[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-965394":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},965394,701,2,"多选题","下列关于雨淋阀组常见故障分析中正确的是（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","自动滴水阀漏水，产品存在质量问题",true,{"key":16,"text":17,"correct":14},"B","复位装置不能复位，水质过脏，有细小杂质进入复位装置密封面",{"key":19,"text":20,"correct":21},"C","长期无故报警，误将试验管路控制阀常闭",false,{"key":23,"text":24,"correct":14},"D","系统测试不报警，水力警铃进水口处喷嘴被堵塞、未配置铃锤或者铃锤卡死",{"key":26,"text":27,"correct":14},"E","雨淋报警阀不能进入伺应状态，复位装置存在问题","ABDE","关于雨淋阀组常见故障分析：自动滴水阀漏水，产品存在质量问题；复位装置不能复位，水质过脏，有细小杂质进入复位装置密封面；系统测试不报警，水力警铃进水口处喷嘴被堵塞、未配置铃锤或者铃锤卡死；雨淋报警阀不能进入伺应状态，复位装置存在问题。",{"id":6,"name":31,"category":32,"favorite":33},"高级技能","建筑工程",0]