报警控制器输出的火警信号失败后",{"key":30,"text":564,"correct":25},"传输设备与监控中心的通信线路（链路）不能保障信息传输时",[566,569,572,575,578,581],{"id":9,"name":567,"category":7,"favorite":568},"领导干部任职前廉政法规知识测试题",92,{"id":570,"name":571,"category":7,"favorite":9},595,"建筑结构与设备",{"id":573,"name":574,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":576,"name":577,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":579,"name":580,"category":7,"favorite":8},534,"BIM工程师",{"id":582,"name":580,"category":7,"favorite":8},535]