[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-965726":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},965726,701,2,"多选题","应急照明控制器不能自动控制系统设备应急启动、标志灯指示状态改变的原因是：（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","集中电源或应急照明配电箱输出端子接线不良",false,{"key":16,"text":17,"correct":14},"B","集中电源或应急照明配电箱输出回路总线短路、断路",{"key":19,"text":20,"correct":21},"C","应急照明控制器与火灾报警控制器、输出模块间线路接线不良",true,{"key":23,"text":24,"correct":21},"D","应急照明控制器与火灾报警控制器、输出模块间通信线路断路","CD","应急照明控制器不能自动控制系统设备应急启动、标志灯指示状态改变的原因：应急照明控制器与火灾报警控制器、输出模块间线路接线不良，应急照明控制器与火灾报警控制器、输出模块间通信线路断路。",{"id":6,"name":28,"category":29,"favorite":30},"高级技能","建筑工程",0]