[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-965616":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},965616,701,2,"多选题","泡沬喷雾灭火装置不能正常工作该如何解决（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","定期检査瓶组的压力，发现压力低于最低压力值时，应及时更换瓶组",false,{"key":16,"text":17,"correct":18},"B","拆下水雾喷头并清洗喷头内杂物",true,{"key":20,"text":21,"correct":18},"C","定期检査喷射口及清理杂物",{"key":23,"text":24,"correct":14},"D","更换密封玻璃，并重新进行密封性能试验，试验合格后方可安装","BC","设备名称：泡沬产生装置常见故障：低倍数泡沬产生器密封玻璃密封不严或损坏，导致储罐内可燃液体蒸气外泄，泡沬产生装置吸气口被杂物堵塞，导致发泡不正常，外浮顶储罐泡沬导流累喷射口被杂物堵塞，导致泡沬无法正常喷射。维修方法：更换密封玻璃，并重新进行密封性能试验，试验合格后方可安装，定期检査吸气口及清理杂物，定期检査喷射口及清理杂物。",{"id":6,"name":28,"category":29,"favorite":30},"高级技能","建筑工程",0]