[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-965377":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},965377,701,2,"多选题","气体灭火系统的月度检查内容主要包括（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","全部系统组件应无碰撞变形及其他机械性损伤，表面应无锈蚀，保护涂层应完好，铭牌和标志牌应清晰",true,{"key":16,"text":17,"correct":14},"B","手动操作装置的防护罩、铅封和安全标志应完整",{"key":19,"text":20,"correct":21},"C","灭火剂和驱动气体储存容器内的压力，不得小于设计储存压力的95%",false,{"key":23,"text":24,"correct":14},"D","预制灭火系统的设备状态和运行状况应正常",{"key":26,"text":27,"correct":14},"E","低压二氧化碳梅花系统存储装置的液位计检查，灭火剂损失10%时应及时补充","ABDE","气体灭火系统的月度检查内容主要包括全部系统组件应无碰擂变形及其他机械性损伤，表面应无锈蚀，保护涂层应完好，铭牌和标志牌应清晰；手动操作装置的防护罩、铅封和安全标志应完整；预制灭火系统的设备状态和运行状况应正常；低压二氧化碳梅花系统存储装置的液位计检查，灭火剂损失10%时应及时补充。",{"id":6,"name":31,"category":32,"favorite":33},"高级技能","建筑工程",0]